manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Grohe
  6. •
  7. Plumbing Product
  8. •
  9. Grohe Eurostyle 32 992 User manual

Grohe Eurostyle 32 992 User manual

D.....1 I.....5 N.....9 GR .....13 TR .....17 BG .....21 RO .....25
GB .....2 NL .....6 FIN .....10 CZ .....14 SK .....18 EST .....22 CN .....26
F.....3 S.....7 PL .....11 H.....15 SLO .....19 LV .....23 RUS .....27
E.....4 DK .....8 UAE .....12 P.....16 HR .....20 LT .....24
Design + Engineering GROHE Germany
Eurostyle
Eurostyle
94.949.131 ÄM 212784/01.13
32 992
32 993 32 994
D.....1 I.....5 N.....9 GR .....13 TR .....17 BG .....21 RO .....25
GB .....2 NL .....6 FIN .....10 CZ .....14 SK .....18 EST .....22 RUS .....26
F.....3 S.....7 PL .....11 H.....15 SLO .....19 LV .....23
E.....4 DK .....8 UAE .....12 P.....16 HR .....20 LT .....24
I
Bitte diese Anleitung an den Benutzer der Armatur weitergeben!
32 994
32 992 32 993
Please pass these instructions on to the end user of the fitting!
II
3
1
36-42
22mm
30mm
2
B
A
2,5mm
4
C
C
5
M
N
O
P
R
S
V
U
8
T
7mm
13mm
12mm
G
H
K
E
D
L
3mm
7
6
2,5mm
1
D
Anwendungsbereich
Betrieb ist möglich mit: Druckspeichern, thermisch und hydraulisch
gesteuerten Durchlauferhitzern. Der Betrieb mit drucklosen
Speichern (offenen Warmwasserbereitern) ist nicht möglich!
Technische Daten
•Fließdruck
- min. 0,5 bar
- empfohlen 1 - 5 bar
•Betriebsdruck max. 10 bar
•Prüfdruck 16 bar
Zur Einhaltung der Geräuschwerte nach DIN 4109 ist bei Ruhe-
drücken über 5 bar ein Druckminderer einzubauen.
Höhere Druckdifferenzen zwischen Kalt- und Warmwasser-
anschluss sind zu vermeiden!
•Durchfluss bei 3 bar Fließdruck:
32 992 / 32 993 ca. 20 l/min
32 994 ca. 17 l/min
•Temperatur
Warmwassereingang: max. 80 °C
Empfohlen: (Energieeinsparung) 60 °C
Verbrühschutz möglich durch Einbau eines Temperatur-
begrenzers (siehe Ersatzteile Klappseite I, Best.-Nr.: 46 375)
•Wasseranschluss kalt - unten
warm - oben
Hinweis:
Diese Grohe AP-Wandbatterien DN 15 sind mit DIN-DVGW bauart-
geprüften Rückflussverhinderern ausgerüstet.
Installation
Rohrleitungssystem vor und nach der Installation gründlich
spülen (DIN 1988/DIN EN 806 beachten)!
Anschlüsse montieren und Batterie anschrauben, siehe
Klappseite II, Abb. [1].
Maßzeichnungen auf Klappseite I beachten.
Der Kaltwasseranschluss muss unten, der Warmwasseranschluss
oben erfolgen.
Die Ausladung kann mit einer Verlängerung um 20mm vergrößert
werden (siehe Ersatzteile, Klappseite I, Best.-Nr.: 07 130).
Verstellung des Auslaufes der Batterien 32 992 und 32 993
Es sind 5 verschiedene Stellungen möglich.
Auslaufwinkel verändern:
1. Gewindestift (A) mit Innensechskantschlüssel 2,5mm heraus-
schrauben, siehe Abb. [2].
2. Auslauf (B) in die gewünschte Position drehen, siehe hierzu
Maßzeichnungen auf Klappseite I.
3. Auslauf (B) mit Gewindestift (A) wieder befestigen.
Kalt- und Warmwasserzufuhr öffnen und Anschlüsse auf
Dichtheit prüfen.
Funktion der Armatur prüfen, siehe Abb. [3].
Durch Ziehen des Hebels wird die Wasserzufuhr freigegeben.
Das Wasser tritt erst am Wanneneinlauf aus.
Funktion der automatischen Umstellung (C), siehe
Abb. [4] und [5].
Umstellknopf ziehen = Umschalten von Wannen-
einlauf auf Brauseauslauf
Umstellknopf drücken = Umschalten von Brauseaus-
lauf auf Wanneneinlauf
Schließen der Armatur bewirkt automatisches Umschalten von
Brauseauslauf auf Wanneneinlauf.
Zusätzlich kann die Umstellung von Hand arretiert werden. (Vorteil-
haft bei Drücken unter 0,5 bar, bzw. bei geringer Entnahmemenge).
Ziehen Sie dazu den Umstellknopf der Umstellung (C) und drehen
diesen gegen den Uhrzeigersinn, siehe auch Abb. [5].
Mengenbegrenzer
Diese Armatur ist mit einer Mengenbegrenzung ausgestattet. Damit
ist eine stufenlose, individuelle Durchflussmengenbegrenzung
möglich.
Werkseitig ist der größtmögliche Durchfluss voreingestellt. In
Verbindung mit hydraulischen Durchlauferhitzern ist der Einsatz der
Durchflussmengenbegrenzung nicht zu empfehlen.
Zur Aktivierung siehe “Austausch der Kartusche” Punkt 1 bis 3,
Abb. [6] und [7].
Wartung
Alle Teile prüfen, reinigen, evtl. austauschen und mit
Spezialarmaturenfett einfetten.
Kalt- und Warmwasserzufuhr absperren!
I. Austausch der Kartusche, siehe Abb. [7].
1. Stopfen (D) aushebeln.
2. Gewindestift (E) mit Innensechskantschlüssel 3mm heraus-
schrauben und Hebel (G) abziehen.
3. Kappe (H) abziehen.
4. Schrauben (K) lösen und Kartusche (L) kpl. abnehmen.
5. Kartusche (L) kpl. austauschen.
Montage in umgekehrter Reihenfolge.
Einbaulage beachten!
Es ist darauf zu achten, dass die Dichtungen der Kartusche in die
Eindrehungen des Gehäuses eingreifen. Schrauben (K) ein-
schrauben und wechselweise gleichmäßig festziehen.
II. Rückflussverhinderer, siehe Abb. [8].
Rückflussverhinderer (M) herausnehmen.
III. Umstellung, siehe Abb. [8].
1. Abdeckkappe (N) abschrauben.
2. Mutter (O) mit Maulschlüssel 7mm abschrauben und
Umstellknopf (P) abnehmen.
3. Kopfstück (R) mit Maulschlüssel 13mm herausschrauben und
Feder (S) abnehmen.
4. Brauseanschlussnippel (T) mit Innensechskantschlüssel 12mm
herausschrauben.
5. Sicherungsscheibe (U) von der Umstellspindel (V) abziehen.
IV. Mousseurs (13 927) ausschrauben und säubern, siehe
Klappseite I.
Montage in umgekehrter Reihenfolge.
Ersatzteile, siehe Klappseite I ( * = Sonderzubehör).
Pflege
Die Hinweise zur Pflege dieser Armatur sind der beiliegenden
Pflegeanleitung zu entnehmen.
2
GB
Application
Can be used in conjunction with: Pressurised storage heaters,
thermally and hydraulically controlled instantaneous heaters.
Operation with low-pressure displacement water heaters is not
possible.
Specifications:
•Flow pressure
- min. 0.5 bar
- recommended 1 - 5 bar
•Operating pressure max. 10 bar
•Test pressure 16 bar
If static pressure is greater than 5 bar, fit pressure reducer.
Avoid major pressure differences between hot and cold water
supply.
•Flow rate at 3 bar flow pressure:
32 992 / 32 993 approx. 20 l/min
32 994 approx. 17 l/min
•Temperature
Hot water inlet: (maximum) 80 °C
Recommended: (energy saving) 60 °C
Scalding protection possible by fitting a temperature limiter (see
replacement parts fold-out page I, ref. No. 46 375).
•Water connection cold - low
Installation
Flush pipes thoroughly before and after installation
(observe EN 806).
Install unions and screw-mount the mixer, see fold-out page II
Fig. [1].
Refer to the dimensional drawing on fold-out page I.
The projection can be increased by 20mm with an extension, (see
replacement parts fold-out page I, ref. No. 07 130).
The cold water supply must be connected to the lower and the hot
water supply on the upper inlet.
Adjustment of spout on mixer 32 992 und 32 993
There are 5 settings possible.
Proceed as follows to change angle of spout:
1. Remove set screw (A) with 2.5mm socket spanner, see Fig. [2].
2. Turn spout (B) into the wished postion, therefore refer to the
dimensional drawings on fold-out page I.
3. Refit spout (B) with set screw (A).
Open cold and hot-water supply and check connections for
leakage!
Check fitting for correct operation, see Fig. [3].
Pulling the lever will release water delivery.
Water will emerge from the bath spout first.
Operation of automatic diverter (C), see Figs. [4] and [5].
Pull diverter button = to divert flow from bath spout to
shower outlet
Press diverter button = to divert flow from shower outlet
to bath spout
Flow is diverted automatically from shower outlet to bath spout
when the mixer is turned off.
In addition, the diverter assembly can be secured manually
(advantageous at pressures below 0,5 bar or at low rates of
discharge). In this case, pull the diverter knob of the diverter
assembly (C) and turn it anti-clockwise, see also fig. [5].
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an infinitely
individual variable reduction in the flow rate.
The highest possible flow rate is set by the factory before despatch.
The use of flow rate limiters in combination with hydraulic
instantaneous water heaters is not recommended.
For commissioning see “replacing the cartridge” point 1 to 3,
Fig. [6] and [7].
Maintenance
Inspect and clean all parts, replace as necessary and grease with
special grease.
Shut off cold and hot water supply!
I. Replacing the cartridge, see Fig. [7].
1. Lever out plug (D).
2. Remove set screw (E) using a 3mm socket spanner and pull off
lever (G).
3. Pull off cap (H).
4. Replace complete cartridge (L).
5. Remove screws (K) and detach complete
cartridge (L).
Assemble in reserve order.
Observe the correct installation position!
Make sure that the cartridge seals engage in the grooves on the
housing. Fit screws (K) and tighten evenly and alternately.
II. Non-return valve, see Fig. [8].
Remove non-return valve (M).
III. Diverter, see Fig. [8].
1. Unscrew and remove cap (N).
2. With an open-ended 7mm spanner, unscrew and remove
nut (O) and remove diverter knob (P).
3. With an open-ended 13mm spanner, remove head
nut (R) and remove spring (S).
4. With a 12mm allen key remove outlet nipple (T).
5. Pull off lock washer (U) from diverter spindle (V).
IV. Unscrew and clean aerator (13 927), see fold-out page I.
Assemble in reverse order.
Replacement parts, see fold-out page I ( * = special accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.

This manual suits for next models

2

Other Grohe Plumbing Product manuals

Grohe Sail Cube 23 437 User manual

Grohe

Grohe Sail Cube 23 437 User manual

Grohe Eurodisc 33 772 User manual

Grohe

Grohe Eurodisc 33 772 User manual

Grohe Taron 19 658 User manual

Grohe

Grohe Taron 19 658 User manual

Grohe Grohtherm 1000 34143 User manual

Grohe

Grohe Grohtherm 1000 34143 User manual

Grohe Grohtherm 2000 New User manual

Grohe

Grohe Grohtherm 2000 New User manual

Grohe F1 21 082 User manual

Grohe

Grohe F1 21 082 User manual

Grohe EUPHORIA SYSTEM 26 128 User manual

Grohe

Grohe EUPHORIA SYSTEM 26 128 User manual

Grohe Blue Minta Pure User manual

Grohe

Grohe Blue Minta Pure User manual

Grohe 33 961 User manual

Grohe

Grohe 33 961 User manual

Grohe Concetto 19575001 User manual

Grohe

Grohe Concetto 19575001 User manual

Grohe Blue Pure Eurosmart 30 384 User manual

Grohe

Grohe Blue Pure Eurosmart 30 384 User manual

Grohe Ectos 34 555 User manual

Grohe

Grohe Ectos 34 555 User manual

Grohe Tenso User manual

Grohe

Grohe Tenso User manual

Grohe 37 145 User manual

Grohe

Grohe 37 145 User manual

Grohe 34 211 User manual

Grohe

Grohe 34 211 User manual

Grohe MintaTouch Series User manual

Grohe

Grohe MintaTouch Series User manual

Grohe Tectron User manual

Grohe

Grohe Tectron User manual

Grohe 06341XX0 User manual

Grohe

Grohe 06341XX0 User manual

Grohe 34 125 User manual

Grohe

Grohe 34 125 User manual

Grohe GROHTHERM 3000 COSMOPOLITAN 34 276 User manual

Grohe

Grohe GROHTHERM 3000 COSMOPOLITAN 34 276 User manual

Grohe QuickFix Start 30530002 User manual

Grohe

Grohe QuickFix Start 30530002 User manual

Grohe Lineare 19 409 User manual

Grohe

Grohe Lineare 19 409 User manual

Grohe Euroeco Cosmopolitan E 36 274 User manual

Grohe

Grohe Euroeco Cosmopolitan E 36 274 User manual

Grohe Ondus 38 915 User manual

Grohe

Grohe Ondus 38 915 User manual

Popular Plumbing Product manuals by other brands

SFA sanidouche flat installation instructions

SFA

SFA sanidouche flat installation instructions

resideo Braukmann BA300 installation instructions

resideo

resideo Braukmann BA300 installation instructions

KWC K.26.VB.56.700.38 Features

KWC

KWC K.26.VB.56.700.38 Features

Viega 6168.5 Instructions for use

Viega

Viega 6168.5 Instructions for use

baliv WT-330 N manual

baliv

baliv WT-330 N manual

FORENO EzyFlo EZF2 installation instructions

FORENO

FORENO EzyFlo EZF2 installation instructions

Delabie TEMPOFLUX 1 761900 manual

Delabie

Delabie TEMPOFLUX 1 761900 manual

BubbleFlush Water Stop V1 user manual

BubbleFlush

BubbleFlush Water Stop V1 user manual

PolyJohn HandStand 2 user manual

PolyJohn

PolyJohn HandStand 2 user manual

Helvex FB-185-19 installation guide

Helvex

Helvex FB-185-19 installation guide

Hans Grohe Talis S 32841010 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Talis S 32841010 Instructions for use/assembly instructions

Kohler K-1517 installation guide

Kohler

Kohler K-1517 installation guide

F.lli Frattini 98011 installation instructions

F.lli Frattini

F.lli Frattini 98011 installation instructions

Spectrum Brands Pfister Auden LF-042-AD Quick installation guide

Spectrum Brands

Spectrum Brands Pfister Auden LF-042-AD Quick installation guide

Symmons Duro SLW3612PP Operation & maintenance manual

Symmons

Symmons Duro SLW3612PP Operation & maintenance manual

Hansa 4478 0211 Installation and maintenance guide

Hansa

Hansa 4478 0211 Installation and maintenance guide

Salus SS901ZB Installation & quick start guide

Salus

Salus SS901ZB Installation & quick start guide

Outsunny A20-237 instructions

Outsunny

Outsunny A20-237 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.