HYCON HY16F3981 Instructions for use

HY16F3981
IDE Hardware User’s Manual
© 2017~2022 HYCON Technology Corp
www.hycontek.com
APD-HY16IDE012-V02_EN
page2
Table of Contents
1. PACKAGE CONTENTS............................................................................................................................4
2. SAFETY PRECAUTIONS.........................................................................................................................5
3. SOFTWARE INSTALLATION REQUIREMENTS.....................................................................................6
3.1. IDE Software Installation Requirements...............................................................................................6
4. DESCRIPTION OF THE IDE HARDWARE (HY16F MINI LINK) .............................................................7
4.1. Schematic architecture description.......................................................................................................7
4.2. Mini Link diagram..................................................................................................................................7
4.3. Mini Link connection with EDM.............................................................................................................8
4.4. Connection Diagram of Mini Link and Target Board (Powered by Mini Link) .......................................8
5. HARDWARE TARGET BOARD INTRODUCTION...................................................................................9
5.1. Target Board Features..........................................................................................................................9
5.2. External Power Supply and Precautions.............................................................................................10
5.3. Target Board Circuit Diagram.............................................................................................................. 11
6. LCD BOARD INTRODUCTION..............................................................................................................12
7. HARDWARE CONNECTION INTRODUCTION.....................................................................................13
8. REVISIONS.............................................................................................................................................14
.

HY16F3981
IDE Hardware User’s Manual
© 2017~2022 HYCON Technology Corp
www.hycontek.com
APD-HY16IDE012-V02_EN
page3
Attention:
1、HYCON Technology Corp. reserves the right to change the content of this datasheet
without further notice. For most up-to-date information, please constantly visit our
website: http://www.hycontek.com .
2、HYCON Technology Corp. is not responsible for problems caused by figures or
application circuits narrated herein whose related industrial properties belong to third
parties.
3、Specifications of any HYCON Technology Corp. products detailed or contained herein
stipulate the performance, characteristics, and functions of the specified products in the
independent state. We does not guarantee of the performance, characteristics, and
functions of the specified products as placed in the customer’s products or equipment.
Constant and sufficient verification and evaluation is highly advised.
4、Please note the operating conditions of input voltage, output voltage and load current
and ensure the IC internal power consumption does not exceed that of package
tolerance. HYCON Technology Corp. assumes no responsibility for equipment failures
that resulted from using products at values that exceed, even momentarily, rated
values listed in products specifications of HYCON products specified herein.
5、Notwithstanding this product has built-in ESD protection circuit, please do not exert
excessive static electricity to protection circuit.
6、Products specified or contained herein cannot be employed in applications which
require extremely high levels of reliability, such as device or equipment affecting the
human body, health/medical equipments, security systems, or any apparatus installed
in aircrafts and other vehicles.
7、Despite the fact that HYCON Technology Corp. endeavors to enhance product quality
as well as reliability in every possible way, failure or malfunction of semiconductor
products may happen. Hence, users are strongly recommended to comply with safety
design including redundancy and fire-precaution equipments to prevent any accidents
and fires that may follow.
8、Use of the information described herein for other purposes and/or reproduction or
copying without the permission of HYCON Technology Corp. is strictly prohibited.
.

HY16F3981
IDE Hardware User’s Manual
© 2017~2022 HYCON Technology Corp
www.hycontek.com
APD-HY16IDE012-V02_EN
page4
1. Package Contents
HY16F3981 IDE Hardware development kit includes HY16F Mini Link and HY16F3981-
L064 Target Board.
Integrated Hardware development kit helps to develop MCU application program of
HY16F3981. Program compiling, hardware debug, IC programming was implemented
through NB/PC end connection.
Serial number
Name
Spec
Quantity
HY16F3981-
DK01
1. HY16F3981-L064 Target Board
HY16F3981-IM02
1
2. HY16F Mini Link debug tool
HY16000-CM04
1
3. USB cable
USB Type A to Mini B
Cable
1
4. EDM line
5pin to 4x2pin
(2.54mm pitch)
1
.

HY16F3981
IDE Hardware User’s Manual
© 2017~2022 HYCON Technology Corp
www.hycontek.com
APD-HY16IDE012-V02_EN
page5
2. Safety Precautions
Do not place heavy objects on the display panel, in order to avoid damage caused by
stress.
Place the application display boards at steady place, so as to avoid falling damage.
Do not use this product with the input voltage which is not meeting the electrical
specifications, , in order to avoid working abnormally or damage
Avoid application display boards being touched by liquid, dirt and avoid being exposed
to moisture during operation. This application should be kept in a dry environment, so
as not to affect the function and performance
Remove the power supply when not using it.
When following status occurred, please remove the power supply immediately, and
contact our engineer.
Power Supply line is worn or damaged.
Power source (battery) connected but no any light on while operating.
Component off.
.

HY16F3981
IDE Hardware User’s Manual
© 2017~2022 HYCON Technology Corp
www.hycontek.com
APD-HY16IDE012-V02_EN
page6
3. Software Installation Requirements
3.1. IDE Software Installation Requirements
Minimum System Requirements of operating AndeSight RDS:
(1) PC/NB hardware requirement:
IBM PC compatible X86 system CPU
4GB Memory
8GB Hard disk
(2) Product number support:
HY16F3981
(3) Hardware model support:
HY16F3981 development tools, HY16F3981-DK02.
(4) Software version support:
AndeSight V2.3.1 RDSp3 version above
Device => HY16F_RDSp3_DeviceV0.1
Mini Link Version information => Andes AICE-MINI v1.0.1
(5) Operating system support:
Windows XP, Windows Vista, Windows 7, Windows 8, Windows 10
(6) Apply the following interface modes:
USB Port
.

HY16F3981
IDE Hardware User’s Manual
© 2017~2022 HYCON Technology Corp
www.hycontek.com
APD-HY16IDE012-V02_EN
page7
4. Description of the IDE hardware (HY16F Mini Link)
4.1. Schematic architecture description
HY16F Mini Link (AICE) for the HY16F3981-L064 Target Board and PC / NB end, the
middle connection device. Mainly used as a Programming program and Debug mode.
AndeSight
RDS S/W
USB2.0 EDM line
HY16F3981
Target Board
PC/NB
EDM
ICE
Note: EDM (Embedded debug module)
4.2. Mini Link diagram
Pin Name
Description
RST
Reset Pin
VDD
The VDD pin of the Mini Link is fixed to provide 3.3V, And to provide
IC (HY16F3981-L064) power directly from the Target Board EDM
Pin7.
ECK
EDM Clock Pin
EDIO
EDM Data Input / Output Pin
VSS
Ground Pin
.

HY16F3981
IDE Hardware User’s Manual
© 2017~2022 HYCON Technology Corp
www.hycontek.com
APD-HY16IDE012-V02_EN
page8
Mini Link LED Description:
POWER LED (Green LED): When the USB Port connection, POWER LED will
continue to light.
ACTIVE LED (Yellow LED): When enter Debug Mode, ACTIVE LED will flash
continuously.
ERROR LED (Red LED): When the USB Port is connected but the Target Board is not
connected, the Error LED is on.
4.3. Mini Link connection with EDM
HY16F
Mini Link EDM line Target Board EDM
1
2
RST (Blue)-> Target board EDM Pin2
VDD (Red)-> Target board EDM Pin7
ECK(Green)-> Target board EDM Pin6
EDIO(Yellow)-> Target board EDM Pin4
VSS(Black)-> Target board EDM Pin3,5
4.4. Connection Diagram of Mini Link and Target Board (Powered by Mini Link)
Step1: The EDM Line Connection Mini Link and Target Board.
Step2: Connect the PC's USB Port to the Mini Link.
Step3: The Power LED is on.
STEP1
STEP2
STEP3
.

HY16F3981
IDE Hardware User’s Manual
© 2017~2022 HYCON Technology Corp
www.hycontek.com
APD-HY16IDE012-V02_EN
page9
5. Hardware Target Board Introduction
1. 4Com x 17Seg LCD Panel
11. HY16F3981-L064
4. EDM port
8. Tack Switch x 2
7. Power Management
9. External HSXT 4MHz
and LSXT 32768Hz
13. Bridge Sensor
Connector
10. 4 wires SPI
connector
6. JP8,JP9
12. Power LED
5. External power switch
2. Writer connector(5pin)
3. MCU reset switch
5.1. Target Board Features
No.
Name
Description
1
4Com*17Seg
LCD Panel
See Chapter 6 for details
2
Writer connector
Programming IC use
3
MCU reset switch
Reset MCU is used
4
EDM Port
Connection Mini Link
(See Section 4.3 ICE Connection for details)
5
External power switch
see section 5.2
6
JP8,JP9
External Power (see section 5.2)
7
Power Management
External power supply voltage regulator circuit
(see section 5.2)
8
Tack Switch*2
S2 and S3 are Tack Switches
.

HY16F3981
IDE Hardware User’s Manual
© 2017~2022 HYCON Technology Corp
www.hycontek.com
APD-HY16IDE012-V02_EN
page10
9
External HSXT
and LSXT
External HSXT (4MHz) & LSXT (32768Hz)
10
4 wires SPI Connector
4 wires SPI Interface
11
HY16F3981-L064
HY16F3981 LQFP64 MCU
12
Power LED
When the Target Board is powered normally, the
Power LED is on
13
Bridge Sensor
Connector
ADC Input Pin AI0 & AI1
5.2. External Power Supply and Precautions
Use an external power supply method (Through the Power Management will power
regulator into 3V, and then provided to HY16F3981 IC)
5.2.1. Use an external power supply step
Step1: Remove the EDM Line
Step2: By JP8 (+), JP9 (-) to provide external power supply.
(Input range VDD~9.0V)
Step3: Press S4 switch (External power switch) Through the Power Management will
power regulator into 3V, and then provided to HY16F3981 IC
STEP1
STEP3
STEP2
Precautions:
Because Mini Link supplied power = 3.3V, so when want to use an external power
supply, be sure to remove EDM line, avoid voltage different voltages caused conflict.
.

HY16F3981
IDE Hardware User’s Manual
© 2017~2022 HYCON Technology Corp
www.hycontek.com
APD-HY16IDE012-V02_EN
page12
6. LCD Board Introduction
The LCD panel on HY16F3981-L064 Target Board is HYCON self-owned mold, it’s symbol
and pin diagram is shown in below graph. It’s panel specification is as follows:
(1) Operating Voltage: 3.0V
(2) Visible Angle: 60 degree
(3) Operating Frequency: 60Hz
(4) Bias:1/3 bias
(5) Waveform:1/4 duty
(6) Pin: 90 degree
TARE
ZERO
A
m
K
M
Ω
V
g
F
G
E
D
A
B
C
H
S1
S5
S6
S7
S8
S9
S10
S11
S12
S13
S14
S15
S16
S17
S18
S19
S20
S21
SEG0 SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 SEG16
COM0 1F 1A 2F 2A 3F 3A 4F 4A 5F 5A 6F 6A S1 S5 S10 S9 S18
COM1 1G 1B 2G 2B 3G 3B 4G 4B 5G 5B 6G 6B S2 S6 S11 S14 S19
COM2 1E 1C 2E 2C 3E 3C 4E 4C 5E 5C 6E 6C S3 S7 S12 S15 S20
COM3 1D 1H 2D 2H 3D 3H 4D 4H 5D 5H 6D S17 S4 S8 S13 S16 S21
1 2 3 4 5 6
S2 S3 S4
TARE
ZERO
A
m
K
M
Ω
V
g
70mm
27mm
2.54mm
17.78mm
0.812mm
121
8.89mm
PIN 1 2 3 4 5 6 7 8 9 10 11
I/O COM0 COM1 COM2 COM3 SEG0 SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
PIN 12 13 14 15 16 17 18 19 20 21
I/O SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 SEG16
.

HY16F3981
IDE Hardware User’s Manual
© 2017~2022 HYCON Technology Corp
www.hycontek.com
APD-HY16IDE012-V02_EN
page13
7. Hardware Connection Introduction
For driver install, please refer to HY16F Series, IDE Software User’s Manual.
AICE USB driver program will install automatically when the software is installed.
For correct AICE connection status, libusb-win32 devices of AICE (which is Mini Link) will
show up under PC device administrator.
EDM connection test:
1. Connect the Mini Link to the Target Board according to Section 4.4
2. Open the AndeSight IDE software. (Please refer to installation HY16F series IDE
software installation steps)
(2.1) In the Target Manager: Local Targets window
(2.2) Select HY16F3981 by right-clicking (Select Connect Target via AICE)
(2.3) Successful connection appears HY16F3981 AICE: 9902
(2.4) From the Console window, can see the version information of the Mini Link:
Andes AICE-MINI v1.0.1
.

HY16F3981
IDE Hardware User’s Manual
© 2017~2022 HYCON Technology Corp
www.hycontek.com
APD-HY16IDE012-V02_EN
page14
8. Revisions
The following describes the major changes made to the document, excluding the
punctuation and font changes.
Version
Page
Summary of Changes
V01
ALL
First Edition
V02
4,8~11
1. Modify the version of HY16F3981 ICE Board.
2. Modify the version of the Target Board circuit diagram
.
This manual suits for next models
1
Table of contents
Other HYCON Microcontroller manuals