GV TC40S-PE User manual

THERMOSTAT TC40S - PE
PROGRAMMABLE DIGITAL - WHITE
USER MANUAL
I - INTRODUCTION
Technical parameters
Voltage
AC 230V, 50-60Hz
Amperage
16 A
Working environment
0ºC ~45ºC
Consumption
<0.3 W
Protection index
IP20
Programmable temperature
5ºC ~ 60ºC
Temperature control precision
0.5 ºC
Características Principais
Programs
6 daily, 3 weeklys
Probe reading options
3 (internal, external and both)
External dimensions
85mm x 85mm x 14mm
Material
PC + ABS
Screen background colo
Blue
Memory in case of electrical failure
Time and Programs
Child lock
Yes
Installation
Wall-Inserted Type
III - CAUTIONS FOR INSTALLATION
Fig. 1 - Thermostat opening
1 2 3 4 5
L1 N1 N L
6
NTC
Fig. 2 - Wiring diagram
Fig. 3 - Thermostat Installation
Heating
Manual Mode
Anti-Frozen
Child Lock
Probes Temperature
Clock
Buttons
Period
Set temperature
Week
V - THERMOSTAT INTERFACE
+
+
Button functions
Thermostat ON
Long Press
Thermostat OFF
Short Press
Thermostat ON
Short Press
----Turn on Turn O
Daily and weekly
schedule
---- Toggle automatic /
manual mode
Child Lock---- Set time and day
Increase temperature
0.5ºC continuously
---- Increase temperature
0.5ºC
Decrease temperature
0.5ºC continuously
---- Decrease temperature
0.5ºC
----
Advanced
Settings ----
-------- Floor probe reading
VI - THERMOSTAT PROGRAMMING
TURN ON/OFF
Press the button to turn on the thermostat.
Press the button again to turn o the thermostat and cut the power to the
heating cable or mat.
Dear User:
Congratulations on choosing a thermostat. Please refer to this user
manual before installing/using the thermostat.
This thermostat is used to control the temperature of heating cables or
heating mats for electric underoor heating in a given room, wether in a
domestic, commercial or industrial environment.
While we try to provide the best device possible, we are always available for
technical support. If you have any questions, please contact us.
II - TECHNICAL PARAMETERS AND MAIN CHARACTERISTICS
ATTENTION!
When being installed, this thermostat may cause an
electric shock. Make sure the installation is done by
a qualied electrician.
1. Installation should only be done when the electric supply is o, otherwise it can
damage the thermostat and cause an electric shock.
2. Choose the most suitable location for installing the thermostat (about 1,60m
above the oor). It must not be installed at eye level.
3. Installation should not be made at altitudes higher then 2000m above sea level.
IV - INSTALLATION
1. Separate the thermostat from the display using a screwdriver to press the
groove at the back of the thermostat and pushing the display upwards (g.1).
2. Follow the wiring diagram (g. 2) to connect the power, the heating cable
and the oor probe.
3. Use the two screws provided to x the outer ring and the thermostat base
to the electrician's deep box previously installed (g. 3) and make sure that it
is properly installed.
4. Attach the display to the four projections on the mounting plate and push it
downwards (never press the LCD display directly). The installation is complete.
Turn on the power to test the thermostat.
Heating Cable / Mat
16A
N (Neutral Wire)
L (Live wire)
AC220V, 50~60Hz
Floor Sensor

SETTING THE TIME AND DAY OF THE WEEK
With the thermostat on, press the symbol and the hour digits will ash.
Use the / symbols to set the time. Press the symbol again to move to
the minutes and use the / symbols to set the minutes. Press the symbol
again and the day of the week will ash. Use the / symbols to dene the
day of the week. Press the symbol to complete the conguration.
SET TEMPERATURE IN MANUAL MODE
With the thermostat turned on in manual mode, press the symbol to
increase the temperature by 0.5ºC. Press the symbol to lower the tempera-
ture by 0.5ºC.
The thermostat turns on when the probe temperature is lower than the one
set at 1.5ºC and the symbol appears on the display. The thermostat
switches o when the probe temperature is higher than the one set at 1ºC.
VII - ADVANCED SETTINGS
SEN - PROBE SELECTION
In this function you can congure the probe to be used. Use the / symbols
to set a value that can range from 0 to 2. Value 0 denes the exclusive use of
the ambient probe (internal probe). The value 1 denes the exclusive use of
the oor probe (internal probe). The value 2 denes the use of both probes
(the ambient probe controls the temperature and the oor probe limits the
temperature). The factory-set value is 0.
If option 2 is set (both probes in use), the thermostat screen in normal
operation displays the temperature of the ambient probe. You can check the
temperature of the oor probe by holding down the symbol and pressing
the symbol at the same time.
OSV - FLOOR PROBE TEMPERATURE LIMIT
This function allows you to congure the temperature limit of the oor probe.
This value denes a safety temperature, from which or thermostat switches
o, regardless of its programming. This setting only takes eect if used as two
probes (option 2 of the probe selection - SEN). Use the / symbols to set
the value that can range from 5ºC to 99ºC. The factory set value is 42ºC.
DIF - TEMPERATURE DIFFERENTIAL ASSOCIATED WITH THE THRESHOLD OF
THE FLOOR PROBE
In this function you can congure the temperature dierential associated with
the limit of the oor probe. For example, if you have set a value of 2ºC in this
option, and if you have set 40ºC in the previous function, the thermostat will
switch o at 42ºC and switch on again at 38ºC. Use the / symbols to
set the value that can go from 1ºC to 9ºC. The factory-set value is 2ºC.
SVH AMBIENT PROBE HIGH TEMPERATURE LIMIT
Function to congure the high temperature limit of the ambient probe. The
thermostat switches o when the ambient probe reaches this temperature.
Use the / symbols to set the value that can range from 5ºC to 99ºC. The
factory set value is 35ºC.
SVL - AMBIENT PROBE LOW TEMPERATURE LIMIT
Function to congure the low temperature limit of the ambient probe. The
thermostat switches o when the ambient probe reaches this temperature.
Use the / symbols to set the value that can range from 5ºC to 99ºC. The
factory set value is 5ºC.
ADJ CORRECTION OF THE AMBIENT PROBE TEMPERATURE
This function allows to correct the temperature of the ambient probe. This
correction is applied when the temperature displayed by the room probe is
not equal to the actual room temperature (measured with another external
device). This can happen due to the installation or position of the thermostat.
Use the / symbols to set this value. The factory set value is 0ºC.
FRE - ANTI-FREEZE FUNCTION
This function allows to activate or deactivate the anti-freeze function. With
this function active, the thermostat starts automatically when the tempera-
ture of the ambient probe is below the low temperature limit dened in the
SVL function. A value of 0 means that the function is o and a value of 1
means that the function is on.
PON- MEMORY FUNCTION IN CASE OF CURRENT FAILURE
Here you can dene whether or not the thermostat should store its settings in
the event of a power failure. A value of 0 means that the function is o and a
value of 1 means that the function is on.
FAC FACTORY SETTINGS
In this function you can reset all settings and functions to the factory default
values. Use the / symbols to set this value. Choosing the value 00 will
reset all the settings and settings to the factory value. If you do not want to
make changes, select the value 08.
Error
Cause
Solution
ERR
Floor Probe Error
Replace floor probe
VIII - ERROR TABLE
GLOBOVAC Ltd.
Address: Globovac Ltd, 8C Castle Road, Chelston
Business Park, Wellington, Somerset
TA21 9JQ, United Kingdom
Tel Export: +44 (0) 1293 768 210
Tel UK Costumers: +44 (0) 1293 772 165
Web: www.globovac.com
TOGGLE BETWEEN MANUAL AND AUTOMATIC MODE
With the thermostat on, press the symbol to switch between manual and
automatic mode. When the thermostat is in automatic mode, the symbol for
one of the daily settings ( , , , , , ) will appear on the display. When in
manual mode, the display shows the symbol .
DAILY AND WEEKLY SCHEDULE
This thermostat supports 6 daily and 3 weekly settings (5 + 2 days, 6 + 1 days
or 7 days). If you choose to schedule one of the weekend days separately (5 +
2 or 6 + 1), you have only 2 daily schedules for that day (s).
With the thermostat on, press the symbol for 5 seconds. When the word
“loop”is on the display, you can use the / symbols to dene the weekly
interval to be programmed.
Press the symbol again and the symbol for the rst daily schedule will
appear on the display ( ) together with the temperature to be programmed
for this time to ash. Use the / symbols to set the temperature for this time.
If you want to change the time for this daily schedule, press the symbol
and you will have the digit of the hours to ash. Use the / symbols to set the
time. Press the symbol again and the minute numbers will ash. Use the /
symbols to set the minutes. Press the symbol again if you want to change
the temperature again for this daily schedule or press the symbol to move
to the next daily schedule.
Repeat the same procedure for the remaining 5 daily schedules. If you have
chosen the weekly mode 5 + 2 or 6 + 1, repeat the procedure described above
for your daily weekend schedule.
NOTE 1: daily periods have to be programmed, none of them can be ignored.
NOTE 2: there is no opening and closing of daily periods. If you do not want
heating in the room for a certain period, you must program that period with a
suciently low temperature so that the thermostat does not start.
NOTE 3: during programming, if you do not press any button for 15 seconds,
the programming process is interrupted. The display returns to the main
screen and the changes made so far are saved.
NOTE 4:when the thermostat is operating in automatic mode, you can
manually change the temperature for that time using the / symbols. In
addition to the automatic mode symbol corresponding to the current daily
interval ( , , , , , ), the symbol is also displayed. Changes you make
manually in automatic mode are canceled when you start a new daily
schedule or by pressing the symbol twice.
CHILD LOCK
With the thermostat on, press the symbol for 5 seconds and the symbol
will appear on the display. This will block all touch functions of the thermostat
and prevent its use. To unlock, press again the symbol for 5 seconds.
With the thermostat turned o, hold down the symbol and simultaneously
press the symbol to enter the advanced settings menu.
GENERAL FUNCTIONS TABLE
Probe selection
Floor probe temperature limit
Temperature dierential associated with the threshold of the oor probe
Ambient probe high temperature limit
Ambient probe low temperature limit
Correction of the ambient probe temperature
Anti-freeze function
Memory function in case of power failure
Factory settings
SEN
OSV
DIF
SVH
ADJ
FRE
PON
FAC
SVL