4
Operation Guide
After connecting and turn on the power, the button LEDs will turn on in blue, and the Central FB
button will turn on in White.
Disassembling the glass will be done using
a flat screwdriver in the left center of
the panel.
Assembling the glass after power on,
will be made when the panel is in locked mode.
20 seconds after assembling the glass you will be able unlock the panel, refer to page 6.
Button LEDs will decrease their intensity after 2 minutes, a short press on any button will increase
the intensity back.
FB button LEDs color
Blue – Panel locked.
Red – Network disconnected
Green – Network connected
White – Factory mode
Yellow – FW updated successfully
Operation Buttons' LEDs color
Blue – channel off.
Green – channel On.
Light blue – Copy button.
Yellow – Scenario button.
Red – Momentary button.
Download HIGOAL App from App store / Play store,
follow instructions and input all user details.
Scan each panel separately in order to connect it to
the Wi-Fi and App
In a plaster wall, install
a 3-gang wall mount
without butterfly screws.
R1
R2
FB
To use 2 dry contact
outputs as 110/220V,
bridge between C and L
2 dry contact
inputs for
outputs
12V
K1 K2 - +
3
Dipswitch
Under the panel glass there is a dipswitch which used to configure (using the attached pin)
On-Off mode / Shutter mode / Shutter work time / Momentary mode / Safety mode. Configure
buttons before scanning.
Dipswitch
1. Default work time for shutter mode is 1 min, in order to change
time, turn dipswitch 2 to On and set dipswitches 4/5
2. Dry contacts are parallel to buttons, for integrating 3rd party
systems, sensors and external switches
3. Built in 12v / 0.5amp power supply for external sensors
4. Setting timer mode to output is suitable with external sensor
connected by dry contact
5. Momentary mode – suitable with HIGOAL dimmer board
4 Work times
for outputs
(Timer Mode,
Shutter)
TIME 1
1 min
TIME 2
Momentary
TIME 3
3 mins
TIME 4
7 mins
5/8
4/7
5/8
4/7
5/8
4/7
5/8
4/7
8
7
6
5
4
3
2
1
Timer On
Safety On
Timer On
Shutter mode
Timer Off
Safety Off
Timer Off
On-Off mode
OFFON
Dipswitches 7/8 – Output 2 work time
Dipswitch 6 – Output 2 timer On-Off
Dipswitches 4/5 – Output 1 work time
Dipswitch 3 – Output 1 Safety mode
Dipswitch 2 – Output 1 timer On-Off
Dipswitch 1 – Outputs 1/2 Shutter mode
8
7
6
5
4
3
2
1
ON/OFF
INSTALLATION AND SAFETY GUIDE
2
Maintain a steady, straight installation against
the wall.
Assembling panel's glass can be done in one
direction only.
Assembling the panel to the wall mount
(3/4 gang box) using the attached screws.
Shutter connection/Wiring A momentary button
requires changing the Dipswitch status.
A guide is attached to every smart panel.
C = Common power input
R1 = 1st output, 5amp
R2 = 2nd output, 5amp
+12 = 12v power supply, 0.5 amp
-12 = common power supply and dry contact
K1 = Dry contact for R1
K2 = Dry contact for R2
Installation will be performed by a certified expert.
Disconnect main power before installation.
Wires connection will be done according the diagram
in the back of the panel.