GreenTech pureAir 750 Plus User manual

Owner’s Manual
Active Air Purification with ARC®Technology

2
About pureAir 750+ Wall Mount
This unit is designed to be permanently mounted to a wall to help reduce
odors and create a fresh, clean environment. pureAir 750+ Wall Mount
is perfect for providing air purification in large rooms, small offices, or
similar spaces without ductwork, up to 750 sq. ft.
pureAir 750+ Wall Mount utilizes Active Radiant Catalysis (ARC®)
technology that generates advanced oxidation products (AOPs), primarily
consisting of hydro-peroxides, or safe, vaporized hydrogen peroxide. The
Active Radiant Catalysis purification process uses ultraviolet energy to
activate a multi-metal catalyst, which converts water vapor into oxidizers
including peroxide and hydroxyls. In addition to the ARC process, Bipolar
Ionization and the unique ODOGard® treated filter are used to assist in
neutralizing pollutants and odors.
Table of Contents
Specifications ...........................................................3
Warnings................................................................3
Unit Diagrams...........................................................4
Installation ..............................................................5
Cleaning the Unit........................................................6
Filter Replacement ......................................................6
ARC Cell Replacement ..................................................7
BPI Module Replacement................................................8
Replacement Part Numbers.............................................9
Cell Disposal ............................................................9
Troubleshooting........................................................ 10
Warranty Information ...................................................11
Read all instructions carefully in user manual before operating air purifier.

3
Specifications
Models ................................. pureAir 750+ Wall Mount - 1X5789
. . . . . . . . . . . . . . . . . . . . . . . . . pureAir 750+ Wall Mount NO3 (No Ozone) - 1X5821
Dimensions ..............11.92” H (303mm) x 9.72” W (247mm) x 3.64” D (93mm)
Weight ........................................................3.3 lb (1.5kg)
Supply ..................................................120/240VAC / 17W
Operation ................................................... 24VDC / .67A
Effective Area* ...............................................Up to 750 ft2
Warranty ..........................................................2 Years
*Depending on variables such as the severity and frequency of pollution, flow of air in the
environment, humidity, and temperature.
Warnings
Please read and follow all warnings and cautions before installing and
using your unit.
Use this unit only in a manner intended by the manufacturer.
If you have questions, contact the manufacturer.
Never insert hands into the unit’s fan motor
while it is plugged in or running.
Avoid looking directly at the UV lamps in the
ARC® (Active Radiant Catalysis) Cell.
Follow all installation instructions.
Before servicing or cleaning the unit, unplug from its power source.
Replace filter every 3-4 months to avoid damaging your unit.

4
Unit Diagrams
Unit Front
Unit Rear
Unit Cover
Air Outlet
DC Power Jack
DC Power Plug
Unit Bottom Unit Internals
Air Intake
ODOGard®
MERV Filter
ARC Cell
Power Compartment
Bipolar Ionization
Module
Mounting Bracket

5
Installation
STEP 1
STEP 2
STEP 3
1. Determine location for desired
placement of unit close enough
to a power outlet to allow the
included 120/240 VAC to 24 VDC
power adapter to be plugged
in. Typically, the angled grille
should be pointed upward and
mounted as high on the wall as
practical, within 18 inches of the
ceiling if possible.
2. Plug the power adapter’s elbow
style DC connector into the unit’s
rear power outlet.
3. Attach pureAir 750+ Wall Mount
to the wall location with included
screws utilizing the mounting
bracket flanges.
4. Make proper electrical connection
of 24VDC power adapter to outlet.

6
Cleaning the Unit
ODOGard® Filter Replacement
1. Disconnect unit from power source.
2. Remove the Cover’s two screws along the top
edge with a #1 Phillips-Head screw driver.
3. Tilt the Cover away from the top of the unit.
4. Wipe everything down with a damp cloth.
5. Close and secure the Cover of the unit.
6. Reconnect unit to power source.
1. Disconnect unit from power source.
2. Remove the Cover’s two screws along the top edge
with a #1 Phillips-Head screw driver.
3. Tilt the Cover away from the top of the unit.
4. Replace the used Filter at the bottom
with the red side out.
5. Close and secure the Cover of the unit.
6. Reconnect unit to power source.
WARNING: Make sure to disconnect the unit from its power source before
any maintenance or cleaning is done.
WARNING: Make sure to disconnect the unit from its power source
before any maintenance or cleaning is done.
NOTE: We recommend replacing the Filter every 3-4 months or when noticeably contaminated.
See Page 9 for Replacement Part Numbers.
The unit will need to be cleaned inside from time to time. Be sure to use extreme
caution when doing this in order to avoid any damage to the unit or harm to yourself.

7
ARC® Cell Replacement
1. Disconnect unit from power source.
2. Remove the Cover’s two screws along the
top edge with a #1 Phillips-Head screw
driver.
3. Tilt the Cover away from the top of the unit.
4. Remove the Black Grille by sliding it out.
5. Locate the ARC Cell and gently lift it up out
of the case.
6. Disconnect the power cable to your old
ARC Cell and replace it with your new
ARC Cell. Ensure plug is fully seated in the
connection and the wire is fully seated into
the grommet/bulkhead.
7. Place the ARC Cell in place in the unit with
the warning label visible, making sure air
can flow through the cell.
8. Replace the Black Grille.
9. Close and secure the Cover of the unit.
10. Reconnect unit to power source.
WARNING: Make sure to disconnect the unit from its power source
before any maintenance or cleaning is done.
WARNING: Please do not throw a used ARC®Cell in the garbage. See
CELL DISPOSAL (PG. 9) for disposal instructions
Your ARC Cell should be replaced every year.
See Page 9 for Replacement Part Numbers.
STEP
2-3, 9
STEP 6
STEP 5&7

8
BPI Module Replacement
WARNING: Make sure to disconnect the unit from its power source
before any maintenance or cleaning is done.
Your BPI Module should be replaced every year.
See Page 9 for Replacement Part Numbers.
1. Disconnect unit from power source.
2. Remove the Cover’s two screws along the top
edge with a #1 Phillips-Head screw driver.
3. Tilt the Cover away from the top of the unit.
4. Remove the Black Grille by sliding it out.
5. Disconnect BPI Module’s black and white wires
from lever connectors (orange/clear).
6. Remove screws securing the BPI Module to
the unit and remove Module.
7. Install new BPI Module, securing it to the unit
with screws.
8. Cut black and white wires to length that
will reach the lever connectors, leaving
sufficient length to strip back insulation
from end of wires ½”.
9. Connect black and white wires from BPI Module to the lever connectors.
Make sure the connections are black to black and white to white.
10. Replace the Black Grille.
11. Close and secure the Cover of the Unit.
12. Reconnect unit to power source.

9
Cell Disposal (Hg - LAMP CONTAINS MERCURY)
Please do not throw a used ARC®Cell in the garbage. The special UVC
bulb used in the unit contains a very small amount of mercury. Manage in
accordance with disposal laws.
(Visit www.lamprecycle.org for proper instructions.)
Dispose of the spent ARC Cell and UV Lamp at your local recycling center or
by local regulations.
Replacements Part Numbers
Please reference these part name and numbers when contacting your
dealer or Greentech for replacement parts.
pureAir 750+ Wall Mount Replacement ARC®Cell ................................1X3200
pureAir 750+ Wall Mount (No Ozone) Replacement ARC®Cell.....................1X5115
pureAir 750+ Wall Mount Replacement ODOGard® Filter (Both Models) - 6 Pack ...1X5838
pureAir 750+ Wall Mount Replacement BPI Module (Both Models) ..................1X5787

10
Troubleshooting
ARC® Cell Doesn’t Turn On
• Check for secure electrical connections
• Check the Line Fuse
• Fan needs replaced (Contact your dealer or visit our website,
greentechenv.com, to contact us directly.)
• Check for secure electrical connections
• Check the Line Fuse
• Try another ARC®Cell
• Ballast needs replaced (Contact your dealer or visit our website,
greentechenv.com, to contact us directly.)
Fan Doesn’t Turn On

11
Warranty Information
Your PureAir 750+ Wall Mount (Product) and genuine Greentech parts are warranted
to be free from all defects in material and workmanship in normal use for a period
of two (2) years from date of purchase.
The warranty is granted only to the original purchaser. The warranty is subject to the
following provisions:
Any damages or malfunctions caused by negligence, abuse, or use not in
accordance with the Product Owner’s Manual are not covered by this warranty.
Likewise, any defects or damages caused by unauthorized service or the use of other
than Genuine Greentech Parts are not covered.
Greentech will, at its option, repair or replace a defective Product or part(s) for
the Product that is/are covered by this warranty. As a matter of warranty policy,
Greentech will not refund the customer’s purchase price.
OBTAINING WARRANTY SERVICE
To obtain warranty service you must return the defective product along with proof of
purchase to the Greentech Authorized Service Center. All shipping costs submitted
under this Warranty shall be borne by purchaser. Unless this Warranty is expressly
renewed or extended by Greentech, any repaired or replaced part of unit shall be
warranted to the original purchaser only for the length of the unexpired portion of
the original warranty. For the location of the nearest Greentech Authorized Service
Center or for other service information, please visit us online at:
greentechenv.com
Before any product is sent for service, the customer should contact the
Greentech Service Center to obtain a Return Merchandise Authorization (RMA)
Number. This RMA Number should be clearly written on the box before shipping.
All components/parts including the remote (if applicable), manuals, and
original packaging should be included in the return if available.
FURTHER LIMITATIONS AND EXCLUSIONS ARE AS FOLLOWS
Any warranty that may be implied in connection with your purchase or use of the
Product, including any warranty of merchantability or any warranty for Fitness For
A Particular Purpose is limited to the duration of this warranty. Some states do not
allow limitations on how long an implied warranty lasts, so the above limitations
may not apply to you.
Your relief for the breach of this warranty is limited to the relief expressly provided
above. In no event shall Greentech be liable for any consequential or incidental
damages loss of profit, or medical expenses caused by any misuse, abuse,
accident, negligence, or failure to follow instructions. The company will not be
responsible for any written or oral statements made that are inconsistent with
this written warranty, or which are misleading or inconsistent with the facts as
published by the company in the literature or specifications. Some states do not
allow the exclusion or limitation of incidental or consequential damages, so the
above limitation or exclusion may not apply to you. This Warranty gives you specific
legal rights, and you may also have other rights which vary from state to state.

OM REVISION: Greentech-pureAir-750-Plus-WallMount-Owners-Manual-211214
greentechenv.com
Table of contents