General Information
External venetian blinds provide solar shading. They should not be considered security equipment. They can be automatically
or manually tilted at any height adjustment.
The end user must read and observe these Operating and Maintenance Instructions before using the blinds for the first time.
General information about the QR code (URL with serial number)
• To each product is assigned a unique serial number to ensure whose traceability.
• The label with the QR code must not be removed under any circumstances.
General Hazard and Safety Information
• Property damage and bodily injury may result from improper handling or disregarding safety information.
• In the event of damages resulting from non-observance of these instructions or of the accompanying documentation, all
warranty claims become null and void.
• Griesser AG accepts no liability for consequential losses or damages.
Safety Information for Operation and Use
Risk of injury or damage to the product from improper operation
• Attach operating controls within view of the curtain, in accordance with national regulations.
• Keep operating controls out of the reach of children.
• May only be operated by trained persons.
• Do not touch moving parts when deploying or retracting blinds. Risk of crushing obstacles in the deployment area.
• Do not allow jewelry, clothing, hair or body parts to become entangled in the product.
• To prevent damage to the external venetian blinds from objects in the way when the blinds are being lowered, the
vertical transport mechanism in the Grinotex III disengages if the blind makes unexpected contact with an object. If the
objects/obstructions are higher than 2.25 m, damage to the Grinotex III is to be expected, and the may not be raised
automatically.
• Stand clear until the end position has been reached.
• Do not touch any interior parts that are exposed due to damage (e.g. cables / cords, control elements).
• Before moving the unit, please check that there is no obstacle in the travel path.
Damage to the product from icing
• In winter, check products for icing before operating. In the event of icing, do not operate.
• Discontinue automatic operation in winter, even if icing has not been predicted.
Risk of injury due to inadequate maintenance
• Check products regularly for signs of wear.
• Do not use products that require repairs.
• Malfunctions may only be rectified by trained and qualified personnel.
Use only original Griesser replacement parts
• No assurance is provided that the product will function with accessories, parts or operating equipment made by other
manufacturers. Modifications to the product that are not expressly approved by Griesser render warranty claims null
and void.
Risk of injury or damage to the product from unintentional operation
• Disconnect products from the power supply power when maintenance work is taking place.
• Observe safety distances.
Risk of damage to the product from improper operation
• When operating manually, do not use force to deploy/retract blinds.
• Do not operate products beyond their mechanical limits.
• Retract curtains before permitted wind load is exceeded.
Risk of injury and damage to the product from interruptions to the power supply (e.g. power outages)
Ensure that situations dangerous to people and the product do not arise

3Griesser | Operating Instructions | Grinotex®III
Electrical Installations
Electrical connections may only be carried out by certified electricians
• Additional national regulations regarding the maintenance and repair of electrical systems shall be observed. These
may result in an increase in the maintenance intervals.
Operation
Motorized operation
Blinds are operated using central or local wall-mounted or hand-held controls with an Up /Down/Stop button. The operating
functions of the controls are described in the operating instructions for the controls.
Manual operation
Blinds are operated using an articulated crank.
Use
• The external venetian blinds meet the requirements of the wind classes indicated in the declaration of conformity and may
remain extended only up to the specified wind class.
• External venetian blinds provide solar shading and may not be used as security equipment.
• When operating the awning manually, stand directly in front of the crank assembly to operate the blind.
• When operating an external blind, ensure that no obstacles (flower pots, toys, chairs, etc.) are located in the blind’s path.
• Never lower the blind with the window open (European standards and guidelines).
• When operating the blind manually, do not use force if the blind jams. Change the direction of rotation in order to check if
the blind has reached the end of the track.
Maintenance / Inspection
Any repairs must be carried out by a qualified technician.
Interval Location Task
Monthly Avoid damage to positioning mechanism
due to harmful environmental influences
• Move product through complete range, from top to
bottom, at least once
Several times a year
Guides and slats
• Check guides
• Clean (depending on contamination level caused by
surrounding area and environmental impact)
• Remove any foreign objects (e.g., leaf debris)
Cable tension • Check cable tension
• Retension or replace cable tensioner if necessary
Additives that can be used for maintenance
Alkaline, acidic or abrasive lubricants must not be used.
Resources Location Task
Rinse with clear water Entire Product except motor Cleaning the slats and guides
Grease-free lubri-
cants
Guide Lubricating the slider and the guide rails
Silicone grease
Dry lubricants
PTFE-based aerosol

4Griesser | Operating Instructions | Grinotex®III
Cleaning
The air contains minuscule solid particles, such as dust, rust, and aggressive substances including salt and kerosene, which
encourage corrosion and have a negative impact on how the blinds function. External venetian blinds are equipped with
various mechanical parts that must therefore be serviced regularly to ensure long-term use.
Use a soft cloth or non-abrasive sponge to apply lukewarm water with a highly diluted, mild cleaning agent to the slats.
Carefully scrub away dirt. It is imperative that you then rinse the slats well with clear water.
Cleaning agents with alkaline, acidic or abrasive active ingredients and pressurized steam cleaning may not be used!
Interval Environmental conditions
Monthly
• Outdoor areas with exceptionally harsh conditions
• Coastal and offshore areas with high salt exposure
• Near the coast 0–3 km
Quarerly
• Outdoor area with very harsh conditions
• Industrial atmosphere with high relative humidity and
aggressive atmosphere
• Near the coast 3–10 km
Half-yearly
• Industrial atmosphere and coastal atmosphere with
moderate salt contamination
• Near the coast > 10 km
How to clean
Step Task
Moisten with water
Use a sponge or non-abrasive cloth
Use a suitable cleaning product
Rinse thoroughly with clear water
Avoid extreme temperatures for cleaning.
Maintenance and cleaning are essential to ensure the product’s longevity over time.

5
<,m/s ,m/s ,m/s , m/s ,m/s , m/s ,m/s , m/s ,m/s
<,km/h ,km/h ,km/h km/h km/h km/h km/h km/h km/h
Griesser | Operating Instructions | Grinotex®III
Setting values for sensors according to SIA 342
Sensors fitted next to product.
Class Class Class Class Class Class Class Class [] Class []
[] No wind resistance class in accordance with DIN EN 13659 and SIA 342.
Wind classes of Griesser external venetian blinds
Product Permissible wind resistance class limit values1
Width (mm)
Grinotex®III --
Grinotex®III Sinus - -
1Tests in accordance with product standard EN 13659. Product limit dimensions in accordance with data sheet.
The values in the table apply with the following reservations:
• Product dimensions and use comply with the Griesser technical data sheet.
• Installation, fastening and operation are carried out in accordance with installation and operating instructions.
• The products should be installed in the soffit / directly on the facade, with the curtain < 100 mm away from the facade.
• If the distance from the facade is between 100 and 300 mm, the value in the table must be reduced by 1 class.
• If the distance from the facade is between 300 and 500 mm, the value in the table must be reduced by 2 classes.
Furthermore, the table cannot be applied.
Application note
The external venetian blinds cannot be protected with wind sensors against sudden gusts of wind. Make sure that the external vene-
tian blinds remain retracted if a storm is imminent. Updrafts or fallwinds at facades could lead to the destruction of the external vene-
tian blinds. Wind sensors cannot detect these as a rule.

griessergroup.com
Inspired by the Sun.
20221124 Subject to change without prior notice
Table of contents
Other Griesser Window Blind manuals

Griesser
Griesser Soloroll II Manual

Griesser
Griesser Alucolor 25 User manual

Griesser
Griesser Metalunic V User manual

Griesser
Griesser Solomatic II User manual

Griesser
Griesser Aluflex User manual

Griesser
Griesser FSR1 User manual

Griesser
Griesser G 2000 User manual

Griesser
Griesser Lamisol III User manual