Huawei CX600-8 Guide

HUAWEI CX600-8/16/X3/X8/X16 Metro Service
Platform
V600R007C00
Hardware Description
Issue 03
Date 2013-11-30
HUAWEI TECHNOLOGIES CO., LTD.

Copyright © Huawei Technologies Co., Ltd. 2013. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: [email protected]
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
i

About This Document
Purpose
This document describes the contents, related version, intended audience, conventions, and
change history of the HUAWEI CX600 Metro Services Platform Hardware Description.
Related Versions
The following table lists the product versions related to this document.
Product Name Version
HUAWEI CX600 Metro
Services Platform
V600R007C00
Intended Audience
The intended audience of this document are:
lCommissioning Engineers
lData Configuration Engineers
lNetwork Monitoring Engineers
lSystem Maintenance Engineers
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Description
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description About This Document
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
ii

Symbol Description
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
Indicates a potentially hazardous situation which, if not
avoided, could result in equipment damage, data loss,
performance deterioration, or unanticipated results.
NOTICE is used to address practices not related to personal
injury.
Calls attention to important information, best practices and
tips.
NOTE is used to address information not related to personal
injury, equipment damage, and environment deterioration.
Update History
Updates between document versions are cumulative. Therefore, the latest document version
contains all updates made to previous versions.
Changes in Issue 03 (2013-11-30)
The third commercial release.
Changes in Issue 02 (2013-09-30)
The second commercial release.
Changes in Issue 01 (2013-06-15)
Initial commercial release. This document has the following updates compare with
V600R006C00SPC300.
Change Types Board Name Description
New CR5DLPUFF070 Flexible Card Line
Processing Unit
(LPUF-240)
New CR5DLPUFF07B Flexible Card Line
Processing Unit
(LPUF-240-B)
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description About This Document
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
iii

Change Types Board Name Description
New CR5DLPUFF07B Flexible Card Line
Processing Unit
(LPUF-240-E)
New CR5D00E1NC74 8.8.1 1-Port 100GBase-CFP
Flexible Card A(P240-A)
New CR5D00LBXF71 8.8.2 12-Port 10GBase
LAN/WAN-SFP+ Flexible
Card A(P240-A)
New CR5D00E2NC70 8.9.1 2-Port 100GBase-CFP
Integrated Line Processing
Unit (LPUI-240)
New CR5D00LFXF70 8.9.2 24-Port 10GBase
LAN/WAN-SFP+
Integrated Line Processing
New CR5DE2NLBX70 8.9.3 1-Port 100GBase-CFP
+ 12-Port 10GBase LAN/
WAN-SFP+ Integrated
Line Processing Unit
(LPUI-240)
New CR5D00E2NC73 8.9.4 2-Port 100GBase
LAN-CFP Integrated Line
Processing Unit B
(LPUI-240-B)
New CR5D00LFXF73 8.9.5 24-Port 10GBase
LAN/WAN-SFP+
Integrated Line Processing
Unit B(LPUI-240-B)
New CR5DE2NLBX73 8.9.6 1-Port 100GBase-CFP
+ 12-Port 10GBase LAN/
WAN-SFP+ Integrated
Line Processing Unit B
(LPUI-240-B)
New CR5DLPUFB070 Flexible Card Line
Processing Unit
(LPUF-120)
New CR5DLPUFB07B Flexible Card Line
Processing Unit
(LPUF-120-B)
New CR5DLPUFB07E Flexible Card Line
Processing Unit
(LPUF-120-E)
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description About This Document
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
iv

Change Types Board Name Description
New CR5D0L6XFA70 8.10.1 6-Port 10GBase
LAN/WAN-SFP+ Flexible
Card A(P120-A)
New CR5D00E1NC75 8.10.2 1-Port 100GBase-
CFP Flexible Card A(P120-
A)
New CR5D00LBXF72 8.10.3 12-Port 10GBase
LAN/WAN-SFP+ Flexible
Card A(P120-A)
New CR5D0LBXFA70 8.11.1 12-Port 10GBase
LAN/WAN-SFP+
Integrated Line Processing
Unit(LPUI-120)
New CR5D0E2MCA70 8.11.2 2-Port 40GBase
LAN-CFP Integrated Line
Processing Unit(LPUI-120)
New CR5D00E1NC76 8.11.3 1-Port 100GBase-
CFP Integrated Line
Processing Unit (LPUI-120)
New CR5D0LBXFA7B 8.11.4 12-Port 10GBase
LAN/WAN-SFP+
Integrated Line Processing
Unit B(LPUI-120-B)
New CR5D0E2MCA7B 8.11.5 2-Port 40GBase
LAN-CFP Integrated Line
Processing Unit B
(LPUI-120-B)
New CR5D00E1NC7B 8.11.6 1-Port 100GBase-
CFP Integrated Line
Processing Unit B
(LPUI-120-B)
New CR5DLAXFAJ7E 8.12.1 10-Port 10GBase
LAN/WAN-SFP+
Integrated Line Processing
Unit E(LPUI-102-E)
New CR5D0L5XFE71 8.16.5 5-Port 10GBase
LAN/WAN-SFP+ Flexible
Card E(P101-E)
New CR5D0EFGFE70 8.19.4 24-Port 1000Base-X-
SFP Flexible Card E(P51-
E)
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description About This Document
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
v

Change Types Board Name Description
New CR5D0L5XFE70 8.19.5 5-Port 10GBase
LAN/WAN-SFP+ Flexible
Card E(P51-E, Occupy two
slots)
New CR5D0L2XFE70 8.19.6 2-Port 10GBase
LAN/WAN-SFP+ Flexible
Card E(P51-E)
New CR5D0EEGEA70 8.19.7 20-Port
10/100/1000Base-RJ45
Flexible Card(P51-A)
New CR5DL3XEFG7C 8.20.5 3-Port 10GBase
LAN/WAN-SFP+ + 24-Port
100/1000Base-X-SFP
Integrated Line Processing
Unit (LPUI-51)
New CR5D0L5XFA7E 8.20.13 5-Port 10GBase
LAN/WAN-SFP+
Integrated Line Processing
Unit E(LPUI-51-
E,Enhanced HQos)
New CR5DL2XEFG7E 8.20.14 2-Port 10GBase
LAN/WAN-SFP+ + 24-Port
1000Base-X-SFP
Integrated Line Processing
Unit E(LPUI-51-
E,Enhanced HQos)
New CR5D00A8CF70 8.22.12 8-Port OC-3c/
STM-1c ATM-SFP Flexible
Card(P50)
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description About This Document
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
vi

Contents
About This Document.....................................................................................................................ii
1 Product Overview..........................................................................................................................1
1.1 Overview........................................................................................................................................................................2
2 Product Signal Flow Overview...................................................................................................3
2.1 General Service Process Overview.................................................................................................................................4
2.2 Signal Flow on the Control Plane...................................................................................................................................5
2.3 Signal Flow on the Data Plane.......................................................................................................................................8
2.4 Signal Flow on the Monitoring Plane...........................................................................................................................10
3 CX600-X16......................................................................................................................................12
3.1 Device Overview..........................................................................................................................................................13
3.1.1 System Overview.......................................................................................................................................................13
3.1.2 Main Components and Slot Layout...........................................................................................................................16
3.1.3 CX600-X16 Specifications........................................................................................................................................18
3.1.4 Board Specifications..................................................................................................................................................20
3.2 Power Supply System...................................................................................................................................................36
3.2.1 Architecture of the Power Supply System.................................................................................................................36
3.2.2 Distributed Architecture of the System.....................................................................................................................36
3.2.3 DC Power Supply System.........................................................................................................................................37
3.2.4 AC Power Supply System.........................................................................................................................................40
3.3 Heat Dissipation System...............................................................................................................................................43
3.3.1 System Air Channel...................................................................................................................................................43
3.3.2 Air Intake Vent..........................................................................................................................................................44
3.3.3 Fan Module................................................................................................................................................................45
3.3.4 Air Filter....................................................................................................................................................................46
3.3.5 Fan Speed Adjustment...............................................................................................................................................47
3.4 Switching Network.......................................................................................................................................................48
3.4.1 Introduction to the Switching Network.....................................................................................................................48
3.4.2 Switch Fabric Unit B.................................................................................................................................................49
3.4.3 40Gbps Switch Fabric Unit B....................................................................................................................................51
3.5 Control Plane................................................................................................................................................................53
3.5.1 Introduction to the Control Plane..............................................................................................................................53
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description Contents
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
vii

3.5.2 Main Processing Unit B4...........................................................................................................................................54
4 CX600-X8........................................................................................................................................61
4.1 Device Overview..........................................................................................................................................................62
4.1.1 System Overview.......................................................................................................................................................62
4.1.2 Components of the CX600-X8..................................................................................................................................64
4.1.3 CX600-X8 Specification...........................................................................................................................................66
4.1.4 Board Specifications..................................................................................................................................................68
4.2 Power Supply System...................................................................................................................................................81
4.2.1 Architecture of the Power Supply System.................................................................................................................82
4.2.2 Distributed Architecture of the System.....................................................................................................................82
4.2.3 DC Power Supply System.........................................................................................................................................82
4.2.4 AC Power Supply System.........................................................................................................................................84
4.3 Heat Dissipation System...............................................................................................................................................88
4.3.1 System Air Channel...................................................................................................................................................88
4.3.2 Air Intake Vent..........................................................................................................................................................89
4.3.3 Fan Module................................................................................................................................................................89
4.3.4 Air Filter....................................................................................................................................................................91
4.3.5 Fan Speed Adjustment...............................................................................................................................................91
4.4 Switching Network.......................................................................................................................................................91
4.4.1 Introduction to the Switching Network.....................................................................................................................92
4.4.2 200Gbps Switch Fabric Unit C(SFUI-200-C)...........................................................................................................93
4.4.3 100Gbps Switch Fabric Unit D(SFUI-100-D)...........................................................................................................95
4.4.4 40Gbps Switch Fabric Unit C....................................................................................................................................97
4.5 Control Plane................................................................................................................................................................99
4.5.1 Introduction to the Control Plane..............................................................................................................................99
4.5.2 Switch and Route Processing Unit A7....................................................................................................................100
4.5.3 Switch and Route Processing Unit A5....................................................................................................................106
4.5.4 Switch and Route Processing Unit A4....................................................................................................................112
5 CX600-X3......................................................................................................................................119
5.1 Device Overview........................................................................................................................................................120
5.1.1 System Overview.....................................................................................................................................................120
5.1.2 Main Components and Slot Layout.........................................................................................................................121
5.1.3 CX600-X3 Specifications........................................................................................................................................123
5.1.4 Board Specifications................................................................................................................................................126
5.2 Power Supply System.................................................................................................................................................135
5.2.1 Architecture of the Power Supply System...............................................................................................................135
5.2.2 Diagram of the Power Supply System.....................................................................................................................136
5.2.3 DC Power Supply System.......................................................................................................................................136
5.2.4 AC Power Supply System.......................................................................................................................................137
5.3 Heat Dissipation System.............................................................................................................................................140
5.3.1 System Air Channel.................................................................................................................................................141
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description Contents
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
viii

5.3.2 Air Intake Vent........................................................................................................................................................142
5.3.3 Fan Module..............................................................................................................................................................142
5.3.4 Air Filter..................................................................................................................................................................143
5.3.5 Fan Speed Adjustment.............................................................................................................................................144
5.4 Control Plane..............................................................................................................................................................144
5.4.1 Introduction to the Control Plane............................................................................................................................144
5.4.2 Main Processing Unit D2(CX6D0MPUD170)........................................................................................................145
6 CX600-16 Chassis Overview....................................................................................................150
6.1 Product Overview.......................................................................................................................................................151
6.1.1 Device Structure......................................................................................................................................................151
6.1.2 CX600-16 Specifications.........................................................................................................................................154
6.1.3 Board Specifications................................................................................................................................................156
6.2 Power Supply..............................................................................................................................................................162
6.2.1 DC Power Supply Module.......................................................................................................................................162
6.2.2 AC Power Supply Module.......................................................................................................................................167
6.3 Heat Dissipation System.............................................................................................................................................169
6.3.1 Appearance of a Fan Module...................................................................................................................................170
6.3.2 Front Panel...............................................................................................................................................................171
6.3.3 Air Filter..................................................................................................................................................................172
6.3.4 Functions of the FCB...............................................................................................................................................173
6.3.5 Technical Parameters...............................................................................................................................................173
6.4 LCD Module...............................................................................................................................................................174
6.4.1 Front Panel...............................................................................................................................................................174
6.4.2 Display Mode..........................................................................................................................................................175
6.4.3 Display Contents......................................................................................................................................................176
6.4.4 Technical Parameters...............................................................................................................................................183
6.5 SFU(CR52-SFUG-40Gbps)........................................................................................................................................183
6.5.1 Overview.................................................................................................................................................................183
6.5.2 Features and Functions............................................................................................................................................184
6.5.3 Panel........................................................................................................................................................................184
6.5.4 Interface Attributes..................................................................................................................................................186
6.5.5 Technical Specifications..........................................................................................................................................186
6.6 MPU............................................................................................................................................................................186
6.6.1 Overview.................................................................................................................................................................187
6.6.2 Features and Functions............................................................................................................................................187
6.6.3 Panel........................................................................................................................................................................188
6.6.4 Interface Attributes..................................................................................................................................................192
6.6.5 Technical Specifications..........................................................................................................................................193
7 CX600-8........................................................................................................................................196
7.1 Overview....................................................................................................................................................................197
7.1.1 Device Structure......................................................................................................................................................197
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description Contents
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
ix

7.1.2 CX600-8 Specifications...........................................................................................................................................200
7.1.3 Board Specifications................................................................................................................................................202
7.2 Power Supply..............................................................................................................................................................205
7.2.1 DC Power Supply Module.......................................................................................................................................206
7.2.2 AC Power Supply Module.......................................................................................................................................209
7.3 Heat Dissipation System.............................................................................................................................................211
7.3.1 Appearance of the Fan Module...............................................................................................................................212
7.3.2 Front Panel...............................................................................................................................................................213
7.3.3 Air Filter..................................................................................................................................................................214
7.3.4 Functions of the FCB...............................................................................................................................................214
7.3.5 Technical Parameters...............................................................................................................................................215
7.4 SFU(CX61-SFUD).....................................................................................................................................................215
7.4.1 Overview.................................................................................................................................................................216
7.4.2 Features and Functions............................................................................................................................................216
7.4.3 Panel........................................................................................................................................................................216
7.4.4 Technical Specifications..........................................................................................................................................217
7.5 SRU............................................................................................................................................................................218
7.5.1 Overview.................................................................................................................................................................218
7.5.2 Features and Functions............................................................................................................................................219
7.5.3 Panel........................................................................................................................................................................220
7.5.4 Interface Attributes..................................................................................................................................................224
7.5.5 Technical Specifications..........................................................................................................................................225
8 Boards..........................................................................................................................................228
8.1 Overview....................................................................................................................................................................231
8.1.1 Board Structure........................................................................................................................................................231
8.1.2 Board and Subcard Specifications...........................................................................................................................233
8.1.3 Filler Panel...............................................................................................................................................................236
8.1.4 Rules for Numbering Slots and Interfaces...............................................................................................................237
8.2 CX600-X16 Board Specifications..............................................................................................................................241
8.3 CX600-X8 Board Specifications................................................................................................................................257
8.4 CX600-X3 Board Specifications................................................................................................................................270
8.5 CX600-16 Board Specifications.................................................................................................................................280
8.6 CX600-8 Board Specifications...................................................................................................................................286
8.7 Service Process Unit...................................................................................................................................................289
8.7.1 Versatile Service Process Unit C (SPUC)...............................................................................................................289
8.7.2 Flexible Card Versatile Service Unit 10 (VSUF-10)...............................................................................................293
8.7.3 Integrated Versatile Service Unit(VSUI-20-A).......................................................................................................295
8.7.4 Flexible Card Value-Added Service Processing Unit (VSUF-160)........................................................................298
8.7.5 Flexible Card Value-Added Service Processing Unit (VSUF-80)..........................................................................302
8.7.6 Versatile Service Flexible Card (SP160).................................................................................................................305
8.7.7 Versatile Service Flexible Card (SP80)...................................................................................................................307
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description Contents
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
x

8.8 Flexible Card Line Processing Unit(LPUF-240/LPUF-240-B/LPUF-240-E)............................................................309
8.8.1 1-Port 100GBase-CFP Flexible Card A(P240-A)...................................................................................................311
8.8.2 12-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P240-A) .............................................................................314
8.9 Integrated Line Processing Unit(LPUI-240)..............................................................................................................317
8.9.1 2-Port 100GBase-CFP Integrated Line Processing Unit (LPUI-240).....................................................................317
8.9.2 24-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing............................................................................320
8.9.3 1-Port 100GBase-CFP + 12-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit (LPUI-240).......324
8.9.4 2-Port 100GBase LAN-CFP Integrated Line Processing Unit B(LPUI-240-B).....................................................328
8.9.5 24-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit B(LPUI-240-B).........................................331
8.9.6 1-Port 100GBase-CFP + 12-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit B(LPUI-240-B)
..........................................................................................................................................................................................334
8.10 Flexible Card Line Processing Unit(LPUF-120/LPUF-120-B/LPUF-120-E)..........................................................338
8.10.1 6-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P120-A)..............................................................................341
8.10.2 1-Port 100GBase-CFP Flexible Card A(P120-A).................................................................................................344
8.10.3 12-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P120-A)............................................................................347
8.10.4 24-Port 100/1000Base-X-SFP Flexible Card A(P101-A).....................................................................................350
8.10.5 5-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P101-A)..............................................................................353
8.10.6 1-Port 40GBase LAN-CFP Flexible Card A(P101-A)..........................................................................................356
8.10.7 5-Port 10GBase LAN/WAN-SFP+ Flexible Card E(P101-E)..............................................................................359
8.10.8 24-Port 1000Base-X-SFP Flexible Card E(P51-E)...............................................................................................362
8.11 Integrated Line Processing Unit(LPUI-120)............................................................................................................365
8.11.1 12-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit(LPUI-120)...............................................365
8.11.2 2-Port 40GBase LAN-CFP Integrated Line Processing Unit(LPUI-120).............................................................369
8.11.3 1-Port 100GBase-CFP Integrated Line Processing Unit (LPUI-120)...................................................................372
8.11.4 12-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit B(LPUI-120-B).......................................375
8.11.5 2-Port 40GBase LAN-CFP Integrated Line Processing Unit B(LPUI-120-B).....................................................379
8.11.6 1-Port 100GBase-CFP Integrated Line Processing Unit B (LPUI-120-B)............................................................382
8.12 Integrated Line Processing Unit(LPUI-102)............................................................................................................385
8.12.1 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit E(LPUI-102-E).......................................386
8.13 Flexible Card Line Processing Unit(LPUF-100,four slots)......................................................................................389
8.13.1 5-Port 10GBase LAN/WAN-XFP Flexible Card A(P100-A,Supporting 1588v2,Occupy two sub-slots)............391
8.13.2 48-Port 100/1000Base-X-CSFP Flexible Card(P100,Occupy two sub-slots).......................................................395
8.13.3 24-Port 100/1000Base-SFP Flexible Card(P100,Occupy two sub-slots)..............................................................399
8.13.4 1-Port OC-768c/STM-256c POS-2KM-LC Flexible Card(P100,Occupy two sub-slots).....................................402
8.13.5 2-Port OC-192c/STM-64c POS-XFP Flexible Card (P101-A,Occupy one sub-slots)..........................................405
8.14 Integrated Line Processing Unit(LPUI-100)............................................................................................................409
8.14.1 10-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-100,Supporting 1588v2)...............409
8.14.2 16-Port 10GBase LAN-SFP+ Integrated Line Processing Unit(LPUI-100).........................................................413
8.14.3 1-Port 100GBase-CFP Integrated Line Process Unit(LPUI-100).........................................................................417
8.15 Line Processing Unit S (LPUS-100)........................................................................................................................420
8.15.1 10-Port 10GBase LAN/WAN-XFP Line Processing Unit S(LPUS-100).............................................................420
8.15.2 16-Port 10GBase LAN-SFP+ Line Processing Unit S(LPUS-100)......................................................................425
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description Contents
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
xi

8.15.3 1-Port 100GBase-CFP Line Processing Unit S (LPUS-100)................................................................................428
8.16 Flexible Card Line Processing Unit (LPUF-101/LPUF-101-B)...............................................................................432
8.16.1 5-Port 10GBase LAN/WAN-XFP Flexible Card A(P100-A,Supporting 1588v2,Occupy two sub-slots)............434
8.16.2 24-Port 100/1000Base-X-SFP Flexible Card A(P101-A).....................................................................................438
8.16.3 5-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P101-A)..............................................................................441
8.16.4 1-Port 40GBase LAN-CFP Flexible Card A(P101-A)..........................................................................................444
8.16.5 5-Port 10GBase LAN/WAN-SFP+ Flexible Card E(P101-E)..............................................................................447
8.16.6 24-Port 1000Base-X-SFP Flexible Card E(P51-E)...............................................................................................450
8.17 Integrated Line Processing Unit (LPUI-101)...........................................................................................................453
8.17.1 2-Port 40GBase LAN-CFP Integrated Line Processing Unit (LPUI-101)............................................................453
8.17.2 1-Port 100GBase-CFP Integrated Line Processing Unit (LPUI-101)...................................................................456
8.17.3 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit (LPUI-101)..............................................460
8.17.4 2-Port 40GBase LAN-CFP Integrated Line Processing Unit B(LPUI-101-B).....................................................463
8.17.5 10-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit B(LPUI-101-B).......................................466
8.18 Line Processing Unit S(LPUS-101).........................................................................................................................469
8.18.1 2-Port 40GBase LAN-CFP Line Processing Unit S(LPUS-101)..........................................................................469
8.18.2 1-Port 100GBase-CFP Line Processing Unit S(LPUS-101).................................................................................472
8.18.3 10-Port 10GBase LAN/WAN-SFP+ Line Processing Unit S(LPUS-101)............................................................475
8.19 Flexible Card Line Processing Unit(LPUF-51/LPUF-51-B/LPUF-51-E,two sub-slots).........................................479
8.19.1 24-Port 100/1000Base-X-SFP Flexible Card A(P51-A).......................................................................................481
8.19.2 5-Port 10GBase LAN/WAN-SFP+Flexible Card A (P51-A, Occupy two sub-slots)...........................................485
8.19.3 2-Port 10GBase LAN/WAN-SFP+ Flexible Card A(P51-A)................................................................................488
8.19.4 24-Port 1000Base-X-SFP Flexible Card E(P51-E)...............................................................................................491
8.19.5 5-Port 10GBase LAN/WAN-SFP+ Flexible Card E(P51-E, Occupy two slots)...................................................494
8.19.6 2-Port 10GBase LAN/WAN-SFP+ Flexible Card E(P51-E)................................................................................497
8.19.7 20-Port 10/100/1000Base-RJ45 Flexible Card(P51-A).........................................................................................500
8.20 Integrated Line Processing Unit (LPUI-51).............................................................................................................503
8.20.1 5-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit (LPUI-51)..................................................503
8.20.2 4-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit (LPUI-51)..................................................507
8.20.3 48-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-51).........................................................510
8.20.4 2-Port 10GBase LAN/WAN-SFP+ + 24-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-51)
..........................................................................................................................................................................................513
8.20.5 3-Port 10GBase LAN/WAN-SFP+ + 24-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-51)
..........................................................................................................................................................................................518
8.20.6 5-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit B(LPUI-51-B)...........................................523
8.20.7 4-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit B(LPUI-51-B)...........................................526
8.20.8 48-Port 100/1000Base-X-SFP Integrated Line Processing Unit B(LPUI-51-B)...................................................529
8.20.9 2-Port 10GBase LAN/WAN-SFP+ + 24-Port 100/1000Base-X-SFP Integrated Line Processing Unit B(LPUI-51-
B)......................................................................................................................................................................................534
8.20.10 5-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit L(LPUI-51-L).........................................538
8.20.11 48-Port 100/1000Base-X-SFP Integrated Line Processing Unit L(LPUI-51-L).................................................541
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description Contents
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
xii

8.20.12 2-Port 10GBase LAN/WAN-SFP+ + 32-Port 100/1000Base-X-SFP Integrated Line Processing Unit L(LPUI-51-
L)......................................................................................................................................................................................545
8.20.13 5-Port 10GBase LAN/WAN-SFP+ Integrated Line Processing Unit E(LPUI-51-E,Enhanced HQos)..............550
8.20.14 2-Port 10GBase LAN/WAN-SFP+ + 24-Port 1000Base-X-SFP Integrated Line Processing Unit E(LPUI-51-
E,Enhanced HQos)...........................................................................................................................................................553
8.21 Line Processing Unit S(LPUS-51)...........................................................................................................................557
8.21.1 5-Port 10GBase LAN/WAN-SFP+ Line Processing Unit S(LPUS-51)................................................................557
8.21.2 4-Port 10GBase LAN/WAN-SFP+ Line Processing Unit S(LPUS-51)................................................................561
8.21.3 48-Port 100/1000Base-X-SFP Line Processing Unit S(LPUS-51).......................................................................564
8.21.4 2-Port 10GBase LAN/WAN-SFP+ + 24-Port 100/1000Base-X-SFP Line Processing Unit S(LPUS-51)...........567
8.22 Flexible Card Line Processing Unit(LPUF-50,four sub-slots).................................................................................572
8.22.1 24-Port Channelized E1/T1-DB100 Flexible Card...............................................................................................574
8.22.2 8-Port OC-3c/STM-1c POS-SFP Flexible Card....................................................................................................577
8.22.3 4-Port OC-48c/STM-16c POS-SFP Flexible Card................................................................................................580
8.22.4 2-Port OC-48c/STM-16c POS-SFP Flexible Card................................................................................................583
8.22.5 2-Port Channelized OC-3c/STM-1c POS-SFP Flexible Card...............................................................................586
8.22.6 8-Port OC-12c/STM-4c POS-SFP Flexible Card..................................................................................................589
8.22.7 8-Port 100/1000Base-X-SFP Flexible Card A(P10-A,Supporting 1588v2).........................................................593
8.22.8 2-Port 10GBase WAN/LAN-SFP+ Flexible Card A.............................................................................................597
8.22.9 1-Port OC-192c/STM-64c POS-XFP Flexible Card(Occupy two slots)...............................................................600
8.22.10 4-Port Channelized STM-1c POS-SFP Flexible Card.........................................................................................603
8.22.11 8-Port Channelized STM-1c POS-SFP Flexible Card.........................................................................................606
8.22.12 8-Port OC-3c/STM-1c ATM-SFP Flexible Card(P50).......................................................................................609
8.23 Flexible Card Line Processing Unit(LPUF-40-A/LPUF-40-B/LPUF-40-E,2 sub-slots).........................................612
8.23.1 20-Port 100/1000Base-X-SFP Flexible Card(P40)...............................................................................................615
8.23.2 20-Port 100/1000Base-X-SFP Flexible Card A(P40-A,Supporting 1588v2).......................................................619
8.23.3 20-Port 100/1000Base-X-SFP Flexible Card B(P40-B)........................................................................................623
8.23.4 2-Port 10GBase LAN/WAN-XFP Flexible Card(P40).........................................................................................626
8.23.5 2-Port 10GBase LAN/WAN-XFP Flexible Card A(Supporting 1588v2).............................................................629
8.23.6 2-Port 10GBase LAN/WAN-XFP Flexible Card B(P40-B)..................................................................................633
8.23.7 20-Port 1000Base-X-SFP Flexible Card E(P40-E)...............................................................................................637
8.23.8 2-Port 10GBase LAN/WAN-XFP Flexible Card E(P40-E)..................................................................................640
8.23.9 2-Port 10GBase LAN/WAN-XFP Flexible Card V(P40-V).................................................................................644
8.23.10 20-Port 10/100/1000Base-RJ45 Flexible Card(P40)...........................................................................................647
8.23.11 4-Port 10GBase LAN/WAN-XFP Flexible Card(P40,Occupy one sub-slot).....................................................650
8.24 Integrated Line Processing Unit (LPUI-40)............................................................................................................654
8.24.1 4-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit(LPUI-40)....................................................654
8.24.2 40-Port 100/1000Base-X-SFP Integrated Line Processing Unit(LPUI-40)..........................................................658
8.25 Integrated Line Processing Unit (LPUI-41).............................................................................................................662
8.25.1 8-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-41)...................................................662
8.25.2 4-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-41)...................................................666
8.25.3 48-Port 100/1000Base-X-SFP Integrated Line Processing Unit(LPUI-41)..........................................................671
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description Contents
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
xiii

8.25.4 2-Port 10GBase LAN/WAN-XFP+24-Port 100/1000Base-X-SFP Integrated Line Processing Unit(LPUI-41)
..........................................................................................................................................................................................675
8.25.5 4-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-41,Supporting 1588v2)...................680
8.25.6 40-Port 100/1000Base-X-SFP Integrated Line Processing Unit(LPUI-41,Supporting 1588v2)..........................685
8.25.7 2-Port 10GBase LAN/WAN-XFP+20-Port 100/1000Base-X-SFP Integrated Line Processing Unit
(LPUI-41,Supporting 1588v2)..........................................................................................................................................689
8.26 Line Processing Unit S(LPUS-41)...........................................................................................................................695
8.26.1 8-Port 10GBase LAN/WAN-XFP Line Processing Unit S (LPUS-41)................................................................695
8.26.2 4-Port 10GBase LAN/WAN-XFP Line Processing Unit S (LPUS-41)................................................................700
8.26.3 48-Port 100/1000Base-X-SFP Line Processing Unit S(LPUS-41).......................................................................704
8.26.4 2-Port 10GBase LAN/WAN-XFP+24-Port 100/1000Base-X-SFP Line Processing Unit S(LPUS-41)...............708
8.27 Integrated Line Processing Unit L(LPUI-21-L).......................................................................................................714
8.27.1 24-Port 100/1000Base-X-SFP Integrated Line Processing Unit L(LPUI-21-L)...................................................714
8.27.2 1-Port 10GBase LAN/WAN-SFP+ + 16-Port 100/1000Base-X-SFP Integrated Line Processing Unit L(LPUI-21-
L)......................................................................................................................................................................................718
8.28 Line Processing Unit S(LPUS-20)...........................................................................................................................722
8.28.1 4-Port 10GBase WAN/LAN-XFP Line Processing Unit S(LPUS-20).................................................................723
8.28.2 40-Port 100/1000Base-X-SFP Line Processing Unit S(LPUS-20).......................................................................726
8.28.3 40-Port 10/100/1000Base-RJ45 Line Processing Unit S.......................................................................................730
8.29 Flexible Card Line Processing Unit(LPUF-21-A/LPUF-21-B/LPUF-21-E,2 sub-slots).........................................732
8.29.1 1-Port 10GBase WAN/LAN-XFP Flexible Card..................................................................................................735
8.29.2 1-Port 10GBase WAN/LAN-XFP Flexible Card A(Supporting 1588v2).............................................................738
8.29.3 1-Port 10GBase LAN/WAN-XFP Flexible Card B(P20-B)..................................................................................742
8.29.4 1-Port 10GBase LAN/WAN-XFP Flexible Card E(P20-E)..................................................................................745
8.29.5 12-Port 100/1000Base-SFP Flexible Card............................................................................................................749
8.29.6 12-Port 100/1000Base-SFP Flexible Card A(Supporting 1588v2).......................................................................753
8.29.7 12-Port 100/1000Base-X-SFP Flexible Card B(P20-B)........................................................................................757
8.29.8 10-Port 1000Base-X-SFP Flexible Card E(P20-E)...............................................................................................761
8.29.9 12-Port 10/100/1000Base-RJ45 Flexible Card......................................................................................................764
8.29.10 1-Port OC-192c/STM-64c POS-XFP Flexible Card(Occupy two slots).............................................................766
8.29.11 4-Port 10GBase WAN/LAN-XFP Flexible Card(Occupy two sub-slots)...........................................................769
8.29.12 40-Port 10/100/1000Base-RJ45 Flexible Card(Occupy two sub-slots)..............................................................773
8.29.13 40-Port 100/1000Base-SFP Flexible Card(Occupy two sub-slots).....................................................................775
8.29.14 2-Port 10GBase LAN/WAN-XFP+20-Port 100/1000Base-X-SFP Flexible Card(P20,Occupy two sub-slots)
..........................................................................................................................................................................................779
8.30 Flexible Card Line Processing Unit (LPUF-10,four slots).......................................................................................784
8.30.1 1-Port OC-192c/STM-64c POS-XFP Flexible Card(Occupy two slots)...............................................................787
8.30.2 1-Port OC-48c/STM-16c POS-SFP Flexible Card................................................................................................790
8.30.3 2-Port OC-48c/STM-16c POS-SFP Flexible Card................................................................................................793
8.30.4 4-Port OC-48c/STM-16c POS-SFP Flexible Card................................................................................................796
8.30.5 4-Port OC-12c/STM-4c POS-SFP Flexible Card..................................................................................................799
8.30.6 8-Port OC-12c/STM-4c POS-SFP Flexible Card..................................................................................................802
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description Contents
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
xiv

8.30.7 4-Port OC-3c/STM-1c POS-SFP Flexible Card....................................................................................................805
8.30.8 8-Port OC-3c/STM-1c POS-SFP Flexible Card....................................................................................................809
8.30.9 2-Port OC-12c/STM-4c ATM-SFP Flexible Card................................................................................................812
8.30.10 4-Port OC-3c/STM-1c ATM-SFP Flexible Card................................................................................................814
8.30.11 8-Port 100/1000Base-X-SFP Flexible Card .......................................................................................................817
8.30.12 8-Port 100/1000 Base-X-SFP Flexible Card A (Supporting 1588v2).................................................................821
8.30.13 2-Port Channelized OC-3c/STM-1c POS-SFP Flexible Card.............................................................................825
8.30.14 24-Port Channelized E1/T1-DB100 Flexible Card.............................................................................................828
8.30.15 4-Port Clear Channel E3/Channelized T3-SMB Flexible Card...........................................................................832
9 Cables...........................................................................................................................................835
9.1 DC-Input Power Cable...............................................................................................................................................836
9.1.1 CX600-X16 DC-Input Power Cable........................................................................................................................836
9.1.2 CX600-X8 DC-Input Power Cable..........................................................................................................................837
9.1.3 CX600-X3 DC-Input Power Cable..........................................................................................................................839
9.1.4 CX600-8 DC-Input Power Cable............................................................................................................................840
9.2 AC-input Power Cable................................................................................................................................................841
9.2.1 CX600-X16 AC-input Power Cable........................................................................................................................841
9.2.2 CX600-X8 AC-input Power Cable..........................................................................................................................842
9.2.3 CX600-X3 AC-input Power Cable..........................................................................................................................843
9.2.4 CX600-8 AC-input Power Cable.............................................................................................................................843
9.3 Chassis and Cabinet Grounding Cable.......................................................................................................................844
9.3.1 Introduction.............................................................................................................................................................844
9.3.2 Structure...................................................................................................................................................................844
9.3.3 Technical Specifications..........................................................................................................................................844
9.4 Console Port Cable.....................................................................................................................................................844
9.4.1 Introduction.............................................................................................................................................................844
9.4.2 Structure...................................................................................................................................................................845
9.4.3 Technical Specifications..........................................................................................................................................845
9.5 Auxiliary Port Cable...................................................................................................................................................846
9.5.1 Introduction.............................................................................................................................................................846
9.5.2 Structure...................................................................................................................................................................846
9.5.3 Technical Specifications..........................................................................................................................................847
9.6 Clock Cable................................................................................................................................................................848
9.6.1 Introduction.............................................................................................................................................................848
9.6.2 Structure...................................................................................................................................................................849
9.6.3 Technical Specifications..........................................................................................................................................851
9.7 Ethernet Cable............................................................................................................................................................853
9.7.1 Introduction.............................................................................................................................................................853
9.7.2 Structure...................................................................................................................................................................853
9.7.3 Technical Specifications..........................................................................................................................................855
9.8 Optical Fiber...............................................................................................................................................................856
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description Contents
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
xv

9.8.1 Introduction.............................................................................................................................................................856
9.8.2 Optical Connectors..................................................................................................................................................856
9.8.3 Technical Specifications..........................................................................................................................................858
9.9 CE1/CT1/E3/T3 Cable...............................................................................................................................................858
9.9.1 Introduction.............................................................................................................................................................858
9.9.2 Structure...................................................................................................................................................................858
9.9.3 Technical Specifications..........................................................................................................................................860
9.10 24xE1 Cable.............................................................................................................................................................860
9.10.1 Overview...............................................................................................................................................................860
9.10.2 Structure.................................................................................................................................................................861
9.10.3 Technical Specifications........................................................................................................................................863
9.11 Serial Port Cable (RS232/RS485)............................................................................................................................864
A List of Indicators.......................................................................................................................866
A.1 Indicators of CX600-X16..........................................................................................................................................867
A.1.1 Fan Module Indicators............................................................................................................................................867
A.1.2 Power Module Indicators........................................................................................................................................867
A.1.3 MPU Indicators.......................................................................................................................................................867
A.1.4 SFU Indicators........................................................................................................................................................869
A.1.5 LPU Indicators........................................................................................................................................................869
A.2 Indicators of CX600-X8............................................................................................................................................870
A.2.1 Fan Module Indicators............................................................................................................................................870
A.2.2 Power Module Indicators........................................................................................................................................870
A.2.3 SRU Indicators........................................................................................................................................................871
A.2.4 SFU Indicators........................................................................................................................................................872
A.2.5 LPU Indicators........................................................................................................................................................872
A.3 Indicators of CX600-X3............................................................................................................................................873
A.3.1 Fan Module Indicators............................................................................................................................................873
A.3.2 Power Module Indicators........................................................................................................................................874
A.3.3 MPU Indicators.......................................................................................................................................................874
A.3.4 LPU Indicators........................................................................................................................................................875
A.4 Indicators of CX600-16.............................................................................................................................................876
A.4.1 Fan Module Indicators............................................................................................................................................876
A.4.2 Power Module Indicators........................................................................................................................................877
A.4.3 MPU Indicators.......................................................................................................................................................877
A.4.4 SFU Indicators........................................................................................................................................................878
A.4.5 LPU Indicators........................................................................................................................................................878
A.5 Indicators of CX600-8...............................................................................................................................................879
A.5.1 Fan Module Indicators............................................................................................................................................879
A.5.2 Power Module Indicators........................................................................................................................................880
A.5.3 SRU Indicators........................................................................................................................................................881
A.5.4 SFU Indicators........................................................................................................................................................881
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description Contents
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
xvi

A.5.5 LPU Indicators........................................................................................................................................................882
B List of Boards.............................................................................................................................883
B.1 Typical Configuration................................................................................................................................................884
B.2 Boards........................................................................................................................................................................884
B.3 Power Consumption and Weight...............................................................................................................................896
C List of Interface Attributes......................................................................................................907
C.1 Interface Attributes of 10Base-T/100Base-TX/1000Base-T-RJ45............................................................................909
C.2 Interface Attributes of 100Base-FX...........................................................................................................................909
C.3 Interface Attributes of 1000Base-X-SFP...................................................................................................................910
C.4 Interface Attributes of 100/1000Base-CSFP.............................................................................................................911
C.5 Interface Attributes of 10GBase LAN/WAN-XFP....................................................................................................912
C.6 Interface Attributes of 10GBase LAN-SFP+.............................................................................................................913
C.7 Interface Attributes of 40GBase-CFP........................................................................................................................914
C.8 Interface Attributes of 100GBase-CFP......................................................................................................................915
C.9 Interface Attributes of OC-3c/STM-1c cPOS-SFP....................................................................................................916
C.10 Interface Attributes of OC-3c/STM-1c POS-SFP....................................................................................................917
C.11 Interface Attributes of OC-12c/STM-4c POS-SFP..................................................................................................918
C.12 Interface Attributes of OC-48c/STM-16c POS-SFP................................................................................................919
C.13 Interface Attributes of OC-192c/STM-64c POS-XFP.............................................................................................920
C.14 Interface Attributes of OC-768c/STM-256c POS-LC.............................................................................................921
C.15 Interface Attributes of OC-3c/STM-1c ATM-SFP..................................................................................................922
C.16 Interface Attributes of OC-12c/STM-4c ATM-SFP................................................................................................923
C.17 Interface Attributes of CE1/CT1..............................................................................................................................924
C.18 Interface Attributes of E3/T3...................................................................................................................................924
D Optical Module.........................................................................................................................926
D.1 Instructions on How to Use an Optical Module........................................................................................................928
D.2 155 Mbit/s SFP/eSFP Optical Module......................................................................................................................932
D.3 622 Mbit/s eSFP Optical Module..............................................................................................................................938
D.4 1 Gbit/s Electrical Transceiver..................................................................................................................................942
D.5 1.25 Gbit/s SFP/eSFP Optical Module......................................................................................................................943
D.6 2.5 Gbit/s SFP/eSFP Optical Module........................................................................................................................954
D.7 10 Gbit/s XFP Optical Module..................................................................................................................................960
D.8 10 Gbit/s XFP CWDM Optical Module....................................................................................................................965
D.9 10 Gbit/s SFP+ Optical Module................................................................................................................................968
D.10 10 Gbit/s SFP+ CWDM Optical Module.................................................................................................................975
D.11 10 Gbps XFP DWDM Optical Module...................................................................................................................978
D.12 10 Gbps TXFP DWDM Optical Module.................................................................................................................980
D.13 BIDI Optical Module...............................................................................................................................................983
D.14 155 Mbit/s CSFP Optical Module...........................................................................................................................995
D.15 1.25 Gbit/s CSFP Optical Module...........................................................................................................................997
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description Contents
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
xvii

D.16 40 Gbit/s TRANSPONDER Optical Modules.........................................................................................................999
D.17 40 Gbit/s CFP Optical Modules.............................................................................................................................1001
D.18 100 Gbit/s CFP Optical Modules...........................................................................................................................1003
E DPD300-4-12 Power Distribution Box, Dual-Two Inputs...............................................1010
E.1 Product Description..................................................................................................................................................1011
E.2 Power Distribution Instance.....................................................................................................................................1014
E.3 Installing the Power Distribution Box into a Cabinet..............................................................................................1018
E.4 Air Breaker Maintenance.........................................................................................................................................1023
F Glossary.....................................................................................................................................1026
G Acronyms and Abbreviations..............................................................................................1028
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description Contents
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
xviii

1 Product Overview
About This Chapter
This chapter provides the positioning of the HUAWEI CX600 Metro Services Platform in the
network.
1.1 Overview
This section describes the position and the features of the device.
HUAWEI CX600-8/16/X3/X8/X16 Metro Service Platform
Hardware Description 1 Product Overview
Issue 03 (2013-11-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1
This manual suits for next models
4
Table of contents
Popular Multi-Service Platform manuals by other brands

Cisco
Cisco IP DECT 6800 Series quick start guide

Braviisol
Braviisol LUI MINI P.A. SPINGO Service manual

Cisco
Cisco ONS 15600 installation instructions

Silicon Laboratories
Silicon Laboratories Si1012 user guide

ENCARDIO RITE
ENCARDIO RITE EWN-01A user manual

Siemens
Siemens SIMATIC NET RUGGEDCOM RX1511 installation manual