Gas Leakage Inspection
Please use gas leakage detector to check if
leakage occurs at the connection of Flare nut
as shown on the right.
If gas leakage occurs, further tighten the
connection to stop leakage.
FINAL STAGE OF INSTALLATION
Insulation And Maintenance Of Pipe Connection
1
●The connected terminals should be completely sealed with
heat insulator and then tied up with rubber strap.
●Please tie the pipe and power line together with vinyl tape
as shown in the figure showing the installation of Indoor and
Outdoor units. Then fix their position with holders.
●To enchance the heat insulation and to prevent water
condensation, please cover the outdoor part of the drain hose
and pipe with insulation pipe.
●Completely seal any gap with putty.
Installation Of Remote Controller
2
Power Source And Operation Test
3
●The remote controller can be placed in its holder which is
fixed on wall or beam.
●To operate the remote controller at its holder, please ensure
that the unit can receive signal transmitted from the controller
at the place where the holder is to be fixed. The unit will beep
when signal is received from the remote controller. The signal
transmission is weaken by the fluorescent light. Therefore,
during the installation of the remote control holder, please
switch on the light, even during day time, to determine the
mounting location of the holder.
Power Source
CAUTION
●Please use a new socket. Accident may occur due to the use
of old socket because of poor contact.
●Please plug in and then remove the plug for 2 – 3 times. This
is to ensure that the plug is completely plugged into the socket.
●Keep additional length for the power cord and do not render the
plug under external force as this may cause poor contact.
●Do not fix the power cord with U-shape nail.
Operation Test
●Please ensure that the air conditioner is in normal operating
condition during the operation test.
●Explain to your customer the proper operation procedures
as described in the user’s manual.
<
IA1126: A
>
The controller must
be hooked onto the
hook at the lower
part of the holder.
Push in the remote
controller in the
direction as shown
in figure beside.
Preparation of Pipe
1
●Use a pipe cutter to cut the copper pipe.
●Jagged edge will cause leakage.
●Point the side to be trimmed downwards during trimming to prevent copper
chips from entering the pipe.
●Before flaring, please put on the flare nut.
Pipe Connection
2
INSTALLATION OF REFRIGERATING PIPES AND AIR REMOVAL
CAUTION
WARNING
●If you cannot attach the side cover
due to the connecting cord, press the
connecting cord in direction to the front
panel to fix it.
●Be sure that the hooks of the side cover
is fixed in certainly. Otherwise water
leakage may occur and this causes short
circuit or faults.
●The connecting cord should not touch
to service valve and pipes. (It becomes
high temperature in heating operation.)
Checking for the electric source
and the voltage range
●Before installation, the power source must be checked and
necessary wiring work must be completed. To make the
wiring capacity proper, use the wire gauges list below for
the lead-in from a pole transformer and for the wiring from
a switch board of fuse box to the main switch and outdoor
unit in consideration of the locked rotor current.
●THIS APPLIANCE MUST
BE EARTHED.
Procedures of Wiring
Wiring of The Outdoor Unit
●Please remove the side cover for wire connection.
CONNECTION OF POWER CORD
●Please be careful when bending the copper pipe.
●Screw in manually while adjusting the center. After that, use of torque wrench to
tighten the connection.
WARNING
In case that power is supplied from Indoor Unit
●Please use exclusive
tool
CAUTION
In case of removing flare nut of an Indoor unit, first remove a nut
of small diameter side, or a seal cap of big diameter side will fly
out. Prevent water from entering into the piping when working.
Power line Control line
GRN + YEL
How to Attach the Front Cover
1 After covering the front cover to the unit, certainly hook
at the upper portion (four places). Then, check that the
drain pan is certainly attached. Push the front cover in
the direction of arrow at the
portion of hooks.
2 Hook the front cover at lower portion to the drain pan and
then fix them by screws and attach the caps.
3 Attach the front panel.
●Certainly insert the left shaft of the front panel to the hole
of the front cover. Next insert the right shaft as same as
the left.
4 Attach the filters which are placed the surface written
“FRONT” up.
●After attaching the filters, push the front panel at three
arrow portion as shown in figure and close it.
Hole
How to Remove The Front Cover
1 Open the front panel.
●Please remove and attach the
front panel by both hands.
●After opening the front panel by both hands.
1 Undo the right arm while pushing it inside.
2 Slide the front panel to right as shown in figure. Then
remove while pulling it to front.
2 Remove the filters.
3 Remove the caps and screws
at the lower portion of the
front cover.
4 Pull the front cover upward as far
as the location where the lower
portion of the front cover is on
the deflector.
5 Remove while pulling the front
cover in direction to arrow as
shown in figure to hold the both
sides of front cover.
Screw
Lower portion of front cover Deflector
Removal Of Air From The Pipe And Gas Leakage Inspection
3
Procedures of using Vacuum Pump for Air Removal
As shown in right figure, remove
the cap of valve core. Then,
connect the charge hose. Remove
the cap of valve head. Connect
the vacuum pump adapter to the
vacuum pump and connect the
charge hose to the adapter.
Fully tighten the “Hi” shuttle of
the manifold valve and completely
unscrew the “Lo” shuttle. Run the
vacuum pump for about 10–15
minutes, then completely tighten
the “Lo” shuttle and switch off the
vacuum pump.
2
Completely unscrew the spindle of
the service valve (at 2 places) in
anti-clockwise direction to allow the
flow of coolant (using Hexagonal
Wrench key).
3
Remove the charge hose and
tighten the cap of valve head.
Check the cap’s periphery if there
is any gas leakage. The task is
then completed.
4
1
AIR REMOVAL
●The naked part of the wire core should be 10 mm and
fix it to the terminal tightly. Then try to pull the individual
wire to check if the contact is tight. Improper insertion
may burn the terminal.
●Be sure to use only power cables approved from the
authorities in your country. For example in Germany:
Cable type: NYM 3x1.5mm2, (fuse = 30A time delay)
●Please refer to the installation manual for wire connection
to the terminals of the units. The cabling must meet the
standards of electrical installation.
●There is a AC voltage of 220~230V between the L, N,
A and B terminals. Therefore, before servicing, be sure
to remove the plug from the AC outlet or switch off the
main switch.
WARNING
OUTDOOR UNIT
●Please mount the outdoor unit on
stable ground to prevent vibration
and increase of noise level.
●Decide the location for piping after
sorting out the different types of
pipe available.
●Open the side plate by unscrewing
the screws as shown below.
Please
remove
side cover
when
connecting
the piping
and
connecting
cord.
CAUTION
Please make sure to remove all
spacers inside the unit.
●Open the Top, Back and Side
cover of the unit.
●Pull out the spacers inside.
(Spacers are only for transportation
purpose).
If not remove, vibration and noise
will occur.
Top cover
CONDENSED WATER DISPOSAL OF OUTDOOR UNIT
There are holes on the base of Outdoor unit for condensed water to exhaust.
In order to flow condensed water to the drain, the unit is installed on a stand
or a block so that the unit is 100mm above the ground as shown figure.
Join the drain pipe to one hole.
At first insert one portion of the hook to the base (Portion A), then pull the
drain pipe in the direction shown by the arrow while inserting the hook into
the base. After installation, check whether the drain pipe cling to the base
firmly.
When using in cold region, etc.
In cold region with severe cold climate and heavy snow, water discharged
from heat exchanger freeze on the base surface and this may affect
drainage. In such a region, remove bush on the bottom face of outdoor unit
for better drainage. When using drainpipe, consult our dealer.
Side cover
Back cover
●Investigate the power supply capacity and other
electrical conditions at the installation location.
Depending on the model of room air conditioner to be
installed, request the customer to make arrangements
for the necessary electrical work etc.
The electrical work includes the wiring work up the
outlet. In localities where electrical conditions are
poor, use of a voltage regulation is recommended.
IMPORTANT
Fuse Capacity
30A time delay fuse
AB
Wiring Of The Indoor Unit
●
For wire connection of the Indoor unit, you need to remove front panel
and electrical cover.
Method to remove front panel
●
Refer to “FINAL STAGE OF INSTALLATION – How to Remove The
Front Cover”.
Method to remove electrical cover
●
Remove the screw and electrical cover.
●
Insert the connecting cord (A, B, C, D) from the bottom of unit.
●
Fixed the wire to terminal wires firmly as shown in figure at
right side.
ScrewElectrical coverScrew
CD
CAUTION
Outdoor supply cords shall not be lighter than
polychloroprene sheathed flexible cord with code
designation 60245 IEC 57.
IMPORTANT
Cable length
up to 16m
up to 15m
up to 25m
Wire cross-section
1.5mm2
2.5mm2
4.0mm2
Outer
Diameter (mm)
6.35 (1/4")
9.52 (3/8")
12.7 (1/2")
For R410A tool
0.0 ~0.5
0.0 ~0.5
0.0 ~0.5
For R22 tool
A (mm) Rigid Flaring Tool
1.0
1.0
1.0
Outer
dia.of pipe
6.35 (1/4")
9.52 (3/8")
12.7 (1/2")
6.35 (1/4")
9.52 (3/8")
12.7 (1/2")
Valve
head cap
Torque N·m
(kgf
·
cm)
13.7 – 18.6 (140 – 190)
34.3 – 44.1 (350 – 450)
44.1 – 53.9 (450 – 550)
19.6 – 24.5 (200 ~ 250)
19.6 – 24.5 (200 ~ 250)
29.4 – 34.3 (300 – 350)
12.3 – 15.7 (125 ~ 160)
Small dia. side
Large dia. side
Valve core cap
Small dia. side
Large dia. side
[For all optional part, please refer catalog for part number]
As for connecting to H-Link, a separately purchased
RAC Adapter is required.
●To install the wiring the electrical box cover must be opened.
●Connect the connector of RAC adapter to CN1101.
●Assemble back the cover of electrical box.
●Please refer to the respective user manual of RAC Adapter
for further details.
●Please be careful not to damage lead wires by edge of
plate when connecting the optional parts.
[For all optional part, please refer catalog for part number]
Connection to the electrical box:
●Remove the cover of electrical box.
●Connect the connector of Weekly Timer/wired remote
controller to CN1102.
●Assemble back the cover of electrical box.
●Please refer to the respective user manual of Weekly Timer/
wired remote controller for further details.
●Please be careful not to damage lead wires by edge of
plate when connecting the optional parts.
WEEKLY TIMER / WIRED REMOTE CONTROLLER
H-LINK
How To Connect The Optional Parts
(RAC Adapter, Weekly Timer, Wired Remote Control)
BASE
DRAIN PIPE
Please face this side
(suction side) of the
unit to the wall.
Pull
downward
Indoor
Unit
Outdoor
Unit
GRN + YEL
Strip wires
After remove the screw
and band, put the
connecting cords and fix
the band with screw.
Connect the
earth cord
LN
Earth terminal
Cap
Shaft
Guide
INS RAS-30MH1-EN2 1INS RAS-30MH1-EN2 1 12/14/13 10:59 AM12/14/13 10:59 AM