ICO CCD-800 User manual

CONTENTS
Getting Started -----------------------------------------------------------------------
2
Setup Procedures ---------------------------------------------------------------------
3
Setup Menu-------------------------------------------------------------------------------
4
Setup flow Chart ------------------------------------------------------------------------
4
Group 0 : Interface Selection -------------------------------------------------------
5
Group 1 : Device Selection for keyboard interface--------------------------
6-7
Group 2 : Inter-character Delay ---------------------------------------------------
8
Group 3 : Language for Keyboard Interface ------------------------------------------
9-10
Group 4 : Terminator---------------------------------------------------------------
11-12
Group 5 : Scan Mode ----------------------------------------------------------
13-14
Group 6 : Preamble and Postamble -------------------------------------------------
15
Group 7 : Reserved --------------------------------------------------------------------------
15
Group 8 : RS-232 Parameters --------------------------------------------------
16-18
Group 9 : Code 39 / Code 32 ---------------------------------------------------
19-20
Group 10-1: Interleaved 2 of 5 ------------------------------------------------------
21
Group 10-2: Industrial 2 of 5 / IATA------------------------------------------
22
Group 10-3: Matrix 2 of 5----------------------------------------------------------
23
Group 10-4: China Postage-------------------------------------------------------
24
Group 11 : Code 128/ Code 93/ Code 11/ MSI-PLESSEY-----------
25-26
Group 12 : ISBN/ISSN-------------------------------------------------------------
27
Group 13 : Codabar / NW7---------------------------------------------------------
28
Group 14 : Code 4--------------------------------------------------------------------
29
Group 15-1 : EAN 13 / JAN 13-------------------------------------------------------
30
Group 15-2 : UPC-A-------------------------------------------------------------
31
Group 15-3 : EAN-8 / JAN-8-----------------------------------------------------------
32
Group 15-4 : UPC-E / UCC EAN-128-----------------------------------------------
33
Group 16 : General Parameters-------------------------------------------------------
34
Group 17 : Code ID Settings---------------------------------------------------------
35
Group 18 : Wand Type Parameters-------------------------------------------------
36
Group 19 : Magnetic Parameters---------------------------------------------------
37-39
Group 20 : Function Key Emulation----------------------------------------------
40
Function Code for PC XT/AT------------------------------------------------------
41-42
Table-Hex : Hexadecimal---------------------------------------------------------
43
ASCII Table----------------------------------------------------------------------------
44
Hexadecimal-Decimal Conversion Table -------------------------------------------
45
Pin Assignments of Scanners-----------------------------------------------------
46-47
1

Getting Started
Installing Keyboard Wedge Scanner
To install a keyboard wedge scanner, follow the steps listed below:
1) Make sure that the scanner has the correct Y (U)- cable for the system (a PC or terminal)
2) Turn off the power of the system
3) Unplug the keyboard from the system
4) Connect the Y (U)- cable to the system and keyboard
5) Turn on the power of the system
6) If the indicator LED lights up and the buzzer sounds, the scanner is ready for reading
Installing a RS-232 Interface Scanner
To install a RS-232 interface scanner, the host device should have a RS-232 port to
receive data from the scanner, follow the steps listed below:
1) Make sure that the scanner has the right connector for the RS-232 port of the host device
2) Make sure that there is a power supply to the scanner (if necessary)
3) Connect the cable to the RS-232 port of the device
4) If the indicator LED lights up and the buzzer sounds, the scanner is ready for reading
2

Setup Procedures
1) Locate a group that contains the parameters to be changed.
2) Scan the “Enter Group #” label. The scanner will sound beeps indicate that setup is in progress
3) Scan the label representing the parameter to be changed
4) Scan the “Exit” to end the group currently selected, the scanner will sound beeps.
5) Repeat the procedure for other groups including the parameters to be changed
Example 1:
Set the operating mode to “Continuous mode”
1) Scan “Enter Group 5”
2) Scan “Continuous/Trigger off”
3) Scan “Exit”
Example 2
Assign Preamble string as “#”, and postamble string as “END”
1) Scan “Enter Group 6”
2) Scan Preamble”
3) Scan “#” from “Full ASCII Table and Table-Hex.”
4) Scan “Confirm” Label in Table-Hex
5) Scan “Postamble”
6) Scan “E”, “N”, “D” from “Full ASCII Table and Table Hex” consecutively
7) Scan “Confirm” Label in Table-Hex.
8) Scan Exit
3

Setup Flow Chart
Set All Defaults
Show Version
ENTER GROUP
SELECT ITEMS
EXIT
4

Group 0: Interface Selection
KEYBOARD
RS-232
WAND
OCIA
RS-232
Reserved 2
DTMF
Reserved 4
ENTER GROUP
EXIT
5

Group 1: Device Selection for Keyboard Interface
PC/AT, PS/2 50,60,70,80(*)
PC/XT
PS/2 25, 30
(NEC 9801)
(IBM 5550)
(PS 55)
(NEC N5520)
(ACER 7300)
(KW1050D/CT-700A/WANG 5120)
(WANG 5425)
(MAC_SE)
(LC-6533)
ENTER GROUP
EXIT
6

Group 1: Device Selection for Keyboard Interface
(IBM3196,3197,3476,3477)
Reserved Q
Reserved R
Reserved T
IBM3197
IBM 3476
IBM3477
RESERVED 5
Reserved 6
RESERVED 7
Reserved 8
RESERVED 9
ENTER GROUP
EXIT
7

Group 2: Intercharacter Delay
Start Keyboard Setting
Scan Enter Group 2 Label -- >
Scan Start Keyboard (or RS-232) Setting Label -->
Scan two digits labels in "Table-Hex" -->
Scan Exit Label
Start RS-232 Setting
Keyboard Default Value: 05
RS-232 Default Value : 00
ENTER GROUP
EXIT
8

Group 3: Language for Keyboard Interface
U.S. (*)
ENGLAND
FRANCE
GERMANY
ITALY
BELGIUM
SWEDEN/FINLAND
SPANISH
DENMARK
PORTUGAL
SWISS
NORWAY
ENTER GROUP
EXIT
9

Group 3: Language for Keyboard Interface
CANADA
HOLLAND
POLAND
LATIN
JAPAN
RESERVED 1
RESERVED 2
RESERVED 3
(IBM THINK-PAD FOR JAPAN)
(PANASONIC CF-II FOR JAPAN)
ENTER GROUP
EXIT
10

Group 4: Terminator
KEYBOARD
NONE
CR
SPACE
TAB
ESC
CTRL-C
ESC
ENTER GROUP
EXIT
11

Group 4: Terminator
RS-232
NONE
CR
CR/LF
LF
SPACE
TAB
ESC
CTRL-C
STX..ETX
XON.. XOFF
EOT
ENTER GROUP
EXIT
12

Group 5: Scan Mode
1: Trigger On/Off
2: Trigger On/Good Read Off (*)
3: Trigger On/Good Read Off/
Delay Timeout = ?
4: Continuous/Trigger Off
5: Continuous/LED Always on
6: Continuous/No Trigger
7: Continuous/Testing
8: Continuous/Trigger Off/
Delay Timeout = ?
ENTER GROUP
EXIT
13

Group 5: Scan Mode
FLASH OFF(*)
FLASH ON
SHORT ZONE
LONG ZONE
LASER DELAY
For Laser Scanner Mode
Default Laser Delay Timeout = 60 sec.
Scan Enter Group 5 Label
Scan Laser Delay -->
Refer to the Table-Hex at page 41 and select a value -->
Scan Confirm in Table Hex.
Scan Exit Label
LAG-960TR - Auto Trigger mode
AUTO TRIGGER
Scan Enter Group 5 Label -->
Scan 8: Continuous/Trigger off/Delay timeout=? (Page 13) -->
Scan two digit label and "confirm" label in Page 43 -->
Scan Above "Auto Trigger Label)
Switch on the LAG-960 bottom switch
Note: Scan mode setting is only available for CCD/Laser type scanner.
ENTER GROUP
EXIT
14

Group 6: Preamble and Postamble
Preamble
Postamble
Preamble & Postamble Setting:
Scan Enter Group 6 Label -->
Scan Preamble or Postamble Label -->
Refer to ASCII Table(page 44), scan two digits in Table-Hex (Page 43)
Representing one character, maximum 10 characters can be accepted. -->
Scan Confirm Label in Table-Hex (Page 43)
Scan Exit Label
Clear
Clear Preamble & Postamble :
Scan Enter Group 6 Label -->
Scan Preamble or Postamble Label -->
Scan "Clear" Label-->
Scan "Exit" Label
ENTER GROUP
EXIT
15

Group 8: RS-232 Parameters
Baud Rate
300
600
1200
2400
4800
9600(*)
19200
38400
Data Bit
BIT 7
BIT 8
ENTER GROUP
EXIT
16

Group 8: RS-232 Parameters
Parity :
NONE (*)
ODD
EVEN
Handshaking:
NONE (*)
XON/OFF
Scanner Ready
Data Ready
ACK/NAK
ENTER GROUP
EXIT
17

Group 8: RS-232 Parameters
(CK/NAK Response Time
CTS Observation Time:)
100 ms
300 ms
500 ms
1 sec.
3 sec (*)
5 sec.
10 sec.
00
ENTER GROUP
EXIT
18

Group 9: CODE 39 / (CODE 32)
Enable (*)
Disable
Standard (*)
Full ASCII
Transmit Start/End Character
Disable (*)
Enable
Transmit Check Character
Enable (*)
Disable
Verify Checksum
Enable
Disable (*)
Enable CODE 32
ENTER GROUP
EXIT
19

Group 9: CODE 39 / (CODE 32)
Verify Normal (*)
Verify Strick
ENTER GROUP
EXIT
20
Table of contents
Other ICO Barcode Reader manuals