Instructions
STEP 1. TESTING THE
TRANSMITTER AND
RECEIVER WITH BATTERIES
STEP 2. INSTALLING THE
TRANSMITTER TO THE DOOR
Skip to STEP 5. unless you wish
to change the factory set tune
and volume or house codes.
WIREFREE BELL PUSH
STEP 3. TUNE SELECTION
& VOLUME CONTROL
Diagram 2.
STEP 5. TESTING
Diagram 1.
Transmitter
STEP 4. CHANGING THE
HOUSE CODE
The range of the unit is up to 100
metres but mounting the
transmitter on metal or UPVC
doorframes may make the unit
inoperative or seriously reduce the
operating range.
As with all low powered transmitters
the number of wall and ceilings the
signal has to travel though between
the transmitter and receiver also
affects the range.
Once a suitable surface is found
remove the transmitter base
following 1).
Use these as templates to fix the
base on to a doorframe. Ensure the
transmitter is the right way up so
that the slot is at the bottom.
If mounting on to masonry, wall
fixings will be required. Refit unit to
base.
IMPORTANT: The screws must be
fixed flush or the battery will not
maintain contact with the terminals
and the unit will not operate.
The unit comes with a factory
pre-set tune but it can be changed.
The tune is determined by the slider
switch as in Diagram 2.
Remove transmitter in 1) above
leaving the battery in and select
tune as shown in Diagram 2.
Press the push button to hear the
sound each different setting
produces.
Once a desired tune is selected,
carefully replace transmitter. Up to
3 different sound options are
available.
The unit comes with factory set
code. Only change it if you
experience interference from a
neighbour’s unit.
Remove cover transmitter from base
as in 1) leaving the batteries in
position. Set dial as in Diagram 2.
to required number i.e “6”, set this
number “6” on the corresponding
dial on the receiver. Please note if
the sequence is not identical in both
the transmitter and receiver then
the unit will not operate. Press the
button on the transmitter to check
that the chime works and carefully
replace covers as above.
Test your doorchime by moving the
receiver in different rooms at
varying distances from the
transmitter to ascertain the
coverage available in your home,
this way you are unlikely to miss
any visitors.
MODEL NUMBER:
DW060A: Wirefree Transmitter only
• No more wires
• Battery included for Transmitter
(2 x AAA)
• Transmitter fixing screws included
Please read the instructions fully
before attempting installation.
--
1) Transmitter
The battery compartment slot is
located on the bottom of the unit.
Using a flat screwdriver insert into
slot and gently push to remove the
lower cover.
Insert the two AAA batteries
supplied and refit the base cover.
Before drilling any holes position
the transmitter on the door or door
frame outside (ideally a flat wooden
area) and press the button to ensure
the signals are getting through to
the receiver. Please test with the
door closed to simulate actual
working conditions.
You should also look to position the
transmitter in an unexposed place to
protect from rain.
6. TROUBLE SHOOTING
7. CONNECTING TO AN
EXISTING SYSTEM
GUARANTEE
REMARKS
Issue number 701324
West Road,
Harlow,
Essex
CM20 2BG
Tel: 01279 772 772
Fax: 01279 635 285
Email: [email protected]
Web: www.greenbrook.co.uk
Fault : Chime does not sound
Cause :
• Check batteries are not exhausted
and they have been inserted the
correct way round. Do not mix
different types of batteries.
• Re-check the dials and switches in
the transmitter and receiver if the
house codes have been changed.
• Move the receiver nearer the
transmitter.
Using additional wirefree
transmitters or receivers.
To identify visitors at a second door,
a DW060A transmitter can be
purchased separately and fixed to
the outside door. Follow instructions
in section 2 above.
A different tune on the second
transmitter can be selected to
identify which door the caller is at.
Follow section 3 above. Ensure the
house codes on all the transmitters
and receivers are exactly the same
(see section 4 above).
Additional receivers are also
available – models DW041A and
DW051A, so that doorchime can be
heard in a different part of the
house simultaneously. e.g. in the
garden shed and in the kitchen.
Your door chime is guaranteed for
12 months from date of purchase.
Please retain till receipt as proof of
purchase. This is in addition to your
statutory rights.
For indoor use only.
No naked flame sources, such as
lighted candles should be placed
near the unit.
The unit should not be exposed to
dripping or splashing and no objects
filled with liquids, such as being
placed near vases.
Please dispose of old, defective
batteries in an environmentally
friendly manner in accordance with
the relevant legislation.
This symbol indicates separate
collection of electronic/electrical
equipment.
PLEASE KEEP THESE
INSTRUCTIONS SAFE
FOR FUTURE REFERENCE
If after going through the trouble
shooting section, you still experience
difficulty please ring us on
GreenBrook‘s Help Line
01279 772 750
during office hours quoting
the model number

Other Green Brook Transmitter manuals

Green Brook KingShield DW070AN-C Installation and user guide

Green Brook

Green Brook KingShield DW070AN-C Installation and user guide

Green Brook DW070A User manual

Green Brook

Green Brook DW070A User manual

Popular Transmitter manuals by other brands

Vega VEGABAR 87 Quick setup guide

Vega

Vega VEGABAR 87 Quick setup guide

Caliber PMT 567BT quick start guide

Caliber

Caliber PMT 567BT quick start guide

Emerson Rosemount 326P quick start guide

Emerson

Emerson Rosemount 326P quick start guide

Daniels VT-3H040 instruction manual

Daniels

Daniels VT-3H040 instruction manual

RMG ENCO08 operating instructions

RMG

RMG ENCO08 operating instructions

JUMO dTRANS T02 PCP operating instructions

JUMO

JUMO dTRANS T02 PCP operating instructions

Vega VEGABAR 83 operating instructions

Vega

Vega VEGABAR 83 operating instructions

RKI Instruments 65-2336RK Operator's manual

RKI Instruments

RKI Instruments 65-2336RK Operator's manual

Emerson Rosemount 2051 Reference manual

Emerson

Emerson Rosemount 2051 Reference manual

INOR IPAQ C330 Series manual

INOR

INOR IPAQ C330 Series manual

Microcyber NCS-PT105II Operation manual

Microcyber

Microcyber NCS-PT105II Operation manual

Linear D-22D Code Setting Instructions

Linear

Linear D-22D Code Setting Instructions

Rotronic HygroFlex HF8 user guide

Rotronic

Rotronic HygroFlex HF8 user guide

HaiKe DAB-005B user manual

HaiKe

HaiKe DAB-005B user manual

evertz 2407RGBT/DVIT instruction manual

evertz

evertz 2407RGBT/DVIT instruction manual

Planex BT-WTM01 manual

Planex

Planex BT-WTM01 manual

Furness controls FCO432 user guide

Furness controls

Furness controls FCO432 user guide

Avantree BTTC-418 user manual

Avantree

Avantree BTTC-418 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.