Huvitz HS-7000 User manual

------------------------------------------------------ -----------------------------
SLIT LAMP HS
-
7
000
1
Operator’s Manual
SLIT LAMP MICROSCOPE HS
-
7
000

2
SLIT LAMP HS
-
7
000
-------------------
--
--------------------------------------------------
------------
I
MPORTANT NOTICE
!
WARNING
Potential electromagnetic or other interference between medical equipments and other
devices being operated together in the same environmental may expert an adverse
influence on f
unctioning of the medical equipment.
Non
-
medical equipments not in
compliance with the requirements of EN 60601
-
1 and EN 60601
-
1
-
2 should not be
used together in the same environmental as the medical equipments
This equipment has been tested and found t
o comply with the limits for medical devices in
IEC 60601
-
1
-
2:2001.
These limits are designed to provide reasonable protection against
harmful interference in a typical medical installation
Power Cord
For use of equipment in rated voltage less than 125V
ac
, minimum
6A
, Type
SJT or
SVT,
18/3AWG
, 10A
, max 3.0m
long:
One end with Hospital Grade Type, NEMA 5
-
15P
other
end with appliance coupler. For use of equipment in rated voltage less than 250Vac
,
minimum
6A
, Type
SJT or
SVT,
18/3AWG
, 10A
, max 3.0m
long:
O
ne end
terminated
with
blade attachment
plug (
HAR) Type, NEMA 6
-
15P.
This product may malfunction due to electromagnetic waves caused by portable personal
telephones, transceivers, radio
-
controlled toys, etc. Be sure to avoid having objects such as,
which
affect this product, brought near the product.
The information in this publication has been carefully checked and is believed to be entirely
accurate at the time of publication. HUVITZ assumes no responsibility, however, for possible
errors or omissions,
or for any consequences resulting from the use of the ormation
contained herein.

------------------------------------------------------ -----------------------------
SLIT LAMP HS
-
7
000
3
HUVITZ reserves the right to make changes in its products or product specifications at any
time and without prior notice, and is not required to update this documentation
to reflect such
changes.
©200
9
HUVITZ Co., Ltd.
689
-
3, Geumjeong
-
dong, Gunpo
-
si, Gyeonggi
-
do,
435
-
862, Republic of Korea
All rights are reserved.
Under copyright laws, this manual may not be copied, in whole or in part, without the prior
w
ritten consent of HUVITZ Co., Ltd.
Document
Number: 9000ENGJ201
-
A.

4
SLIT LAMP HS
-
7
000
-------------------
--
--------------------------------------------------
------------
Contents
1.
Introduction
................................
................................
................................
.......
6
!
.
2.
Safety Information
................................
................................
..............................
6
3.
Features & Operating Condition
................................
................................
......
14
4.
Standard Components
................................
................................
.....................
16
5.
Accessories
................................
................................
................................
.....
17
6.
Composition
................................
................................
................................
....
18
7.
Installation
................................
................................
................................
.......
24
8.
Trial Operations
................................
................................
...............................
28
9.
Main Features
................................
................................
................................
..
29
10.
Ordinary Maintenance
................................
................................
......................
30
1.1.
Indication for use
...........................
1.2.
Classification
................................
................................
............................
6
2.1.
Introduction
................................
................................
..............................
7
2.2.
Safety Symbols
................................
................................
........................
8
2.3.
Environment factors
................................
................................
................
10
2.4.
Safety Precautions
................................
................................
..................
12
3.1.
Brief Description
................................
................................
.....................
14
3.2.
Operating Condition
................................
................................
................
14
7.1.
Assembling the Instrument
................................
................................
......
24
오류
책갈피가
정의되어
있지
않습니다

------------------------------------------------------ -----------------------------
SLIT LAMP HS
-
7
000
5
11.
EMC Information
................................
................................
..............................
34
12.
Electric Diagram
................................
................................
...............................
43
13.
Technical Specifications
................................
................................
..................
44
14.
Service Information
................................
................................
..........................
46
10.1.
Halogen Projection bulb
................................
................................
..........
30
10.2.
Protection fuses replacement
................................
................................
...
32
10.3.
Cleaning & Disinfection
................................
................................
...........
33
11.1.
Guidance and manufacturer’s declaration
–
electromagnet
ic emissions
......
34
11.2.
Guidance and manufacturer’s declaration
–
electromagnetic immunity
.......
35
11.3.
Guidance and manufacturer’s de
claration
–
electromagnetic immunity
.......
37
11.4.
Recommended separation distances between portable and mobile RF
communications equipment and the EUT
................................
..............................
39
11.5.
Immunity and Compliance Level
................................
..............................
40
11.6.
Guidance and manufacturer’s declaration
–
electromagnetic immunity
.......
41
15. P
articular Information
………………………………………………………………………
.4
8

6
SLIT LAMP HS
-
7
000
-------------------
--
--------------------------------------------------
------------
1.
Introduction
1.1.
Indication for
use (
intended use)
1.2.
Classification
!
CAUTION
The SLIT LAMP, HS
-
7000 is intended for use in eye examination of the ant eye
segments, from the cornea epithelium to the posterior capsule. It is u
sed to aid in the
diagnosis of diseases or trauma which
affects
the structural properties of the anterior
eye segment.
-
Protection against electric shock: Class I
-
Applied Parts: Type B applied parts.
-
Protection against harmful ingress of wa
ter: Ordinary, IPX0
-
Degree of safety in the presence of a flammable anesthetics mixture with air
or with oxygen or with nitrous oxide: Not suitable for use in the presence of a
flammable anesthetics mixture with air or with oxygen or with nitrous oxide.
-
Mo
de of operation: Continuous
-
Light Hazard protection Classification: Group 2 by ISO15004
-
2:2007
-
Stationary:
Do not try to move this equipment without help.
This microscope is
heavy and should maintain stationary. Always get two persons to help lift this
uni
t
Federal law restricts this device to sale by or on the of a physician

------------------------------------------------------ -----------------------------
SLIT LAMP HS
-
7
000
7
2.
Safety Information
2.1.
Introduction
NOTE
!
WARNING
!
CAUTION
Safety is everyone
’
s responsibility. The safe use of this equipment is largely dependent
upon the installer, user, operator, and maintaine
r. It is imperative that personnel study
and become familiar with this entire manual before attempting to
install
use, clean,
service or adjust this equipment and any associated accessories. It is paramount that
the instructions contained in this manual ar
e fully understood and followed to enhance
safety to the patient and the user/operator. It is for this reason that the following safety
notices have been placed appropriately within the text of this manual to highlight safety
related information or informa
tion requiring special emphasis. All users, operators, and
maintainers must be familiar with and pay particular attention to all Warnings and
Cautions incorporated herein.
“
Warning
”
indicates the presence of a hazard that could result in severe persona
l injury,
death or substantial property damage if ignored
.
“
Note
”
describes information for the installation, operation, or maintenance of which is
important but hazard related if ignored.
“
Caution
”
indicates the presence of a hazard that coul
d result in minor injury, or
property damaged if ignored.

8
SLIT LAMP HS
-
7
000
-------------------
--
--------------------------------------------------
------------
2.2.
Safety Symbols
Save this instruction
The International
Electro technical
Commission
(IEC) has established a set of symbols
for medical electronic equipment which classify a connection or warn of any potential
hazards.
The classifications and symbols are shown below.
This applies only to the instrument that has the certification symbol printed explicitly on
the product label or sticker.
I and O on power switch represent ON and OFF respectively.
Type B Isolated patient connection.
This symbol identifies a safety note. Ensure you understand
the function of this control before using it. Control on
is
described in the appropriate User’s or Service Manual.
Identifies the point where the
system safety ground is
fastened to the chassis. Protective earth connected to
conductive parts of
Class I equipment for safety purposes.
Hot surface.

------------------------------------------------------ -----------------------------
SLIT LAMP HS
-
7
000
9
UL60601
-
1
CAN/CSA C22.2
NO.601.1
MEDICAL EUIPMENT
WITH RESPECT TO ELECTRIC SHOCK
FIRE AND M
ECHANICAL HAZARDS
ONLY IN ACCORDANCE WITH UL
60601
-
1,
AND CAN/CSA
C22.2
NO.601.1
Disposal of your old appliance
When this crossed
-
out wheeled bin
symbol is
attached to a
product it
means the
product is covered by the European
Directive 2002/96/EC.
All e
lectrical and electronic products should be disposed of
separately from the municipal waste stream via designated
collection facilities appointed by the government or the local
authorities.
The correct disposal of your old appliance will help prevent
poten
tial negative consequences for the environment and
human health.
4. For more detailed information about disposal of your old
appliance, please contact your city office, waste disposal
service or the shop where you purchased the product.
Alternating Cur
rent

10
SLIT LAMP HS
-
7
000
-------------------
--
--------------------------------------------------
------------
2.3.
Environment factors
Avoid the following environments for operation or storage:
Where the equipment is exposed to water vapor.
Don
’
t operate
equipment
with a wet hand.
Where the equipment is exposed to direct sunlight.
Where the temperatu
re changes
extremely
.
Normal operating temperature range is from 10
C to 40
C,
Humidity is from 30% to 75%.
Altitude is from 700 to 1060hpa
Where it is near the heat equipment.
Where the humidity is extremely high or there i
s a ventilation
problem.
Where the equipment is subject to excessive shocks or
vibrations.
°
°

------------------------------------------------------ -----------------------------
SLIT LAMP HS
-
7
000
11
Where equipment is exposed to chemical material or
explosive gas.
Be careful not to be inserted dust, especially, metal.
Don
’
t disassemble the product
or open. We aren
’
t
responsible for it for nothing.
Be careful not to close the fan located on the lateral or back
side of the equipment.
Don
’
t plug the AC power cord into the outlet before the
connection between devices of the equipment is completed.
This can generate the defect.
Pull out the power cord with holding the plug, not the cord.
Avoid places where the ambient temperature falls below 10
or exceeds 40
for
normal operation, or below
-
10
or exceeds 40
(14
-
104
) for transportation an
d
storage. Humidity should be maintained between 30 and for normal operation,
transportation and storage. The
atmospheric pressure in
operation, transportation and
storage
is from
700
to
1060hp
a
.
℃
℃
℃
℃
℉
℉

12
SLIT LAMP HS
-
7
000
-------------------
--
--------------------------------------------------
------------
2.4.
Safety Precautions
This equipment
has been developed a
nd tested according to safety standards as well
as national and international standards. This guarantees a very high degree of safety
for this device. The legislator expects us to inform the user expressively about the
safety aspects in dealing with the de
vice. The correct handling of this equipment
is
imperative for its safe operation. Therefore, please read carefully all instructions before
switching on this device. For more detailed informatio please contact our Customer
Service Department or one of ou
r authorized representatives.
1.
This equipment
must not be used (a) in an area that is in danger of explosions
and (b) in the presence of flammable, explosive, or vo tile solvent such as
alcohol, benzene or similar chemicals.
2.
Do not put or use this device
in humid rooms. Humidity should be maintained
between 30 and 75% for normal operation. Do not expose the device to water
splashes, dripping water, or sprayed water. Do not place containers containing
fluids, liquids, or gases on top of any electrical equi
pment or devices.
3.
The equipment must be operated only by, or under direct supervision of a
properly trained and qualified person.
4.
Modifications of this equipment
may only be carried out by Huvitz
’
s service
technicians or other authorized persons.
5.
Custom
er maintenance of this equipment
may only be performed as stated in
the User
’
s Manual and Service Manual. Any additional maintenance may only
be performed by Huvitz
’
s service technicians or other authorized persons.
6.
The manufacturer is only responsible fo
r effects on safety, reliability, and
performance of this equipment when the following requirements are fulfilled: (1)
The electrical installation in the respective room corresponds to the
specifications stated in this manual and (2) This equipment is used
, operated,

------------------------------------------------------ -----------------------------
SLIT LAMP HS
-
7
000
13
And
maintained according to this manual and Service Manual.
7.
The manufacturer is not liable for damage caused by unauthorized tampering
with the device(s). Such tampering will forfeit any rights to claim under
warranty.
8.
This equipment
may on
ly be used together with accessories supplied by
Huvitz
’
s. If the customer makes use of other accessories, use them only if their
safe usability under technical safety aspects has been proved and confirmed
by Huvitz or the manufacturer of the accessory.
9.
O
nly persons who have undergone proper training and instructions are
authorized to install, use, operate, and maintain this equipment.
10.
Keep the User
’
s Manual and Service Manual in a place easily accessible at all
times for persons operating and maintaining
the equipment.
11.
Do not force cable connections. If a cable does not connect easily, be sure that
the connector (plug) is appropriate for the
receptacle
(socket). If youcause any
damage to a cable connector(s) or receptacle(s), let the damage(s) be repair
ed
by an authorized service technician.
12.
Please do not pull on any cable. Always hold on to the plug when
disconnecting cables.
13.
Before every operation, visually check the equipment for exterior mechanical
damage(s) and for proper function.
14.
Do not cover a
ny ventilation grids or slits.
15.
Immediately turn off and unplug any equipment that gives off smoke, sparks,
strange noises, or odors.
16.
Power Supply Cord set (international)
-
(Detachable) Rated 10 A, 250 V. Plug
type CEE 7/VII, Connector type IEC 60320/C13
, and Cord type H05VV
-
F3G,
min. 0.75 mm2, 3
-
conductor terminating in molded
-
on grounding type
attachment plug. <HAR> marked on the cord. Maximum 4.0 m long
.

14
SLIT LAMP HS
-
7
000
-------------------
--
--------------------------------------------------
------------
3.
Features & Operating Condition
3.1.
Brief Description
3.2.
Operating Condition
The
device works like all slit lamps:
Stereomic
roscopic
examination of the eye under the slit light.
Microscopic
examination of the ocular fundus and posterior vitreou body (using
h
rub
y
’
s lens).
These devices are designed for use by ophthalmologists and
optometrists (
within the
realms of their respect
ive professions) for specific diagnostic
procedures (
bio
-
microscopic examination of the eye)
As long as the slit lamp is in its original package it can be exposed to the
following environmental conditions for up to 15 weeks ship
ping and storage
without risk of damage:
-
Temperature
range:
from
–
10
C to +40
C;
-
Relative humidity range: from 30% to75%;
The device is made to operate under the following environmental conditions:
-
Temperature
range:
from +1
0
C to +
4
0
C;
-
Relative humidity range: from 30%
to
75%;
The device
neither
generates nor receiv
es electromagnetic interference when used
near other equipment. Therefore, no preventive or corrective measures are required
-
-
l
l
˚
˚
˚
˚

------------------------------------------------------ -----------------------------
SLIT LAMP HS
-
7
000
15
!
CAUTION
Because prolonged intense light exposure can damage the retina, the use of the device
for ocular examination should not be unne
cessarily prolonged, and the brightness
setting should not exceed what is needed to provide cl visualization of the target
structures. This device should be used with filters that eliminate UV
radiation
(
<400nm
) and
, whene ver possible, filters that elim
inate short
-
wavelength blue
light
(
<420nm).
The retinal exposure dose for a photochemical hazard is a product of the radiance and
the exposure time. If the value of radiance were reduc in half, twice the time would
be needed to reach the maximum exposure
limit.
While no acute optical radiation hazards have been identified for slit lamps, it is
recommended that the intensity of light directed into patient
’
s eye be limited to the
minimum level which is necessary for diagnosis. Infants, aphakes and perso
ns with
diseased eyes will be at greater risk. The risk may also increased of the person being
examined has had any exposure with the same instrument or any other ophthalmic
instrument using a visible light source during the previous 24 hours. This will ap
ply
particularly if the eye has been exposed to retinal photography

16
SLIT LAMP HS
-
7
000
-------------------
--
--------------------------------------------------
------------
4.
Standard Components
The instrument is delivered in package. Taking it out the package, make sure that
none of the following parts is missing.
A table top(N.B. the table top isn
’
t
supplied with the slit lamp for twin table) on
which are placed: A SMPS box(15) including the main switch & a warning
light (13), Two sliding guides for the base with orthogonal movements(17), A
sliding plate for the position device(19), Adrawer(16);
A
base with orthogonal movements.
A microscope with either dual magnification or a
system (
31) including
eyepieces.
An optical group of the slit projector.
A head rest
module (
59).
A
microscope
arm (
45).
This manual.
A set of accessories including; two
wheels for the sliding guides(18); a setting
rod(43); a protective cover(46); a spare bulb 12V 30W ogen bulb(53); two
protection fuses(48); a breath screen(19); a chin
-
rest paper(47);a hole
cover(45); a power cable; two patient
’
s handles(50)
l
l
l
l
l
l
l
l

------------------------------------------------------ -----------------------------
SLIT LAMP HS
-
7
000
17
5.
Accessori
es
The following standard accessories are provided with the instrument;
protection cover(46)
a setting rod(43)
spare bulbs
12V 30W Halogen
bulb (
53)
chin
-
rest paper(47)
spare fuses
250Vac T2.0AL
a breath screen(5)
power cable
l
l
l
l
l
l
l
[ Figure 1. Accessories ]

18
SLIT LAMP HS
-
7
000
-------------------
--
--------------------------------------------------
------------
6.
Composition
1)
Fixation point
2)
Control lever for changing enlargement
3)
Removable eye
-
pieces
4)
Knob for clamping the breath screen
5)
Breath screen
6)
Control handle for the slit rotation 90
-
0
-
90
7)
Connecting plug of the projector lamp
8)
Knurled ring for filters insertion
9)
Joystick fo
r lateral, longitudinal and vertical movements(x y z)
10)
Base with orthogonal movements
11)
Shaped tabletop
12)
Warning light indicating the ignition of the SMPS is on
13)
Main switch
& Warning light
14)
Luminosity selector
15)
SMPS box
16)
Drawer
17)
Toothed guides
18)
Wheel protection cra
nkcases
19)
S
liding plate
20)
Knob to lock the projector
21)
Scale for the projector position
22)
Knob to lock the arm of the microscope
23)
Hole cover
24)
Knurled
knob
to lock the Lamp housing
25)
Control handle
for the vertical setting of the chin
-
rest

------------------------------------------------------ -----------------------------
SLIT LAMP HS
-
7
000
19
26)
Locking pins for chin rest pa
per
27)
Chin rest
28)
Knobs to change the slit width
29)
Pointer for the eye positioning
30)
Foreh
ead
R
est
31)
Microscope
32)
Lamp socket
33)
Knob to lock the base of the instrument
34)
Knob to lock the microscope
35)
Control handle for horizontal tilting
36)
Control lever for vertical tilting
37)
Microscope position stop
38)
Graduated ring 90
-
0
-
90 determining the inclination of the slit during rotation
39)
Lamp cover
40)
fuse slots
41)
Connecting plug
42)
Fixation point connector
43)
Setting rod
44)
Microscope separation knob
45)
Microscope arm
46)
Protection cover
47)
Chin rest papers
48)
G
uide screw
49)
An optical group of the slit projector
50)
Patient
’
s handle
51)
Head
rest fastening screw
52)
Wheel
53)
Halogen bulb 12V 30W

20
SLIT LAMP HS
-
7
000
-------------------
--
--------------------------------------------------
------------
54)
Bulb fastening knob
55)
Mirror
56)
Capture connector ( For the image system)
57)
Capture switch
58)
Luminosity selector connector ( Connect the Luminos
ity selector to the
SMPS)
59)
Head rest module
Table of contents
Other Huvitz Microscope manuals

Huvitz
Huvitz HSZ-700 User manual

Huvitz
Huvitz HS-5000 2X User manual

Huvitz
Huvitz HS-5000 3X User manual

Huvitz
Huvitz HS-5500 User manual

Huvitz
Huvitz HSZ-600 User manual

Huvitz
Huvitz HS-7500 User manual

Huvitz
Huvitz HS-5000 5X User manual

Huvitz
Huvitz HS-5000 SX User manual

Huvitz
Huvitz HRM-300 User manual
Popular Microscope manuals by other brands

Stalwart
Stalwart STM-2036 Series instruction manual

STEINDORFF
STEINDORFF S-1260 instruction manual

Madell Technology Corporation
Madell Technology Corporation SZMB2 user manual

BestScope
BestScope BS-2080MH4 user manual

Accu-Scope
Accu-Scope 3025 Supplemental instructions

Nikon
Nikon Eclipse Ti-E instructions