Content
s
Section 1 Safety Information…………......3
Section 2 General Information………....4-8
2.1 System Components
2.2 Specifications
2.3 Prepping for the Installation
2.4 Installation
Section 3 Maintenance& WinterStorage...9
Section 4 Troubleshooting……………….10
Section 5 After-Sales Service…………...11
Our Commitment……...…………………....11
Version No.20180101
HQUA Technical Support Team At TX

Safety Information
3
Section 1 Safety Information
Before starting the installation job, it’s very important to read the entire instructions below.
Make sure that you understand these in order to avoid any potential hazards. Failure to
do so may result in serious personal injury or damage to the equipment.
Electric Shock
• To reduce the risk of electric shock, connect only to a properly grounded, grounding-type
outlet. If in doubt, have the outlet checked by a qualified electrician.
• This unit is to be used in a circuit protected by a ground fault circuit interrupter (GFCI).
• Disconnect the unit from the power source before anyone enter into water area.
• This fountain has not been investigated for use in swimming pool areas.
Safety Precautions
• NEVER run the unit out of the water. The heat would ruin the motor in a short time and
create a dangerous situation for the operator.
• NEVER lift or drag the fountain by the power cord. Fixed rope is provided for lifting and
carrying.
• If installing the fountain from a boat or raft ALWAYS wear a Coast Guard-approved life
jacket.
• ALWAYS use a qualified electrician to install a power source next to your pond
This product must be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electric shock by providing an escape wire for the electric
current. This product is equipped with a cord having a grounding wire with an appropriate
grounding plug. The plug must be plugged into an outlet that is properly installed and
grounded.

General Information
4
Section 2 General Information
2.1 System Components
① Floating Fountain Pump HQUA-FS01P
1. Easy to Install
2. Asynchronous Water Cooled Motor, Stainless Steel Shaft Bearing.
3. Energy Efficient, Fully Sealed Motor. 5.8A, 620W 100-120V,
4. Stainless Steel Suction Screen & Body.
5. Operates in as least 40” of Water Depth.
6. Provides aeration for ponds up to 1/4 acre, 6’ deep. Larger ponds will require multiple
fountains or Our Aeration System, SWA20 PAS10 PAS20.
② Float Plate HQUA-FS01F
1. Durable HDPE materials made with excellent weather resistance.
2. Great air tightness, providing enough buoyancy to support the pump body
③ Electric Parts
1. 100’ Weatherproof Power Cord. 4-pin. Durable and Reliable.
2. Weatherproof connection electric box. Capacitor Contained.
3. Standard 3-pin plug.
①
②
③

General Information
5
Other Accessories
1. Special nozzle design for spraying. Crown Pattern. 3 Stage beautiful fountain.
2. Different stainless steel accessories for assembling.
3. Stakes, cable, carabiners, cable clamps for mooring to secure the fountain.
2.2 Specification
Item Name
HP
Max
Amps
Volts
Power
Cord
Max Pond
Size
Minimum
Depth
FS01 1/2 5.8 110V
100’ 1/2 Acres 40”
Pattern Size: 7’×30’
2.3 Prepping for the installation:
Tool Required:
• Hammer • Boat/Raft/Swimsuit • 3/16” Allen Wrench
• Shovel • Phillips screwdriver • Coast Guard-approved life jacket
①
②
③

General Information
6
1. Ensure you have a close power for the connection. If you don’t, we always
recommend to hire a licensed electrician to properly run power down to this unit.
2. Mount the Connection Box in a fixed position next to the power source.
3. Ensure you have a good spot to moor the stake.
2.4 Installation
1. We have already assembled the two
blocks for you. Please refer that and
finish the whole assembling of the
float plate.
2. Use the two carabiners to fix the
rope on the float plate
Fig. 1
Fig. 2

General Information
7
3. a, Lay the float plate on the ground with the HQUA logo facing up.
b, Place the fountain pump into the center of the float. Make sure the wire is covered
by the float.
c, Place all the accessories according to the order in Fig. 3. First is the “puzzle plate”,
and the gasket, thread fastener, the nozzle, the last is another fastener.
d, Lift the float straight up and ensure the cord is under the float. Put it into the water
edge.
4. Fix the other side of the rope with
the stakes by the cable clamps.
And fix the stake. You could adjust
the cable clamps later to moor the
float later.
Fig. 3
Fig. 4

General Information
8
5. Put the whole fountain assembly into the water and adjust rope by the carabiners or
use a boat to help the fountain stay at your ideal position in your pond.
Grab the ropes when you adjust the cable clamps, loose one side and through the hole of
the stake. Loose the other side of the cable clamps and drag it until you think the remain
length is enough. Do all the moves roll over again to fix it on the stake.
The wires and two cables would work as a triangle.
Connect the power supply with the outlet timer and you are ready to go.

Maintenance & Winter Storage
9
Section 3 Maintenance & Winter Storage
Maintenance
• Always unplug system before performing any maintenance or troubleshooting.
• Always unplug system and refer servicing to a qualified electrician when: cord is
damaged or frayed, compressor, power control, compressor fan, or other electrical
components are producing unusual noises or odors.
• Periodically clean fountain intake screen of debris, algae and/or aquatic weeds.
Check that monthly to extend the lifetime of the pump.
Winter Removal & Storage
1. Remove the fountain from the pond before ice begins to form.
2. Clean or power wash any debris on the unit before storing.
Spring Installation Inspection
Before re-installing the fountain and lights in the spring, check the condition of the power
cord.

Troubleshooting
10
Section 4 Troubleshooting
IF THE PUMP IS NOT WORKING:
Check Possible Reason Solution
Check for power. Pump is not receiving power. Check the power outlet or electrical
cord.
GFCI circuit tripped. Damage to electrical cord or low
voltage from power supply. Contact a qualified electrician for
professional assistance.
GFCI circuit not
tripped. GFCI malfunction.
Outlet timer is not
working. Not working hours or defective. Test or replace a new one.
Not enough water in
the pond.
The water depth should not lower than
40”.
Stop the unit until you get enough water
depth.
Plugged. Intake Plugged or Fountain impeller
stuck.
Clean the intake. Contact HQUA if it still
cannot be fixed.
IF THE SPRAYING IS VERY SMALL:
ISSUE Solution
Intake Plugged or Fountain impeller stuck. Clean the intake. Contact HQUA if it still cannot be fixed.
Not enough water in the pond. The water depth should not lower than 40”.
Debris caught in nozzle hole or defective. Remove nozzle, clean, replace
IF THE PUMP STARTS AND STOPS FREQUENTLY:
ISSUE Solution
Intake Plugged or Fountain impeller stuck. Clean the intake. Contact HQUA if it still cannot be fixed.
Not enough water in the pond. The water depth should not lower than 40”.
IF SPRAYING RAISE AND LOWER:
ISSUE Solution
Not enough water in the pond. The water depth should not lower than 40”.
The water line is too high. Check fountain float for water, replace if any
IF THE PUMP STARTS AND STOPS FREQUENTLY:
ISSUE Solution
Intake Plugged or Fountain impeller stuck. Clean the intake. Contact HQUA if it still cannot be fixed.
Not enough water in the pond. The water depth should not lower than 40”.

After-Sales Service
11
Section 5 After-Sales Service
If you need any support, or have questions about the system, please
contact our Technical Support team via [email protected] and we will be
glad to assist you. We sincerely hope that you enjoy the benefits of clean
and safe drinking water after the installation of HQUA disinfection system.
Our Commitment
Two-Years Limited Warranty for HQUA FS01 Floating Fountain
HQUA warrants that the FS01 Floating Fountain is free from defects of material and
workmanship for a period of 2 years from the date of purchase. During this period, HQUA
will repair or replace, at its option, any defective HQUA UV chamber. Please return the
defective part to your dealer for claim.
Additional Warranty:
Five-Years Limited Warranty for HQUA-FS01F Float.
During this period, HQUA will repair or replace, at its option, any defective HQUA UV
chamber. Please return the defective part to your dealer for claim.
..…..…………….….………….………………The End………………………………………………..
Table of contents
Other HQUA Outdoor Fountain manuals
Popular Outdoor Fountain manuals by other brands

Halsey Taylor
Halsey Taylor HRFS-FR owner's manual

SUNRAY
SUNRAY 402006 instruction manual

APETDOLA
APETDOLA FS10 PRO instructions

Westfalia
Westfalia 81 28 82 instruction manual

Elkay
Elkay FLEXI-GUARD EIOA4 1E Series Installation, care & use manual

Profi-pumpe
Profi-pumpe STEIN-GEZWITSCHER operating instructions

Kelkay
Kelkay Easy Fountain Rugged Oak instructions

Sunnydaze Decor
Sunnydaze Decor HDC-260 manual

Bradley
Bradley Terreon TDB3103 Installation

Profi-pumpe
Profi-pumpe GB02178-4 operating instructions

Campania International
Campania International Ripple FT-372 Assembly instructions

Campania International
Campania International FT-199 Lucas Fountain Qquick Start Guide