IEI Technology AUPS Series User manual

AUPS Series Power Module User Manual
Page i
User Manual
Model:
AUPS Series
VESA Mount Intelligent UPS Module
12 V DC Input or 9 V–36 V DC Input
Network Remote Management Support
Rev. 2.00 – July 3, 2018

AUPS Series Power Module User Manual
Page ii
Revision
Date Version Changes
July 3, 2018 2.00 Updated for R20 version:
-Battery Specifications
-Chapter 4: Software Application
May 7, 2014 1.01 Added Appendix A: Safety Precautions
November 12, 2008 1.00 Initial release

AUPS Series Power Module User Manual
Page iii
Copyright
COPYRIGHT NOTICE
The information in this document is subject to change without prior notice in order to
improve reliability, design and function and does not represent a commitment on the part
of the manufacturer.
In no event will the manufacturer be liable for direct, indirect, special, incidental, or
consequential damages arising out of the use or inability to use the product or
documentation, even if advised of the possibility of such damages.
This document contains proprietary information protected by copyright. All rights are
reserved. No part of this manual may be reproduced by any mechanical, electronic, or
other means in any form without prior written permission of the manufacturer.
TRADEMARKS
All registered trademarks and product names mentioned herein are used for identification
purposes only and may be trademarks and/or registered trademarks of their respective
owners.

AUPS Series Power Module User Manual
Page iv
Manual Conventions
WARNING
Warnings appear where overlooked details may cause damage to the
equipment or result in personal injury. Warnings should be taken
seriously.
CAUTION
Cautionary messages should be heeded to help reduce the chance of
losing data or damaging the product.
NOTE
These messages inform the reader of essential but non-critical
information. These messages should be read carefully as any directions
or instructions contained therein can help avoid making mistakes.
HOT SURFACE
This symbol indicates a hot surface that should not be touched without
taking care.

AUPS Series Power Module User Manual
Page v
Table of Contents
1 INTRODUCTION.......................................................................................................... 1
1.1AUPS SERIES OVERVIEW........................................................................................... 2
1.2AUPS SERIES UPS MODULE FEATURES..................................................................... 2
1.3 EXTERNAL OVERVIEW................................................................................................ 3
1.3.1 I/O interface panel (Standard)........................................................................... 3
1.3.1.1 AUPS-A10 Power Input Connector............................................................ 4
1.3.1.2 AUPS-A20 Power Input Connectors .......................................................... 4
1.3.1.3 AUPS-B10 Power Input Connector............................................................ 5
1.3.1.4 AUPS-B20 Power Input Connectors........................................................... 5
1.3.2 LED Indicators................................................................................................... 6
1.4AUPS SERIES SPECIFICATIONS................................................................................... 7
1.5 BATTERY SPECIFICATIONS .......................................................................................... 8
1.5.1 AUPS-A10/AUPS-A20 Battery........................................................................... 8
1.5.2 AUPS-B10/AUPS-B20 Battery......................................................................... 10
1.6AUPS SERIES DIMENSIONS...................................................................................... 12
1.6.1 AUPS-A10/AUPS-A20 Dimensions.................................................................. 12
1.6.2 AUPS-B10/AUPS-B20 Dimensions.................................................................. 13
2 UNPACKING............................................................................................................... 14
2.1ANTI-STATIC PRECAUTIONS...................................................................................... 15
2.2 UNPACKING.............................................................................................................. 15
2.2.1 Unpacking Precautions.................................................................................... 15
2.3 UNPACKING CHECKLIST........................................................................................... 16
2.3.1 Package Contents............................................................................................. 16
3 INSTALLATION ......................................................................................................... 18
3.1ANTI-STATIC PRECAUTIONS...................................................................................... 19
3.2 INSTALLATION PRECAUTIONS................................................................................... 19
3.3 INSTALLATION AND CONFIGURATION STEPS ............................................................. 20
3.4 BATTERY PACK INSTALLATION ................................................................................. 20
3.5 MOUNTING THE AUPS SERIES ................................................................................. 21

AUPS Series Power Module User Manual
Page vi
3.6 CONNECTING THE AUPS SERIES.............................................................................. 23
4 SOFTWARE APPLICATION..................................................................................... 24
4.1 INTRODUCTION......................................................................................................... 25
4.2 DRIVER INSTALLATION............................................................................................. 25
4.3APPLICATION INSTALLATION .................................................................................... 29
4.4 MONITORING DC POWER AND SMART BATTERY ...................................................... 31
4.4.1 Status Information............................................................................................ 31
4.4.1.1 DC Power Status....................................................................................... 31
4.4.1.2 Battery Status............................................................................................ 32
4.4.2 Battery Information.......................................................................................... 33
4.4.3 LAN Setting...................................................................................................... 34
4.4.3.1 Using Static IP .......................................................................................... 35
4.4.4 Setting .............................................................................................................. 36
4.4.5 E-mail............................................................................................................... 37
4.5 REMOTE CONTROLAND MONITORING...................................................................... 38
A SAFETY PRECAUTIONS......................................................................................... 43
B HAZARDOUS MATERIALS DISCLOSURE ......................................................... 49

AUPS Series Power Module User Manual
Page vii
List of Figures
Figure 1-1: AUPS Series UPS Module ..........................................................................................2
Figure 1-2: AUPS Series Standard I/O Interface Connectors.....................................................3
Figure 1-3: AUPS-A10 Power Input Connector............................................................................4
Figure 1-4: AUPS-A20 Power Input Connectors..........................................................................4
Figure 1-5: AUPS-B10 Power Input Connector............................................................................5
Figure 1-6: AUPS-B20 Power Input Connectors..........................................................................5
Figure 1-7: AUPS Series LED Indicators......................................................................................6
Figure 1-8: AUPS-A10/A20 Dimensions (mm) ...........................................................................12
Figure 1-9: AUPS-B10/B20 Dimensions (mm) ...........................................................................13
Figure 3-1: Top Cover Retention Screws (Rear Panel).............................................................20
Figure 3-2: Top Cover Retention Screws (Top Panel) ..............................................................21
Figure 3-3: Battery Pack Installation ..........................................................................................21
Figure 3-4: Mounting Bracket Installation..................................................................................22
Figure 3-5: Mounting the AUPS Series.......................................................................................22
Figure 3-6: AUPS Series and Panel PC Connection .................................................................23
Figure 4-1: Preparing Setup Screen ...........................................................................................25
Figure 4-2: Driver Welcome Screen............................................................................................26
Figure 4-3: Driver License Agreement Screen ..........................................................................26
Figure 4-4: Choose Destination Location ..................................................................................27
Figure 4-5: Ready to Install the Driver........................................................................................27
Figure 4-6: InstallShield Wizard Complete Screen....................................................................28
Figure 4-7: CP210x USB to UART Bridge Driver Installer ........................................................28
Figure 4-8: Installation Complete................................................................................................28
Figure 4-9: Welcome Screen .......................................................................................................29
Figure 4-10: Installation Complete..............................................................................................30
Figure 4-11: IEI AUPS Application Overview.............................................................................30
Figure 4-12: Status Information ..................................................................................................31
Figure 4-13: DC Detection............................................................................................................31
Figure 4-14: Battery Information.................................................................................................33
Figure 4-15: LAN Setting..............................................................................................................34

AUPS Series Power Module User Manual
Page viii
Figure 4-16: LAN Setting – Disable DHCP .................................................................................35
Figure 4-17: Application Setting .................................................................................................36
Figure 4-18: E-mail Setting ..........................................................................................................37
Figure 4-19: RJ-45 Remote LAN Connector...............................................................................38
Figure 4-20: Remote AP...............................................................................................................39
Figure 4-21: Remote AP – IP Address........................................................................................39
Figure 4-22: Remote Management Web Interface - Status.......................................................40
Figure 4-23: Remote Management Web Interface - Send Email ..............................................40
Figure 4-24: Enter User Name and Password............................................................................41
Figure 4-25: Remote Management Web Interface -Configuration........................................42

AUPS Series Power Module User Manual
Page ix
List of Tables
Table 1-1: LED Indicators ..............................................................................................................6
Table 1-2: AUPS Series Specifications.........................................................................................7
Table 1-3: AUPS-A10/AUPS-A20 Battery Specifications............................................................9
Table 1-4: AUPS-B10/AUPS-B20 Battery Specifications..........................................................11
Table 2-1: Package List Contents...............................................................................................17


AUPS Series Power Module User Manual
Page 1
Chapter
1
1 Introduction

AUPS Series Power Module User Manual
Page 2
1.1 AUPS Series Overview
Figure 1-1: AUPS Series UPS Module
The highly efficient, high-performance AUPS Series UPS (Uninterruptible Power Supply)
module installed with a Li-ion battery to provide stable 12 V output and uninterruptible
power to the IEI AFOLUX series panel PCs. The UPS module also receives either 12 V
input or a wide range of inputs between 6 V and 36 V DC. The AUPS Series is built on an
intelligent design and provides outstanding line and load regulations. The AUPS Series is
capable of providing power for certain of time in power failure.
The AUPS Series UPS module comes with the utility software that provides information on
current power source and battery status. With the AUPS software installed and network
connected, the AUPS Series can be monitored and turned on/off through a remote
computer.
1.2 AUPS Series UPS Module Features
Rugged metal enclosure for standard VESA75/100 mounting
Wide range power input (9 V–36 V) by DC jack or terminal block
Network management through web-based interface in remote computer. No
additional administration software installation is required.
Supports PC-based utility for monitoring power and battery status
Auto shut down when battery low
Provides stable power to AFOLUX PPC during line sags and spikes.
Absorb power surges and transients

AUPS Series Power Module User Manual
Page 3
1.3 External Overview
1.3.1 I/O interface panel (Standard)
The I/O interface panel of the AUPS Series (see Figure 1-2)has the following standard
I/O interface connectors:
1 x 12 V DC output jack
1 x USB mini-B connector
1 x Network remote management port (RJ-45)
1 x DC output switch terminal block
1 x DC on/off button
The standard external I/O interface connector panel is shown in Figure 1-2.
Figure 1-2: AUPS Series Standard I/O Interface Connectors

AUPS Series Power Module User Manual
Page 4
1.3.1.1 AUPS-A10 Power Input Connector
The AUPS-A10 has one power jack for +12 V DC input (Figure 1-3).
Figure 1-3: AUPS-A10 Power Input Connector
1.3.1.2 AUPS-A20 Power Input Connectors
The AUPS-A20 has one power jack and one terminal block for 9 V–36 V DC inputs
(Figure 1-4).
Figure 1-4: AUPS-A20 Power Input Connectors

AUPS Series Power Module User Manual
Page 5
1.3.1.3 AUPS-B10 Power Input Connector
The AUPS-B10 has one 4-pin power connector for +12 V DC input (Figure 1-5).
Figure 1-5: AUPS-B10 Power Input Connector
1.3.1.4 AUPS-B20 Power Input Connectors
The AUPS-B20 has one 4-pin power connector and one terminal block for 9 V–36 V DC
inputs (Figure 1-6).
Figure 1-6: AUPS-B20 Power Input Connectors

AUPS Series Power Module User Manual
Page 6
1.3.2 LED Indicators
The side panel of the AUPS Series has three LED indicators to indicate the power and
battery status (Figure 1-7).
Figure 1-7: AUPS Series LED Indicators
All the LED statuses are listed in Table 1-1.
Power Input LED Charger Status LED Battery Status LED
Color Green Yellow Orange
Off DC power out -- --
On DC power in Discharging (battery full) Battery discharging
Blinking -- Charging Battery low
Table 1-1: LED Indicators

AUPS Series Power Module User Manual
Page 7
1.4 AUPS Series Specifications
The AUPS Series UPS module technical specifications are listed in Table 1-2.
Model Name AUPS-A10 AUPS-A20 AUPS-B10 AUPS-B20
VESA Type VESA 75 mm x 75 mm VESA 75 mm x 75 mm
VESA 100 mm x 100 mm
Output Voltage +12 V +/-5% +12 V +/-5% +12 V +/-5% +12 V +/-5%
Power 60 W 60 W 100 W 100 W
Input Voltage +12 V +9 V ~ +36 V +12 V +9 V ~ +36 V
Battery Type Li-ion 2S2P Li-ion 2S2P Li-ion 4S2P Li-ion 4S2P
Nominal
Voltage
7.26 V
7.26 V
14.52 V
14.52 V
Nominal
Capacity
5200 mAh 5200 mAh 5200 mAh 5200 mAh
Physical Dimensions
(LxWxH)
150 x 95 x 34 (mm)
150 x 95 x 34 (mm)
170 x 150 x 34
(mm)
170 x 150 x 34
(mm)
Weight 1.2 kg 1.2 kg 1.8 kg 1.8 kg
LED Green DC power input DC power input DC power input DC power input
Yellow Battery charging Battery charging Battery charging Battery charging
Orange Battery discharging
Battery discharging
Battery discharging
Battery discharging
Temperature
Operating 0°C ~ 40°C 0°C ~ 40°C 0°C ~ 40°C 0°C ~ 40°C
Storage -20°C ~ 50°C -20°C ~ 50°C -20°C ~ 50°C -20°C ~ 50°C
Table 1-2: AUPS Series Specifications

AUPS Series Power Module User Manual
Page 8
1.5 Battery Specifications
The AUPS Series comes with a Li-ion smart battery. Some of the Li-ion battery
specifications are listed in the following tables.
1.5.1 AUPS-A10/AUPS-A20 Battery
Specifications Remarks
AUPS Model AUPS-A10/AUPS-A20 --
Battery Pack 4 cells 2S2P
Battery Type Li-ion --
Nominal Capacity 5200 mAh 0.5C charge/0.2C discharge at 25±3°
C,
cut off voltage at 2.75 V/cell
Minimum Capacity 5000 mAh 0.5C charge/0.2C discharge at 25±3°
C,
cut off voltage at 2.75 V/cell
Nominal Voltage 7.26 V 0.5C charge/0.2C discharge at 25±3°
C,
cut off voltage at 2.75 V/cell
End of Discharge Voltage 5.5 V FD set 5.5 V
Charge Voltage 0~10°C 11~45°C 46~60°C
Charging Voltage 8400 mV 8400 mV 8200 mV
Rated Charge Current 0~10°C 11~45°C 46~60°C
Per cell≦2.75V 510 mA 510 mA 510 mA
2.75V≦Per cell≦4.1V 1530 mA 2550 mA 2550 mA
4.1V≦Per cell≦4.2V 1530 mA 2550 mA 0 mA
Pre-charge Current 510 mA (cell < 2.75 V) Gas-gauge reports charge current as
510 mA
Max. Continuous Discharge
Power 50 W Environment temp.: 0~40°C
Discharge from 100% to 0%
Max. Continuous Discharg
e
Current 7.5 A Environment temp.: 0~40°C
Discharge from 100% to 0%

AUPS Series Power Module User Manual
Page 9
Max. Discharge Current 9.36 A Duration time < 5 sec.
Pack Operating Temp. 0~40°C Max. Humidity: 85% RH
Storage Temperature 1 year: -20°C ~ +25°C
3 months: -20°C ~ +45°C
1 month: -20°C ~ +65°C
During storage, pack must be charged
to 40%~50% every 3 months.
Protection
Over Voltage Protection Set: ≧4.24±0.02V / cell (0°C ~ 45°C), delay time: 2~4 sec.
Reset: <4.10±0.02V / cell
Under Voltage Protection Set: ≧2.55±0.02V / cell, delay time: 2~4 sec.
Reset:≧2.75±0.02V / cell
Cell Shutdown Voltage
Protection Cell ≦2.35V, delay time: 30 sec.
Over Discharge Current
Protection (SW)
Set: ≧10.04A, delay time 5~7 sec.
Reset: Current > -20mA, then 30 sec.
Over Discharge Current
Protection (AFE)
Set: 11.5~14.5A, typical 12.95A, delay time 31±4 mSec
Reset: after 30 sec, and then current < 5mA
Short-circuit Protection
Set: ≧30±20%A, delay time: 700uSec~1200uSec, typical 916uSec
Reset: after 30sec, and then current < 5mA
Over Charge Current
Protection
Set: ≧5.2A, delay time 2~4 sec.
Reset: Current < 20mA, then 30 sec.
Charge Over Temperature
Protection
Set: ≧60±3ºC, delay time: 2~4 sec
Reset: <45±3ºC
Discharge Over
Temperature Protection
Set: ≧70±3ºC, delay time: 2~4 sec
Reset: <60±3ºC
Table 1-3: AUPS-A10/AUPS-A20 Battery Specifications

AUPS Series Power Module User Manual
Page 10
1.5.2 AUPS-B10/AUPS-B20 Battery
Specifications Remarks
AUPS Model AUPS-B10/AUPS-B20 --
Battery Pack 8 cells 4S2P
Battery Type Li-ion --
Nominal Capacity 5200 mAh 0.5C charge/0.2C discharge at 25±3°
C,
cut off voltage at 2.75 V/cell
Minimum Capacity 5000 mAh 0.5C charge/0.2C discharge at 25±3°
C,
cut off voltage at 2.75 V/cell
Nominal Voltage 14.52 V 0.5C charge/0.2C discharge at 25±3°
C,
cut off voltage at 2.75 V/cell
End of Discharge Voltage 11 V FD set 11 V
Charge Voltage 0~10°C 11~45°C 46~60°C
Charging Voltage 16800 mV 16800 mV 16400 mV
Rated Charge Current 0~10°C 11~45°C 46~60°C
Per cell≦2.75V 510 mA 510 mA 510 mA
2.75V≦Per cell≦4.1V 1530 mA 2550 mA 2550 mA
4.1V≦Per cell≦4.2V 1530 mA 2550 mA 0 mA
Pre-charge Current 510 mA (cell < 2.75 V) Gas-gauge reports charge current as
510 mA
Max. Continuous Discharge
Power 100 W Environment temp.: 0~40°C
Discharge from 100% to 0%
Max. Continuous Discharg
e
Current 7.5 A Environment temp.: 0~40°C
Discharge from 100% to 0%
Max. Discharge Current 9.36 A Duration time < 5 sec.
Pack Operating Temp. 0~40°C Max. Humidity: 85% RH
Table of contents
Popular UPS manuals by other brands

INFOSEC UPS SYSTEM
INFOSEC UPS SYSTEM E7 One RT Series user manual

CyberPower
CyberPower CP900EPFCLCD user manual

Compaq
Compaq Presario 3000 Series Operation and reference guide

Emerson
Emerson Liebert APM 15-90kVA manual

Vertiv
Vertiv EDGE-750IMT Quick installation guide

Huawei
Huawei iBAT 2.0-CIM01C2 quick guide