7
STHC ed 01/03 HERCULES Condensing
A kit for connecting the storage tank to a solar panel
system can be installed (optional) inside both
HERCULES Condensing and HERCULES
Condensing ABT.
In the case of HERCULES Condensing 20 and 27, an
additional 2 pumps can also be installed inside which,
coupled with the zones control unit (see the D.I.M.
operating technical data sheet), make it possible to
divide the central heating system into 3 zones if wanted
while still enjoying a high input.
Hydraulic diagram HERCULES Condensing ABT.
Legend:
1-Condensate collector trap
2-Gas valve
3-Gas valve outlet pressure point (P3)
4-Air/gas Venturi manifold
5-Fan
6 -Gas nozzle
7-Detection electrode
8-Burner
9-Condensing module lid
10 - Condensing module
11 - Draught diverter
12 - Air analyser intake
13 - Flue analyser intake
14 -
∆
p gas pressure point
15 - Zone 1 limit NTC thermistor and High Temperature central
heating system adjustment
16 - Zone 1 High Temperature system overheat safety
thermostat
17 - 3-way delivery circulator
18 - Motorized 3-way diverter valve
19 - System expansion tank
20 - Hydraulic manifold
21 - Zone 1 High Temperature system delivery circulator
22 - Safety valve, 8 bar
23 - Polyphosphates metering unit (optional)
24 - Domestic hot water expansion tank
25 - Flow limiter
26 - Domestic hot water one way valve
27 - System filling valve
28 - Zone 1 High Temperature system one way valve
29 - Cold water inlet filter
30 - Zone 1 High Temperature system by-pass
31 - System emptying cock
32 - Safety valve, 3 bar
33 - Storage tank emptying cock
34 - 316L stainless steel storage tank
35 - Domestic hot water NTC thermistor
36 - Stainless steel coil for the storage tank
37 - Air intake pipe
38 - Positive Venturi signal (P1)
39 - Negative Venturi signal (P2)
40 - Ignition electrodes
41 -Water pressure switch
42 - Magnesium anode
43 - Motorized mixing valve
44 - Zone 2 Low Temperature system one way valve
45 - Zone 2 Low Temperature system delivery circulator
46 - Zone 2 Low Temperature system by-pass
47 - Zone 2 Low Temperature system overheat safety thermostat
48 - Zone 2 Low Temperature system modulating NTC thermistor
RA - Zone 1 High Temperature system return
MA - Zone 1 High Temperature system delivery
G-Gas supply
U-Domestic hot water outlet
E-Domestic cold water inlet
MP - Solar panels delivery (optional)
RP - Solar panels return (optional)
MB - Zone 2 Low Temperature system delivery
RB - Zone 2 Low Temperature system return
A low temperature kit can be installed inside
HERCULES Condensing 20 and 27 (optional) which,
thanks to a mixer valve and two circulators, allows
connection to combined central heating systems at
differentiated temperatures: a high temperature zone
(like radiators for instance) and a low temperature zone
(floor radiating panels for instance).
Note: This kit is a standard feature on the HERCULES
Condensing ABT version.