Hanwha Vision SPA-S1000 User manual

IP AUDIO SERVER
User Manual
SPA-S1000

Copyright
©2023 Hanwha Vision Co., Ltd. All rights reserved.
Trademark
Each of trademarks herein is registered. The name of this product and other trademarks mentioned in this manual are the registered trademark of their
respective company.
Restriction
Copyright of this document is reserved. Under no circumstances, this document shall be reproduced, distributed or changed, partially or wholly, without
formal authorization.
Disclaimer
Hanwha Vision makes the best to verify the integrity and correctness of the contents in this document, but no formal guarantee shall be
provided. Use of this document and the subsequent results shall be entirely on the user’s own responsibility. Hanwha Vision reserves the right
to change the contents of this document without prior notice.
※Appearance, specication, etc. of the product is subject to change for performance improvements without prior notice.
The latest update is available on the ocial Hanwha Vision website. (www.HanwhaVision.com)
※The ID for the initial login is“admin,”and a password should be set.
Please change your password every three months to protect your personal data and prevent identity theft.
Please note that users are responsible for the security and other issues caused by insucient password management.
IP Audio Server
User Manual

English _3
!OVERVIEW
overview
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT
TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECT THROUGH THE
VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT.
Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids,
such as vases, shall be placed on the apparatus.
To prevent injury, this apparatus must be securely attached to the Wall/ceiling in accordance
with the installation instructions.
CAUTION
CAUTION
RISK OF ELECTRIC SHOCK.
DO NOT OPEN
CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
EXPLANATION OF GRAPHICAL SYMBOLS
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of “dangerous voltage” within the
product’s enclosure that may be of sufficient magnitude to constitute a risk of
electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to
the presence of important operating and maintenance (servicing) instructions in
the literature accompanying the product.
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
ATTENTION
IL Y A RISQUE D’EXPLOSION SI LA BATTERIE EST REMPLACÉE PAR UNE BATTERIE DE
TYPE INCORRECT.
METTRE AU REBUT LES BATTERIES USAGÉES CONFORMÉMENT AUX INSTRUCTIONS.
These servicing instructions are for use by qualified service personnel only.
To reduce the risk of electric shock do not perform any servicing other than that contained in
the operating instructions unless you are qualified to do so.
The ITE is to be connected only to (PoE/PoE+) networks without routing to the outside
plant.
The wired LAN hub providing power over the Ethernet (PoE/PoE+) in accordance with
IEEE 802.3af/at shall be a UL Listed device with the output evaluated as a Limited Power
Source as defined in UL60950-1 or PS2 as defined in UL62368-1.
Unit is intended for installation in a Network Environment 0 as defined in IEC TR 62102.
As such, associated Ethernet wiring shall be limited to inside the building.

overview
4_ overview
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean the contaminated area on the product surface with a soft, dry cloth or a damp cloth.
(Do not use a detergent or cosmetic products that contain alcohol, solvents or surfactants or oil constituents
as they may deform or cause damage to the product.)
7. Do not block any ventilation openings, Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11. Only use attachments/ accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer,
or sold with the apparatus. When a cart is used, use caution when moving the cart/
apparatus combination to avoid injury from tip-over.
13. To prevent injury, this apparatus must be securely attached to the Wall/ceiling in
accordance with the installation instructions..
14. Unplug this apparatus during lighting storms or when unused for long periods of time.
15. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged
in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into
the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been
dropped.
16. This product is intended to be supplied by isolation power.
17. If you use excessive force when installing the product, the product may be damaged and malfunction.
If you forcibly install the product using non-compliant tools, the product may be damaged.
18. Do not install the product in a place where chemical substances or oil mist exists or may be generated. As
edible oils such as soybean oil may damage or warp the product, do not install the product in the kitchen or
near the kitchen table.
This may cause damage to the product.
19. When installing the product, be careful not to allow the surface of the product to be stained with chemical
substance.
Some chemical solvents such as cleaner or adhesives may cause serious damage to the product’s surface.
20. If you install/disassemble the product in a manner that has not been recommended, the production functions/
performance may not be guaranteed.
21. Do not install on a surface where it is exposed to direct sunlight, near heating equipment or heavy cold area.
22. Do not place this apparatus near conductive material.
23. Do not attempt to service this apparatus yourself.
24. Do not place a glass of water on the product.
25. Do not install near any magnetic sources.
26. Do not place heavy items on the product.
27. Please wear protective gloves when installing/removing the product.
The high temperature of the product surface may cause a burn.
28. This device has been verified using STP cable. The use of appropriate GND grounding and STP cable
is recommended to effectively protect your product and property from transient voltage, thunderstroke,
communication interruption.
29. In particular installation environments, there might be interference in radio communications.
When interference of electromagnetic waves occurs between the product and radio communication device, it
is recommended to keep a certain distance between the two or change the direction of the receiving antenna..
30. An apparatus with CLASS construction shall be connected to a MAINS socket outlet with a protective
earthing connection.
31. Batteries(battery pack or batteries installed) shall not be exposed to excessive heat such as sunshine, fire or
the like. The battery cannot be replaced.
32. Disconnect the main plug from the apparatus, if it’s defected. And please call a repair man in your location.
33. Select an installation site that can hold at least 5 times the product’s weight.
34. Stuck-in or peeled-off cables can cause damage to the product or a fire.
35. For safety purposes, keep anyone else away from the installation site.
And put aside personal belongings from the site, just in case.
36. We do not guarantee the quality of third-party products (e.g. accessories) that you separately purchase.
37. When a PoE+ power supply is being used, high volume output may affect the system stability.
Rack Mount Instructions - The following or similar rack-mount instructions are included with
the installation instructions:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient. Therefore, consideration should be
given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma)
specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required
for safe operation of the equipment is not compromised.
C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
D) Circuit Overloading - Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention
should be given to supply connections other than direct connections to the branch circuit (e.g. use of power
strips).

English _5
!OVERVIEW
Table of Contents
OVERVIEW
3
4Important Safety Instructions
6At a Glance
7Broadcast System Configuration Diagram
7Connecting To Power And A Network
STARTING
8
8Connecting to a PC
8Access Product
11 Logging In
ENVIRONMENT SETTINGS
12
12 System Management
14 Network Settings
15 Time Settings
USE AUDIO SERVER
16
16 Home Screen Configuration
16 Operation Mode
21 System Settings
31 Maintenance

overview
6_ overview
AT A GLANCE
Front
NETWORK
MODE
POWER
a
b c d e
Rear
AC 120-240V IN
OFF POWER ON DC 24V IN NETWORK RESET
f g h i j
Name Function Description
a
Rack handle Use it when installing Audio Server.
b
Network Status LED Indicates Network connection status.
c
Status indicator Indicates Network information.
d
Mode selection dial Network information can be checked with dial.
e
Power status LED Indicates power connection.
f
AC Power code connection
terminal Provides AC Power.
Name Function Description
g
Power switch Power on/off switch.
h
Power input terminal
(DC 24 V) DC Power input terminal (DC 24 V) DC
i
Network Terminal Connects Network cable.
j
RESET
A button that returns the product settings to the factory default values. Press the button for
approximately 12 seconds to reset and reboot the product.
JDo not disconnect the power until product resetting is complete. Doing so may cause
malfunctions.
It will take up to 10 minutes to reboot the product after initializing it.

English _7
!OVERVIEW
BROADCAST SYSTEM CONFIGURATION DIAGRAM
You can configure the broadcast system by connecting speakers or microphones to the audio server.
The audio server provides the same operating GUI with the controller mode speaker and it can control multiple
speakers via button mode or the event & preset menu.
1
2
3
4
5
1 2 3
4 5 6
7 8 9
*0 #
VOLUME
MONITOR
MIC
TALK
PUSH
MAXMIN
AUX
MAXMIN
CHIME
MENU
PRESET
PREV
NEXT
CHIME
POWER
-6dB 0dB
NETWORK
+3dB +6dB
MAXMIN
ALL
Local PC
IP Speakers (ceiling-mount type)
IP Speakers (Pendant type)
IP Speakers (wall-mount type)
IP Speakers (Horn type)
IP Audio Module (Analogue Speaker)
<IP microphone>
IP Audio Server
Network
M
`There should be only one controller mode product in the broadcast system. If there are multiple controller mode speakers or
audio servers and they are repeatedly registered, proper broadcasting cannot be performed.
`The IP audio module can be used as an IP speaker when connected to an analog speaker with a permissible input of 10W or
higher and an impedance of 8 ohms.
`For the speaker, connect and use a switching hub that supports PoE or PoE+.
`Use PoE+ switch hubs that support the IEEE 802.3at standard.
`Use PoE switch hubs that support the IEEE 802.3af standard.
CONNECTING TO POWER AND A NETWORK
AC 120-240V IN
OFF POWER ON DC 24V IN NETWORK RESET
Router or switching hub
AC 120-240V IN
IP Audio Server
UPS battery
DC 24V IN
- OR -
Connecting to Network
Connect the router or switching hub to the NETWORK port of the product using a network cable.
Connecting to Power
Connect the provided power cord to the power input socket (AC 120-240V IN).
~If auxiliary power is used, connect the output of the UPS or battery to (DC 24V IN).
Network Cable Specification
Item Contents Remark
Connector RJ45 (10/100BASE-T)
Ethernet 10/100BASE-T 10/100 Mbps
Cable Category 5e
Max Distance 100 m DC Resistance ≤ 0.125 Ω/m

start
8_ start
starting
CONNECTING TO A PC
The PC should be connected to the same network as the product when accessing the product for the first time.
Use a network cable to connect the product to the switching hub that is connected with the PC.
M
`The Network microphone can receive power via PoE, or the DC power adapter can be used.
ACCESS PRODUCT
Various functions, including Operation Mode, System Settings, Maintenance, Environment Setting, and Operation
Settings, are available on the product website.
1. Set an IP address to 192.168.1.x, the same band as the product, in the Network Property of the PC. (e.g.
192.168.1.100)
2. Run a web browser on the PC.
M
`An available web browser is Google Chrome (Version 92.0.4515.131 or higher).
Google Chrome is available at www.google.com/chrome.
`It can be used in Chrome as it is a supported web browser. For the computer OS, it can be used in Windows 10 or Mac
10.15 (Catalina) or 11 (Big Sur).
Product validation was performed on Windows 10 21H2 and the Mac 10.15.7 and 11.6 versions.
3. The initial IP address of all products is 192.168.1.99.
Before installing the product, it is recommended to set a static IP address for separate products.
M
`If multiple products are connected concurrently to the same switch hub with the initial IP addresses, the web page cannot
distinguish the IP addresses, resulting in failing to set passwords.
Use Device Manager to set the initial password and IP address to use.
Registering using Device Manager
If the product is connected to a network which includes a computer where the device manager is installed,
you can search products, set up passwords, change IP addresses, upgrade firmware, and access web
pages.
Please refer to the manual of the Device Manager Program for more information.
M
`The Device Manager Program ( ) is available on the official Hanwha Visionwebsite (https://www.HanwhaVision.com)
by clicking <Support> - <Online Tool>.
1. When you connect multiple products to the switch hub, their IP addresses are 192.168.1.99, and their
status information are queried as <Need PW>.
2. Select one or multiple products and set a password to use for each product.
~If they are not queried as <Need PW>, click <New Project> ;<Search>, and set the passwords after
they are queried as <Need PW>.
~If you set a password in the [Credential] menu and press [Search] on the list screen, the status
information is queried as <Connect Fail>.
~If you press <New Project> ;<Search>, the status information is queried as <Ready>. And if you
press <Search> again, it is queried as <Connect Fail>.
M
`A password should contain 8 or more characters, and if it contains fewer than 9 characters, then a combination of 3 or more
English uppercase/lowercase letters, numbers, or special characters must be used. If it includes 10 to 16 characters, a
combination of 2 or more types must be used.
`It is recommended not to use the same character repeatedly or consecutive keyboard inputs as passwords for enhanced
security.

English _9
!START
3. Select a product to set its IP address, and enter the IP address to use (e.g., Set Static IP).
When you select products one by one
~Select <Assign the following IP address> from the [IP Assign] menu, then set its IP address.
~The DNS server address is automatically set as the product’s initial DNS address (DNS1 8.8.8.8, DNS2
8.8.4.4).
When you select multiple products
~Select <Assign the following IP address> from the [IP Assign] menu. Then apply the starting address
in the range of IP addresses to be assigned.
J
`When you select <Obtain an IP address automatically (DHCP)> from the [IP Assign] menu, the DHCP IP address is
automatically assigned.
`The HTTP port supports only the number 80, and the VNP and RTSP ports are not used in the network audio product.
4. Products with IP addresses must be logged in from the [Credential] menu to be queried as <Login OK>.
~When you execute <New Project> ;<Search>, authentication is canceled and the product is queried
as <Login Fail>.
J
`If you apply the product password in <System> ;<Device Default Credential setting> in the device manager, it is
automatically queried as <Login OK> even when you search for it as a new project or re-execute the device manager.
M
`You can update to the latest firmware for the product using the device manager.
`Check the firmware distribution information for each product on the Hanwha Vision website
(https://www.HanwhaVision.com) and download the latest firmware (modelname_version.imkp) to your PC.
You can also download the latest firmware to your PC from Device Manager.
1.
When selecting firmware for each product and running [Upgrade], the status will change to <50%> from
<Login OK>.

start
10_ start
2.
When the firmware update is completed and the system is rebooted, the status will change to <Please wait
until the program starts.>. After it reaches 100%, it will change to <Success>
3.
If you update multiple products at the same time, the update will proceed sequentially by four units at a time.
Registering with the product’s initial IP address
If you connect only one product to the switch hub, it is possible to set up the password even on the web
page.
1. Enter the product’s initial IP address into the web browser’s address bar.
2. The admin account password must be registered when accessing the product for the first time.
When the <Change Password> window appears, please enter a new password.
J
`A password should contain 8 or more characters, and if it contains fewer than 9 characters, then a combination of 3 or more
English uppercase/lowercase letters, numbers, or special characters must be used. If it includes 10 to 16 characters, a
combination of 2 or more types must be used.
`It is recommended not to use the same character repeatedly or consecutive keyboard inputs as passwords for enhanced
security.
3. A product login screen appears after successfully setting the password.

English _11
!START
LOGGING IN
Use the password set for the admin account.
1. Enter “admin” in the <ID> field.
2. Enter a password in the <Password> field.
3. Click the [Login] button to move to the Home screen of the product.
After 30 minutes of inactivity on the website, you will be automatically logged out.
J
`If you forget the password, the product has to be initialized by pressing the RESET button for about 12 seconds. Therefore,
make sure to write your password down or remember it.
If you have already logged in, the system can be initialized in the <Environment Setting> ;<System Management>
menu of the web page.
`Do not disconnect the power until the system initialization is complete after pressing the [RESET] button of the product or
during product resetting. 제품 초기화 후 재부팅까지 최대 10분이 소요됩니다.
M
`To change the network settings according to the user's network connection configuration, use the <Network Setting>
function in <Environment Setting>. (Page 14)
`Available accounts are divided into admin, setup, user, and guest by access authority level. Go to <Environment Setting>
;<System Management> ;<Change Password> to change the passwords of each account. (Page 12)
`A maximum of five users can log in to the product at the same time. The <Exceed the maximum user> screen will appear
if there is an attempt to log in while the maximum number of users are logged in, and it will show the currently connected PC
IP addresses.

environment settings
12_ environment settings
SYSTEM MANAGEMENT
Various functions are available, including System Upgrade, Change Password, System Check, Restart, and Reset.
Upgrading the System
1. Click <Environment Setting> ;<System Management> on the Home screen.
2. Click the [Upload] button in <System Upgrade>.
3. Select the upgrade file (model name_version.imkp) that you downloaded from the official Hanwha Vision
website (https://www.HanwhaVision.com) in advance and click [Open].
4. Click [Apply] to start System Upgrade. Click <OK> when the “System Restart” window appears after up
to five minutes.
J
`It may cause product malfunctions if you close or refresh the web browser before the “Restart the Program” message
appears.
`Do not disconnect the power in the middle of a system upgrade. Doing so may cause malfunctions.
5. It will take up to 10 minutes to upgrade the system and reboot the product.
The software version information of the product is available in the upper-right corner of the Home screen.
Changing the Password
You can change the passwords of each account.
1. On the Home screen, click <Environment Setting> ;<System Management>.
2. By clicking <Destination Account> from <Password Change>, select the account you want to change
and set the password.
3. Click the [Apply] button after entering a new password in the two input fields.
4. The admin account can be changed if you enter the previous password.
If you forgot the previous password, the product has to be initialized, and the passwords for all the
accounts will be initialized during the process.
5. The password of the setup, user, and guest accounts can be set, changed, or reset from the admin
account if they are forgotten.
Viewing the supported menu by account
To prevent any confusion due to arbitrary changes to the settings and to continue stable maintenance of the
system, access rights are differentiated by account, and all restricted features for each account are disabled
on the screen.
Home screen Operate Maintenance System Setting Environment Setting
admin
setup
user
guest
- admin: You can use all the functions of the product.
- setup: You can use all the functions except for environment settings, such as System Upgrade,
Change Network, Change Time, etc.
- user: Broadcast ON/OFF operation and product monitoring are available, and log records can be
checked.
- guest: You can check the product information on the home screen.
environment settings

English _13
!ENVIRONMENT SETTINGS
Unlock Account
For all accounts except the admin account, if you enter the wrong password more than 5 times when logging
in, the account will be locked for 30 seconds and you will not be able to log in.
The admin account can reset the number of retries by checking the number of login retries for each account
and whether the account is locked.
1. On the Home screen, click <Environment Setting> ;<System Management>.
2. Click [Reset] after checking the locked account on <Account lock status> The lock icon is changed to
unlocked and the number of retries for the account is reset.
Setting the System Check Time
Sets the time for the system check. The system reboots automatically at the set time every day.
1. On the Home screen, click <Environment Setting> ;<System Management>.
2. Set the time to start checking in <System Check Settings>
3. Click [Apply] after clicking the [ ] button of <Operation>.
4. The system will be checked and be rebooted at the set time; it will take approximately 5 minutes.

environment settings
14_ environment settings
Restarting System
You can restart the system without disconnecting the power when a system reboot is needed.
1. On the Home screen, click <Environment Setting> ;<System Management>.
2. Click the [Apply] button in <System Restart>.
3. Click <OK> when the system restarting window appears.
It will take approximately 5 minutes to reboot the system.
Resetting the System
Initializes every system setting to the factory default values.
An IP address of the product is also initialized to the initial status, which is 192.168.1.99.
웹 페이지를 다시 열어 192.168.1.99로 접속해 주세요.
1. On the Home screen, click <Environment Setting> ;<System Management>.
2. If you click the [Apply] button of the <All> item on <Factory Default Setting>, all set values will be reset,
and if you click the [Apply] button of the <Network status maintain> item, all set values except for
network information will be reset.
3. Click <OK> when the factory default window appears. Product initialization starts.
4. Click <OK> when the system start window appears on the web browser.
J
`Do not disconnect the power until the factory default settings are restored.
제품 초기화 후 재시작, 내부 데몬 프로그램 실행이 완료될 때까지 최대 10분이 소요됩니다.
• When the system initialization is completed, previously registered product information should
be deleted from the controller mode speaker or audio server (SPA-S1000), and you must
register if you wish to use the product.
• As the log information will be deleted when the product's system is initialized, please
download it in advance.
NETWORK SETTINGS
You can change the network settings according to the user's network connection configuration.
1. On the Home screen, click <Environment Setting> ;<Network Setting>.
~On the <Common network configurations setting>, the <Device Name> is displayed as <Name> on
the device manager's query list.
~You can enter the location of installation in <Device Location> in <Common network configurations
setting> (e.g. 6th floor, Main Building)
~You can enter the IP address, subnet mask, gateway, DNS 1 and DNS 2 server addresses for the product
by selecting <User Setting> in <Network Setting>.
`MAC address: The unique physical address of the product. (e.g. Starts with 00:1d:1d.)
`IP address: Enter the IP address available in your network band.
`Subnet mask: The subnet mask of the set IP address is indicated.
`Gateway: The gateway of the set IP address is indicated.
`DNS 1 server, DNS 2 server: Enter the primary DNS address and secondary DNS address.
~The IP, subnet mask, gateway, DNS 1 and DNS 2 server addresses for the product will be allocated
automatically from the DHCP server by selecting <DHCP Setting> in <Network Setting>.
~Click [Apply] to apply the set network information to the product.
~Click [Cancel] to return to the most recent status before changing settings.
J
`The system restarts automatically if the network settings are changed.

English _15
!ENVIRONMENT SETTINGS
TIME SETTINGS
Set the time and date accurately or it may cause problems in operating the broadcast.
1. On the Home screen, click <Environment Setting> ;<Time Setting>.
~The current time is set if you select GMT of your location on <Standard Time Zone>
~For the local network which is not connected to the external Internet, select <Manual Setting> in <Time
Setting> and enter the time manually to use it.
~If it is connected to the external Internet, select <Auto Configuration> in <Time Setting> to synchronize
the time to the standard time of the time server.
~For the domain address in the <Time Server Address> input field, use time.google.com / time.apple.com
/ pool.ntp.org / north-america.pool.ntp.org / time.bora.net / clock.isc.org.
~Please check if the domain address provides time information which reflects Daylight Saving Time.
~<Next Synchronization Time> automatically changes from the previously synced time every 8 hours.
~Click [Synchronize Now] to synchronize the time to the time server.
2. Click [Apply] to apply the set Time and Date information.
J
`If the product is used in a local network environment without an external Internet connection, the time information may
become incorrect due to the product's accumulated time errors. To accurately schedule the broadcasting time, we
recommend installing a separate time server device using GPS signals or enter the audio server IP (SPA-S1000) with high
time accuracy into the <Time Server Address> field of other products to synchronize the time information with the audio
server.
`If there is a product connected to an external Internet, enter the IP address of the product in the <Time Server Address>
field of other products before using them.
`IP audio products are not synchronized with the OS time of the PC.
M
`If the product is used in a local network environment without the external Internet connection, Daylight Saving Time is not
automatically reflected as it is not synchronized with an external time server.
`In countries where Daylight Saving Time is applicable, it is recommended for the system administrator to use the product by
changing the time manually for the start and end dates of the Daylight Saving Time.

16_ use audio server
use audio server
This is a server which can control audio products connected in the network.
To use it as a controller device, the CP of the speakers, the functions of BGM, CHIME, and TTS, have to be set up
in advance.
HOME SCREEN CONFIGURATION
The product settings are available on the web page.
ac
bd
fg e
Name Function Description
a
Home Goes to the Home screen.
Operate You can turn broadcast operation ON/OFF using the device, Audio Monitoring, Button mode, and
control mode.
System Setting Registers the device, source, and zone and sets the Event & Preset and annual schedules.
Maintenance Checks Failure History Management and Logs of the device.
Environment Setting The System Management, Network, Time, Device Information, etc. can be set.
b
Product Model Name Displays the device's model name.
c
Product Information The IP address, product name, product location, and firmware version are displayed.
d
Connected Account/Login Shows a connected account and its login status.
e
Time Information The connection time to the web page menu, product cumulative operating time, and product time
will be displayed.
f
Language Shows the language options supported on the website. (Korean, English supported)
g
Go to the Official Website If you click <Hanwha>, the screen will move to the Hanwha Vision Official Website.
M
`The optimal monitor resolution is 1920x1080.
OPERATION MODE
Device Monitoring
You can monitor the status of the source device and output device connected to the product.
M
`To monitor a device, the <Device Registration>. <Source Registration>, <Zone Registration> should be set in
<System Setting>.
Source Device
The speakers registered as the audio <Source> will be displayed in the Source Device list. <Source> means
one speaker set as a source device.
1. On the Home screen, click <Operate> ;<Device Monitoring>.
2. Click the <Source Device>.
~The number of the devices registered as the Source Device will be displayed.
~Device Name: Displays the name of the source.
~Device Location: Displays the location of the source device.
~IP address: Displays an IP address of the source device.
If you click the IP address, you can go to the website of the device.
~Status: Displays the connection status of the source device.
- : When the device is connected normally
- : When there is interference with device connection
~Source Name: The name of the Source Device will be displayed.
~Source Type: The source type of the Source Device will be displayed.
~Source Priority: The priority of the Source Device will be displayed.
~Source Icon: The setup icon of the Source Device will be displayed.

English _17
!USE AUDIO SERVER
Output Device
The speakers registered as the <Zone> of the area for broadcasting will be displayed in the Output Device
list. <Zone> refers to one speaker set as an output device.
1. On the Home screen, click <Operate> ;<Device Monitoring>.
2. Click the <Output Device>.
~The number of devices registered as the Output Device will be displayed.
~Device Name: Displays the name of the output device name.
~Device Location: Displays the location of the output device.
~IP address: Displays the IP address of the output device.
If you click the IP address, you can go to the website of the device.
~Channel : The channel will be displayed.
~Status: Displays the connection status of the output device.
- : When the device is connected normally
- : When there is interference with the device connection
~Output: Displays the play status of the output device.
- : When the device plays audio
- : When the device does not play audio
~Mute: If the [Mute] button is turned on, the audio source will not play in <Operate> ;<Button Mode>.
~Volume: Move a control bar to adjust the volume.
If the volume is adjusted, the speaker volume of the <Button mode> property is reflected on
the same level.
When the volume is adjusted, its output volume will be reflected at the same level in the
<Operation Settings> ;<DSP Setting> of the Output Device speaker.
~Level Meter: A signal value being played is indicated as a level meter.
Audio Monitoring
You can monitor the status of the Output Device speakers registered in the <Zone> of the area to broadcast.
1. On the Home screen, click <Operate> ;<Audio Monitoring>.
~Device Name: Displays the name of the output device.
~Device Location: Displays the location of the output device.
~IP address: Displays the IP address of the output device. If you click the IP address, you can go to the
website of the device.
~Status: Displays the connection status of the output device.
- : When the device is connected normally
- : When there is interference with the device connection
~Play Status: Displays the amp output status of the speaker.
- : Amp output is On
- : Amp output is Off
~Monitoring Screen: Select a device to monitor and press the [Play (+)] button, then the audio signals
detected by the device microphone will be visualized.
You cannot hear the actual output audio source.
~Volume Control: The monitoring volume can be adjusted.

use audio server
18_ use audio server
~The output monitoring device can be controlled by clicking [Play] and [Stop].
`The audio automatically stops 1 minute after it starts playing.
`Repeatedly clicking the [Play, Stop] buttons within a second may cause abnormal operation.
`When you click the [Play] button, if there is a pop-up message stating that “The sample rate of the output device is not
currently set to 48 kHz. Please change the settings.”, please change the sample speed and the bit level to 16bit, 48000hz
in the Audio Device Management Setup Menu of the PC Control Panel.
M
`After seeing the “Please select 'Condenser MIC' as the Input Mode in the Operation Setting > DSP Setting.” pop-up
message when you click the [Play] button, connect to the device and run it.
Button Mode
You can broadcast either by selecting the buttons of the source device and output device connected to the
product or by the set Event & Preset and Group formats.
If you set the transmission mode of the source device to Multicast and broadcast the BGM sound source
of the source device to the output device, the Multicast IP address and the port information of the source
device will be sent to the zone device and appear on <BGM Streaming> ;<Broadcast Client>.
If you want to use a button mode in a controller mode speaker or server, you must not change the
transmission method or operation information of the source or zone speaker in <BGM Streaming> ;
<Broadcast Server> or <Broadcast Client>.
If you press an ID number that is set for a zone or a group on the microphone (SPA-M1000) while
broadcasting a sound source in <Button Mode>, the output device can transmit the microphone instead of
the sound source.
1. Click <Operate> ;<Button Mode> on the Home Screen.
~Select Source: Connected source devices can be selected.
- The Source Name and Source Type set up in the <Source Registration> will be displayed.
The selected source device will be displayed as highlighted.
- If you click the [All Sources] button, all connected source devices will be displayed.
- If you click [ ], the source device will be shown as being moved one by one. If you click [ ],
it will switch to the last source device.

English _19
!USE AUDIO SERVER
~Source Control: BGM or TTS lists of the selected source device are displayed.
When you select a zone speaker to broadcast and select <Start Broadcasting> or <Stop
Broadcasting>, the broadcast readiness will be displayed in the source control window.
- : When the <Start Broadcasting> button is pressed (Button Mode broadcasting Standby)
- : Initial status or when the <Stop Broadcasting> button is pressed
<BGM Control Window> <TTS Control Window>
- : While all the audio sources in the BGM list are played by pressing the [ ] button, if you
press either the [ ] button or [ ] button, the previous or next audio will be played.
- : It will play or temporarily pause the selected audio source.
- : It will stop playing the audio source.
- : It will repeat playing the current audio source or all the sound sources.
- : It will play from the first audio source in the list to the last one.
M
`
Check the <CTRL> box in the <System Setting> ;<Source Registration>, and select the <Source Type> and <CTRL Type> to
display the Source Control Window.
`When you play the sound source in <BGM Control Window>, the <Broadcast Client> operation of the zone output device
is executed, and it is displayed in the level meter. When you stop playing the sound source or pause it, the level meter also
stops.
~Select Zone: An output device in the connected zone can be selected. The selected zone will be
displayed as highlighted. When you select the Source Device and Output Device and click
the [Start Broadcasting] button, the BGM or TTS icon will be displayed in the Output
Device.
- If you click the [Select/Deselect All] button, all connected zones will be selected or deselected.
- When you click the [Sort] button, they will be sorted in the order of <System Setting> ;<Zone ID>
of <Zone Registration>. The Zone button can be moved by drag and drop.
- If you click the [Move Previous] and [Move Next] buttons, it will switch to the selected devices one
by one.
- If you click the [Lock] and [UnLock] buttons, the zone selection layout can be locked or unlocked.
~Group : You can select an output group among the set groups, and duplicate selection is also possible.
The selected group will be displayed as highlighted.
When you select the Source Device and group and click the [Start Broadcasting] button, the
BGM or TTS icon will be displayed in the Output Device.
~Property: If you select a source device or zone device, information for each device will be displayed.
The output of the audio being played is indicated by a meter, and the volume can be adjusted.
M
`When you press each [Zone] button, its speaker information value will be displayed on the <Property> menu, and you can
directly control the <Volume>.
`The speaker volume of the <Property> menu is linked to the volume of <Device Monitoring> ;<Output Device>.
`The speaker volume of the <Property> menu is linked to the volume of <Output Volume Setting> of the <Operation
Setting> ;<DSP Setting> of the device.
`When you click only the source, its details are displayed in the source portion of the <Property>. When you click a zone,
details on the zone and broadcasting source will be displayed if it is on air, while only details on the zone will be displayed if it
is not on air.
`If you click the [Select/Deselect All] button, all connected zones will be selected or deselected.
`If you click the [End all broadcasting] button, all the regions' broadcasting which use the source will stop broadcasting.
Broadcasting to the region does not stop by pressing the <Event & Preset> button. The [Event & Preset] button must be
clicked and disabled to stop broadcasting.
`If you click the [Start Broadcasting] button and play audio on the STREAM or TTS window of the <Source Control>, the
selected audio of the source device will broadcast through the output device of the selected zone.
`If you click the [Stop Broadcasting] button, the selected region’s broadcasting will stop.
M
`Feedback is caused if you adjust the <DSP Setting> ;<Input Volume Setting> of zone output speakers after TTS audio
broadcasting is over or while it is paused. (Only when the same speaker is selected for the source and zone purposes in
button mode.)
Make sure to adjust the <DSP Setting> ;<Input Volume Setting> of the zone output speakers only when they are in the
[Stop Broadcasting] status.

use audio server
20_ use audio server
~Event & Preset: If you select a CP number set in the <Event & Preset> menu, it will be activated. (Up to 16 supported)
- In the <System Setting> ;<All Event & Preset List>, the events (up to 16) and Contact Closure
Number must be set up.
- If you click the Contact Closure Number, the event broadcasting configured to the zone will be
transmitted without running [Start Broadcasting].
- If you click the Contact Closure Number, a musical note will be displayed on the zone device button
selected in the <Broadcasting Routing> or <Local File Play> of <Event & Preset>.
- If you click the [ ] button on the right of the preset number, you can change the preset name.
M
`
As the zone with the musical note in the zone button box is broadcast even if they are not highlighted, ensure running [End all
broadcasting] and reconfigure it.
The zone device which can be broadcast is displayed as (Broadcasting count / Total count).
`If you manually control the speakers in <Speaker Mode> while running all the broadcasts with the <Controller Mode>
speaker, an error may occur, so please be cautious.
`If the icon is displayed on the registered device, please check the network status of the device.
`If you press the number which is set as Zone or Group mode on the microphone device during the broadcast of the
sound source in <Button Mode> and run the <Talk> function, the speaker transmits the microphone’s audio instead of
broadcasting the sound source.
`In order for the microphone to transmit the voice inputs while broadcasting, the microphone's priority must be higher than
that of the source speaker running in the <Button Mode>
`The speaker which transmits the microphone's audio displays the microphone’s information in the source information of
<Property>, and it is converted to the speaker information when <TALK> is stopped in the microphone.
Table of contents