CRYOSAUNA TROUBLESHOOTING GUIDE
The temperature reading is “0” even
though the Cryosauna is turned on.
An interruption in
power causes the
Control Panel to reset
the temperature
display feature.
Press “C” and the temperature will
display.
Press “C” again and you will see the
temperature display switch to
Fahrenheit. Press “F” and you will see
the temperature display switch to
Celsius.
PRV is venting gas continuously and the
Control Panel pressure shows less than 30
psi (for Software Version 8.2.1 or 8.3.7).
or
PRV is venting gas continuously (for
Software Version 7.3.1)
The tank pressure is
incorrect.
DO NOT run any Cryosauna
Sessions.
For Software Versions 7.3.1, 8.2.1 and
8.3.7:
For a Dewar tank, don safety glasses,
thermal insulating gloves, long sleeves,
long pants and closed toed shoes, then
close the liquid valve on the Dewar.
For a bulk tank, don safety glasses,
thermal insulating gloves, long sleeves,
long pants and closed toed shoes, then
press the E-Stop and close the supply
valve on the nitrogen supply line.
Contact Impact Cryotherapy support.
Hissing noise from the back box.
(Software Versions 7 and 8)
A loose component
such as the RTD or
the PRV.
If gas is venting, it
could be an over
pressure situation.
If the RTD capture nut is loose or the
RTD has come out, insert the RTD into
original location and tighten capture
nut with adjustable wrench.
If the PRV is venting, this is a normal
occasional occurrence when the
pressure coming from the tank to the
Cryosauna is too high.
The excess gas will vent out the PRV
located in the back box.
The software will shut down the
Cryosauna to prevent an over pressure
situation inside the Cryosauna. If the
Cryosauna shuts down due to an over
pressure situation, follow these steps:
1. Check the pressure on the tank.