i3 International UI08 User manual

i3-TRNG-ACCESSORIES-UIO8.indd Rev. 200510
Universal Input/Output Device
UIO8
User Manual
Scan this QR code or visit ftp.i3international.com for a
complete range of i3 product quick guides and manuals.
Contact our Technical Support team at: 1.877.877.7241 or
concerns regarding camera installation or if you require software
services or support.
Thank you for purchasing an i3 UIO8 LAN Inputs and Output Peripheral Device.
UIO8 has been designed to support two different functions: a single-reader card access
controller board or a universal I/O controller with 4 inputs & 4 outputs.
When used as an I/O Contoller device, i3’s UI08 may be integrated with the i3’s SRX-
Pro DVR/NVR system via LAN. SRX-Pro Server will detect and connect to all UIO8 devices
connected to Local Area Network. Each UIO8 device supports 4 inputs and 4 outputs and
can control PTZ cameras through the TCP/IP (network). SRX-Pro Server can connect to
a total of 16 individual UIO8 devices supporting up to a maximum of 64 inputs and 64
outputs.
UIO8 can be powered with a 24~36VAC power source or via PoE Switch on the
network. UIO8 device, in turn, offers a 12VDC output, to power other connected devices
such as strobe light, buzzer, alarm etc., making for a more convenient and cost-efficient
installation. UIO8 may also be integrated with i3’s CMS sensor input, which adds further
reporting and monitoring capabilities to i3 International’s CMS Site Info module and Alert
Centre application.
If the system needs to be modified or repaired, contact a certified i3 International
Dealer/Installer. When serviced by unauthorized technician, the system warranty will be
voided. Should you have any problems or questions regarding our products, contact your
local Dealer/Installer.
Precautions
Installation and serving should be performed only by qualified and experienced technicians
to conform to all local codes and to maintain your warranty.
When installing your UIO8 device be sure to avoid:
• excessive heat, such as direct sunlight or heating appliances
• contaminants such as dust and smoke
• strong magnetic fields
• sources of powerful electromagnetic radiation such as radios or TV transmitters
• moisture and humidity
Default Connection Information
Reset
Device
Sensor Input5VDCControl Output12VDC Reader (Wiegand)
Wiring Diagram
Changing IP Address in ACT
UIO8 devices cannot share an IP address, each UIO8 requires its own unique IP address.
1. Connect your UIO8 device to the Gigabit switch.
2. On your i3 NVR, launch i3 Annexxus Configuration Tool (ACT) v.1.5 or higher.
You can download and install the latest ACT installation package from i3 website:
https://i3international.com/download
LED Status
A control joystick, LCD, and keys are on the front panel of the control keyboard. The LCD
displays system status and operation information and the joystick controls the panel for
4-directional (Up, Down, Left, and Right) speed movement and manual positioning.
• Power LED (Green LED): indicates power connection to the board
• RS485 TX-RX: indicates signal transmission to and from connected devices
• Portal / IO (Blue LED): indicates current function of the UIO8 board.
Blue LED On - Portal Card Access; Blue LED Off - IO Control
• ENET (Green LED): blinking LED indicates the health of the UIO8 device
• Firmware (Orange LED): blinking LED indicates firmware upgrade in progress.
UIO8 default IP address is 192.0.0.10
UIO8 default subnet mask address is 255.255.255.0
Default UIO8 Control Port: 230. Default HTTP Port: 80.
Firmware Version Default Login Default Password
v.2.3.2, and below i3international uio8
v.2.3.3, or higher i3admin i3admin
3. Select “ANNEXXUS UIO8” in the model drop-down menu to show only the UIO8
devices in the list.
4. Enter the new IP address and Subnet Mask of the camera in the Device(s)
Communication Update area.
5. Click Update and then Yes in the confirmation window.
Tip: New IP address must match the IP range of LAN or NVR’s NIC1.
6. Wait a few moments for a “Success” message in the Result field.
Repeat Steps 1-5 for all detected UIO8 devices OR
7. Assign IP range to multiple cameras by selecting two or more UIO8 in ACT, then
entering the starting IP address and the final IP octet for your IP range.
Click Update and then Yes in the confirmation window.
Wait until “Success” message is shown for all selected UIO8.

USER MANUAL UIO8 Input/Output Device
i3 INTERNATIONAL INC. Tel: 1.866.840.0004
www.i3international.com
SRX-Pro Server Setup & Configuration
Adding UIO8 device to SRX-Pro v6
1. Login into your SRX-Pro Server, open SRX-Pro Console and go to Setup > Hardware
setup tab.
2. Select Controls or Sensors tab and click Search UIO8.
3. In the Add Available UIO8 Devices window, all UIO8 devices on the network will be
detected and displayed. Select the desired UIO8 device.
In this example, UIO8 device with the IP Address 192.0.0.13 has been selected.
Note: Default UIO8 Control Port number: 230. Default HTTP Port: 80.
To edit UIO8 IP Address, or Ports, select the device in the list, click Edit, and enter
new IP/Port information. When done, click Update. Alternatively, use ACT (Annexxus
Configuration Tool).
4. Four (4) Control Outputs and four (4) Sensor Inputs from selected UIO8 device will
be added to the Hardware setup page. Configure settings for connected sensors and
controls and click the Save button .
Turning UIO8 Controls ON/OFF in SRX-Pro Console
Turn UIO8 controls ON/OFF from the Advanced or Tree view control panel by clicking
on the corresponding control button/name.
To enable Advanced or Tree view, go to View > Advanced View / Tree View.
Note that in Advanced View, controls are shown sequentially without displaying
which device they belong to. Consult Hardware Setup tab to match Control ID to the
Control number in the Advanced View panel.
Tree View Advanced View
PTZ Configuration
1. In the Hardware Setup tab, select the PTZ camera video input from the Video
drop-down menu.
2. Enter the Camera ID number that has been configured on that PTZ camera
3. Select the appropriate PTZ Camera Type in the corresponding drop-down menu.
In this example, PELCO-D-Mini protocol has been assigned to Channel 1, with
Cam. ID “1”.
4. Click the Save button.
5. Click the Live Mode button to return to the live view mode and click on
the channel that has been associated with the PTZ camera connected to the
UIO8 device. The selected channel will be displayed in the Full Screen mode and
the PTZ Advanced Control panel will be displayed on the left-hand side (Tree or
Advanced View only).
6. Use the Advanced Control PTZ interface to control the PTZ camera.
Click this
header to
expand PTZ
panel.
Click the arrows to
Pan and Tilt.
Switch between High
Res (Main) and Low
Res (Sub) camera
video streams.
Adjust the slider to
increase/decrease the
Pan/Tilt/Zoom speed.
Click to open Preset
Touring Manager win-
dow to create/manage
camera preset touring.
Click Zoom
In/Zoom Out
buttons to
adjust camera
zoom
Select Camera Preset
from the drop-down
menu to re-position
the camera. Right-click
inside Presets menu
and click Create Preset
to save camera’s
current position.
Hard Factory Default Reset
(Internal dip-switch panel)
To reset the UIO8 device to the factory defaults (see Default Connection Information
section),
1. Open the device cover with a Philips screw driver.
2. Ground yourself and wear appropriate ESD protective gear before touching the inside
of the unit to avoid electrostatic discharge that may permanently damage the unit.
3. Locate the 8-dip switch panel in the bottom right-hand corner of the device.
All 8 dip switches are in the OFF position by default.
4. Locate Dip switch number “7”. Turn dip switch 7 ON, then back to its default OFF
position to return the device to factory defaults settings.
5. Replace the unit cover and secure it with 2 screws.

USER MANUAL UIO8 Input/Output Device
i3 INTERNATIONAL INC. 1.866.840.0004
www.i3international.com
Visit our YouTube channel for training videos.
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
Adding UIO8 device to SRX-Pro v7
1. Launch the i3 Pro Setup from the Desktop or from the SRX-Pro Monitor.
2. In the IE browser, click Continue to this website.
3. Enter your administrator Username and Password and click LOGIN .
Tip: default administrative login is i3admin.
4. Click on the Server tile > I/O devices > Controls (0) or Sensors (0) tab
5. Click SEARCH UIO8 button.
6. All UIO8 devices on the network will be detected and displayed. Select the desired
UIO8 device(s) and click ADD.
In this example, UIO8 device with the IP Address 192.0.0.108 has been selected.
Note: Default UIO8 Control Port number: 230. Default HTTP Port: 80.
7. Four (4) Control Outputs and four (4) Sensor Inputs from each selected UIO8 device
will be added to I/O devices tab.
8. Configure settings for connected controls and sensors and click Save.
Turning UIO8 Controls ON/OFF in Video Pilot Client (VPC)
To turn the Control outputs ON/OFF remotely, launch Video Pilot Client software.
Connect to the localhost server if running VPC on the same NVR.
Otherwise, add new server connection and click Connect.
In LIVE mode, hover the mouse over the bottom of the screen to reveal the Sensor/
Control menu panel.
Turn individual controls ON and OFF by clicking on the corresponding control button.
Hover over the Control button to see the Control custom name.
All Controls are OFF
Controls 1,2 are ON; Controls 3,4 are OFF.
Troubleshooting
Q: Some UIO8 devices cannot be found in SRX-Pro.
A: Make sure each UIO8 device has a unique IP address. Use Annexxus Configuration
Tool (ACT) to change IP address for all UIO8 devices.
Q: Unable to add UIO8 to SRX-Pro.
A: UIO8 device can be used by a single application/service at-a-time.
Example: If i3Ai Server is using UIO8 device, then SRX-Pro running on the same
NVR will not be able to add the same UIO8 device. Remove the UIO8 from the other
application before adding to SRX-Pro.
In SRX-Pro v6, UIO8 devices already in use by another application/service will show
up in red. In this example, UIO8 with the IP address 10.1.5.29 is currently in use by
another application or service and cannot be added.
In SRX-Pro v7, UI08 devices already in use by another application/service will be
grayed out. The IP of the device running the application currently using the specific
UIO8 device will be visible in Used by column.
In this example, UIO8 with the IP address 102.0.0.108 is grayed out and cannot be
added as it’s currently in use by the application running on the device with the IP
address 192.0.0.252.
Popular I/O System manuals by other brands

National Instruments
National Instruments SC Express Series user manual

National Instruments
National Instruments USB-7855 Getting started guide

National Instruments
National Instruments NI 6581 Getting started guide

Siemens
Siemens SIMATIC ET 200AL manual

Unitronics
Unitronics EX-D16A3-TO16 installation guide

Joy-it
Joy-it MotoDriver2 manual