ETKF
Energy Saving Thermostatic Head
Data sheet 8250, Issue 1011
Energy Saving Thermostatic Head 1 8250 02
Size in mm
Version
1 8250 01 Energy Saving Thermostatic Head
The actuator with built in programmable temperature, time control and wireless receiver.
Thread connection M 28 x 1,5
Technical data Setting range: 5 °C bis 30 °C
Differential: 0,5 K
Batteries: 2 x 1,5 V AA, LR6, Battery life approx. 2 years
Receiver frequency: 868,3 MHz
max. surrent consumption: 100 mA
Ambient temperature: +5 °C bis +55 °C
max. surface temperature: +90 °C (of radiator)
linear stroke: 4,2 mm
Application
The actuator can be installed on all HERZ-TRVs with M28x1,5.
Function
This energy saving controller for radiators can be used to control room temperature an the basis of time. The actuator moves
a valve, thereby allowing the amount of heat flowing to the heating appliance to be controlled.
The controller is compatoble with the most HERZ TRVs. The large illuminated display ensures user-friendly operation. A wire-
less receiver allows the device to receive commands from taught-in system components.

Page 2
HERZ ETKF
Installation
Step 1: Inserting (replacing) the batteries
• Remove the battery compartment cover
• Insert 2 new LR6 batteries (Mignon/AA) into the battery compartment, ensuring they are the
right way round
• Reattach the battery compartment cover and click into place
New alkaline batteries have a life of approximately two years. A battery symbol ( ) will indicate when the batteries need
to be replaced. after removing the old batteries, please wait approximately 1 minute before inserting the new ones. This
device does not suport operation with rechargeable batteries.
Nevver recharge standard batteries. Doing so will present a risk of explosion.
Do not throw the batteries into a fire.
Do not short-circuit batteries.
Used batteries should not be disposed of with regular domestic waste. Instead, they should be taken to your
local battery diposal point.
Step 2: Settingthe date and time of day
The firmware version number will be displayed briefly once you have inserted/ replaced the batteries and then you will be
automatically prompted to set the date and time of day.
• Use the setting wheel (C) to set the year (B)
• Confirm with OK (D)
• Use the setting wheel (C) to set the month (B)
• Confirm with OK (D)
• Use the setting wheel (C) to set the day (B)
• Confirm with OK (D)
• Use the setting wheel (C) to set the hour (B)
• Confirm with OK (D)
• Use the setting wheel (C) to set the minute (B)
• Confirm with OK (D)
The motor will start moving back the control pin while the entries are still being made.
• If “InS” is displayed with a rotating „ “ symbol, this indicates that the motor is still moving back. Once the device is
ready for the actuator to be installed on the valve, just “InS” will appear on the display.
• The weekly program and other settings can be customised prior to installation. To do this, press the menu button when
“InS” is shown on the display.
• Once programming is complete, “InS” will reappear on the display and installation (Step 3) can commence.
Step 3: Installing the energy-saving controller
The actuator can be installed on all HERZ TRVs. There is no need to drain away water or fiddle around with the heating system
before doing this.
First, you need to remove the old thermostat dial:
• Turn the thermostat dial anticlockwise as far as it will go.
• Release the thermal ring of the thermostat.
• Remove the thermostat from the valve.
The energy-saving controller can only be installed if “InS” is showing on the display. Following installation, the actuator will
perform an adjustment run so that it can adapt to the valve. During this process, “AdA” will be displayed.
• Place the actuator on the valve.
• Tighten the union nut.
• “InS” will appear on the display, press the OK button.
• The actuator will perform an adjustment run (“AdA” will appear on the display, operation not pos-
sible).
• After that, the actuator will be ready for operation (Auto mode).
If the adjustment run was initiated prior to installation, or if an error message will be displayed (F1, F2, F3); press OK to
move the motor back to the “InS” position.

Page 3
HERZ ETKF
Setting the weekly program
The weekly program allows you to set up to 3 separate heating periods (7 switching times) for each day of the week. Pro-
gramming is performed in relation to the selected days, for which temperatures must be stored for a period from 00:00 to
23:59.
• Press and hold down the menu button for more than 3 seconds.
• “Pro” will appear on the display.
• Confirm with OK.
• “dAy” will appear on the display. The setting wheel can be used to select an individual day of the
week, all working days, the weekend or the entire week (example shows working days selected).
• Confirm with OK.
• Use the setting wheel to set the first time segment (example shows 0:00 to 6:00).
• Then, select the required temperature for the selected time segment (example shows 17.0°C).
• Confirm with OK.
• Keep repeating this process until you have finished storing temperatures for the period from
0:00 to 23:59.
In Auto mode, the temperature can be modified at any time via the setting wheel. The modified temperature will then be
retained until the next program changeover.
Weekly program: Examples
The energy-saving controller allows you to store up to 3 heating periods (7 switching times) with individual temperature
settings for each day of the week. The factory setting consists of two heating phases (from 6:00 until 9:00 and from 17:00 until
23:00 respectively) for every single day of the week:
from 00:00 to 06:00 17.0 °C
from 06:00 to 09:00 21.0 °C
from 09:00 to 17:00 17.0 °C
from 17:00 to 23:00 21.0 °C
from 23:00 to 23:59 17.0 °C
To represent the switching periods, the display shows bars for every other switching interval. In this example, no bars are
shown for the interval from 0:00 to 6:00. Bars are only shown on the display for the intervals from 6:00 to 9:00 and from 17:00
to 23:00.
If a room also needs to be heated at around noon, the corresponding program might look like this:
Monday bis Sunday
from 00:00 to 06:00 16.0 °C
from 06:00 to 09:00 22.0 °C
from 09:00 to 12:00 17.0 °C
from 12:00 to 14:00 20.0 °C
from 14:00 to 17:30 17.0 °C
from 17:30 to 23:30 21.0 °C
from 23:30 to 23:59 16.0 °C
If you have a home office and only want it to be heated during the day on working days, you can program the following
times:
Monday bis Sunday
from 00:00 to 08:30 17.0 °C
from 08:30 to 17:00 21.0 °C
from 17:00 to 23:59 17.0 °C
Saturday bis Sunday
from 00:00 to 23:59 15.0 °C
Operating modes
To switch between the 3 operating modes described below, press the menu button briefly (these operating modes can only
be selected following installation/Step 3):
• Holiday function ( ): Set a temperature that is to be maintained until a fixed point in time.
• Manu: Manual operation – The temperature is set manually using the setting wheel.
• Auto: Weekly program – The temperature is controlled automatically in accordance with the stored weekly program..

Page 4
HERZ ETKF
Configuration menu
The configuration menu can be used to modify settings. To access this menu, press and hold down the menu button (for
more than 3 seconds).
• Pro: For setting the weekly program (see Section “1 Setting the weekly program”)
• dAt: For modifying the time of day and date
• POS: For querying the actuator’s current position
• dSt: Automatic switchover at the start or end of daylight saving time can be deactivated.
• AEr: For setting the “window open” temperature and time so that the temperature is automatically reduced in the event
of ventilation
• tOF: For setting the offset temperature
• rES: For restoring the factory settings
• UnL: For teaching out all taught-• in wireless components
Use the setting wheel to select menu items and the OK button to confirm your choice. Press the menu button again to return
to the previous level. After 65 seconds without anything happening, the menu will close automatically.
Display content during normal operation
During normal operation, the following are displayed: day of the week, time of day, date, operating mode,
temperature setting and switching periods. The bars indicating the weekly program’s switching periods
are shown for every other time interval. For an example, please refer to “2. Weekly program: Examples”.
Teaching in wireless components
The actuator supports the teaching in of up to 4 system components (e.g. remote control and window contact), plus 1 wall
thermostat.
• Press and hold down the OK button for more than 3 seconds.
• The remaining teach-in time will be displayed (30 seconds).
• The device being taught-in now needs to send a wireless signal (e.g. press button on remote control).
• The display will then switch to the normal view.
Once this has been done, the actuator will respond to wireless commands from taught-in devices. Whenever the actuator
receives a signal from a window contact or remote control, the display will light up briefly.
Teaching out wireless components
Components that have been taught in on the actuator can be taught out again using the “UnL” (Unlearn) function. All wire-
less components are taught out at once with this function.
• Press and hold down the menu button for more than 3 seconds.
• Use the setting wheel to select the “UnL” menu item.
• Confirm with OK.
• “ACC” will appear on the display; press OK to confirm.
Setting the holiday function
If you want a fixed temperature to be maintained for a set period of time while you are on holiday or during a party, you can
make use of the Holiday function.
• Press and release the menu button repeatedly until the suitcase symbol ( ) appears on the display.
• Use the setting wheel to set the end of the time period during which the temperature is to be maintained.
• Press the OK button to confirm.
• Then use the setting wheel to set the date.
• Press the OK button to confirm.
• Use the setting wheel to set the temperature; press OK to confirm. The display will flash to confirm your settings.
The set temperature will remain in force until the specified time. After that, the actuator will adopt Auto mode. Wireless
commands from the window contact and remotecontrol will continue to be executed.
Comfort and set-back temperatures
The comfort/set-back temperature button ( ) provides an easy and convenient way of switching between these two
temperatures. The factory settings are 21.0°C and 17.0°C respectively. To adapt them, proceed as follows:
• Press and hold down the comfort/set-back temperature button ( ) for more than 3 seconds.
• The sun symbol ( ) will appear on the display along with the current comfort temperature.
• Use the setting wheel to modify the temperature; press OK to confirm.
• The moon symbol ( ) will appear together with the setback temperature.
• Use the setting wheel to modify the temperature; press OK to confirm.
The temperature can even be modified in Auto mode at any time by using this button. The new setting will be retained until
the program’s next switching time.
Child-proof lock/Operating inhibit
Operation can be inhibited.
• To activate/deactivate the operating inhibit, briefly press the Menu and ( ) buttons at the same time.
• Once the function is active, “LOC” will appear on the display.
• To deactivate the function, press both buttons again.

Page 5
HERZ ETKF
Setting the heating break
If the heating is being switched off for the summer, you can save battery power. This involves opening the valve up fully.
Limescale protection measures remain in place. Wireless commands from the window contact or remote control will no
longer be executed.
• To activate the heating break, turn the setting wheel clockwise during manual operation (Manu) until “On” appears on
the display.
• To terminate the heating break, quit manual operation (Manu) or turn the setting wheel anticlockwise.
Setting frost protection mode
If you do not want the room to be heated, the valve can be closed. It will only be opened again if there is a risk of freezing
due to frost. Limescale protection measures remain in place. Wireless commands from the window contact or remote control
will no longer be executed.
• To activate frost protection mode, turn the setting wheel anticlockwise during manual operation (Manu) until “OFF”
appears on the display.
• To terminate frost protection mode, quit manual operation (Manu) or turn the setting wheel clockwise.
“Window open” function
If the room is being ventilated, the actuator controls the temperature to save on heating costs. While this function is active,
the “window open” symbol ( ) appears on the display.
Without window contact: The actuator will automatically detect a significant drop in temperature due to ventilation. You
can set your own “window open” temperature and time.
With taught-in window contact: The temperature will only be reduced during the time that the window is left open. You
can set your own “window open” temperature.
• Press and hold down the menu button for more than 3 seconds.
• Use the setting wheel to select the “AEr” menu item.
• Confirm with OK.
• Use the setting wheel to set the temperature/time. Then press OK to confirm.
• Without a taught-in window contact, this function can be deactivated by selecting a time of “0”.
Setting the offset temperature
The temperature is measured at the heating appliance itself, with the result that other parts of the room may be warmer or
colder than this. To allow for this, you can set a temperature offset of ±3.5°C. If, for example, a temperature of 18°C is measu-
red somewhere within the room instead of the 20°C set, it means that an offset of -2.0°C needs to be configured.
• Press and hold down the menu button for more than 3 seconds.
• Use the setting wheel to select the “tOF” menu item.
• Confirm with OK.
• Use the setting wheel to modify the temperature.
• Press the OK button to confirm.
Restoring the factory settings
You can reset the actuator to its initial state manually. This will clear all the settings that have been made manually.
• Press and hold down the menu button for more than 3 seconds.
• Use the setting wheel to select the “rES” menu item.
• Confirm with OK.
• “ACC” will appear on the display; press OK to confirm.
Intended use
The energy-saving controller has been designed for the purpose of controlling a standard heating appliance valve. The de-
vice may only be operated indoors and must be protected from the effects of damp and dust, as well as solar radiation and
sources of radiant heat. Using the device for a purpose or in a manner other than that described in this operating manual
constitutes a breach of the “intended use” and shall invalidate the warranty and any liability claims. The same shall apply in
the event of any conversion or modification work. The devices are intended exclusively for domestic use.
Troubleshooting and maintenance Error code on display Problem Remedy
Battery symbol ( ) Battery power too low Replace batteries
F1 Valve actuator sluggish Check installation, inspect
heating valve
F2 Adjusting range too large Check actuator fastening
F3 Adjusting range too small Check heating valve
F4 1 wall thermostat already
taught in Teach out devices
F5 4 wireless components
already taught in
At 12:00 every Saturday, the actuator performs a weekly descaling function to prevent valve calcification. “CAL” will appear
on the display.

Page 6
HERZ ETKF
Instructions for disposal
Do not dispose of the device with regular domestic waste!
Electronic equipment must be disposed of at local collection points for waste electronic equipment in compliance with local
directives governing waste electrical and electronic equipment.
CE The CE sign is a free trade sign addressed exclusively to the authorities and does not warrant any properties.
Safety instructions
The devices concerned are not intended for children and must not be used as toys. Do not leave packaging material lying
around, as children might be tempted to play with it, which is extremely dangerous. Do not open the device: it does not
contain any components that need to be serviced by the user. In the event of an error, please return the device to our service
department.
Information about radio operation
Radio transmission is performed on a non-exclusive transmission path, which means that there is a possibility of interference
occurring. Switching operations, electric motors or faulty electric devices are some of the reasons why interference may oc-
cur. The range of transmission within buildings can deviate greatly from open air distances. Besides the transmitting power
and the reception characteristics of the receiver, environmental influences such as humidity and local structures also play
an important role.
Accessories
1 8250 02 Wireless remote control for radio energy-saving controller ETKF
1 8250 03 Wireless window contact for radio energy-saving controller ETKF
1 8250 04 USB programming stick for radio energy-saving controller ETKF
1 6350 03 Thermostats Adapter Ring for T&A Thermostatic Valves (threaded connection M 28 x 1,5)
1 6357 11 Thermostats Adapter Ring „H“ (threaded connection M 30 x 1,5)
1 6351 01 Thermostats Adapter Ring for Caleffi Thermostatic Valves (threaded connection M 30 x 1,5)
1 6362 01 Thermostats Adapter Ring „D“ (threaded connection M 20 x 1)
1 6362 11 Thermostats Adapter Ring for „D“ (threaded connection M 23,5 x 1,5)
Radio remote control 1 8250 02
Buttons and display
A Set temperature, actual temperature
B Set-back temperature ( ), comfort temperature ( )
C - button: activates the set-back temperature
D Minus button (-): reduces the set temperature
E “Battery empty” symbol ( )
F Temperature display: relative temperature change (set) or current temperature
(actual)
G Transmission symbol/radio transmission ( )
H - button: activates the comfort temperature
I Plus button (+): increases the set temperature
Intended use
The remote control is a user-friendly device for changing the temperature in a room. If the remote control has been taught-in
to a radio energy-saving controller for radiators (see 5), these system components can receive commands from the remote
control and implement them. An integrated temperature sensor also detects the current ambient temperature, which can
be seen on the remote control’s display.
The remote control can be used to perform two types of operation:
• Implementing a relative t • emperature change (-/+)
• Switching to the set-back ( ) or comfort temperature ( )
The device may only be operated indoors and must be protected from the effects of damp and dust, as well as solar or heat
radiation.
Using the remote control for any purpose other than that described in this operating manual does not fall within the scope
of intended use and shall invalidate any warranty or liability. This also applies to any conversion or modification work.
This device is intended for private use only.
A
B
C
D
E
F
G
H
I

Page 7
HERZ ETKF
Inserting (replacing) batteries
The remote control runs on two LR44 batteries.
• Remove the battery compartment cover.
• Insert two new LR44 batteries in the battery compartment (making sure that you insert them the right
way round).
• Replace the battery compartment cover and latch it into position.
If the remote control is used twice a day, new batteries will have a service life of approximately four years.
A battery symbol ( ) on the display indicates that the batteries need to be replaced.
Never recharge standard batteries. Doing so will present a risk of explosion.
Do not throw batteries into a fire.
Do not short-circuit batteries.
Used batteries should not be disposed of with regular domestic waste. Instead, take them to your local
battery disposal point.
Operation
The remote control features an integrated temperature sensor.
Pressing a button briefly will cause the current actual temperature to appear on the display.
Please note that the detected temperature may be affected by body heat. If you hold the remote control in your hand for
a long period or carry it around in a trouser pocket, the temperature measured by the sensor may be very different to the
room’s actual ambient temperature.
As well as displaying the actual temperature, the remote control can also be used to perform two types of operation:
1) Implementing a relative temperature change:
Here, the room’s current set temperature is increased (e.g. +2.5°C) or decreased (e.g. -1.0°C) by the value set on the remote
control.
• The -/+ buttons are used to increase or decrease the temperature in 0.5°C increments.
• Once the buttons have been pressed as many times as required, there is a short delay before the
temperature change is transmitted and the transmission symbol appears on the display.
• The display switches off after 10 seconds of inactivity.
If the display is still active, changing the temperature again will cause only the new temperature difference 17 to be transmit-
ted. If the display has already switched off after 10 seconds of inactivity, the temperature change starts again from 0°C.
2) Comfort temperature/Set-back temperature
The - buttons are used to activate the comfort/setback temperatures stored in the radio energy-saving controller.
• Pressing the - or - button activates the corresponding setback or comfort temperature.
• Once the button has been pressed, there is a short delay before the information is transmitted
and the transmission symbol appears on the display.
• The display switches off after 10 seconds of inactivity.
After a short delay, five seconds of transmission starts, during which time the transmission symbol is visible on the display.
If a new operation is performed during these five seconds, the change will not be transmitted until the five seconds have
elapsed.
Teaching-in to radio components
In order to enable communication between radio components, the devices have to be taught-in to one another. The remote
control can be taught-in to system components such as a radio energy-saving controller for radiators.
• First of all, the receiver must be set to teach-in mode. For more information on this, refer to the operating manual for the
relevant device.
• Next, the remote control has to transmit a signal in order to be taught-in. To do this, press one of the buttons two or three
times.
• Please note that the batteries must have already been inserted.
• During transmission, the transmission symbol appears on the display.
A remote control can be taught-in to as many actuators as you wish.
Technical characteristics
Supply voltage: 3 V
Batteries: 2x LR44
Battery life: 4 years approx. (at two operations per day)
Transmission frequency: 868,3 MHz
Range of transmission
in the open air: 30 m
Housing dimensions: 41 x 74 x 15 mm (W x H x D)

Page 8
HERZ ETKF
Radio shutter (window) contact 1 8250 03
Intended use
This window contact is used to detect when a window is opened. If the window contact is taught-in to a radio energy- saving
controller (see 6), these devices will automatically reduce the temperature in the room during ventilation. Using the automa-
tic temperature reduction function whilst windows are open enables heating costs to be lowered.
The device may only be operated indoors and must be protected from the effects of damp and dust, as well as solar or other
methods of heat radiation. Using the device for any purpose other than what is described in this operating manual does
not fall within the scope of intended use and shall invalidate any warranty or liability. This also applies to any conversion or
modification work. This device is intended for domestic use only.
Overview
1 1 2 2
Magnet Window contact Electronic unit
Preparing for mounting
The window contact consists of two fundamental elem-ents: a magnet (1) and an electronic unit (2).
One of the elements must be mounted on the frame, the other on the window. This ensures that,
when the window is opened, the electronic unit registers that the magnet is no longer in the imme-
diate vicinity and a “window open” signal is transmitted.
Installation location:
• First select the window • that is frequently used for ventilation and which the window contact is to be
attached to.
• The magnet (1) can be installed on the left or right of the electronic unit (2).
• The electronic unit (2) must be attached upright with the release clip (3) at the top.
• The magnet (1) and electronic unit (2) may not be any more than 8 mm (A) apart.
• The magnet (1) and electronic unit (2) must be attached next to one another so that they are level (B).
• The magnet (1) and electronic unit (2) must be positioned so that they are in alignment next to one ano
ther (C).
Mounting
• The magnet (1) and electronic unit (2) may not be any more than 8 mm (A) apart.
• The magnet (1) and electronic unit (2) must be attached next to one another so that they are level (B).
• If necessary, use a pen to mark the bore hole positions (a) for the magnet (1) and electronic unit (2) on
the frame and window.
The magnet (1) and electronic unit (2) can be fastened in two ways:
3
A
C
1
2
1
3
a
a

Page 9
HERZ ETKF
Adhesive strip method
• This does not damage the door or window in any way.
• Use the adhesive strips supplied.
• Stick the strips on the rear sides of the brackets (1 and 2).
• Then press the brackets onto the frame and window.
Screw method
• If you are working with a hard surface, you should drill the holes marked (a) using a 1.5 mm drill.
• Use the countersunk head screws supplied to fasten the electronic unit (2).
• Once fastened, the magnet (3) can be inserted in the magnet bracket (1). Then place the cap on the
magnet.
Using screws will damage the frame and/or window. For those living in rented accommodation, this could lead to a landlord
making a claim for compensation or holding back a tenant’s deposit.
Inserting (replacing) batteries
The window contact is operated with 2 micro (LR03/AAA) batteries.
• Push the release clip (1) backwards.
• Pull the upper part of the device up and at an angle (2), and remove it from the bracket.
• Insert 2 new micro batteries (LR03/ AAA) in the battery compartment (3) of the upper part (making
sure they are the right way round).
• Place the upper part back onto the bracket, allowing it to latch into place.
The service life of new alkaline batteries is approximately 5 years, based on opening the window twice a day for two hours
at a time. If the LED flashes three times when the window is opened or closed, this indicates that the batteries need to be
replaced.
Never recharge standard batteries. Doing so will present a risk of explosion.
Do not throw the batteries into a fire.
Do not short-circuit batteries.
Used batteries should not be disposed of with regular domestic waste. Instead, they should be taken to
your local battery disposal point.
Teaching-in to radio components
To enable radio components to communicate with one another, they need to be taught-in to one another. The window
contact can be taught-in to system components such as a radio energy-saving controller for radiators.
• The first step is to switch the receiver to teach-in mode. For information on how to do this, please refer to the
operating manual for the relevant device.
• Following this, the window contact needs to transmit a signal for teaching-in purposes. To initiate this, open or close
the window.
• If the window contact has not yet been installed, you can simply separate the magnet and electronic unit or rest them
against one another. However, please note that the batteries must already have been inserted in order to do this.
• When a signal is transmitted, the window contact LED lights up.
A window contact can be taught-in to any number of actuators.
LED flashing sequences & transmission behaviour
The LED’s flashing sequences have different meanings:
Flashing
sequence Meaning
1x flash Contact/window closed
2x flashes Contact/window open
3x flashes Replace batteries
If, whilst a signal is being transmitted (after the window has been opened or closed), the window contact detects that the
battery power is too low, the LED will emit the “replace batteries” flashing sequence once the signal has finished transmit-
ting.
After a window has opened or closed, the window contact transmits a signal for 5 seconds. Any further changes that are at-
tempted while the signal is being transmitted will not provoke a response. However, if the position has been changed during
this time, the new status will be transmitted directly afterwards and indicated by an LED flashing sequence.
a
2
a
1
3
2

Page 10
HERZ ETKF
Technical characteristics
Supply voltage: 3 V
Batteries: 2x LR03 / Micro / AAA
Battery life: Approx. 5 years (window opened twice a day for 2 hours at a time)
Transmission frequency: 868,3 MHz
Range of transmission
in open air: 30 m
Housing dimensions
Electronic unit: 15 x 100 x 22 mm (W x H x D)
Magnet: 12 x 48 x 12 mm (W x H x D)
USB programming stick 1 8250 04
Intended use
The USB programming stick is used to program system components such as radio energy-saving controllers. The USB stick
does not have any controls and must be used in conjunction with the associated PC software. The device may only be ope-
rated indoors and must be protected from the effects of damp and dust, as well as solar or heat radiation. Using the device
for any purpose other than that described in this operating manual does not fall within the scope of intended use and shall
invalidate any warranty and exempt HERZ from any liability. This also applies to any conversion or modification work. The
device is intended for private use only.
Operation
Programming settings are made using the associated PC software. For more information see Section “PC software”. The PC
software uses the USB programming stick to send the weekly programme, along with the date and time, to devices that are
ready to receive. For more information see Section “Radio transmission of programming settings”.
PC-Software
The PC software for the USB programming stick can be downloaded from www.herz.eu. The corresponding file can be
found in the “Download” area. Follow the on-screen instructions when downloading the PC software.
Radio transmission of programming settings
So that the USB programming stick can send data to system components such as radio energy-saving controllers, these
components must first of all be set to teachin mode.
• The USB programming stick must be plugged into the PC’s USB port.
• The PC software must be running on the PC and programming must be complete.
• For transmission, the receivermust be set to teach-in mode. For more information on this, refer to the operating manual
for the relevant device.
• The USB programming stick can now send data to the devices that are ready to receive. To start the transmission
process, activate the transmission function in the PC software.
The USB programming stick does not remain permanently taught–in on the devices to be programmed.
If the USB programming stick is being used to send a weekly programme, all devices that are ready to receive will receive
the programme accordingly. An unlimited number of receivers can be programmed.
When being put into operation for the first time, a radio energy-saving controller can be switched to teach-in mode im-
mediately after data entry (please see the corresponding operating manual for detailed instructions). If a wireless signal is
received from the USB programming stick during the teach-in period, the radio energy-saving controller will change over to
continuous reception and PCC (PC configuration) will appear on the display. You can exit PCC mode again by pressing the
OK button.
System requirements
• Windows® XP, Windows Vista™, Windows 7™
• USB connection
Remedy
If no data is being sent to the radio energy-saving controller, you can check the following:
Range:
Make sure that the receivers are located in the wireless range of the USB programming stick.
Receive mode:
The receiving devices must be set to teach-in mode during transmission.
PC software:
Data cannot be sent unless the corresponding PC software has been installed and activated. The USB stick must also be
plugged into the PC’s USB port; the operating system will detect the USB programming stick automatically.

Page 11
HERZ ETKF
The help texts in the PC software indicate whether or not the operating system has detected the USB programming stick
correctly.
• Whe n the sof t wa re is re ady to se nd dat a , the “Submit” button will be available for selection and “USB programming
stick is ready” will appear on the bottom left of the display.
• If the USB programming stick cannot be detected or is not plugged in, “Please insert the USB programming stick” will
appear.
You should make sure that you always have the latest updates for your Windows operating system installed.
If the PC software is unable to find the programming stick, you can look for it in the Windows Device Manager:
• The device will be listed as an “HID-compliant device” under “Human Interface Devices”.
• With the Device Manager open you can unplug the USB programming stick and plug it back in; it should then appear in
the list of devices.
• If an exclamation mark appears in front of the device, you should update the Windows drivers. For more information
please refer to the corresponding Windows Help.
Technical characteristics
Power supply: USB connection
Transmission frequency: 868,3 MHz
Open air range: 10 m
Housing dimensions: 23 x 9 x 81 mm (W x H x D)
Accessories
1 6350 03 Thermostats Adapter Ring for T&A Thermostatic Valves (threaded connection M 28 x 1,5)
1 6357 11 Thermostats Adapter Ring „H“ (threaded connection M 30 x 1,5)
1 6351 01 Thermostats Adapter Ring for Caleffi Thermostatic Valves (threaded connection M 30 x 1,5)
1 6362 01 Thermostats Adapter Ring „D“ (threaded connection M 20 x 1)
1 6362 11 Thermostats Adapter Ring for „D“ (threaded connection M 23,5 x 1,5)
Table of contents
Popular Audio & Video Accessories manuals by other brands

Delta
Delta TR-1B P2 Series user manual

FILM LIGHT
FILM LIGHT Truelight SDI user guide

Roberts Gorden
Roberts Gorden nRG Control Installation, operation and service manual

Octava
Octava HDLAN | PoE-EX Installation guides

Atlona
Atlona AT-HD800 user manual

Lutron Electronics
Lutron Electronics Energi Savr Node QSN-4T16-S installation guide