Guangzhou GTD Lighting Technology Co., Ltd. TUNGDOU TD-LMZ 3019 User manual

LED Moving Head
TD-LMZ 3019
User’s Manual
Guangzhou GTD Lighting Technology Co., Ltd.
Tel: +86-20-61808296
Fax: +86-20-61812282
http://www.gtd-lighting.com

TD-LMZ 3019 User Manual
2
© 2017 GTD all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to
change without notice. GTD logo and identifying product names and numbers herein are trademarks of GTD. Copyright
protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or
judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of
their respective companies and are hereby acknowledged. All non-GTD brands and product names are trademarks or
registered trademarks of their respective companies.
GTD and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical
damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any
information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent
assembly, installation, rigging, and operation of this product.
Guangzhou GTD Lighting Technology Co., Ltd. | 27 Fu Yuan Yi Road, Guangzhou 510805, P.R.China
+86-20-61808296| +86-20-61812282 fax | www.gtd-lighting.com | contact@gtd-china.com

TD-LMZ 3019 User Manual
3
Contents
Safety instructions...................................................................................................................................................................... 4
General guidelines...................................................................................................................................................................... 5
Packing and shipping .................................................................................................................................................................. 6
Unpacking ....................................................................................................................................................................................... 6
Packing after use............................................................................................................................................................................. 6
Accessories................................................................................................................................................................................. 6
Product introduction .................................................................................................................................................................. 7
Installation ................................................................................................................................................................................. 7
Clamps installation ......................................................................................................................................................................... 7
Device installation .......................................................................................................................................................................... 7
Power / Control connection ....................................................................................................................................................... 8
Power connection........................................................................................................................................................................... 8
Control connection ......................................................................................................................................................................... 8
Testing ............................................................................................................................................................................................ 9
Control panel.............................................................................................................................................................................. 9
Menu structure ........................................................................................................................................................................ 10
DMX protocol........................................................................................................................................................................... 12
Technical specification ............................................................................................................................................................. 21
Cleaning and maintenance ....................................................................................................................................................... 20
Troubleshooting ....................................................................................................................................................................... 22
System wiring diagram ............................................................................................................................................................. 23
Spare parts list ......................................................................................................................................................................... 24
Appendix 1 ............................................................................................................................................................................... 24

TD-LMZ 3019 User Manual
4
Safety instructions
WARNING!
Before using the fixture, read the latest version of the product user manual, paying particular attention
to the safety instructions. Please check www.gtd-lighting.com for the latest revision/update of the user
manual. The manufacture of this fixture, are not responsible for damages, resulting from misuse of this
fixture, due to the disregard of the information printed in this user manual.
DANGER!
Hazardous voltage. Risk of lethal or severe electric shock.
WARNING!
Burn hazard. Hot surface. Do not touch.
WARNING!
Fire hazard.
INDOORS USE ONLY!
Do not expose fixture for rain and moisture.
It’s essential that the fixture is properly grounded. Only qualified personnel should perform electrical
connections.
WARNING!
Wear protective eyewear. Never look directly into the light source.
Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts
(brackets) included with this fixture should be used for installation.
Before applying power to the fixture, check that the source voltage matches the fixture's requirement. Every fixture
must be earthed (grounded) and installed in accordance with local electricity regulations. Do not connect it to a
dimmer system.
Never look directly into the light source of this fixture to prevent risk of injury to your retina, which may induce
blindness.

TD-LMZ 3019 User Manual
5
General guidelines
Never open this fixture while in use.
The fixture should be kept clean. DO NOT operate the fixture in extreme heat or dusty environments. Avoid contact
with chemical liquid.
This fixture is a professional light effect designed for INDOOR / DRY LOCATIONS ONLY on stage, in nightclubs,
theatres, etc.
Minimum distance to lighted objects must be 3.28feet (1m).
Maximum temp of the external surface 158˚F (70˚C).
Maximum ambient temperature 113˚F (45˚C).
Minimum distance of inflammable materials from the surface 1.6 feet (0.5m).
LED lamp should be changed if damaged or distorted in shape due to extreme heat.
Cover, prism or LCD Menu Function Display with visible damages such as cracks or scratches must be replaced to
ensure performance of the fixture.
Disconnect the fixture from power before changing any parts or accessories.
Make sure that the installation area can hold a minimum point load of 10 times the weight of all installed fixtures,
clamps, cables, auxiliary equipment, etc. Check that the cover, clamps and locks are undamaged. Certified safety
cables must always be used when installing the fixture.
The fixture is only intended for installation, operation and maintenance by qualified professional. Instructions
stated in the manual must be complied.
The fixture must be kept in a well-ventilated place at least 50 cm away from any wall surface. Check if the fans or
ventilation openings are unblocked.
Broken or damaged cables can only be fixed or changed by certified technicians, certified local distributors or the
manufacturer to ensure operational safety.
Do not stick filters or other materials onto the lens. Do not modify the fixture or install other than GTD
manufactured parts.
For questions regarding safety operation, please contact our technical personnel or call the service hotline +8620
61808296.

TD-LMZ 3019 User Manual
6
Packing and shipping
Unpacking
Notes
All products are quality controlled and checked for any faults before they are dispatched to customers. If the fixture is
damaged during delivery, the customer must notify the shipper and manufacturer to file a damage insurance claim.
Photographic evidence of the damage must be provided.
Flight-Case
Open the cover of the flight-case and remove the plastic packing bags. Hold the handles of the fixture firmly and take it
out carefully.
Cardboard box
Open the box and take out the whole set of packaging foam which contains both the fixture and its accessories. Remove
the foam from the top, put away the accessories, and then take out the fixture wrapped in the plastic bag.
Packing after use
1. Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power. Cool down the fixture for
at least 15 minutes before packing.
2. Flight case: Wrap the fixture in plastic bags. Hold it by the handles, and then carefully place it inside the flight case
along with all the accessories. Close the cover. Do not upside down.
Cardboard box: Wrap the fixture in plastic bags. Put it in the packaging foam along with all the accessories. Place the
other set of packaging foam on top then carefully put it inside the cardboard box.
Accessories
Item
Qty
Unit
Notes
User Manual
1
pc
Clamp
1
set
G-clamp with 1/4-turn fasteners, for Ø 42-52mm, Max. 200 kg
safety cable
1
pc
Ø 3*8cm, with the hook , steel wire
Three-core waterproof
power adapter-Female
1
pc
0.5*2.5mm ²,Rubber, IP67
Signal Line
1
set
5m
Notes
Accessories are subject to change without any prior written notice.

TD-LMZ 3019 User Manual
7
Product introduction
1 Lens
2 Tilt
3 Driver board
4 Pan
5 Base
6 LCD display screen
7 MENU, UP, DOWN, ENTER buttons
8 Copper substrate
9 Radiator
Installation
Clamps installation
The fixture can be placed on the stage or mounted on the truss facing any direction. Attach the clamp to the mounting
position on the base of the fixture.
Warning
Use one clamp when mounting the fixture. Turn the screws attached to the clamp to lock. Always remember to use the
safety cable which goes through the mounting hole on the base. Do not attach the safety cable on the handle.
Device installation
1. Make sure there is no damage on the clamps or safety cables before installation.
2. The clamp is mounted on the base of the fixture. Horizontally insert the clamp into the mounting holes of the chassis.
Fasten the clamp tightly.

TD-LMZ 3019 User Manual
8
Power/ Control connection
Power connection
Connection method:
L (Live) Brown wire
E (Earth) Yellow / Green bi-color wire
N (Neutral) Blue wire
The voltage and frequency of the power source must be in compliance with the ones marked on the fixture. Please
apply series connection when many sets of fixtures are connected to the power source to avoid heavy load to the
power source. When the voltage is 100V, maximum 2 sets of fixtures could be allowed in each series connection.
When the voltage is 240V, maximum 4 sets of fixtures could be allowed in each series connection. Another series
connection should be set up for extra fixtures.
Notes
It is essential that each fixture is correctly grounded and the electrical installation conforms to all relevant Standards /
Codes of Practice for Safe Electrical Work.
Control connection
The fixture has 5-pin XLR connectors for DMX data input and output (3-pin optional) as shown below. Connection between
the console and fixture, and between fixtures must be made with 2 core screened DMX signal cable. Maximum connecting
distance of signal cable is 150 meters. Additional DMX512 signal-amplifier are recommended for longer distance.

TD-LMZ 3019 User Manual
9
Connect the Console’s DMX OUTPUT to the first fixture’s DMX INPUT, then the first fixture’s DMX OUTPUT to the second
fixture’s DMX INPUT and so on. It is recommended not to connect more than 32 units on a single DMX universe. On the
last fixture‘s output connect a DMX terminator. (The terminator is a XLR connector with a ¼ W and 120Ω resistor between
the pin 2 and pin 3) as shown below:
Testing
Connect the fixture to AC power. Check if the LED lamp is on and the fixture is independently controllable before putting
into operation.
Control panel
The control panel features touch-sensitive buttons and LCD digital display for quick and easy setup of address code
and functions menu.
Press UP or DOWN to view or select the function menu.
Press ENTER to choose a function and enter into corresponding sub menu. Each menu represents a specific
function of the fixture.
Press ENTER to select the specific function and save the changes or enter into the submenu, then press UP or
DOWN to change the value of the selected function (increase or decrease).
Press MENU to return to the previous menu or exit.
LED indicators:
Power on: RED power LED indicator on
Signal on: Green DMX indicator on
No Signal: Green DMX indicator off
1 2
3
2 1
3
DMX 5 12
1:接地
2:负极
3:正极
Ground
-
+

TD-LMZ 3019 User Manual
10
Menu structure
LMZ3019 –Menu Structure
Revision: A
Valid from firmware version: 1.0
Level 1
Level 2
Level 3
Level 4
Info
Run
setting
Address Setting
Value Display
Slave Address
Auto-Program
Music Program
Address: 001~
XXX
Pan ……,All,Off
Slave1,2,3
Master /Slave
Master/ Slave
Setting the DMX address
Display the channel value
Choose the slave address
Run auto program in master or slave
Run music program in master or slave
Device
Info
Time Info
Since power on
Total Time
XXXXXX Hour
XXXXXX Hour
Since power on time
Product total run time
Temperature
Body Temperature
XXX ’C/’F
Body temperature
Software
Version
X.X
The software version
System
Setting
Status Setting
Console Set Addr
No Signal Status
Pan Reverse
Tilt Reverse
Pan Scan Degree
Scan Feedback
Scan Speed
Mic. Sensitivity
Standby Time
Enable/Disable
Off/Hold/Auto/Music
Enable/Disable
Enable/Disable
630/540
Enable/Disable
Quick/Middle/Low/Slow
0~99%
Disable/1~20~99 Min
Address can be changed by console
The status while no signal
Pan Reverse
Tilt Reverse
Pan Scan Degree
Scan Feedback
Change the scan speed
Microphone sensitivity
Standby time
Fan Speed
Smart Control
High Speed
Low Speed
Auto fans speed
Fans high speed
Fans low speed
Display Setting
Backlight Time
Key Lock
Language
1~80 Min/Disable
Enable/Disable
Chinese/English
Backlight off time
Press <menu> 3s to unlock
Change the language
Temperature
Unit
Celsius
Fahrenheit
Temperature unit
Value Default
Pan……
Pan =XXX
The default value
Dimmer Mode
M0:...~M5:... M1
Dimmer mode select
Restore Default
Restore/Cancel
Restore to default value
Reset
System Reset
Scan Reset
Zoom Reset
System reset
Pan and tilt motor reset
Zoom motor reset
Channel
Adjust
Test Mode
Pan……
Every channel test
Manual Mode
Pan
:
Pan =XXX
:
Manual control
Adjust Mode
Input Password
Pan
Password=XXX(168)
Pan=XXX
The password of adjust mode
Fixed all begin position

TD-LMZ 3019 User Manual
11
:
:
Channel
Setting
Channel Mode
Standard Mode
Simplified Mode
Extended Mode
Custom Mode 1
Custom Mode 2
Custom Mode 3
Standard channel mode
Simplified channel mode
Extended channel mode
Custom channel mode 1
Custom channel mode 2
Custom channel mode 3
Set Custom
Mode1
Set Custom
Mode2
Set Custom
Mode3
Max Channel
Pan
:
Channel = XX
Pan = CH01
:
Change the channel order
Program
Edit
Select Prog.
Program Unit 1
Program Unit 2
Program Unit 3
Program 1 ~10
Program 1 ~ 10
Program 1 ~ 10
Choose build-in program for slave 1
Choose build-in program for slave 2
Choose build-in program for slave 3
Program Edit
Auto-Program1
:
Auto-Program10
Run
Step 1=Scene xxx
Step 8=Scene xxx
Choose the scene for program 1
:
Choose the scene for program 10
Scene Edit
Scene
Edit:001-250
Pan,……Pan=xxx
Scene Time=xxx
Input By Console
Edit the channel DMX
Edit the scene time
Get scene DMX form console
Record Scene
Scene XX->XX
Record scene form console
Notes
Settings highlighted in light grey are default values

TD-LMZ 3019 User Manual
12
DMX protocol
LMZ3019 - DMX Protocol
Revision: A
Valid from firmware version: 1.0
DMX protocol - Standard [22 channels]
DMX mode
Name
DMX value
DMX percentage
Function
Default
DMX
Value
Standard (22ch)
1
Strobe/Shutter
0
31
0.0%
12.2%
Closed
0(0%)
32
63
12.5%
24.7%
Open
64
127
25.1%
49.8%
Synchronous strobe from slow
to fast
128
159
50.2%
62.4%
Open
160
223
62.7%
87.5%
Random strobe from slow to
fast
224
255
87.8%
100.0%
Open
2
Intensity
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
3
Red 1
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
4
Green 1
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
5
Blue 1
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
6
Whit 1
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
7
Red 2
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
8
Green 2
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
9
Blue 2
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
10
Whit 2
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
11
Red 3
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
12
Green 3
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
13
Blue 3
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
14
Whit 3
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)

TD-LMZ 3019 User Manual
13
15
Rainbow Function
0
9
0.0%
3.5%
No function
0(0%)
10
39
3.9%
15.3%
Rainbow scene 1
40
71
15.7%
27.8%
Rainbow scene 2
72
103
28.2%
40.4%
Rainbow scene 3
104
135
40.8%
52.9%
Rainbow scene 4
136
167
53.3%
65.5%
Rainbow scene 5
168
199
65.9%
78.0%
Rainbow scene 6
200
231
78.4%
90.6%
Rainbow scene 7
232
255
91.0%
100.0%
Rainbow flow from slow to
fast
16
Color temperature
0
24
0.0%
9.4%
No function
0(0%)
25
35
9.8%
13.7%
3200K
36
46
14.1%
18.0%
3400K
47
57
18.4%
22.4%
3600K
58
68
22.7%
26.7%
3800K
69
79
27.1%
31.0%
4000K
80
90
31.4%
35.3%
4200K
91
101
35.7%
39.6%
4400K
102
112
40.0%
43.9%
4600K
113
123
44.3%
48.2%
4800K
124
134
48.6%
52.5%
5000K
135
145
52.9%
56.9%
5200K
146
156
57.3%
61.2%
5400K
157
167
61.6%
65.5%
5600K
168
178
65.9%
69.8%
5800K
179
189
70.2%
74.1%
6000K
190
200
74.5%
78.4%
6200K
201
211
78.8%
82.7%
6400K
212
222
83.1%
87.1%
6600K
223
233
87.5%
91.4%
6800K
234
244
91.8%
95.7%
7000K
245
255
96.1%
100.0%
7200K
17
Zoom
0
255
0.0%
100.0%
Near Far
0(0%)
0
65535
0.0%
100.0%
Zoom, fine (LSB)
18
Pan
0
255
0.0%
100.0%
Pan
0(0%)
0
65535
0.0%
100.0%
Pan, fine (LSB)
19
Tilt
0
255
0.0%
100.0%
Tilt
46(18.0%)
0
65535
0.0%
100.0%
Tilt, fine (LSB)
20
Scan speed
0
255
0.0%
100.0%
Scan speed from fast to slow
0(0%)
21
Dimmer Mode
0
5
0.0%
2.0%
M0:600Hz,Gama1.5,Smoth
0(0%)
6
11
2.4%
4.3%
M1:600Hz,Gama1.5,Snap

TD-LMZ 3019 User Manual
14
12
17
4.7%
6.7%
M2:1200Hz,Gama1.5,Smoth
18
23
7.1%
9.0%
M3:1200Hz,Gama1.5,Snap
24
29
9.4%
11.4%
M4:600Hz,Gama2.0,Smoth
30
35
11.8%
13.7%
M5:600Hz,Gama2.0,Snap
36
255
14.1%
100.0%
Reserved
22
Special controls
0
59
0.0%
23.1%
No function
0(0%)
60
69
23.5%
27.1%
Reset all motor after 5
seconds
70
79
27.5%
31.0%
Scan motor reset after 5
seconds
80
89
31.4%
34.9%
Zoom motor reset after 5
seconds
90
119
35.3%
46.7%
No function
120
129
47.1%
50.6%
Built-in program 1
130
139
51.0%
54.5%
Built-in program 2
140
149
54.9%
58.4%
Built-in program 3
150
159
58.8%
62.4%
Built-in program 4
160
169
62.7%
66.3%
Built-in program 5
170
179
66.7%
70.2%
Built-in program 6
180
189
70.6%
74.1%
Built-in program 7
190
199
74.5%
78.0%
Built-in program 8
200
209
78.4%
82.0%
Built-in program 9
210
219
82.4%
85.9%
Built-in program 10
220
239
86.3%
93.7%
No function
240
249
94.1%
97.6%
Dimmer mode set
250
255
98.0%
100.0%
No function
DMX protocol - Simplified [22channels]
DMX mode
Name
DMX value
DMX percentage
Function
Default
DMX
Value
Basic (22ch)
1
Strobe/Shutter
0
31
0.0%
12.2%
Closed
0(0%)
32
63
12.5%
24.7%
Open
64
127
25.1%
49.8%
Synchronous strobe from
slow to fast
128
159
50.2%
62.4%
Open
160
223
62.7%
87.5%
Random strobe from slow to
fast
224
255
87.8%
100.0%
Open
2
Intensity
0
255
0.0%
100.0%
No light Full light
0(0%)
3
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
4
Total Red
0
255
0.0%
100.0%
No light Full light
0(0%)
5
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
6
Total Green
0
255
0.0%
100.0%
No light Full light
0(0%)

TD-LMZ 3019 User Manual
15
7
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
8
Total Blue
0
255
0.0%
100.0%
No light Full light
0(0%)
9
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
10
Total Whit
0
255
0.0%
100.0%
No light Full light
0(0%)
11
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
12
Rainbow Function
0
9
0.0%
3.5%
No function
0(0%)
10
39
3.9%
15.3%
Rainbow scene 1
40
71
15.7%
27.8%
Rainbow scene 2
72
103
28.2%
40.4%
Rainbow scene 3
104
135
40.8%
52.9%
Rainbow scene 4
136
167
53.3%
65.5%
Rainbow scene 5
168
199
65.9%
78.0%
Rainbow scene 6
200
231
78.4%
90.6%
Rainbow scene 7
232
255
91.0%
100.0%
Rainbow flow from slow to
fast
13
Color
temperature
0
24
0.0%
9.4%
No function
0(0%)
25
35
9.8%
13.7%
3200K
36
46
14.1%
18.0%
3400K
47
57
18.4%
22.4%
3600K
58
68
22.7%
26.7%
3800K
69
79
27.1%
31.0%
4000K
80
90
31.4%
35.3%
4200K
91
101
35.7%
39.6%
4400K
102
112
40.0%
43.9%
4600K
113
123
44.3%
48.2%
4800K
124
134
48.6%
52.5%
5000K
135
145
52.9%
56.9%
5200K
146
156
57.3%
61.2%
5400K
157
167
61.6%
65.5%
5600K
168
178
65.9%
69.8%
5800K
179
189
70.2%
74.1%
6000K
190
200
74.5%
78.4%
6200K
201
211
78.8%
82.7%
6400K
212
222
83.1%
87.1%
6600K
223
233
87.5%
91.4%
6800K
234
244
91.8%
95.7%
7000K
245
255
96.1%
100.0%
7200K
14
Zoom
0
255
0.0%
100.0%
Near Far
0(0%)
15
0
65535
0.0%
100.0%
Zoom, fine (LSB)
16
Pan
0
255
0.0%
100.0%
Pan
0(0%)
17
0
65535
0.0%
100.0%
Pan, fine (LSB)

TD-LMZ 3019 User Manual
16
18
Tilt
0
255
0.0%
100.0%
Tilt
46(18.0%)
19
0
65535
0.0%
100.0%
Tilt, fine (LSB)
20
Scan speed
0
255
0.0%
100.0%
Scan speed from fast to slow
0(0%)
21
Dimmer Mode
0
5
0.0%
2.0%
M0:600Hz,Gama1.5,Smoth
0(0%)
6
11
2.4%
4.3%
M1:600Hz,Gama1.5,Snap
12
17
4.7%
6.7%
M2:1200Hz,Gama1.5,Smoth
18
23
7.1%
9.0%
M3:1200Hz,Gama1.5,Snap
24
29
9.4%
11.4%
M4:600Hz,Gama2.0,Smoth
30
35
11.8%
13.7%
M5:600Hz,Gama2.0,Snap
36
255
14.1%
100.0%
Reserved
22
Special controls
0
59
0.0%
23.1%
No function
0(0%)
60
69
23.5%
27.1%
Reset all motor after 5
seconds
70
79
27.5%
31.0%
Scan motor reset after 5
seconds
80
89
31.4%
34.9%
Zoom motor reset after 5
seconds
90
119
35.3%
46.7%
No function
120
129
47.1%
50.6%
Built-in program 1
130
139
51.0%
54.5%
Built-in program 2
140
149
54.9%
58.4%
Built-in program 3
150
159
58.8%
62.4%
Built-in program 4
160
169
62.7%
66.3%
Built-in program 5
170
179
66.7%
70.2%
Built-in program 6
180
189
70.6%
74.1%
Built-in program 7
190
199
74.5%
78.0%
Built-in program 8
200
209
78.4%
82.0%
Built-in program 9
210
219
82.4%
85.9%
Built-in program 10
220
239
86.3%
93.7%
No function
240
249
94.1%
97.6%
Dimmer mode set
250
255
98.0%
100.0%
No function
DMX protocol - Extended [38 channels]
DMX mode
Name
DMX value
DMX percentage
Function
Default
DMX
Value
Extended (38ch)
1
Strobe/Shutter
0
31
0.0%
12.2%
Closed
0(0%)
32
63
12.5%
24.7%
Open
64
127
25.1%
49.8%
Synchronous strobe from slow
to fast
128
159
50.2%
62.4%
Open
160
223
62.7%
87.5%
Random strobe from slow to
fast
224
255
87.8%
100.0%
Open
2
Intensity
0
255
0.0%
100.0%
No light Full light
0(0%)

TD-LMZ 3019 User Manual
17
3
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
Total Red
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
Total Green
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
Total Blue
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
Total Whit
0
255
0.0%
100.0%
No light Full light
0(0%)
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
4
Red 1
0
255
0.0%
100.0%
No light Full light
0(0%)
5
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
6
Green 1
0
255
0.0%
100.0%
No light Full light
0(0%)
7
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
8
Blue 1
0
255
0.0%
100.0%
No light Full light
0(0%)
9
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
10
Whit 1
0
255
0.0%
100.0%
No light Full light
0(0%)
11
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
12
Red 2
0
255
0.0%
100.0%
No light Full light
0(0%)
13
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
14
Green 2
0
255
0.0%
100.0%
No light Full light
0(0%)
15
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
16
Blue 2
0
255
0.0%
100.0%
No light Full light
0(0%)
17
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
18
Whit 2
0
255
0.0%
100.0%
No light Full light
0(0%)
19
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
20
Red 3
0
255
0.0%
100.0%
No light Full light
0(0%)
21
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
22
Green 3
0
255
0.0%
100.0%
No light Full light
0(0%)
23
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
24
Blue 3
0
255
0.0%
100.0%
No light Full light
0(0%)
25
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
26
Whit 3
0
255
0.0%
100.0%
No light Full light
0(0%)
27
0
65535
0.0%
100.0%
Intensity fade, fine (LSB)
28
Rainbow Function
0
9
0.0%
3.5%
No function
0(0%)
10
39
3.9%
15.3%
Rainbow scene 1
40
71
15.7%
27.8%
Rainbow scene 2
72
103
28.2%
40.4%
Rainbow scene 3
104
135
40.8%
52.9%
Rainbow scene 4
136
167
53.3%
65.5%
Rainbow scene 5
168
199
65.9%
78.0%
Rainbow scene 6
200
231
78.4%
90.6%
Rainbow scene 7

TD-LMZ 3019 User Manual
18
232
255
91.0%
100.0%
Rainbow flow from slow to
fast
29
Color temperature
0
24
0.0%
9.4%
No function
0(0%)
25
35
9.8%
13.7%
3200K
36
46
14.1%
18.0%
3400K
47
57
18.4%
22.4%
3600K
58
68
22.7%
26.7%
3800K
69
79
27.1%
31.0%
4000K
80
90
31.4%
35.3%
4200K
91
101
35.7%
39.6%
4400K
102
112
40.0%
43.9%
4600K
113
123
44.3%
48.2%
4800K
124
134
48.6%
52.5%
5000K
135
145
52.9%
56.9%
5200K
146
156
57.3%
61.2%
5400K
157
167
61.6%
65.5%
5600K
168
178
65.9%
69.8%
5800K
179
189
70.2%
74.1%
6000K
190
200
74.5%
78.4%
6200K
201
211
78.8%
82.7%
6400K
212
222
83.1%
87.1%
6600K
223
233
87.5%
91.4%
6800K
234
244
91.8%
95.7%
7000K
245
255
96.1%
100.0%
7200K
30
Zoom
0
255
0.0%
100.0%
Near Far
0(0%)
31
0
65535
0.0%
100.0%
Zoom, fine (LSB)
32
Pan
0
255
0.0%
100.0%
Pan
0(0%)
33
0
65535
0.0%
100.0%
Pan, fine (LSB)
34
Tilt
0
255
0.0%
100.0%
Tilt
46(18.0%)
35
0
65535
0.0%
100.0%
Tilt, fine (LSB)
36
Scan speed
0
255
0.0%
100.0%
Scan speed from fast to slow
0(0%)
37
Dimmer Mode
0
5
0.0%
2.0%
M0:600Hz,Gama1.5,Smoth
0(0%)
6
11
2.4%
4.3%
M1:600Hz,Gama1.5,Snap
12
17
4.7%
6.7%
M2:1200Hz,Gama1.5,Smoth
18
23
7.1%
9.0%
M3:1200Hz,Gama1.5,Snap
24
29
9.4%
11.4%
M4:600Hz,Gama2.0,Smoth
30
35
11.8%
13.7%
M5:600Hz,Gama2.0,Snap
36
255
14.1%
100.0%
Reserved
38
Special controls
0
59
0.0%
23.1%
No function
0(0%)
60
69
23.5%
27.1%
Reset all motor after 5
seconds
70
79
27.5%
31.0%
Scan motor reset after 5

TD-LMZ 3019 User Manual
19
seconds
80
89
31.4%
34.9%
Zoom motor reset after 5
seconds
90
119
35.3%
46.7%
No function
120
129
47.1%
50.6%
Built-in program 1
130
139
51.0%
54.5%
Built-in program 2
140
149
54.9%
58.4%
Built-in program 3
150
159
58.8%
62.4%
Built-in program 4
160
169
62.7%
66.3%
Built-in program 5
170
179
66.7%
70.2%
Built-in program 6
180
189
70.6%
74.1%
Built-in program 7
190
199
74.5%
78.0%
Built-in program 8
200
209
78.4%
82.0%
Built-in program 9
210
219
82.4%
85.9%
Built-in program 10
220
239
86.3%
93.7%
No function
240
249
94.1%
97.6%
Dimmer mode set
250
255
98.0%
100.0%
No function
Notes
Do not switch off the fixture within the first minute after switching on. Wait for at least 5 minutes to switch on the fixture.
Technical specification
Optical
Light source: LED 30W (RGBW 4-in-1), quantity: 19pcs
Expected average lifetime: 50000 hours
Beam angle (zoom): 3°- 25°(50% peak angle), 7° - 50°(10% peak angle)
Total Output (Lumen): 6447 lumens wide / 4834 lumens narrow
Color temperature: 3200K-7200K linear regulation
Mixing distance: 2m
Electrical
Power input, nominal: AC 100-240V, 50/60Hz
Max. Power consumption: 750W, max current: 3.3A, PF: 0.67
Power supply unit: Narrow voltage Switching power
Control and programming
Control channels (DMX): 22/22/38
Protocol: DMX-512
Display: Graphic LCD backlit
Physical / Installation

TD-LMZ 3019 User Manual
20
Weight: 7.2 kg (16 lbs.)
IP rating: IP20
Material: Aluminum, steel, plastic
Mounting points: Two quarter-turn locking points + attachment points for safety wire
Minimum distance to combustible materials: 1.64ft. (0.5m)
Minimum distance to illuminated surfaces: 3.28ft. (1m)
Dynamic effects
Pan/Tilt movement: 540˚/630˚( Pan ), 240˚( tilt)
Strobe: 1-25Hz, synchronized, pulse effects
Dimmer: 0-100%, 16-bit, electronic linear dimming (600Hz/1200Hz smooth or snap dimmer mode optional)
Thermal
Operating range: 5˚F to 113˚F (-15˚C to +45˚C)
Startup range: -13˚F to 113˚F (-25˚C to +45˚C)
Storage range: -40˚F to 140˚F (-40˚C to +60˚C)
Cooling: Active fan
Humidity: ≤85%
Connections
AC power: Neutrik powerCon
DMX data input/output: Chassis 5-pin (3-pin optional) XLR (in/out)
Certification and Safety
EMC: EN 55103-1:2009, EN 55103-2:2009, EN 61000-3-2:2006+A2:2009, EN 61000-3-3:2013
Safety: EN 60598-2-17:1989/A2:1991
Photometric
Table of contents
Popular Dj Equipment manuals by other brands

Chauvet Professional
Chauvet Professional Ovation H-265WW user manual

Equinox Systems
Equinox Systems EQLED082 user manual

American DJ
American DJ Mega Panel LED User instructions

American DJ
American DJ Aquarius II User instructions

Osram
Osram KREIOS PROFILE 80W WW manual

Lightmaxx
Lightmaxx Vega Pixel BAR user manual

Cinemeccanica
Cinemeccanica VIP Xs user manual

Chauvet Professional
Chauvet Professional EPIX STRIP TOUR Quick reference guide

Beamz
Beamz B1500 BUBBLE DOUBLE quick start guide

AlienPro
AlienPro SPLITTER 8 user manual

Future light
Future light PRO Slim Strobe SMD 5630 user manual

Eagletone
Eagletone MH710 4IN1 user guide