EM-5166 Rev.1 P. 1 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTRUCTION MANUAL
Mini-M™
PULSE DIVIDER MODEL M2PDU
BEFORE USE ....
Thank you for choosing us. Before use, please check con-
tents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact our sales office or representatives.
■PACKAGE INCLUDES:
Signal conditioner (body + base socket).............................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
85 – 264V AC rating: 85 – 264V, 47 – 66 Hz, approx. 4 - 6 VA
24V DC rating: 24V ±10%, approx. 2 W
11 – 27V DC rating: 11 – 27V, approx. 2 W
110V DC rating: 85 – 150V, approx. 2 W
■GENERAL PRECAUTIONS
• Before you remove the unit from its base socket or mount
it, turn off the power supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
• Be sure that the ventilation slits are not covered with ca-
bles, etc.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
• With voltage output, do not leave the output terminals
shortcircuited for a long time. The unit is designed to
endure it without breakdown, however, it may shorten ap-
propriate life duration.
COMPONENT IDENTIFICATION
Model
Body Base Socket
Connection
Diagram
Specifications
Fixing Screw
M2PDU
EM-5166 Rev.1 P. 2 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INSTALLATION
Loosen the fixing screw at the front of the unit in order to
separate the body from the base socket.
DIN Rail
35mm wide
Spring Loaded
DIN Rail Adaptor
■DIN RAIL MOUNTING
Set the base socket so that
its DIN rail adaptor is at
the bottom. Position the
upper hook at the rear side
of base socket on the DIN
rail and push in the lower.
When removing the socket,
push down the DIN rail
adaptor utilizing a minus
screwdriver and pull.
■WALL MOUNTING
Refer to “EXTERNAL DIMENSIONS.”
COMPONENT IDENTIFICATION
Setting SW A
Setting SW B
Setting SW C
Division Ratio Setting
Rotary SW
Setting SW D
■FRONT VIEW
Division Ratio
In the range of 1/1 to 1/6400, division ratio can be set arbi-
trarily with the following combinations of the switches.
Switch No. Switch A Switch B Switch C Switch D
1 No divi-
sion
No divi-
sion
No divi-
sion
No divi-
sion
2 1/2 1/16 1/128 1/5
3 1/4 1/32 1/256 1/25
4 1/8 1/64 - -
Note 1. Set two switches out of A through C to "no division".
(Settings such as 1/2 for switch A and 1/16 for switch B
are disabled. )
Note 2. 1/5 and 1/25 are not settable.
Be sure to set Switch A through C when setting Switch
D to 1/5 or 1/25.
Division setting list
(*) factory default setting
Division
ratio Switch A Switch B Switch C Switch D
No division (*)
1111
1/2 2 1 1 1
1/4 3 1 1 1
1/8 4 1 1 1
1/10 2 1 1 2
1/16 1 2 1 1
1/20 3 1 1 2
1/32 1 3 1 1
1/40 4 1 1 2
1/50 2 1 1 3
1/64 1 4 1 1
1/80 1 2 1 2
1/100 3 1 1 3
1/128 1 1 2 1
1/160 1 3 1 2
1/200 4 1 1 3
1/256 1 1 3 1
1/320 1 4 1 2
1/400 1 2 1 3
1/640 1 1 2 2
1/800 1 3 1 3
1/1280 1 1 3 2
1/1600 1 4 1 3
1/3200 1 1 2 3
1/6400 1 1 3 3
M2PDU
EM-5166 Rev.1 P. 3 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit.
■EXTERNAL DIMENSIONS unit: mm [inch]
5
9
21.5 [.85]
70.5 [2.78]
86.7 [3.41]7.3 [.29] 15 [.59]
6 [.23]
59 [2.32]
DIN RAIL
35mm wide
(4 [.16])
8–M3
SCREW
72 [2.83]
23 [.91]
2–4.2x5
[.17x.20]
MTG HOLE
6 [.24] deep
116.7 [4.59]
• When mounting, no extra space is needed between units.
14
8
12
14 13
4 [.16]
■CONNECTION DIAGRAM
4kΩ
■ Mechanical Contact, Open Collector
or Clamp-on Pulse Sensor CLSP
Input Connection Examples
+12V
■ Voltage Pulse
+12V
■ Open Collector
Output Connection Examples
+
–
9
12
+
–
■ Voltage Pulse
+
–
9
12
+
–
+
+
–
–
PWR
+
+
–
–
PWR
+
–
1
4
+5
+
–
1
4
+5
+
–
OUTPUT
9
12
U(+)
V(–)
POWER
13
14
+
–
INPUT
1
5
4
+
SENSOR EXCITATION
M2PDU
EM-5166 Rev.1 P. 4 / 4
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
■SOLDERLESS TERMINAL
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable.
Applicable wire size: 0.25 to 1.65 mm2(AWG 22 to 16)
Recommended manufacturer: Japan Solderless Terminal
MFG.Co.Ltd, Nichifu Co.,ltd
6 (.24) max
3.3 (.13) max
mm (inch)
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage across the terminal
13 – 14 with a multimeter.
3) Input: Check that the input frequency is 30 Hz or less for
relay contact, 100 kHz or less for other types of input.
Check also that the input pulse is of 10 msec. or wider for
relay contact, 5 µsec. or wider for other types of input.
4) Output: Check that the load resistance meets the de-
scribed specifications as shown below.
OUTPUT LOAD REQUIREMENTS
Open collector 50V DC @ 100mA max.
Voltage pulse
250Ω min. for 5V
600Ω min. for 12V
1200Ω min. for 24V
LIGHTNING SURGE PROTECTION
We offer a series of lightning surge protector for protec-
tion against induced lightning surges. Please contact us to
choose appropriate models.

Other MG I/O System manuals

MG R6N-SS2 User manual

MG

MG R6N-SS2 User manual

MG R8-FS16N User manual

MG

MG R8-FS16N User manual

MG R7F4HD-DA32B User manual

MG

MG R7F4HD-DA32B User manual

MG 10FNS User manual

MG

MG 10FNS User manual

MG R1M-J3 User manual

MG

MG R1M-J3 User manual

MG R7HL-YS4L User manual

MG

MG R7HL-YS4L User manual

MG R3Y-MS8 User manual

MG

MG R3Y-MS8 User manual

MG R9WTU-ED User manual

MG

MG R9WTU-ED User manual

MG M2BS-16U0 User manual

MG

MG M2BS-16U0 User manual

MG R1M-GH User manual

MG

MG R1M-GH User manual

MG R7F4HD-DAC32D User manual

MG

MG R7F4HD-DAC32D User manual

MG R5-DS1A User manual

MG

MG R5-DS1A User manual

MG R7G4FML3-6-DC16A User manual

MG

MG R7G4FML3-6-DC16A User manual

MG M6DYV User manual

MG

MG M6DYV User manual

MG 10YS User manual

MG

MG 10YS User manual

MG Devicenet R7F4DD-DC16A-C User manual

MG

MG Devicenet R7F4DD-DC16A-C User manual

MG R30BS User manual

MG

MG R30BS User manual

MG R7F4HEIP-DA16A User manual

MG

MG R7F4HEIP-DA16A User manual

MG R7E-MS4 User manual

MG

MG R7E-MS4 User manual

MG R7F4HC-DA32-K User manual

MG

MG R7F4HC-DA32-K User manual

MG R6N-SV2 User manual

MG

MG R6N-SV2 User manual

MG R5-SV1A User manual

MG

MG R5-SV1A User manual

MG R7C-RT4A User manual

MG

MG R7C-RT4A User manual

MG M6DBS User manual

MG

MG M6DBS User manual

Popular I/O System manuals by other brands

M-system R7ML-DA16 instruction manual

M-system

M-system R7ML-DA16 instruction manual

Siemens SIMATIC ET 200iS manual

Siemens

Siemens SIMATIC ET 200iS manual

GE VersaPoint IC220ALG221 System manual

GE

GE VersaPoint IC220ALG221 System manual

CREVIS FnIO SSeries Quick start manual

CREVIS

CREVIS FnIO SSeries Quick start manual

Profire Energy PF2100 user manual

Profire Energy

Profire Energy PF2100 user manual

Crestron DMB-4K-CPU-128 Installation guides

Crestron

Crestron DMB-4K-CPU-128 Installation guides

Allen-Bradley Compact 5000 Series user manual

Allen-Bradley

Allen-Bradley Compact 5000 Series user manual

ICP DAS USA P8R8-DIO quick start guide

ICP DAS USA

ICP DAS USA P8R8-DIO quick start guide

Allen-Bradley ArmorBlock-LP 1792-IB16LP installation instructions

Allen-Bradley

Allen-Bradley ArmorBlock-LP 1792-IB16LP installation instructions

Extron electronics TLP VIM user guide

Extron electronics

Extron electronics TLP VIM user guide

National Instruments NI PXI-665 Series CALIBRATION PROCEDURE

National Instruments

National Instruments NI PXI-665 Series CALIBRATION PROCEDURE

ETAS ES930.1 user guide

ETAS

ETAS ES930.1 user guide

Measurement Computing USB-3103 user guide

Measurement Computing

Measurement Computing USB-3103 user guide

SeaLevel SeaRAQ 6510 user manual

SeaLevel

SeaLevel SeaRAQ 6510 user manual

EverFocus External I/O Box quick start guide

EverFocus

EverFocus External I/O Box quick start guide

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

Advantech B+B SmartWorx Zlinx ZZ24D-NA-SR quick start guide

Advantech

Advantech B+B SmartWorx Zlinx ZZ24D-NA-SR quick start guide

Future Desion Controls FDC-VR18 quick start guide

Future Desion Controls

Future Desion Controls FDC-VR18 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.