machine with no fluid can permanently damage the unit.
·If your experiences low output, pump noise or not output at all, unplug the power
immediately. Check fluid level, the external fuse, remote connection, and power from the
wall, if all of the above appears to be O.K., Plug the unit in again. If fog does not come out
after holding the controller's button down for 30 seconds, check the hose attached to the
tank to make sure there is fluid going through the hose, If you are unable to determine the
cause of the problem, do not simply continue pushing the controller's button, as this may
damage the unit. Return the machine to your dealer.
R-11 Remote Control Operation
5M wired multi function remote controller with 5 pin plug for Seany hazer H-900 Model.
· The interval knob adjusts the time between discharges when the timer function is
engaged. The range is from 10 seconds to 250 seconds.
· The second knob, labeled volume, controls the volume of haze produced. The range is
from 1% to 100% of maximum output.
· The TIMER button controls the timer function. Depress the button to activate. When
activated the yellow light will turn on, adjusting the interval knob will determine the time
between haze output within 10 to 250 seconds. The duration of output is set at 15 seconds.
The volume can be adjusted using the volume knob to control the amount of haze
produced.
· The CONTINUOUS button sets the machine to constant haze production. To activate this
function, depress the button of middle of R-11. The volume knob can be used to regulate
the volume of the steady stream of haze produced.
· The MANUAL button will produce a continuous blast at maximum volume while the
button held down. When released, the manual function stops and the machine will return
to the previous setting; timer; continuous; or stationary.
· Note: the continuous function will override the timer function. Therefore, if both buttons
have been depressed the Hazer will haze continuously. The manual function overrides all
functions. When depressed and held down the Hazer will haze at maximum volume for as
long as the button is held down, regardless of the machine’s setting at the time.
CONNECT DMX:
Pull down in the arrow direction to turn on. The address switch shown on the diagram is
preset as 1.
· The machine of set DMX512 signal , the connection can be finished by means of input
and output
of the triple XLR socket. The output of the control signal line must be corresponding to the
grounding wire of the LXR socket, and the lengths of the 2(-) and 3(+) signal lines should
be within
100M, prevent them might disturb other electric appliances.
Note: Some consoles can't work well unless pin2 and pin3 are exchange welding.
MAINTENANCE
Cleaning your haze machine regularly will help reduce costly parts replacement and repair