manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ikan
  6. •
  7. Dj Equipment
  8. •
  9. Ikan LS-1812E User manual

Ikan LS-1812E User manual

CHECKED BY
LS-1812E
Quick Start Guide
18kW/12kW HMI Fresnel Kit (Lightstar)
What’s Included
1 x 18000/12000W HMI Fresnel Light
1 x 18000/12000 Watt Ballast
1 x 15-Meter Heavy Duty Head to Ballast Cable
1 x Gel Holder
1 x Barn Doors
1 x Yoke
www.ikancorp.com | 1.713.272.8822 | [email protected] because we’re filmmakers too
www.ikancorp.com | 1.713.272.8822 | [email protected] because we’re filmmakers too
Safety Precautions
• The LS-1812E fixture has been designed for professional use and must be operated by qualified personnel only.
• Electrical Connections: Do not attach the ballast directly to any electrical mains.
• The 18000/12000 Watt Electronic Ballast can only be used with a Lightstar 18kW watt or 12kW watt light fixture.
• Before connecting the electronic ballast to the power supply, make sure that the socket is correctly wired.
• Lamp head must be disconnected from the electronic ballast or electronic ballast must be disconnected from main power supply before fitting or
replacing a lamp or bulb.
• The electronic ballast must be switched off before connecting or disconnecting either head to ballast cable or power supply cable.
• The electronic ballast must be placed only on a solid, flat, and dry ground. Do NOT place the electronic ballast in direct sunlight. Do NOT operate the
electronic ballast in high humidity areas or near easily flammable materials.
Working Conditions
• The MAX ambient temperature limit is ±45°C (113°F)
• Please keep a minimum distance of 2 feet when close to inflammable objects.
• Do not cover the ventilation holes on the fixture housing. They are necessary for proper ventilation.
• Use only original parts and accessories from Lightstar.
• Before hanging the fixture, make sure the suspension points are properly rated to handle the weight of the fixture.
• It is ALWAYS advisable to add a safety cable or chain through the yoke to properly suspend the fixture in place.
WARNING: DO NOT USE THE FIXTURE IN A SPACE WITH FLAMMABLE SUBSTANCES.
WARNING: UV RISK / HEALTH RISK. THE LAMPS USED WITH THE LS-1812E EMIT AN AMOUNT OF UV RADIATION WHICH CAN BE
DANGEROUS TO HUMAN HEALTH IF NOT PROPERLY SHIELDED AGAINST.
THE FIXTURE MUST NEVER BE USED IN SITUATIONS WHEN DIRECT LIGHT EMISSIONS FROM THE LAMP CAN OCCUR. (Ex: No front
glass, no intentional mirror, damaged front housing).
Lamp Installation & Replacement
• Ensure the fixture is disconnected from the main power supply.
WARNING! LAMP WILL STILL BE HOT TO TOUCH EVEN AFTER THE ALLOTED LAMP REST PERIOD.
THERMAL GLOVES ARE RECOMMENDED FOR WORKING WITH THE FIXTURE AND THE BULB.
• Check to see that the new lamp is the correct wattage.
• Release the lamp clamp level inside the front of the fixture.
• To replace the lamp pull up and out to remove the old lamp.
• Re-tighten the lamp clamping device.
Re-clamp procedures: DO NOT TOUCH THE BULB WITH YOUR BARE-HANDS. This can cause oil to accumulate
on the glass and reduce the performance of the lamp life. The plastic/foam cover which protects the lamp should
NOT be removed until after the lamp is fitted into the fixture. If bulb becomes dirty due to hand contact or foam
contaminant, it can be cleaned with a cloth moistened with alcohol.
• Close the lens door and secure latch.
Ikan is the exclusive distributor of Lightstar products in the United States.
www.ikancorp.com | 1.713.272.8822 | [email protected] because we’re filmmakers too
Ballast Installation Instructions
Connecting a fixture to the ballast and energizing the ballast with power.
Make sure the ballast and the lamp head fixture is compatible.
Check that the ballast is appropriate for the AC Power that will energize the ballast and fixture. (Voltage & Frequency)
The ballast needs to be properly grounded and the main power switch is in the OFF position.
The lamp with proper wattage is fitted into the head fixture.
Make sure the AC Power is not higher than the max power of the ballast.
The safety glass shield is in good working order with no cracks or anomalies. The safety glass is in the proper position and there is a safety wire guard.
Periodic Fixture Inspection
• The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 working hours or at least once a year. This
frequency may need to be increased if the fixture has endured rough treatment. All internal components should only be replaced with Lightstar
spare parts.
• The lamps should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or damaged, otherwise
explosion might occur. Defer to instructions provided by the lamp manufacturer.
• Always check the safety shield before every use.
• All high-voltage components (Ex: Voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 working hours or at least once a
year.
• Outer door hinges and latching system must be checked every 250 working hours. It must be replaced whenever it becomes either cracked or
broken. It is essential for the performance of the fixture.
Specifications
Fixture Specifications
Head Type HMI Fresnel 18000/12000W
Lens Type Fresnel 24.6" Lens
Lamp Base 12000W/200V/G38
Beam Angle 15° - 56°
Control/Dimming 50%-100%
Focusing Knob Control
Build Material Aluminum
Cooling System Air Cooled
Yoke Cast Aluminum w/ 1 1/8"pin
IP Class IP23
Fixture Size 33 x 37 x 48 in.
Fixture Weight 159 lbs
Electronic Ballast Specifications
Power Supply Electronic Ballast 18kW/12kW
Input Voltage 190-250VAC
Electronic Ballast Size 19.9 x 12 x 21.1 in.
Electronic Ballast
Weight 124.7 lbs
Shipping Specifications
Shipping Dimensions Box 1 37 x 33 x 30 in.
Shipping Dimensions Box 2 24 x 15 x 25 in.
Shipping Weight 295 lbs
Learn More
More dynamic information at official website: www.ikancorp.com
Support
Contact email: [email protected]
CONDITIONS OF WARRANTY SERVICE
• Free service for one year from the day of purchase if the problem is caused by manufacturing errors.
• The components and maintenance service fee will be charged if the warranty period is expired.
Free Service will not be Provided in the Following Situations:(*Even if the product is still within the warranty period.)
• Damage caused by abuse or misuse, dismantling, or changes to the product not made by the company.
• Damage caused by natural disaster, abnormal voltage, and environmental factors, etc.
©2017 ikan Corporation. All rights reserved
www.ikancorp.com | 1.713.272.8822 | [email protected] because we’re filmmakers too

Other Ikan Dj Equipment manuals

Ikan Lightstar LSGP-005 User manual

Ikan

Ikan Lightstar LSGP-005 User manual

Ikan MW8-2PT-KIT User manual

Ikan

Ikan MW8-2PT-KIT User manual

Ikan OYB5 User manual

Ikan

Ikan OYB5 User manual

Ikan LSC-007 User manual

Ikan

Ikan LSC-007 User manual

Ikan LSGP-001 User manual

Ikan

Ikan LSGP-001 User manual

Ikan OYB15 User manual

Ikan

Ikan OYB15 User manual

Ikan LS-200E User manual

Ikan

Ikan LS-200E User manual

Ikan WS-F350A User manual

Ikan

Ikan WS-F350A User manual

Ikan Lightstar LSGP-003 User manual

Ikan

Ikan Lightstar LSGP-003 User manual

Ikan MB4-4PT-KIT User manual

Ikan

Ikan MB4-4PT-KIT User manual

Ikan LS-575SPX User manual

Ikan

Ikan LS-575SPX User manual

Ikan LSP-200 User manual

Ikan

Ikan LSP-200 User manual

Ikan Lighstar LSP-003 User manual

Ikan

Ikan Lighstar LSP-003 User manual

Ikan LSP-011 User manual

Ikan

Ikan LSP-011 User manual

Popular Dj Equipment manuals by other brands

Robe ROBIN SilverScan Wireless DMX User Mnaual

Robe

Robe ROBIN SilverScan Wireless DMX User Mnaual

Robe Spot 575 XT user manual

Robe

Robe Spot 575 XT user manual

Blizzard Lighting Flurry Z manual

Blizzard Lighting

Blizzard Lighting Flurry Z manual

EuroLite LED PAR-56 TCL Short Spots user manual

EuroLite

EuroLite LED PAR-56 TCL Short Spots user manual

Karma Wash Series instruction manual

Karma

Karma Wash Series instruction manual

ETC Source Four jr Assembly guide

ETC

ETC Source Four jr Assembly guide

Schnick-Schnack-Systems DMX Player user manual

Schnick-Schnack-Systems

Schnick-Schnack-Systems DMX Player user manual

ProLights CROMOBEAM260 user manual

ProLights

ProLights CROMOBEAM260 user manual

Reloop RMX95 instruction manual

Reloop

Reloop RMX95 instruction manual

American DJ Confusion User instructions

American DJ

American DJ Confusion User instructions

Ibiza PLUTON30-WASH user manual

Ibiza

Ibiza PLUTON30-WASH user manual

DAPAudio Power Jig 6 user manual

DAPAudio

DAPAudio Power Jig 6 user manual

Behringer DJ CONTROLLER CMD STUDIO 4A quick start guide

Behringer

Behringer DJ CONTROLLER CMD STUDIO 4A quick start guide

Robe Robin LedBeam 150 user manual

Robe

Robe Robin LedBeam 150 user manual

Beamz BPP100 instruction manual

Beamz

Beamz BPP100 instruction manual

ExPelec NICOLS BSW 200 LED user manuel

ExPelec

ExPelec NICOLS BSW 200 LED user manuel

Light Emotion DERBY4 User instruction manual

Light Emotion

Light Emotion DERBY4 User instruction manual

EuroLite 500 IR user manual

EuroLite

EuroLite 500 IR user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.