SYSTEM OPERATION
6
Please adhere to the following warnings and cautions when
installing, adjusting, altering, servicing, or operating the
furnace.
REVE ERS IJURR E UE IMRERISI
JUSME ERI SERVIE RMIEE REER IS
MUR II SSISERIRMISU
QUIIE ISERSERVIE ER E SSUIER
REVE SSIE RER ME ERS IJURR E
UE EERI SK EUREMUS EE RE
EEERI MES RMWER
Discharge your body’s static electricity before touching
unit. An electrostatic discharge can adversely aect electrical
components.
Use the following precautions during furnace installation
and servicing to protect the integrated control module from
damage. By putting the furnace, the control, and the person
at the same electrostatic potential, these steps will help
avoid exposing the integrated control module to electrostatic
discharge. This procedure is applicable to both installed and
uninstalled (ungrounded) furnaces.
1. Disconnect all power to the furnace. Do not touch the
integrated control module or any wire connected to the
control prior to discharging your body’s electrostatic
charge to ground.
2. Firmly touch a clean, unpainted, metal surface of the
furnace near the control. Any tools held in a person’s
hand during grounding will be discharged.
3. Service integrated control module or connecting wiring
following the discharge process in Step 2. Use caution
not to recharge your body with static electricity; (i.e., do
not move or shue your feet, do not touch ungrounded
objects, etc.). If you come in contact with an ungrounded
object, repeat Step 2 before touching control or wires.
4. Discharge any static electricity from your body to ground
before removing a new control from its container. Follow
Steps 1 through 3 if installing the control on a furnace.
Return any old or new controls to their containers before
touching any ungrounded object.
This product is designed for use as a residential home gas
furnace. It is designed or certied for use in mobile home,
trailer, or recreational vehicle applications.
In the U.S.A., this furnace can be used in the following non-industrial
commercial applications: Schools, Oce buildings, Churches, Retail
stores, Nursing homes, Hotels/motels, Common or oce areas. In
all applications, the furnace must be installed per the installation
instructions.
Goodman®brand GMES96*U and Amana®brand AMES96*U
furnaces are ETL certied. All *MES96*U furnaces are built
for use with Natural gas only & may not be converted for use
with LP gas.
Goodman®brand GMES96*U and Amana®brand AMES96*U
high eciency furnaces are dual certied. Dual certication
means that the combustion air inlet pipe is optional and the
furnace can be vented as a:
• Non-direct vent (single pipe) central forced air furnace
in which combustion air is taken from the installation
area or from air ducted from the outside or,
• Direct vent (dual pipe) central forced air furnace in
which all combustion air supplied directly to the furnace
burners through a special air intake system outlined in
this manual and the installation instructions.
To ensure proper installation, operation and servicing,
thoroughly read the installation and service manuals
for specics pertaining to the installation, servicing and
application of this product.
SSIE RER MEERSIJUR R E UE IRE
EXSI SMKE SESI EERI SK RR
MXIEM RESU RMIMRERISIREIR ERI
RMIEE IS RU
REVE RER ME ERS IJUR R E UE IRE
IS IS UREI MIE ME RIER RREREI
VEIE
To ensure proper furnace operation, install, operate, maintain
and service the furnace in accordance with the installation,
operation and service instructions, all local building codes
and ordinances. In their absence, follow the latest edition of
the National Fuel Gas Code (NFPA 54/ANSI Z223.1), and/or
CAN/CGA B149 Installation Codes, local plumbing or waste
water codes, and other applicable codes.
A copy of the National Fuel Gas Code (NFPA 54/ANSI Z223.1)
can be obtained from any of the following:
American National Standards Institute
25 West 43rd Street, 4th Floor
New York, NY 10036