PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched to OFF and the unit is disconnected
from the electrical outlet.
2. Selecta location foryour humidifier,on a flat surface, about 4” away
from the wall. DO NOT place the humidifier on a finished floor or
nearfurniture, which can be damaged by moisture or water.Place on
a moisture-resistant surface.
FILLING THE WATER TANK
1. Remove the tank from the base of the humidifier and bring to the
faucet. Turn the tank upside down and twist off the tank cap by
turning counter clockwise. Fill tank with cool, fresh tap water. DO
NOT fill with warm water as this may cause leaking.
Replace the cap on tank FIRMLY.
2. When full, carry tank to the humidifier and place onto the base. The
tank holds 1.2 gallons of water and the base holds 1/3 gallons of
water. The tank will immediately begin to empty into base.
3. Plug the power cord into a 120V AC electrical outlet.
Your humidifier is equipped with a technologically advanced AccuSet Plus ™
digitalHumidistat. Youcanset the humidifier to run continuously in manual
modeor set the AccuSet Plus™ Digital Humidistatto your desired humidity
setting. The AccuSet Plus™ Digital Humidistat will automatically turn the
humidifier ON or OFF, depending on the preset comfort level. The comfort
level ranges between 35% and 65% relative humidity.
Manual Mode Instructions:
1. Plug the humidifier into a 120V AC electrical outlet.
2. The display will show the current room humidity.
3. To start the unit, push the MODE/OFF button once for the HIGH (3)
manual setting.
4. Press the button again for the MEDIUM (2) manual setting and again
for LOW (1). After the selection is made, the display will return to
show the current room humidity.
5. To stop the unit, press and hold the button for two seconds, or keep
pressing the button until the display reads OFF.
AccuSet Plus™ HUMIDISTAT INSTRUCTIONS (see Figure 1)
To take advantage of the AccuSet Plus™ Digital Humidistat, press the
MODE/OFF button until the speed is set in either the Auto HIGH (A3),
AutoMEDIUM(A2) or Auto LOW (A1)setting.Thenadjustthesethumidity
by using the up and down buttons. Humidity will increase in increments
of 5%. When the humidity level is set, the display will return to show the
currentroomhumidity. Whenthe room humidity level rises above the set
humidity, the humidifier will stop. When the humidity level drops below
the set humidity, the humidifier will turn on automatically.
NOTE: Allowup to 30 minutes for the filterto fully absorbwater and for
the unit to produce moisture.
NOTE: The AccuSet Plus™ Humidifier has memory. This means that
whenyouturntheunit back on, it will beatthelastsetting the humidifier
was set at.
Ifyou do notplan to use the humidifier for two or more days, makesure
anyresidual water is drainedfrom the water tank, base and wickfilter to
prevent algae or bacteria growth.
USING THE PROGRAMMABLE TIMER
AccuSetPlus™ allows the user to program thehumidifier to comeon at a
preset time, or turn off after a set amount of time.
Setting the Off Timer:
1. Select the Mode and or humidity you wish the humidifier to run in.
2. While the humidifier is running, press and hold the up and down
buttons simultaneously for 2 seconds. The display will flash “00”.
3. Bypressing the up anddown buttons, program thehumidifier to turn
off up to 16 hours later in increments of 1 hour.
4. After setting the timer, the display will return to show the current
room humidity. The timer light will illuminate to show that the timer
is activated.
5. Afterthepredetermined length of time has passed, the humidifierwill
automatically shut off.
Setting the On Timer:
1. While the humidifier is off, press and hold the up and down buttons
simultaneously for 2 seconds.
2. Bypressing the up anddown buttons, program thehumidifier to turn
on up to 16 hours in advance in increments of 1 hour.
3. After the preset length of time has passed, the humidifier will
automatically turn on Auto Mode HI at 45% for a preset time of 2
hours.
AccuSetPlus™ REMOTE INSTRUCTIONS (For HM7305RC-U only)
1. Insert 2 AAA batteries into back of remote control.
2. Press the Mode/Off button on remote to begin operation.
3. Use the remote to control the same features as the base unit.
NOTE: The timer function can only be activated on the base unit. It
cannot be activated via the remote control.
NOTE: Do not mix new and old batteries. Do not mix alkaline, standard
(carbon-zine), or rechargeable (nickel-cadmium) batteries.
PLEASE READ AND SAVE THESE
IMPORTANT SAFETY INSTRUCTIONS CLEANING/MAINTENANCE
REPLACING/STORAGE THE FILTER
FEATURES - OPERATIONS
When using electrical appliances, basic safety precautions should
alwaysbefollowedtoreducethe risk of fire, electricshock,andinjury
to persons, including the following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance directly into a
120V AC electrical outlet.
3. Keep the cord out of heavy traffic areas. To avoid fire hazard,
NEVER put the cord under rugs or near heat registers.
4. DO NOT place humidifier near heat sources such as stoves,
radiators, and heaters. DO locate your humidifier on an inside
wallnear an electrical outlet. Thehumidifier should beat least 4”
away from the wall for best results.
5. NEVERplace humidifier in an areawhere itis accessible to children.
NEVER use humidifier in a closed room, particularly where a child
may be sleeping, resting, or playing (a closed room may result in
excessive humidity).
6. WARNING: Do not attempt to refill humidifier without first
unplugging the unit from its electrical outlet. Failure to heed this
warning may cause personal injury. Be sure to unplug the unit by
pulling on the plug and not the cord.
7. Neverplaceanything over moisture outletwhenthe unit is running.
8. NEVER drop or insert any object into any openings.
9. DONOToperate any appliance withadamaged cord or plug,after
the appliance malfunctions, or if it has been dropped or damaged
in any manner. Return appliance to manufacturer for
examination, electrical or mechanical adjustment, or repair.
10.Use appliance only for intended household use as described in this
manual. Any other use not recommended by the manufacturer
may cause fire, electric shock, or injury to persons. The use of
attachments not recommended or sold by the manufacturer may
cause hazards.
11.DO NOT use outdoors.
12.Always place humidifier ona firm, flat, level surface. Awaterproof
mat or pad is recommended for use under the humidifier. NEVER
place it on a rug or carpet, or on a finished floor that may be
damaged by exposure to water or moisture.
13.DO NOTallowtheMoistureOutlettodirectlyface the wall. Moisture
could cause damage, particularly to wall paper.
14.Humidifier should be unplugged when not in use.
15.NEVER tilt, move, or attempt to empty unit while it is operating.
Shut off and unplug before removing the water tank and moving
the unit.
16.This humidifier requires daily and weekly maintenance to operate
appropriately. Referto daily and weeklycleaning procedures. Use
only cleaners and additives recommended by the manufacturer.
17.NEVER use detergents, gasoline, glass cleaner, furniture polish, paint
thinner, or other household solvents to clean any part of the
humidifier.
18.Excessive humidity in a room can cause water condensation on
windows and some furniture. If this happens, turn the
humidifier OFF.
19.Do not use humidifier in an area where humidity level is in excess
of 50%. Use a hygrometer, available at your local retailer or
through the manufacturer, to measure the humidity.
20.DO NOT attempt to repair or adjust any electrical or mechanical
functions on this unit. Doing so will void your warranty. The
inside of the unit contains no user serviceable parts. All servicing
should be performed by qualified personnel only.
21.Never place housing under water flow or immerse in liquids.
22.Do not plug in the cord with wet hands: electric shock could result.
23.Do not pour water in any openings other than the water tank.
24.To prevent damage to surfaces, do not place humidifier under
overhanging surfaces.
25.NEVER operate unit without water in the tank.
26.Do not move unit after it has been used until unit cools completely.
27.Use both hands when carrying full tank of water.
PLEASE READ AND SAVE
THESE IMPORTANT
SAFETY INSTRUCTIONS
Consumer Safety Information
Note: This is an electrical appliance and requires attention when in use.
Note: Ifmoisture forms on thewallsor windows of theroom, turn off the
humidifier. The room already has plenty of humidity and additional
moisture may cause damage.
Note: DO NOT block air inlet or outlet.
Cord and Plug Installation Safety Instructions
The length of cord used on this appliance was selected to reduce the
hazards of becoming tangled in, or tripping over a longer cord. If a
longer cord is necessary an approved extension cord may be used. The
electricalratingoftheextensioncordmustbeequaltoorgreaterthanthe
rating of the humidifier. Care must be taken to arrange the extension
cord so that it will not drape over the countertop or tabletop where it can
be pulled on by children or accidentally tripped over.
Your Holmes Cool Mist humidifier draws dry air through the rear air
intake grill area. This air is then passed through 3 moisture laden wick
filters,which retains the minerals and deposits in the water. Theresulting
moist air is directed back into the room from the top air grill.
NOTE: This humidification system provides a cool, invisible moisture
output. It is normal not to see the mist.
NOTE: A humidity level below 20% can be unhealthy and uncomfortable.
The recommended humidity level is between 40%-50%.
REPLACING THE FILTERS
Throughnormaluse, waterborne minerals and sediment becometrappedin
thewick filters. The harder yourwater,the greater theamountof minerals
inthewater,and the moreoftenYouwill beable to monitor thelifeof your
filters in your humidifier.
Youwill be able tomonitorthe life
ofthe filters in your humidifier by
checkingtheFilterCheck® Indicator.
When the unit is off, the
FilterCheck®Indicator will read in
theOFF position. After 60 minutes
of use, FilterCheck®Indicator will
movefromthe OFF position and indicate yourfilterscondition. New filters
will register in the blue section reading Good filter. After frequent use of
your humidifier, the FilterCheck®Indicator will let you know when the
filters need to be changed, see Figure 2.
When the needle is in the grey/black (CHANGE) section, this means the
properamountof moisture is not getting intoyourairduetotheexcessive
minerals and sediment that have become trapped on your filters. At this
point, you should replace your filters. It is important to change your
filters as indicated to obtain stated performance level.
To replace the filter, follow the steps below:
1. Turn the unit off and disconnect from the electrical outlet.
2. Remove the tank and main housing to access the base.
3. Remove the wick holder from the base of the humidifier.
4. Remove each individual wick and discard. Do not remove rivet,
replacement wicks come equipped with rivets for easy replacement.
5. Follow the weekly cleaning instructions.
6. Insertnew filters into eachsection of the wickholder making sure the
rivet attaches to the wick holder securely.
7. Do not use wicks without rivets as this will not produce the units
intended output.
8. Replace the wick holder into the base and replace main housing and
then tank.
9. Repeat Operating Instructions.
It will take about 30 minutes for the humidifier to reach maximum output.
You can purchase replacement filters (Model HWF100) by calling 1-800-
5-HOLMES or by visiting www.holmesproducts.com.
Humidifiersprovide comfort by addingmoisture to dry, heated indoor air.
To benefit most from the humidifier and avoid product misuse, follow all
instructions carefully. Please note that this is an electrical appliance and
requires attention when in use.
In addition, if you do not follow the recommended care and maintenance
guidelines, micro-organisms may be able to grow in the water within the
watertank. Youmust routinely follow thecleaningproceduresthat follow
in order to ensure proper, efficient operation of your humidifier. Proper
maintenance and cleaning is essential tothe continued performance of your
unit and the avoidance of algae or bacteria build-up.
DAILY MAINTENANCE
1. Be sure the unit is OFF and is disconnected from the electrical outlet.
2. Removethehousing andthetankfromthehumidifierandplacein sink
or tub.
3. Carry the base of the unit to the sink, remove the wick holder and
wicks, place in sink, drain any remaining water and rinse thoroughly
toremoveanysediment or dirt. Wipe clean, anddry with a clean cloth
or paper towel. NOTE: the base and wick holder are dishwasher safe
TOP RACK ONLY.
4. Drainthe waterfrom thetank intothe sinkand rinsetank thoroughly.
Wipe clean, and dry with a clean cloth or paper towel.
5. Put filters back in wick holder, replace on base, replace the housing,
then refill tank with cool tap water as instructed earlier in the Filling
Instructions. DO NOT overfill.
6. Follow Operating Instructions.
WEEKLY MAINTENANCE
To Remove Scale:
1. Repeat steps 1-4 above.
2. Clean the base by partially filling the base with one 8-oz cups of
undilutedwhitevinegar,orby using CleanseClean®(Model S1710) by
the manufacturer. Leave this solution in the base for 20 minutes,
whilecleaningthe all interior surfaces with asoftbrush. Remove base
scale by wiping the base with a cloth dampened with undiluted white
vinegar.
3. Rinse with clean warm water to remove the cleaning solution before
disinfecting the tank.
To Disinfect Humidifier Base and Tank:
1. Fill humidifier base with
1/4
gallon of water and
1/2
teaspoon of
chlorine bleach.
2. Fill the tank
1/2
full with water and
1/2
teaspoon of chlorine bleach.
3. Let the solution stand for 20 minutes, swishing every few minutes.
Wet all surfaces.
4. Carefully empty the base and tank after 20 minutes, and rinse with
wateruntilyoucannotdetect any bleach smell. Dry withacleancloth
or paper towel.
5. Check the FilterCheck®Indicator to see if it is time to replace the
filters. Depending on water hardness in your area, it may be
necessary to change the filter every 1-2 months. Re-insert the wick
filters into the wick holder.
6. Refill the water tank as directed with cool tap water, replace the
humidifier housing, and turn the unit on.
When not using your humidifier for an extended period of time:
1. Dispose of the filters. DO NOT leave in unit.
2. Clean, rinse and thoroughly dry the humidifier as directed in weekly
maintenance. DO NOT leave any water in the unit when storing.
Leaving water in the unit may render the unit inoperable for the
following season.
3. Placethe humidifier in the originalcarton and store in a cool, dryplace.
4. Order your replacement filter for next year’s use.
THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC
(Alternating Current) PLUG (a plug having one blade wider
than the other). This plug will fit into the power outlet only
one way. If the plug does not fit fully into the outlet, reverse
the plug. If it still does not fit, contact qualified personnel to
install the proper outlet.
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS
POLARIZED PLUG IN ANY WAY
CLEANING AND MAINTENANCE INSTRUCTIONS
OPERATING INSTRUCTIONS
STORAGE INSTRUCTIONS
HOW COOL MIST WORKS
Figure 2
Figure 1