Hydrofarm ACTIVE AIR ACAN12 User manual

INSTRUCTION MANUAL
ACAN12
Portable Air
Conditioner
Dual Mode: Air Conditioner or Fan

READ MANUAL CAREFULLY BEFORE OPERATING
INTRODUCTION
Thank you for purchasing the ActiveAir analog portable air-conditioner (item#
ACAN12) for use in your home or garden. This unit provides cooling, fan func-
tions, operates quietly, and requires minimal installation effort.
When operating as an air conditioner, this unit is designed for spot cooling, optimal
for a room no larger than 100 square feet with a standard ceiling height of 8 feet.
Use in gardening applications should NOT exceed (2) 1000 watt, AIR-COOLED
lighting systems. Please note the evaporator air intake on the back of the unit will
exchange a small amount of air from the room in which it sits, through the exhaust
outlet. For optimal CO2 supplementation, this unit should cycle off during times of
induction activity.
The unit incorporates a power outage auto reset function and will automatically
restore the last setting of operation selected prior to the power outage. If using a
cycle timer please allow a minimum 3 minute interval of OFF time before cycling
the compressor back on. Failure to do so may damage the operation.
PACKAGE CONTENTS
1 - Mobile Air Conditioner Unit
2 - Exhaust Ducting Pipes
2 - Window Kit Adapter
1 - Window Insert Kit, consisting of –
1 Vent Panel (28 ¼”)
1 Extension Assembly (outer solid panel with inner sliding
extender-- 28 ¼” up to 80”)
2 - Air Flow Terminal Covers.
2 - Ducting Covers.
1 - Instruction Manual.
IMPORTANT SAFEGUARDS
Before using your portable air conditioner, please read all parts of this manual thor-
oughly.
1. Do NOT place the unit in any position besides vertical, even temporarily or for stor-
age. If placed in any position other than upright, the unit must be left to sit right side
up for approximately (2) hours.
2. If the unit is turned off or if power is lost, wait 3 full minutes before restarting the
cooling mode.
3. Flammable vapor and liquids should never be placed near this unit.
4. Maintain at least 10” (25cm) of clearance around this unit. Do not cover or block
air ow through the inlet or outlet grills, doing so may result in internal damage to the
unit.
5. The power supply must be properly grounded into a 120V outlet.
6. Do NOT use an adapter plug or extension cord on the unit.
7. Be careful not to spray or pour water directly on the unit, into the inlet or outlet
grilles. Keep the unit at a safe distance from open water supplies and sources.
8. Do not allow children to access this unit.
FEATURES
1 2

1) Window and Wall Venting Methods
a) Window Venting Method
i) Locate the Window Insert Kit and Window Kit Adaptors.
ii) Select an appropriate window or door and place the air conditioning unit as close to
it as possible.
iii) Attach the Window Kit Adaptors to the open ends of the intake and exhaust duct-
ing pipes. To do this rst pull the open end of the ducting so that approximately 6”
of it is fully extended. Screw the Window Kit Adaptor clockwise onto the ends of the
ducting pipes to secure the attachment.
iv) The Window Insert Kit consists of one Vent Panel with two large rectangular open-
ings and an Extension Assembly with two solid sliding panels. The inner extender
panel slides into the C-channel at the back of both outer panels to double the length of
the insert or extend it to t a sliding door.
v) If necessary, you may nd it easier to cut the Extension Assembly to get a more
exact t.
vi) Make sure that both openings on the Vent Panel are not covered by other pieces.
Restricting the airow may damage the internal components.
vii) Secure the Window Insert Kit in the selected window or door opening and close
the window or door on it tightly. The at side of the outer panels faces inward into the
room. The back side with the C-channel faces out the window/door to the outside.
viii) The Window Kit Adaptors snap into the openings of the Vent Panel. Each Adap-
tor connects one Ducting pipe to one opening in the Vent Panel. Extend the ducting as
far as necessary to reach the Vent Panel.
b) Wall Venting Method
i) Wall Venting Method requires competent individual building skills.
ii) Do not use the Window Kit Adapters or Window Insert Kit.
iii) Prepare two 5” diameter holes in the outer wall of the room for exhaust and air intake.
EXHAUST DUCTING ASSEMBLY WINDOW INSERT KIT
INSTALLATION INSTRUCTIONS
When the unit operates as an air conditioner, fresh outdoor air must be drawn into
the unit and the hot exhaust air must be vented out of the room in order to com-
plete proper air exchange. When the unit is operating on fan mode, no outdoor air
exchange takes place. The exhaust hose is bypassed when operating solely on the
fan function.
• The unit should have the intake and exhaust ducting assemblies pre-installed for
easy installation.
34

OPERATING INSTRUCTIONS
iv) Position the two ends of the Exhaust Ducting pipes in these holes in the wall. Seal
with duct tape or other appropriate materials.
v) You may be able to use the Exhaust Outlet Covers to help seal the openings in the
wall when the unit is not in use.
vi) Although the Exhaust Ducting may be extended up to about 6 feet, for increased
efciency keep the exhaust ducting as short and straight as possible.
NOTE:
• Do NOT attach further extensions or booster fans to the exhaust ducting. Doing
so beyond that provided by the manufacturer may impede the operation of the
unit, cause damage to it, and will void the warranty.
2) To Detach Intake/Exhaust Ducting:
a) Turn the attachment collars clockwise and lift them to remove the duct assemblies
from the intake and outtake Air Flow Terminals on the unit.
b) Duct covers will screw down into place over the intake/exhaust ports to protect
them for periods of extended storage.
OPERATING INSTRUCTIONS
1. Ensure that the Selector is set to OFF.
2. Plug the unit into a 120V, grounded outlet.
3. After turning on the power, use the SELECTOR to select the desired mode of op-
eration: LOW FAN, HI FAN, LOW COOL, or HI COOL.
4. Use the THERMOSTAT dial to select the desired ideal temperature.
NOTE: IN ORDER TO AVOID COMPRESSOR OVERLOAD, PLEASE WAIT 3
MINUTES AFTER THE COMPRESSOR STOPS BEFORE RESTARTING.
MAINTENANCE
NOTE: MAKE SURE MODE SELECTOR IS SET TO OFF AND THE PLUG IS PULLED
OUT OF THE POWER OUTLET BEFORE PERFORMING ANY MAINTENANCE AC-
TIVITIES.
1) CLEANING OR REPLACING THE FILTER
a) If the air lter becomes dirty or dusty, airow will be reduced. It is recommended to
clean the lter at least once every two weeks or more often as needed.
b)The lter compartment is located in the upper part on the back of the unit.
c) Lift the lter frame upward to remove it from the lter compartment.
d) Wash the air lter by immersing it gently into warm (about 104 F) water with a mild
detergent.
e) Rinse the lter thoroughly and allow it to dry out completely before replacing it in the
unit. Do not expose the lter to direct sunlight.
f) When it is ready, slide the lter frame back down into the lter compartment.
g) If the lter is torn or unusable order a new lter through your retailer.
2) CLEANING THE OUTER CASE
a) Keep the unit from being exposed to direct sunlight to avoid possible color fading.
b) Clean the surface with a damp cloth and dry with a soft towel.
1 - Use THERMOSTAT to adjust
temperature
2 - Use SELECSTOR to turn unit on/off
56

OPERATING INSTRUCTIONS
3) TRANSPORT/ EXTENDED STORAGE
a) Empty the water by unplugging the water drainage stop at the back towards the bot-
tom of the unit. Use a drain tube to a oor drain for automatic and continuous deple-
tion.
b) Unplug the unit from the electrical outlet.
c) Store the unit in a cool dry place, preferably covered with plastic sheeting.
4) RECHARGING THE UNIT
a) We do not recommend that the operator attempt to recharge or replace the coolant
in this unit. Failure to do so could result in a ne as stated by the EPA.
b) If there is a leak, return the unit to the place of purchase, along with a receipt for
warranty work.
NOTE:
1) The above cooling capacity is measured at ambient temperatures of DB 86 F, WB 78 F.
2) Noise level is measured at 3.28 ft away from the front of the unit, in cooling mode.
3) Power consumption rating is measured with the fan running at the highest speed.
4) If the ambient temperature is higher than the maximum operating temperature or low-
er than the minimum operating temperature, the air conditioner may not work properly.
5) A power cut off sensor will activate if excessive water accumulates from the condens-
er. It is wise to check the unit and ensure water is properly disposing if humidity levels
are above 50 percent in the area.
6) Specications above are for reference only. Please see the actual data printed on the
nameplate.
TECHNICAL SPECIFICATIONS
78
Warranty Information Here
Other manuals for ACTIVE AIR ACAN12
1
Table of contents
Other Hydrofarm Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual