INTRODUCTION
Thank you for purchasing our Heater/Humidifier GHH100 each individual unit has
been manufactured to ensure safety and reliability to bring you many years of
personal comfort. Please read the following instructions carefully before operating
your new Heater/Humidifier and be sure to keep this manual for further reference.
IMPORTANT SAFEGUARDS
• Do not use the heater in the immediate surroundings of a bath, shower,
swimming pool or any water sources. Do not use outdoors.
• Do not use the appliance to dry any object or obstruct the air inlet and outlet
vents.
• Do not place the heater near heating devices, aerosols or materials sensitive to
heat. Do not place the appliance near any object which may be drawn into the air
inlet vent.
• Do not insert any objects into the inlet or outlet vents.
• Ensure that water is not spilled on the appliance at any time.
• Ensure the mains lead cannot be tripped over or pulled such that the heater
would tip or fall over.
• Do not remove the plug by pulling on the main cord.
• The fan heater must not be located immediate below a socket – outlet.
• Do not use this fan heater with a programmer, timer or any other device that
switches the heater on automatically, since a fire risk exists if the heater is
covered or positioned incorrectly.
• Only use the fan heater with it standing on its base or using the mounting bracket.
• Always turn the appliance off, unplug it and allow the whole unit too cool down
before moving the unit, cleaning it or whenever it is not in use.
• Do not allow children to use the appliance, keep it out of their reach.
• Keep the appliance out of reach of animals.
• Ensure that the plug is fully pushed into the socket and correctly engaged before
using the unit.
• Do not let the main cord touch hot surfaces and avoid twisting or kinking it.
• If power supply cord or product becomes damaged, in order to avoid potential
hazards do not use the appliance but return it to Goldair (see warranty for details)
• Do not operate the humidifier without water in the tank, or water level is lower
than the minimum requirement.
• Use only clean, cool tap water to fill tank. Do not add scented oils or chemicals to
the water tank.
• Care should be taken when pouring water into the tank.
• Use a cup or container to fill the water tank, if water is spilled on the appliance
accidentally, do not use the appliance until it is absolutely dry.
• Ensure the appliance is turned off, unplugged and absolutely cold before filling
the tank.
• Ensure that the vapor cover/outlet is closed before turning on the humidifier.
• Do not touch the vapor cover/outlet when the humidifier is in operation.
• Do not block the vapor cover/outlet.
• Do not place the appliance in a position where the mist will come into direct
contact with furniture, carpets, curtains or walls.
• Do not attempt to use the humidifier if the water is frozen, allow it to thaw at room
temperature.

GETTING TO KNOW YOUR HEATER/HUMIDIFIER
1. Power light 2. Thermostat control
3. Main control 4. Air outlet grille
5. Air inlet grille 6. Hanger
7. Handle 8. Water level indicator
9. Vapor cover/outlet 10. Water outlet
POWER LIGHT (1)
When illuminated, indicates that the heater or humidifier is powered. When
extinguished, indicates that the unit has been switched off.
MAIN CONTROL (3)
This Control is used to turn your Heater/Humidifier ON or OFF. Also, there are other
functions for the control and they are shown as follows:
Position Functions
I OFF
II Activate the fan only (for Summer use)
III Activate the heater to medium heat
IV Activate the heater to maximum heat
V Activate the humidifier and the fan
VI Activate the humidifier & heater with medium heat
VII Activate the humidifier & heater with maximum heat

THERMOSTAT CONTROL (2)
The heat output is controlled by the thermostat, according to room temperature. Set
the dial to the number you wish (* is the minimum “approximately 6oC, and 10 is the
maximum “ approximately 35oC”). When the room temperature is reached, the
heater will turn off automatically to maintain your selected temperature. When the
temperature drops, the thermostat will click on the appliance again. The appliance
will keep turning ON and OFF. The turning off position “O” on the main control must
be selected in order to shut down the unit permanently.
WATER TANK
The water tank for the humidifier is located inside the fan heater, which can not be
removed. The fill the water tank :
1) Turn the unit off, unplug the main cord and allow the whole appliance to cool
down.
2) Open the vapor cover/outlet (9) carefully add cold tap water into the water inlet.
3) When the water level indicator is showing maximum stop adding water into the
tank and close the vapor cover/outlet.
Note: when the water is filled exceeding the maximum level, excess water will pour
out from the water drain outlet (10). Do not add water into the tank by
placing the fan heater directly under the tap.
MOUNTING THE FAN HEATER ON A WALL
A mounting bracket (6) is provided for each individual unit, two 4mm diameter screws
are needed for fixing the bracket on a wall “the flat side of the bracket face to the
wall” and ensure that the bracket is fixed on the wall firmly. The fan heater can then
be hung by placing the handle (7) on the bracket. Also, the fan heater must be
installed at least 1.8m above the floor.
CLEANING
When the unit is used daily, weekly cleaning is recommended. Regular cleaning also
prevents dust accumulation within the inlet and outlet vents.
Before cleaning your fan heater, turn off the heater and disconnect it by removing the
plug from the power supply socket and allow the unit to cool. Do not use detergents
or abrasive to clean any parts of the unit, then wipe with a dry cloth to remove dust
on the vents and a damp cloth (not wet) clean off the stains be careful not to allow
moisture into the heater.

TROUBLE SHOOTING
Trouble Probable Cause Solution
Power light does not
illuminate a) Appliance is not plugged
in.
b) Appliance is not turned
on.
c) Power supply cord or
unit damaged.
Plug in unit
Check the position of the
main control
Return it to an authorised
service agent or retailer for
replacement.
Fan heater is not
functioning a) Fan heater is not turned
on.
b) Room temperature is
warm enough to switch
off the unit
c) Air inlet or outlet vent
being obstructed.
Check the position of the
main control.
Set the thermostat control dial
to a higher number.
Switch off the unit, unplug it
and allow it to cool down, then
turn on the unit again. If the
heater is still not functioning,
return it to an authorised
agent for repair
No vapor is produced
from the humidifier a) No water in the tank.
b) The main control is not
selected in the appropriate
position
Add water into the tank (see
instructions)
Check the position for the
main control
STORAGE TIPS
If you do not plan to use your Heater/Humidifier for an extended period of time (i.e.
during the summer months), it is important that you follow these instructions to help
prevent stagnation of water in the unit.
1. Clean your Fan Heater as instructed in the section titled “Cleaning”.
2. Make sure all water is emptied from the tank. Water can be poured out from
either the vapor cover/outlet (9) or the water outlet (10). Before doing this,
ensure that the power plug is disconnected.
3. Dry the unit thoroughly.
4. Pack your fan heater in its original carton and store in a cool, dry place.

TECHNICAL SPECIFICATIONS
Dimensions:
Length: 24.5cm
Width: 29.0cm
Height: 34.4cm
Angle of Air Outlet: 130o(simultaneously)
Average Air Output: 200m3/hour
Input Voltage: 230V/50Hz
Power Consumption: 2200W
CONNECTION TO THE MAINS SUPPLY
The wires in the mains lead are coloured in accordance with the following code:
BROWN - LIVE (L)
BLUE - NEUTRAL (N)
GREEN/YELLOW - EARTH (E)
As the colours of the wires in the mains lead of this appliance may not correspond with the
coloured markings identifying the terminals in your plug, proceed as follows:
• The BLUE wire is the NEUTRAL and must be connected to the terminal
which is marked with the letter N or coloured BLACK
• The BROWN wire is the LIVE and must be connected to the terminal
which is marked with the letter L or coloured RED.
• The wire which is coloured GREEN/YELLOW must be connected to the
terminal which is marked E or coloured GREEN or GREEN/YELLOW.
Always ensure that the cord grip is positioned and securely fastened.
WARNING: THIS APPLIANCE MUST BE EARTHED.
WIRING FOR A 13AMP PLUG
Table of contents
Popular Humidifier manuals by other brands

GeneralAire
GeneralAire GF-1000LHM Installation & owner's manual

FOGLESS
FOGLESS SPIRO Instructions for use

AromaRoom
AromaRoom HU5003 instruction manual

SPX Cooling Technologies
SPX Cooling Technologies Class Cooling Tower brochure

HoMedics
HoMedics UHE-CM45 instruction manual

TaoTronics
TaoTronics TT-AH001 user manual