Hydrofarm Active Air ACAN1402 User manual

INSTRUCTION MANUAL
ACAN1402
PORTABLE AIR CONDITIONER

INSTRUCTION MANUAL
www.Hydrofarm.com
2
WHAT’S IN THE BOX
Part
Description
Quantity
Main air conditioner unit 1
2
Hose connector(window end) 2
Hose adaptor(air conditioner end) 2
Window kit 1
Remote control 1
Drain hose 1
SILENT
Ducting hope
Part
Description
Quantity
Main air conditioner unit 1
2
Hose connector(window end) 2
Hose adaptor(air conditioner end) 2
Window kit 1
Remote control 1
Drain hose 1
SILENT
Ducting hope
1 – Window kit
1 – Remote control
Overview of Air Conditioner Unit
4
disconnect the power supply. It must be replaced from the dealer or a designated repair shop.
Name of Parts (We only need to show Dual duct one, please delete
single duct from below image)
Control Panel and Remote Control
5
Fig.1
Accessories
Please refer to the Parts list that I attached in CMW ticket.
After unpacking, please check whether the above-mentioned accessories are included, and
check their purposes in the installation introduction in this manual.
Introduction to Panel and Remote Controller
Fig.3
• The POWER
• The SPEED
• The TEMP+
• The TEMP-
• The MODE
• The SLEEP
• The TIMER
• The SWING

INSTRUCTION MANUAL
3
SAFETY
*IMPORTANT: If any parts are damaged,
turn o the Power switch and disconnect
the power supply immediately. Contact an
authorized service technician for repair or
maintenance of this unit.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualied persons in order
to avoid a hazard.
*IMPORTANT: Any person who is involved
with working on or breaking into a
refrigerant circuit should hold a current
valid cercate from an industry-accredited
assessment authority, which authorizes their
competence to handle refrigerants safely
in accordance with an industry recognized
assessment specicaon.
Maintenance and repairs shall be performed
only as recommended by the equipment
manufacturer. Maintenance and repair
requiring the assistance of other skilled
personnel shall be carried out under the
supervision of a person competent in the
use of ammable refrigerants.

INSTRUCTION MANUAL
www.Hydrofarm.com
INSTALLATING THE AIR CONDITIONER
NOTE: Do not aempt to operate this unit without properly
venlang it, as this will not work to cool the room and will
void the warranty. The exhaust and intake ducts must be
routed outside the room to the exterior of the structure.
Window Slider Kit Installation
8
Operation Introduction
Before starting operations in this section:
1) Find a place where there is power supply nearby.
2) As shown in Fig.5 and Fig.5a, install the exhaust hose, and adjust the window position well.
Please delete the singe duct unit from the image below. We only need to keep dual duct.
Fig.5 Fig.5a
12"
(30 cm) 12"
(30 cm)
13
Fig.9
Maintenance Explanations
Declaration:
1) Before cleaning, be sure to disconnect the unit from any electric supply outlet;
2) Do not use gasoline or other chemicals to clean the unit;
3) Do not wash the unit directly;
4) If the conditioner is damaged, please contact the dealer or repair shop.
Figure 2
Figure 1
12
Fig.7
2. Introduction to Exhaust Hose Installation
Fig.8
A) Temporary installation
1. Twist both ends of the exhaust hose into the square fixing clip and the flat fixing clip.
2. Insert the square fixing clip into openings at back of the air conditioner (see Fig.9).
3. Put the other end of the exhaust hose to the near windowsill.
Window Slider Kit Installation
The installation manner of window slider kit is mostly in “horizontal” and “vertical”, No much
difference in actual process.
As shown Fig.9, check the min. and max. size of the window.

INSTRUCTION MANUAL
5
USING THE AIR CONDITIONER
*CAUTION: Always wait at least three minutes before switching from cooling to dehumidifying.
Important: Operation temperature range
MAXIMUM COOLING MINIMUM COOLING
MAXIMUM HEATING MINIMUM HEATING
AUTO Mode
ROOM TEMPERATURE(Tr) ≤Tr < 70FTr ≥ 79F
MODE
Set Temperature
Cooling
MODE
TEMP+ or
TEMP-
SPEED
Dehumidifying
MODE
Fan
MODE
SPEED

INSTRUCTION MANUAL
www.Hydrofarm.com
6
Turning the Timer ON/OFF
TIMER
TEMP+ or TEMP-
Setting the Timer
Setting the ON time:
With the unit
the TIMER
TEMP+ or
TEMP-
unit to turn on
TIMER
Setting the OFF time:
TIMER
TEMP+ or TEMP-
TIMER
Oponal: Press the TIMER buon again to revert the panel to the temperature display. Your
me will remain set.
(Note: This mer funcon would rarely be used in a grow room situaon, and is much more useful
when the air condioner is used for common household cooling use.)
SWING (Air Flow)
SWING
SWING

INSTRUCTION MANUAL
7
SLEEP Control Function
SLEEP
SLEEP
SLEEP
Draining the Inner Water Tank
Intermittent Drainage
Continuous Drainage
CLEANING THE AIR CONDITIONER
•
•
•
•
•
•
9
3) Insert the power cord into an grounded AC115V/60Hz socket;
4) Press the POWER button to turn on the air-conditioner.
Please delete the singe duct unit from the image below. We only need to keep dual duct.
Fig.6
1.Before using
Notice:
-Operation temperature range:
Check up whether the exhaust hose has been mounted properly.
Cautions for cooling and dehumidifying operations:
-When using functions on cooling and dehumidifying, keep an interval of at least 3 minutes
between each ON/OFF.
-Power supply meets the requirements.
-The socket is for AC use.
-Do not share one socket with other appliances.
-Power supply is AC115V,60Hz
2.AUTO MODE(without WIFI function)
Maximum cooling
Minimum cooling
DB/WB(�)
95 /75 O
F
64/54 O
F
Maximum heating
Minimum heating
DB/WB(�)
81/---O
F
45/---O
F

INSTRUCTION MANUAL
www.Hydrofarm.com
8
TROUBLESHOOTING
Issue Possible Causes Suggested Remedies
Unit does not start
when pressing on/off
button.
Unit does not cool the
room enough.
2
Unit is too noisy.
E0 Code
E3 Code
E1 Code
E2 Code

INSTRUCTION MANUAL
9
FAQs
Is the unit sealed? Will it draw CO2out of my tent?
2
Will it work with a controller/thermostat?
What is deadband?
Why isn’t there a dehumidify and cool mode together?
What about the water that collects?
Can I extend the ducng?
My TV remote is changing sengs on the AC! How do I stop this?
SPECIFICATIONS – ACAN1402
Input
Refrigerant type
Weight
Warranty

www.Hydrofarm.com
WARRANTY
LIMITED WARRANTY
ACAN1402
ACAN1402
ACAN1402
ACAN1402_Instructions | rev. April 8, 2019 4:44 pm
Table of contents
Other Hydrofarm Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual