(3) The unit adopts environment-friendly, colorless, odorless and flammable R32
refrigerant.
(4) The room area for installation, operation and storage of combustible
refrigerant unit shall be larger than the specified space area.
(5) Do not puncture or ignite the unit.
(6) The relevant gas regulations of the country or region where the installation is
carried out shall be observed.
(7) Avoid installing the unit in a narrow room to prevent the concentration of
refrigerant in the room from exceeding the limit value in case of refrigerant
leakage, resulting in hypoxia or suffocation.
(8) Unless specially recommended by the manufacturer, do not use any method
to accelerate the defrosting process or clean the frosted part.
(9) The unit shall be stored to prevent mechanical damage caused by accidents.
(10) The unit shall be stored in a room without continuous fire source (such as
open fire, ignited gas appliance, and open electric heater).
(11) Before maintenance or repair of heat pump unit using combustible refrigerant,
safety inspection must be carried out to ensure that the risk of fire is
minimized.
(12) When installation:
1) Be sure to use special accessories and parts;
2) It is forbidden to violate the nitrogen filling welding process;
3) It is forbidden to short circuit or cancel the pressure switch;
4) The unit controlled by the wire controller must be connected to the wire
controller before being powered on.
(13) Before installation, please check the safety of the power supply used and
whether it is consistent with the power supply required on the nameplate. After
the power cord is connected, be sure to install the electrical box cover.
(14) The heat pump unit shall use a special power cord with proper power capacity,
and the wiring sectional area shall not be less than the specification
requirements of the power cord in the Manual.
(15) The unit shall use special circuit and socket, and be equipped with appropriate
leakage protection switch and circuit breaker (air switch). The circuit breaker
shall be full-pole open, with the contact breaking distance of at least 3 mm.
(16) According to the relevant laws, regulations and electrical standards, special