3
GB
DATA PLATE
Dimensions
width cm 43.5
height cm 32
depth cm 41.5
Volume lt. 58
Dimensions of
models with
removable racks
width cm 37.5
height cm 32
depth cm 41.5
Volume of models
with removable
racks
lt. 50
Electrical
connections
voltage: 230-240V ~ 50/60 Hz or
50Hz (see data plate)
maximum power absorbed
2800-3000W
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens.
Norm EN 50304
Energy consumption for Natural
convection – heating mode:
Traditional mode
Declared energy consumption for
Forced convection Class – heating
mode: Baking
This appliance conforms to the
following European Economic
Community directives:
-2006/95/EEC of 12/12/06 (Low
Voltage) and subsequent
amendments;
- 89/336/EEC of 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments;
- 93/68/EEC of 22/07/93 and
subsequent amendments.
- 2002/96/EC
Electrical Connection
Electrical connection
The electrical connection to the mains m st be made
on the appliance. The power voltage and freq ency
are as indicated on the rating plate.
! THIS APPLIANCE MUST BE EARTHED.
Connecting the power supply cable
To open the terminal board:
Using a screwdriver, press on the tabs sit ated on
each side of the terminal board cover.
P ll open the terminal board cover.
To connect the power s pply cable, proceed as
follows:
_Unscrew the cable clamp screw and the contact
screws L-N-$.
Fasten the wires beneath the screwheads sing the
following colo r scheme: Blue (N) Brown (L)
Yellow-Green$
Fasten the power s pply cable in the
corresponding cable clamp and close the cover.
Electrical Connection:
Voltage Freq ency: 230
V-1+N 50Hz
F se Section: 16A
S pply cable: 3x1.5mm2
Yo can connect yo r oven to the system means of a
terminal board. Refer to above information for the
minimal cable sections and the calibration of the
protective elements according to the connection.
If the appliance is installed with a junction box, an
omnipolar circuit breaker - with a minim m contact
opening of 3mm - sho ld be installed between the
appliance and the mains.
Power cable supply connection to the electrical
mains:
We recommend yo se a power s pply cable which
is long eno gh to allow yo to take the oven o t of its
recess in the event of maintenance operations (only
se HAR - H 05 - RRF q ality cables fitted with a pl g
conforming to the reg lations in force.
The plug must be accessible at all times.
Unplug the appliance before all operations, even
when replacing the oven lamp.
Using the appliance without correct earthing is
highly dangerous.
! After connecting the appliance to the flexible
cable, tighten all the screws on the terminal board.