Glowworm Climapro 2 RF User manual

Climapro2RF
www.glow-worm.co.uk


- 1 -
1 Instructionsguidance.........................................................................................................................2
1.1 Productdocumentation...........................................................................................2
1.2 Explanationofsymbols...........................................................................................2
2 Climapro2RFdescription...................................................................................................................2
2.1 Regulationandstatutoryrequirements..................................................................2
2.2 OperationalDiagram..............................................................................................2
3 Safetyinstructionsandregulations....................................................................................................2
3.1 Safetyinstructions..................................................................................................2
3.2 Regulations.............................................................................................................2
4 Recycling...........................................................................................................................................3
4.1 Climapro2RF..........................................................................................................3
4.2 Packaging...............................................................................................................3
5 Installationlocation............................................................................................................................4
6 Climapro2RFInstallation...................................................................................................................4
6.1 Dimensions.............................................................................................................4
6.2 Listofcontents.......................................................................................................4
7 Fixing.................................................................................................................................................5
7.1 Fixingtheroomthermostat.....................................................................................5
8 Electricalconnections.......................................................................................................................5
8.1 Pairing(recognition)...............................................................................................5
9 Commissioning..................................................................................................................................5
9.1 Appliancesincludedintheinstallation....................................................................5
9.2 Roomthermostat...................................................................................................5
10 Specicsettings.................................................................................................................................6
10.1 Mainsettings..........................................................................................................6
10.2 Accesstotheinstallermenu...................................................................................6
10.3 Descriptionoftheinstallermenu............................................................................6
10.4 Heatingfunction......................................................................................................6
10.5 Domestichotwaterfunction...................................................................................7
10.6 Coolingfunction......................................................................................................7
10.7 Options...................................................................................................................8
10.8 Radio......................................................................................................................9
11 Control/Commissioning..................................................................................................................10
12 Userinformation...............................................................................................................................10
13 Faultdiagnosis................................................................................................................................. 11
14 Climapro2RF...................................................................................................................................12

0020094581_01-08/10-Glow-worm
- 2 -
INTRODUCTION
TheinstructionsareanintegralpartoftheClimapro2RFand
mustbehandedtotheuseroncompletionoftheinstallationin
ordertocomplywiththecurrentregulation.
• Carefullyreadthemanual,toenablesafeinstallation,use
andservicing.Noliabilitycanbeacceptedintheevent
ofdamagefornotcomplyingwiththeguidanceinthis
instructionmanual.
•
- Userinstructions
eDANGER: Risk of electric shock.
ATTENTION: Risk of damage to the Climapro2 RF
or to its vicinity.
IMPORTANT: Useful information.
CE Mark
heCEmarkindicatesthattheappliancesdescribedinthis
manualareincompliancewiththefollowingdirectives:
- EuropeanDirectiveNum.2004-108oftheEuropean
ParliamentandtheCouncilregardingelectromagnetic
compatibility
- EuropeanDirectiveNum.2006-95oftheEuropean
ParliamentandtheCouncilregardinglowvoltage
- Directiverelatingtotelecommunicationsequipment(Council
oftheEuropeanCommunitydirectiveR&TTE99/5/CEE).
Theroomthermostatcommunicateswithacontrolunitviaa
wirelessconnection.
1
2
3
4
AllworkinsideClimapro2RFmustbecarriedoutbyaqualied
professionalorGlow-worm’sAfter-SalesService.
Climapro2RFmustonlybeinstalledbyaqualiedand
responsibleprofessional.
Respectthebasicsafetyinstructions:
• Turnoffthecontrolunit’spowersupply.
• Whenworkontheapplianceiscompleted,performan
operationaltestandcheckforsafety.
Duringtheinstallationandactivationoftheappliance,the
decrees,directives,technicalregulations,standardsand
clauseshereaftermustbecompliedwithintheversionsthatare
currentlyinforce.

0020094581_01-08/10-Glow-worm
- 3 -
INTRODUCTION
The recycling of the packaging must be carried out
by the qualied professional who installed the room
thermostat.
Mostoftheapplianceismadeofrecyclablematerials.
Thissymbolindicatesthatthisunitmustnotbe
disposedofwithhouseholdwaste.Itshouldbe
selectivelycollectedforenergyrecovery,reuseor
recycling.
• Taketheunittoanappropriatecollectionpointfor
processing,energyrecoveryandrecyclingofwaste.
By complying with this directive, you will contribute
to the preservation of natural resources and the
protection of human health.
WerecommendthatyourecyclethepackagingofClimapro2RF
inaresponsiblefashion.
• Sortthewasteinordertoseparatethoseelementswhich
canberecycled(cardboard,plastics)andthosewhich
cannotberecycled.
• Disposeofthewasteinaccordancewithexistingregulations.

0020094581_01-08/10-Glow-worm
- 4 -
INSTALLATION
• Explainthefollowingrequirementstotheuser.
- inaroomprotectedfromfrost,
- onaninteriorwallofthemainroominthehome,
- atapproximately1.50metresfromtheoor(accordingtothe
regulationsinforce).
- nearsourcesofheat,suchasradiators,chimneywalls,
televisionsorsolarradiation,
- aboveacookerthatislikelytogiveoffsteamandgrease,
- oncoldwalls,
- betweenunitsorbehindcurtainsorotherobjectsthatmight
disturbtemperaturerecordingfortheambientairintheroom,
- inaroomthatisheavilyloadedwithdustorwherethe
atmosphereiscorrosive,
- nearaircurrentsthatmaycomefromdoorsorwindows.
1500
Allofthemeasurementsinthischapterareexpressedinmm.
62.5
34
6
173
66
27
58
6
- Thislistcontainsthefollowing:
- Climapro2RFprogrammableroomthermostat
- wallsupportforClimapro2RF
- packetcontaining2xingscrewswithrawlplugs
- 4“AALR6"alkalinebatteries.

0020094581_01-08/10-Glow-worm
- 5 -
INSTALLATION
• Determinetheinstallationlocation.Seethe"Installation
location"chapter.
A
B
1
2
4
3
5
6
• Positiontheroomthermostatsupport(4)onawall.
• Drill(A)thescrewholes(1)inaccordancewith2mounting
holes(3)inthewallsupport(4).
• Inserttherawlplugs(5)intheholes(1).
• Secure(B)theroomthermostatsupport(4)withscrews(2).
• Slidetheroomthermostat(6)intoitssupport(4).
Seetheinstallationmanualcontrolunit.
TheClimapro2RFandtheSystemprocontrolunitmustbe
paired.
• Turnontheappliancesthatmakeuptheinstallation(seethe
installationmanuals).
B
A
C
1
3
2
4
5
• Removetheinsulatingstrip(3)locatedinthebattery
compartment,respectingtheorderofoperations(A)to(C).
Theroomthermostatshowsitisnotconnected.

0020094581_01-08/10-Glow-worm
- 6 -
INSTALLATION
• Performthepairingoftheroomthermostatbasedonyour
installation(seepairingsection).
Accessingtheinstallermenuallowsforsomeadjustmentstobe
madetotheinstallation(roomthermostatandwirelessoutdoor
sensor)andtheroomthermostat’susermenu.
Heating Maximum
room
temperature
Chooseavaluebetween5°Cand
30°C.(factorysetting:30°C).
Room
temperature
correction
Chooseavaluebetween-5°Cand
5°Cwithastepof0.5°C.(factory
setting:0°C).
Hotwater On/Off Activate(ON)ordeactivate(OFF)
(defaultsetting:ON).
Program Enable(YES)ordisable(NO)
(defaultsetting:ON).
Coolingfunction On/Off Activate(ON)ordeactivate(OFF)
(defaultsetting:OFF).
Program Enable(YES)ordisable(NO)
(defaultsetting:OFF).
Efcientenergy
use
Energy
efciency
index
Enable(YES)ordisable(NO)
(defaultsetting:OFF).
• Pressbutton for7seconds.
• Entertheinstalleraccesscode96.
Usethebuttons:
Selectwiththebutton:
Pressthebutton:
- toreturntotheinstallermenu
screen,,
- for3secondstoreturntotheuser's
mainscreen.
Showing/enabling and disabling of functions is
reected in the user menu.
Denethemaximumadjustableroom
temperature.
Correctthemeasurementoftheroom
temperature.
Thisfunctionletsyouadjustthemaximumroomtemperature
thatcanbesetbytheuser(valueadjustablebetween5and
30°C-factorysetting:30°C).
• Fromtheinstallermenu(seeaccesstotheinstallermenu)
>selectonthescreen>heatingfunction>maximumroom
temp.
• Increaseordecreasewiththebuttons todisplaythe
initialcoolingtemperatureandpressthebutton .

0020094581_01-08/10-Glow-worm
- 7 -
INSTALLATION
Thisfunctionletsyourectifythetemperaturemeasuredbythe
roomtemperaturethermostat(by+/-5°Cwithastepof0.5°C-
(factorysetting:0).
• Fromtheinstallermenu(seeaccesstotheinstallermenu)
>selectonthescreen>>
• Increaseorreducewiththe buttonstodisplaythe
desiredcorrectionandvalidatewithbutton .
Showorhidethedomestichotwater
functionintheendusermenu.
Enableordisablethedomestichotwater
heatingprogramintheendusermenu.
Thisfunctionletsyouactivateordeactivatethehotwatermenu
fortheuser.Whenthefunctionisactivated,thefunctionwillbe
shownintheendusermenu.
If the function is deactivated, the domestic hot water
settings are adjusted via the appliance.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>
selectonthescreen>>
• Press tohighlightyourchoice(activateordeactivate)
andpressthebutton toconrm.
The hot water function must be activated before the
program can be set up. Depending on the appliance,
deactivation cuts off the hot water heating as well
as the production of hot water (see the appliances
installation manual).
Thisfunctionmakesitpossibletoallowtheusertoprogram
domestichotwaterheating.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>
selectonthescreen>>.
• Press tohighlightyourchoice(enableordisable)and
pressthebutton toconrm.
Showorhidethecoolingfunctioninthe
endusermenu.
Enableordisablethecoolingprogramin
theendusermenu.
Thisfunctionallowstheusertoactivateordeactivatethe
coolingmenu.Whenthefunctionisactivatedthefunctionwillbe
shownintheendusermenu.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>
selectonthescreen>>.

0020094581_01-08/10-Glow-worm
- 8 -
INSTALLATION
• Press tohighlightyourchoice(activateordeactivate)
andpressthebutton toconrm.
The cooling function must be activated before the
program can be set up.
Thisfunctionmakesitpossibletoallowtheusertoprogram
cooling.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>
selectonthescreen>>
• Press tohighlightyourchoice(activateordeactivate)
andpressthebutton toconrm.
Activateordeactivatethesystem
efciencyinfo.
Adjustthedateandtime
Choosethelanguage
Displayinformation:zone,typeand
softwareversionfortheroomthermostat
Thisfunctionallowstheusertoactivateordeactivatethe
systemefciencyinformation.
• Viatheinstallermenu(seeinstallermenu)>select>
>onthescreen.
• Press tohighlightyourchoice(activateordeactivate)
andpressthebutton toconrm.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>
selectonthescreen>>
•
• Setthedisplayformatofthecurrentdatebypressing
andpressing toconrm.Thereisachoicebetween
thefactorysettingday/month/yearandyear/month/day.
• Setthecurrentdatebypressing andpressingthe
button toconrm.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>
selectonthescreen>>
• Setthetimebypressing andpressingthebutton
toconrm.

0020094581_01-08/10-Glow-worm
- 9 -
INSTALLATION
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>
selectonthescreen>>
Todisplaytheadditionallanguages:
• Fromtheinstallationmenu(seeaccesstotheinstallermenu)
>selectonthescreen>
• Choosethelanguagewiththebutton andpressthe
button toconrm.
Thisfeatureallowsyoutodisplaythefollowinginformation:
area,softwaretypeandversion.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>
selectonthescreen>>
Establishtheconnectionbetweentheradio
receiverandtheClimapro2RF.
Testthequalityoftheradiosignal
(Climapro2RFandwirelessoutdoor
sensor).
Thisfunctionletsyouperformthepairingbetweenthe
Climapro2RFandtheradioreceiver.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>
selectonthescreen>>
• Consultthecontrolunitinstallationmanual.
Thisfunctionallowsyoutotestthesignalqualitybetweenthe
Climapro2RFandthecontrolunit.
Iftheheatingsystemincludesawirelessoutdoorsensor,the
Climapro2RFwillalsoindicatethequalityofthesignalbetween
thesensorandthecontrolunit.
Wait about fteen minutes after activating the
thermostat and remote sensor before testing.
Excellent Normalfunctioning
Average
Poor Operatinglimit*
Null Inoperative*
(*) Check the room thermostat’s batteries (see the
instructions). If the signal quality does not improve.
Change the location of the appliances, reducing
distances and removing obstacles.
• Fromtheprofessionalmenu(seeaccesstotheprofessional
menu)>selectonthescreen>>

0020094581_01-08/10-Glow-worm
- 10 -
INSTALLATION
AfterinstallingClimapro2RF:
• Starttheapplianceaccordingtotheoperatinginstructions
andcheckforcorrectoperation.
Attheendoftheinstallation:
- explaintheoperationoftheapplianceanditssafetydevices
totheuser,ifnecessaryprovideademonstrationandanswer
anyquestions;
- givetheuseralltherequireddocumentation,
- llinthedocumentswherenecessary;
- advisetheuseroftheprecautionsnecessarytoprevent
damagetothesystem,applianceandthebuilding;
- remindtheusertoservicetheapplianceannually.

0020094581_01-08/10-Glow-worm
- 11 -
MAINTENANCE
Faults described in this chapter should be carried
out by a qualied engineer and if needed by the
After Sales Service.
Youwillndalistofcertainerrorcodesintheusermanual.
Intheeventofaproblem:
• Checktheerrormessagesinthethermostat'sdisplayzone.

0020094581_01-08/10-Glow-worm
- 12 -
TECHNICALDATA
Transmission/reception
frequency
MHz 868
Transmission/reception
frequencybetweentheoutdoor
sensorandtheroomthermostat
(viathecontrolunit)
min 15
Transmission/reception
frequencybetweenthecontrol
unitandtheroomthermostat
min 10
Averageunobstructedworking
range(*)
m 100
Averagerangewithinthehome
(*)
m 25
{*)Canvaryaccordingtoinstallationconditionsandelectromagnetic
environment
Roomtemperatureauthorizedin
theroomwheretheapplianceis
installed
°C 50
Dimensions:
Height mm 173
Width mm 62,5
Depth mm 34
Supply:4“AALR6"alkaline
batteries
V 4x1.5
Batterylife(**) month 18
(**)Undernormalconditionsofuse
Dimensions:
Height mm 58
Width mm 66
Depth mm 27
Spacingbetweentheroom
thermostat(insupport)andthe
wall
mm 6


0020094581_01-08/10
Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions.
,NottinghamRoad,Belper,Derbyshire.DE561JT
Table of contents
Other Glowworm Thermostat manuals
Popular Thermostat manuals by other brands

Airxcel
Airxcel RVP 9430 339 Series Installation, operation & application guide

Dimplex
Dimplex TS521W manual

Salus
Salus RT520 quick start guide

PowerTech
PowerTech AC8038 quick start guide

HaiLin Controls
HaiLin Controls A2203 Installation and operating instructions

ensto
ensto eVahti Operation & installation instructions