golmar ART 1 G2+ User manual

TECHNOLOGY
USER MANUAL
Code 50122529 T G2 EART 1/ + N REV.02 12
ART 1 G2+ TERMINAL

INTRODUCTION
First of all, we thank and congratulate you for purchasing this product.
Our commitment to achieving the satisfaction of customers like you is manifested through our ISO-9001 certification
and the manufacture of products like the one you have just purchased.
Its advanced technology and strict quality control will ensure that customers and users enjoy the numerous features
that this device offers. To get the most out of them and ensure proper operation from day one, we recommend that you
read this instruction manual.
CONTENTS
2
Introduction............................................................................................................................................... .........2...........
Contents.......................................................................................................................................................................2.
Safety precautions........................................................................................................................................... ............. .2
Characteristics...............................................................................................................................................................3
System operation......................................................................................................................................... 3..................
Description of the terminalART 1/G2+ ..............................................................................................................................
................................................................................................................................................................. 4.
Description
................................................................................................................................................ .4........ .Function buttons
Push button status LED........................................................................................................................................... .... 4
............................................................................................................................................ ...4... .
Connection terminals
................................................................................................................................................................. ..5DIP switch
................................................................. ............... 5-8Configuration of terminal address codes (up to 128 addresses)
..................................................................... .................................................... .... .................. 9.Autoswitch-on function
................................................................................................................................... ... ................ .. 9.Intercom function
Automatic door opening mode.....................................................................................................................................9
.
Light activation function (staircase light)......................................................................................................................9
Setting audio volume in the terminal............................................................................................................................9
.
.
Setting call tone volume & .............................................................................................9'Do not disturb' mode function
....................................................................................................................10Configuration & selection of the call tone
Tones & volume call tones to default value :...............................................................................................................10' '
Cancel the call forwarding process.......................................................................................................................... 10.' '
ART 1/G2+ terminal installation.................................................................................................................................. ... ...
........................................................................................................................................11
In wall mounting connector
................................................................................................................................................ ... 12.. .In embedding box
Wiring diagrams..................................................................................................................................... .. . 13............. ..... .
Cleaning the monitor....................................................................................................................................................14
Not s.......................................................................................................................................................................... 15e .
Compliance................................................................................................................................................................ 16..
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
SAFETY PRECAUTIONS
-Always disconnect the power supply before making modifications to the device.
-The fitting and handling of these devices must be carried out by .authorised personnel
-The wiring must run at least .40cm away from any other wiring
-Do not overtighten the screws on the connector.
-Install the terminal in a dry protected location free from the risk of dripping or splashing water.ART 1/G2+
-Do not place in humid, dusty or smoky locations, or near sources of heat.
-Before connecting the device to the mains, check the connections between the door panel, power supply & ART 1/G2+
terminals.
-Always follow the instructions contained in this manual.

3
CHARACTERISTICS
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
- hands-free audio terminal with simplified installation (non-polarised 2 wire bus).ART 1
- Up to 4 terminals/monitors per apartment (master, slave 1, slave 2 and slave 3).ART 1
- Up to 32 apartments/ART 1 terminals in mixed installations with monitors .(EL632 G2+ SE module)
- Up to 128 apartments/ terminals per installationART 1 (EL6 2 G2 sound module required).4 +
- Completely private conversation.
- Call reception volume control: min, med, max and off (do not disturb).
-Audio volume control during communication process (4 different levels).
- nput for calls from door."HZ" i apartment front
- Output to auxiliary call repeater (maximum 50mA/12Vdc).
- ifferent ringtones to identify the origin of the call (door panel, intercom or door of theUp to 6 d , guard monitor front
apartment).
- Button for starting/stopping communication. In standby: 2 short press to "intercom" calls (within the same apartment)
and press for 3 seconds to "autoswitch-on" function.
- Button for lock release 1 activation. In standby: activate/ deactivate "Doctor mode".
- Button for lock release 2 activation/ staircase light activation (SAR-G2 SAR-12/24 modules required).+ &
- Button for tone call volume control, "do not distrurb" mode/ configuring ringtones/ communication call volume control
(ART 1 speaker) & in case of call forwarding, cancel call transfer (withART 7W monitor).
- Button for guard monitor calls (if exist).
- DIP switches for setting the terminal's address (call code), master/slave and end of line.
SYSTEM OPERATION
-To make a call, the visitor needs to press the button for the apartment, an audible tone indicates that the call is being
made and LED on the door panel illuminates. If vocal synthesis is enabled, a 'Call is in progress' message appears
indicating that a call is being made. At this moment, the apartment's terminal(s) receives the call. If another apartment
is called by mistake, press the button for the correct apartment and the first call will be cancelled.
- Upon receiving the call, the push button LED of the terminal(s) will blink white. If the call is not answered within 40
seconds, LED will turn off and the channel will be freed.
- Door panel LED will turn off and theTo establish communication, press button on any terminal in the apartment.
led turn onwill .
-Communication will last for one and a half minutes or until button is pressed again. When communication has
finished, LED will turn off and the channel will be freed. If vocal synthesis is , a 'Communicationdoor panel enabled
is finished' message will indicate that the call is over.
-To open the door, press button (if it exists and, to open the second door, press button ) during the call or
communication processes: one press activates the lock release for seconds and LED on the door panel will also3
illuminate for seconds. If vocal synthesis is enabled, a 'Door en' message will be indicated on the door panel.3 is op
-Description of the function buttons can be found on p .age 4

TERMINAL DESCRIPTION:
4
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
Funtion push button:
Descrip i n:t o
DIP 8,9
00 - Master
10 - Slave 1
OFF = 0 | ON = 1
01 - Slave 2
11 - Slave 3
DIP 1 to 7
Monitor address
DIP 10
End of line resistor
SA
BUS HZ GND
GOLMAR S.A. C/ Silici, 13. 08940-SPAIN
ART 1/G2+
12210140
V03
MADE IN CHINA
WARNING TO PREVENT
FIRE OR ELECTRIC SHOCK,
DON’T EXPOSE THIS DEVICE
TO RAIN OR MOISTURE
g
i
a.
b.
c.
Speaker.
Function push buttons.
Raised dots for the visually impaired people.
In call m tion:/ com unica
Above this raised dot is the "Start/ End
communication" button.
Above these raised dots is the "Door openning"
button.
f
Micr .ophone
Wall mounting connector fixing (x4).
Configuration switches.
Golmar use.
Bus connections terminals.
Apartment front door button input .
"HZ"
Auxiliary call repeater output (m x 50mA/12V ).a . dc
d.
e.
f.
g.
h.
i.
j.
b
b
a
d
c
e
h
e
AUX
b
j
Start/stop communication button. 2 shortIn standby:
press to "intercom" call (within the same apartment)
and press for 3 seconds to "autoswitch-on" function.
See page 9-10.
In standby: short press, it allows to change tone call
volume, on every short press terminal reproduces
the selected volume (cyclic min/ med/ max/ off"do
not disturb"). on every shortIn communication:
press, it allows to change the speaker of the ART 1
audio volume (cyclic 4 audio levels). See p. 9-10.
- : Led will blink (white color).During call door panel, guard or intercom process
Terminal in communication: Led switch on (white color).
- : Led switch on (red color)."Do not disturb" mode
Call forwarding process (withART 7W monitor): Led blink (red color).
"Default tones & tones volume": Led blink 5 times (red color).
- Led switch on (red color)."Doctor mode":
HZ: ( )Black
Funtion push button status LED:
Descrip terminals:tion connection
During the call or communication processes: one press
will activate the lock release : press the2. In standby
button for 3 sec. to activate the staircase light the( SAR-
G SAR-12/24 ).2+ & modules required 5 short press to
default tones & tones volume (led blink 5 times). See
page 9-10.
HZ: ( ed)R
GND: (Black)
SA: ( ed)R
During the call or communication processes: one press
will activate the lock release . : press theIn standby1
button for 5 sec. to activate/deactivate the "Doctor
mode" function. See page 9-10.
BUS, BUS: Communication BUS (non-polarised).
SA, GND:Auxiliary call repeater output (max 50mA/12V ), relay SAR-12/24.dc
HZ, HZ: Apartment front door button input:
Connect only on the master monitor. The signal received is then transmitted
to the slave monitors in the same apartment through the BUS.
Note: HZ push button function mode: When HZ push button is pressed will be call tone and activate the output of
auxiliary call repeater with standby terminal, call process, communication process (HZ tone with lower audio level),
intercom process and "Do not disturb" mode. Important: Up to 8 terminals/ apartments with push button "HZ"
activated at the same time (with system and terminals in standby).
BUS
BUS

5
Description of the DIP switch and configuration of the terminal address (code):ART 1/G2+
TERMINAL DESCRIPTION:
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
Edificio / Chalet (Placa Nexa)
Dip1 Dip :- 7 Note:terminals 1 128 Mixed installations with monitors (addresses 1 to 32).Sets the address (addresses to ).
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
terminal code is the sum of the values of the switches set to ON.
.
.
Dip -Dip :8 9 terminal only terminalThese define whether the is master or slave. Each apartment must have one master .
Master Slave 1 Slave 2 Slave 3
.
Dip :10 Configures the end of line. In installations with terminals only, it must always be in the OFF position. In mixed
installations of monitors with terminals in the same apartment, set to ON for the terminals in which the BUSART 1/G2+
cable ends and leave in the OFF position for intermediate terminals.
IIMPORTANT: ART 1/G2+ terminal in , see corresponding Kit Soul userVilla installation with SOUL door panel
manual for Kit features as maximum number of apartments and monitors/ART 1 G2+ terminals.
1 2 3
ON
Ejemplo: 0+ 0+4+0+16+ = 200+0
Interruptor nº: 1 2 3 4 5 6 7
Valor en ON: 1 2 4 8 16 32 64
Tabla de valores
4 5 6 7 8
Importante:
Vivienda 1 (Dip1 a ON y Dip2-Dip7 a OFF)
Vivienda 128 (Dip1-Dip7 a OFF) 910
123
ON
4 5 6 7 8 9 10 1 2 3
ON
4 5 6 7 8 9 10 123
ON
4 5 6 7 8 9 10 1 2 3
ON
4 5 6 7 8 9 10
Important:
- Up to 32 apartments/ART 1 terminals in mixed installations with monitors .(EL632 G2+ SE module)
- Up to 128 apartments/ terminals per installationART 1 (EL6 2 G2 sound module required).4 +
Configuration of terminal address codes (up to 2 addresses):ART 1/G2+ 1 8
Dip1 a Dip7: .To configure the terminal/apartment address (up to 2 addresses)ART 1/G2+ 1 8
Apartment code 1Apartment code 2Apartment code 3Apartment code 4
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 5
1 2 3
ON
4 5 6 7
Apartment code 6Apartment code 7Apartment code 8
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 9
1 2 3
ON
4 5 6 7
Apartment code 10 Apartment code 11 Apartment code 12
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 13
1 2 3
ON
4 5 6 7
Apartment code 14 Apartment code 15 Apartment code 16
Continued overleaf
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
ON
1234567

Continued from previous page.
6
TERMINAL DESCRIPTION:
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
Apartment code 21
1 2 3
ON
4 5 6 7
Apartment code 22 Apartment code 23 Apartment code 24
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 25
1 2 3
ON
4 5 6 7
Apartment code 26 Apartment code 27 Apartment code 28
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 29
1 2 3
ON
4 5 6 7
Apartment code 30 Apartment code 31 Apartment code 32
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 33
1 2 3
ON
4 5 6 7
Apartment code 34 Apartment code 35 Apartment code 36
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 37
1 2 3
ON
4 5 6 7
Apartment code 38
Apartment code 39 Apartment code 40
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 45
1 2 3
ON
4 5 6 7
Apartment code 46 Apartment code 47 Apartment code 48
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 49
1 2 3
ON
4 5 6 7
Apartment code 50 Apartment code 51 Apartment code 52
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 53
1 2 3
ON
4 5 6 7
Apartment code 54 Apartment code 55 Apartment code 56
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 57
1 2 3
ON
4 5 6 7
Apartment code 58 Apartment code 59 Apartment code 60
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 41
1 2 3
ON
4 5 6 7
Apartment code 42 Apartment code 43 Apartment code 44
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 17 Apartment code 18 Apartment code 19 Apartment code 20
ON ON ON
1234567 1234567 1234567
1 2 3
ON
4 5 6 7
Continued overleaf

Continued from previous page.
Continued overleaf
7
TERMINAL DESCRIPTION:
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
Apartment code 65
1 2 3
ON
4 5 6 7
Apartment code 66 Apartment code 67 Apartment code 68
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 69
1 2 3
ON
4 5 6 7
Apartment code 70 Apartment code 71 Apartment code 72
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 73
1 2 3
ON
4 5 6 7
Apartment code 74 Apartment code 75 Apartment code 76
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 77
1 2 3
ON
4 5 6 7
Apartment code 78 Apartment code 79 Apartment code 80
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 81
1 2 3
ON
4 5 6 7
Apartment code 82 Apartment code 83 Apartment code 84
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 89
1 2 3
ON
4 5 6 7
Apartment code 90 Apartment code 91 Apartment code 92
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 93
1 2 3
ON
4 5 6 7
Apartment code 94 Apartment code 95 Apartment code 96
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 97
1 2 3
ON
4 5 6 7
Apartment code 98 Apartment code 99 Apartment code 100
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 101
1 2 3
ON
4 5 6 7
Apartment code 102 Apartment code 103 Apartment code 104
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 85
1 2 3
ON
4 5 6 7
Apartment code 86 Apartment code 87 Apartment code 88
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 61 Apartment code 62 Apartment code 63 Apartment code 64
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
1 2 3
ON
4 5 6 7

Continued from previous page.
8
TERMINAL DESCRIPTION:
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
Apartment code 105 Apartment code 106 Apartment code 107 Apartment code 108
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 109
1 2 3
ON
4 5 6 7
Apartment code 110 Apartment code 111 Apartment code 112
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 113
1 2 3
ON
4 5 6 7
Apartment code 114 Apartment code 115 Apartment code 116
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 117
1 2 3
ON
4 5 6 7
Apartment code 118 Apartment code 119 Apartment code 120
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
Apartment code 121
1 2 3
ON
4 5 6 7
Apartment code 122 Apartment code 123 Apartment code 124
Apartment code 125
1 2 3
ON
4 5 6 7
Apartment code 126 Apartment code 127 Apartment code 128
123
ON
4567 123
ON
4567 123
ON
4 5 6 7
123
ON
4567 123
ON
4 5 6 7 1 2 3
ON
4567123
ON
4 5 6 7

9
TERMINAL DESCRIPTION:
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
Intercom function:
Intercom functionality between two points in the same apartment comes as standard with the ART 1/G2+ terminal.
The terminal must be in standby to make intercom calls.
To make an intercom call, press button two short times the on button of the terminal that makes the intercom, led
call and the terminals that receive the call will blink and some tones in the apartment terminals will confirm that the call
is being made.
The call needs to be answered within 40 seconds.
To establish communication, press button of any called terminal of the apartment (if there is more than one slave terminal),
the led of the button of the terminals in communication will turn on and the rest of the terminals of the apartment the led of
the button will turn off.
C munication will last for one and a half minutes or until button is pressed againom .
Autoswitch-on function:
With the ART 1/G2+ terminal in standby mode, you can establish an audio communication with the master door panel. It
is only operative if there is no communication in progress.
With the terminal in standby mode, press the button for 3 seconds, a confirmation tone will sound and the led of the
button on the terminal will turn on, indicating that audio communication has been established with the master door panel.
The communication will last for one and a half minutes or until the botton is pressed again.
Setting audio volume in the terminal:
Setting call tone volume & :'Do not disturb' mode function
The terminal must be in standby mode to adjust the volume of the call tone or to activate/deactivate the "do not disturb" mode.
A short press on the button allows you to change the volume of the call tone, each short press reproduces the selected
volume (minimum/ medium/ maximum and no volume in "do not disturb" mode), stop pressing once the "do not disturb"
mode has been selected (the LED on the button turn on in red) or the volume of the desired call tone.
If the "do not disturb" mode has been selected, the LED on the button will turn on (red), indicating that the "do not disturb"
mode is active. The terminal will not sound the ring tone when a call is received (see note "HZ" on page 4).
To deactivate the "do not disturb" mode, press the button , each short press reproduces the selected volume
(minimum/ medium/ maximum and no volume "do not disturb" mode), stop pressing once the volume (minimum/
medium or maximum) of the desired call tone has been selected; the LED on the button will turn off indicating that
the "do not disturb" mode is deactivated.
TheART 1/G2+ terminal allows you to activate/deactivate the "automatic door opening" mode.
Activate "automatic door opening" mode:
With the terminal in stand-by mode, press the button for 5 seconds, a confirmation tone will sound and the led of the
button on the terminal will turn on (red), indicating that the "automatic door opening" mode has been activated (3
seconds after receiving a call from the door panel).
Deactivate "automatic door opening" mode
With the terminal in stand-by mode, press the button for 5 seconds, a confirmation tone will sound and the led of the
button on the terminal will turn off, indicating that the "automatic door opening" mode has been deactivated.
“Automatic door opening” mode:
Light activation function:
TheART 1/G2+ terminal must be in standby for light activation (requires SAR-G2+ and SAR-12/24 module).
To activate the light (e.g. "staircase light"), press the button for 3 seconds until you hear 2 confirmation tones
indicating that the light has been activated.
Important: For connection and configuration, see TSAR-G2+ and TSAR-12/24 manual.
The terminal allows you to change the volume of the audio in the speaker of the communicating terminal (between 4
levels from minimum to maximum in carousel mode) through the function button .
The terminal must be in communication, a short press on the button , allows to change the audio volume on the
terminal speaker, each short press the selected volume (between 4 levels from minimum to maximum and
reproduces
in carousel mode), stop pressing once the desired volume level is selected on the terminal. When communication has
finished, the selected volume will be saved in the terminal.
Continued overleaf

10
TERMINAL DESCRIPTION:
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
To modify the call tones, press the button for 3 seconds until you hear 3 confirmation tones that indicate that the
terminal is in configuration mode. Once in configuration mode, press the corresponding button to change the call tone
(between 6 different ring tones and in carousel mode):
- To change the “" (HZ) call tone, press the button .
apartment front door button
Each short press on the button reproduces a different call tone, stop pressing once you have selected the desired
" " call tone on the terminal.apartment front door button
- To change the “intercom”call tone, press the button .
Each short press on the button reproduces a different call tone, stop pressing once you have selected the desired
" " call tone on the terminal.intercom
- To change the “guard monitor”call tone, press the button .
Each short press on the button reproduces a different call tone, stop pressing once you have selected the desired
" " call tone on the terminal.guard monitor
- To change the door panel call tone, press the button .
Each short press on the button reproduces a different call tone, stop pressing once you have selected the desired door
panel call tone on the terminal.
To exit and save the selected call tone in the terminal, press the button for 3 seconds until you hear 2 confirmation tones
indicating that the terminal has saved and left the configuration mode.
Make a call to check that the terminal has been configured with the desired call tones.
Configuration & selection of the call tone:
The terminal must be in standby mode for the configuration and selection of the desired call tone.
Cancel the call forwarding process:' '
TheART 1/G2+ terminal allows you to restore the tones and volume of the call tones to "default value".
With the terminal in standby mode, 5 short presses on the button , 3 confirmation tones and the led of the button of
the terminal will blink 5 times, indicating that the tones and volume of the call tones in the terminal have been restored
to their default value.
Tones & volume call tones to default value:
Continued from previous page.
If a call is made from the door panel to an apartment of a mixed video door entry system (ART 7W/G2+ monitors and
ART 1/G2+ terminals in the same apartment) and the ART 7W/G2+ monitor has "call forwarding" configured and
activated; from an ART 1/G2+ terminal in the same home, you can cancel the process of "call forwarding" to a mobile
phone by pressing the button on the terminal for more than 3 seconds (information about this function, see the
TART 7W G2+ manual).

INSTALLING THE TERMINAL IN A WALL MOUNTING CONNECTOR
The top of the wall mounting connector should be located at a height of 1.60m from the ground. The minimum distance
between the wall mounting connector and the closest object must be 5 cm.
Positioning the wall mounting connector:
Fix the terminal's wall mounting connector to the wall by drilling two 6mm diameter holes and using the screws and
plugs supplied with the terminal.
Fixing the terminal's wall mounting connector to the wall:
Positioning the terminal:
Avoid dusty or smoky environments or locations near sources of heat.
11
Connect the cables to the terminal (see p. 4), position the terminal in front of the wall mounting connector, ensuring that
the holes in the base of the terminal line up with those on the connector , and then move the terminal
downwards until the terminal is securely fixed to the connector .
Remember to remove the protective covering from the front of the terminal once installation has been
completed.
1
23
1.60m
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
2 3
x4 30
1

INSTALLATION OF THE TERMINAL IN AN EMBEDDING BOX
Make a hole in the wall to position the top of the universal embedding box at a height of 1.60 m from the ground. The
minimum distance between the sides of the embedding box and the closest object must be 5 cm.
Positioning the embedding box:
1.60m
Pass the cable through the hole made in the embedding box. Embed the box and ensure that it is level and flush.
Fix the wall mounting connector of the terminal to the embedding box with the screws supplied.
Positioning the embedding box and fitting the wall mounting connector:
Positioning the terminal:
Avoid dusty or smoky environments or locations near sources of heat.
12
Connect the cables to the terminal (see p. 4), position the terminal in front of the wall mounting connector, ensuring
that the holes in the base of the terminal line up with those on the connector , and then move the terminal
downwards until the terminal is securely fixed to the connector .
Remember to remove the protective covering from the front of the terminal once installation has been
completed.
1
23
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
Screws supplied with
the embedding box.
2 31

WIRING DIAGRAMS
13
For more information about the door panel, installation, configuration, connection of an AC lock release, 2nd lock release mixed installation,
ART 1/G2+ and other wiring diagrams ( )with monitors and terminals , see the corresponding door panel manual .
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
Audio door entry system with 128 apartments / ART 1-G2+ terminals Golmar .and d.c lock release
Only audio installation, configure
the end of line ni
Dip 10 OFFto all
audio terminals. AP
(1)
(1)
*
( )
NA2
+AP-
C1 NA1AP+ C2
AP+
GND
BUSBUS
Relé 2Relé 1
_
12Vdc
NC2
CCTV
Distances and cross-sections:
Mains
100~240Vac
BUS (M) BUS(PL)
FA-G2+
LN
Access door panel
1 2 3 4 5 6 7 8 910
ON
ART 1/G2+
AUX
APARTMENT 2
ON
1 2 3 4 5 6 7 8 9 10
BUS BUS BUS
*
( )
ART 1/G2+
AUX
APARTMENT 4
ON
1 2 3 4 5 6 7 8 9 10
*
( )
ART 1/G2+
Master
AUX
APARTMENT 128
ON
1 2 3 4 5 6 7 8 9 10
*
( )
A
E
C
FA- 2G +
ART 1
AUX
ART 1
AUX
ART 1
AUX
ART 1
AUX
D
B
A B
80m 20m
Cable C
96m
RAP-GTWIN/HF 2x1mm
2
D
15m
B+C+D
130m
E
15m
ART 1/G2+
AUX
APARTMENT 1
ON
1 2 3 4 5 6 7 8 9 10
BUS BUS BUS
ART 1/G2+
AUX
APARTMENT 3
ON
1 2 3 4 5 6 7 8 9 10
ART 1/G2+
AUX
APARTMENT 127
ON
1 2 3 4 5 6 7 8 9 10
Make the connections in
electrical junction box.
B: must be 20m.to
D: 15m.must be to
Important:
*
( )
*
( )
*
( )
Master
Master
Master
Master Master
Lock release
a dm x. 12 V c/270mA.
1
( )

CLEANING THE TERMINAL
14
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
- Do not use solvents, detergents or cleaning products that contain acids, vinegar or abrasive components.
- Use a soft damp lint-free cloth with water.
-Always wipe the in the same direction, from top to bottom.terminal
-After cleaning the , remove any moisture with a soft dry lint-free cloth.terminal
AUX

NOT S:E
15
ART 1/G2+ HANDS-FREE AUDIO TERMINAL

CO :MPLIANCE
Este producto es conforme con las disposiciones de las Directivas Europeas aplicables respecto a
la Compatibilidad Electromagnética 20 4/ /CEE1 30 .
This product meets the essentials requirements of applicable European Directives regarding
Electromagnetic Compatibility 20 4/ /ECC1 30 .
NOTA: El funcionamiento de este equipo está sujeto a las siguientes condiciones:
(1) Este dispositivo no puede provocar interferencias dañinas, y (2) debe aceptar
cualquier interferencia recibida, incluyendo las que pueden provocar un funcionamiento no
deseado.
NOTE: Operation is subject to the following conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any
received interference, including the ones that may cause undesired operation.
golmar@golmar.es
www.golmar.es
Sistemas de comunicación S.A.
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis.
Golmar reserves the right to make any modifications without prior notice.
GOLMAR S.A.
C/ Silici, 13
08940- Cornellá de Llobregat
SPAIN
16
ART 1/G2+ HANDS-FREE AUDIO TERMINAL
Other manuals for ART 1 G2+
2
Table of contents