EN
1) Function not available for all products.
Override
HEATINGHOT WATER
Extra Hour
Mode
DAY/ CH RUN
TIME
OFF
am
Thu
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
07 / 02 / 2013
ON1
OFF
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
ON1
DHW
Override
Extra Hour
Mode
OK
Holidays
Select
1)
1)
Override
HEATINGHOT WATER
Extra Hour
Mode
DAY/ CH RUN
TIME
OFF
am
Thu
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
07 / 02 / 2013
ON1
OFF
AUTO
ONCE
CONT
EXT HOUR
+1
+2
+3
ON1
DHW
Override
Extra Hour
Mode
OK
Holidays
Select
Operating Manual
QEG-2
QEG-2S
Installation und Montage
Operation and confi guration
Safety Instructions
• To avoid injuries, the device must be installed by a skilled
electrician only!
• Before changing the battery, the device must be disconnected
from the power supply!
• Please observe the national regulations and safety instructions.
• Interferences and changes to the device will invalidate the
warranty and guarantee rights.
• Maximum diameter of the conductors lines for the
terminals: 2 x 2,5 mm2
Read and observe these instructions to guarantee a perfect function
of the device and a safe operation.
Information about the device
What is a programmer?
...an Explanation for Householders (as recommended by the Energy
Savings Trust)
Programmers allow you to set ‘ON’ and ‘OFF’ time periods. Some
models switch the central heating and domestic hot water on and
off at the same time, while others allow the domestic hot water and
heating to come on and go off at different times.
Set the ‘ON’ and ‘OFF’ time periods to suit your own lifestyle. On
some programmers you must also set whether you want the heating
and hot water to run continuously, run under the chosen ‘ON’ and
‘OFF’ heating periods, or be permanently off.
Danger! Risk of electric shock!
Installation must be carried out by a
professional electrician!
WARNING
Installation and mounting
Danger! Risk of electric shock!
Installation must be carried out by a
professional electrician!
WARNING
NL1234
NCH
OFF
CH
ON
HW
ON
HW
OFF
230 V / 50-60 Hz
timeswitch /
programmer
wallplate
L
Commissioning
When rst using the timer, you have to set programming type,
date and time.
PROG TYPE
DAY
MONTH
YEAR
HOUR
MINUTE
DONE
1. Connect the programmer to power.
Product name and version number are displayed brie y.
The preset PROGRAMMING TYPE and OK are ashing.
Depending on the product you can choose between three different
settings: Daily, Weekly 1) or Week-Weekend 1).
Daily All days (Monday - Sunday) are programmed
with the same ON/OFF time schedule
Weekly 1) You can program each day (Monday, Tuesday,
...) with a different ON/OFF time schedule
Week-Weekend 1) You can program Monday - Friday with a ON/
OFF time schedule and Saturday - Sunday with
a different one.
2. Choose your desired programming type (DAILY, WEEKLY 1),
WEEK-WEEKEND 1)), or , and con rm with .
Preset value DATE is ashing.
3. Enter day, or , and con rm with .
Preset value MONTH is ashing.
4. Enter month, or , and con rm with .
Preset value YEAR is ashing.
5. Enter year, or , and con rm with .
Preset TIME is ashing.
6. Enter hour, or , and con rm with .
Preset value MINUTE is ashing.
7. Enter minute, or , and con rm with .
The date and time are saved.
The programmer goes to RUN mode.
Domestic hot water systems 1)
– “fully pumped system”or “gravity-fed system
The time on the programmer must be correct. Some types have to be
adjusted in spring and autumn at the changes between Greenwich
Mean Time and British Summer Time.
You may be able to temporarily adjust the heating programme, for
example, ‘Override’, ‘Advance’, or ‘Boost’. These are explained in the
manufacturer’s instructions.
The heating will not work if the room thermostat has switched the
heating off. And, if you have a hot-water cylinder, the water heating
will not work if the cylinder thermostat detects that the hot water has
reached the correct temperature.
Description of the device
Your two channel programmer provides timing control for your central
heating and domestic hot water, letting you set ON and OFF periods to
suit your own lifestyle.
• Backlit LCD Display
• Real Time Clock
• Up to 3 ON/OFF per day
• Automatic summertime / wintertime changeover
• Daily, weekly 1) and week-weekend 1) programming possibility
• Different running modes: OFF, AUTO, ONCE, CONTINUOUS and
HOLIDAYS 1)
• Manual override function
• Manual extra hour function
• 3 different pre-programmed pro les, customizable by user
• Boiler service interval indication & actions 1)
Designated use
• The programmer is used to control central heating zone systems or
combi boilers and domestic hot water systems (“fully pumped” or
“gravity-fed”).
• Suitable for use in dry rooms only!
• Do not install in the vicinity of devices which generate inductive
discharges (motors, transformers, etc.)
Technical data
Dimensions H x W x D (mm) 95 x 148 x 36
Weight g (approx.) 285
Power supply 230 V AC / 50-60 Hz
Power consumption < 3 W
Power reserve > 2h
Switching capacity 3 A 250 V ~ resistive, cos φ= 1
3 A 250 V ~ inductive, cos φ= 0.6
Time display 24 h or 12 h AM/PM format
Time setting resolution
– Time of day
– Programmes / min. switching
1 min.
1 min.
Programmes Selectable (daily , weekly, or
week-weekend)
Number of switchings per day 3 ON/OFF pairs
(2 ON/OFF pairs selectable)
Operating temperature range 0°C ... + 45°C
Ambient temperature -20°C ... + 55°C
Humidity range 10 to 90% RH, non condensing
Accuracy Type ± 1 sec./day at +20°C
Terminal capacity 2 x 2,5 mm2
Protection type IP 30
European standards EN60730-2-7
Compliant with building regulations
(Part L UK) (Part J Scotland)
Running a built-in programme (default programmes)
With the date and time correct, your timer will now be operating to the
built-in programmes. These have been designed to provide heating at
typical times throughout the day.
The built-in programmes give you a starting point that you can
personalise to your own requirements, please see the section “Review/
Edit central heating program” or “Review/Edit domestic hot water
program”.
Built-in programme STD (DEFAULT)
Daily ON1: 06:30 am ON2: 12:00 pm* ON3: 04:30 pm
OFF1: 08:30 am OFF2: 12:00 pm* OFF3: 10:30 pm
Weekly 1) ON1: 06:30 am ON2: 12:00 pm ON3: 04:30 pm
OFF1: 08:30 am OFF2: 01:00 pm OFF3: 10:30 pm
Week- ON1: 06:30 am ON2: 12:00 pm ON3: 04:30 pm Mo - Fr
Weekend 1) OFF1: 08:30 am OFF2: 01:00 pm OFF3: 10:30 pm
ON1: 06:30 am ON2: 12:00 pm ON3: 04:00 pm Sa - Su
OFF1: 09:30 am OFF2: 01:00 pm OFF3: 10:30 pm
Built-in programme HOME
Daily ON1: 06:30 am ON2: 12:00 pm* ON3: 04:00 pm
OFF1: 09:30 am OFF2: 12:00 pm* OFF3: 11:00 pm
Weekly 1) ON1: 06:30 am ON2: 12:00 pm ON3: 04:00 pm
OFF1: 09:30 am OFF2: 01:00 pm OFF3: 11:00 pm
Week- ON1: 06:30 am ON2: 12:00 pm ON3: 04:30 pm Mo - Fr
Weekend 1) OFF1: 09:30 am OFF2: 01:00 pm OFF3: 11:00 pm
ON1: 06:30 am ON2: 12:00 pm ON3: 04:00 pm Sa - Su
OFF1: 09:30 am OFF2: 01:00 pm OFF3: 11:00 pm
Built-in programme ECO
Daily ON1: 06:30 am ON2: 12:00 pm* ON3: 05:30 pm
OFF1: 07:30 am OFF2: 12:00 pm* OFF3: 10:00 pm
Weekly 1) ON1: 08:30 am ON2: 12:00 pm ON3: 05:30 pm
OFF1: 09:30 am OFF2: 01:00 pm OFF3: 10:00 pm
Week- ON1: 06:30 am ON2: 12:00 pm ON3: 05:30 pm Mo - Fr
Weekend 1) OFF1: 07:30 am OFF2: 12:00 pm OFF3: 10:00 pm
ON1: 08:30 am ON2: 12:00 pm ON3: 05:30 pm Sa - Su
OFF1: 09:30 am OFF2: 01:00 pm OFF3: 10:30 pm
* On/off prgrammes with the same time cancel out - no switching will occur.
The built-in programmes can be selected in the INSTALLERS MENU.
To access to installers menu, the device must be working in RUN mode.
INST MENU
DIGI CLOCK
BACKLIGHT
S W CHANGE
PROG TYPE
10 sec.
1. Make sure the device is working in RUN mode.
2. Press and hold buttons at the same time for 10 seconds.
INST MENU opens and OK is ashing.
3. Con rm with .
Installers menu is activated.
4. Press 3 x until PROG TYPE is displayed.
5. Press to edit settings.
Preset value is ashing.
6. Press or to scroll through the menu. Choose your desired
setting (DAILY, WEEKLY 1), 5-2 DAYS 1)) and con rm with .
The chosen setting is saved.
The next menu item NR PERIODS is displayed.
NR PERIODS
DEFAULT PROG
PUMP GRAVITY
7. Press to go to DEFAULT PROG.
8. Press to edit settings.
Preset value is ashing.
9. Press or to scroll through the menu. Choose your desired
setting (STD, HOME or ECO) and con rm with .
The chosen setting is saved
The next menu item PUMP GRAVITY is displayed.
10. Press the SELECT