Inel ST-01RL User manual

1
ST-01RL
CONTROLLER WITH BUILT-IN RADIO RECEIVER
for controlling 230 VAC roller blind and shutter drives.
Installation and operating instructions
Basic guidelines
The ST-01RL controller can be safely installed and used provided all of the following instructions of installation and use as well as obligatory
health and safety regulations are adhered to.
The installation and repairing of electrical equipment should be carried out only by persons with appropriate legal qualifications.
Reconstructing or making changes to the ST-01RL controller is forbidden. During the guarantee period repairs only the manufacturer may carry
out repairs. Even after the guarantee period has expired only original parts and accessories may be used.
The guarantee is only valid when the ST-01RL controller has been used in accordance with the manufacturer’s instructions. The boundary values
given in the technical specifications must NOT be exceeded under any circumstances.
Supplementary safety regulations
When installing, using or carrying out maintenance work all binding health and safety regulations should be followed. Particular attention should
be paid to the following:
1. European Standards
2. Fire regulations
3. Accident avoidance regulations
GENERAL COMMENTS REGARDING HAZARDS AND SAFETY PRECAUTIONS
.
The following comments serve as general guidelines to the application of INEL drivers with other devices. These guidelines must
always be adhered to when installing and operating these devices
Warning –this signal warns of possible damage to the control system or other equipment if appropriate safety measures are not
taken.
Before installing the control system and setting the end switches check all bolt connections are properly fastened.
Danger –this signal indicates danger to the user’s life and health if appropriate safety measures are not taken.
Follow all health and safety regulations relevant to the equipment (e.g. gates, roller blinds) used.
When changing fuses the equipment must be first disconnected from the mains, the fuses changed and only then may the equipment be
reconnected to the mains.
The ST-01RL controller should be installed in accordance with appropriate safety regulations and with appropriate safety devices.
INEL equipment connected to the mains beyond a building’s safety fuse system needs to be installed with its own safe disconnecting
devices (e.g. safety fuses and safety switches) in such a way so as to ensure that all the units may be easily and safely cut off from the
mains.
Electric wiring and cables should be regularly checked to ensure the insulation is intact and there are no breaks in the wire.
If any damage to the wiring is found, the unit should be immediately disconnected from the mains and the damaged wiring replaced.
Before connecting any equipment, one should first make sure that it is adapted to be used with the local voltage in the mains.
PERSONAL SAFETY WARNING
Do not allow children to play with any of the control devices.
Keep all remote control devices out of the reach of children.
Observe the opening or shutting of the blinds, shutters, awnings or gates and ensure all persons stand clear until the operation is
completed.
Control system operators need to undergo preliminary instruction and training and also be made aware of all the potential dangers that
can be encountered. A person should only be authorised to use the control system only once the employer, administrator or owner is
satisfied that that person has been properly instructed.
It is not permitted to dispose of waste equipment together with other waste. Dispose only in specially designated areas. The household
plays a key role in the recycling of waste equipment. By correct sorting of waste, including waste equipment and batteries, household
members ensure that the equipment is not disposed together with household waste, but in specially designated areas, and thus may be
used again after recycling.

2
CONTROLLER DESCRIPTION
ST-01RL
The ST-01RL controller is a device used to remotely control the operation of roller blinds and shutters. The device is intended for mounting
in a roller blind cassette.
Remote control is possible with the use of the following remote controllers: PIL-02/04XB, PIL-01PT, PIL-01/04NS, PIL-01/05/09/19DL,
PIL-19/99DLT, PIL-01/05/09/19PM, PIL-19/99PMT, PIL-19/99MMT.
Pressing UP or DOWN on the remote control starts a full cycle of opening or closing the roller blind (the time of applying voltage to the
motor is factory set at 100 seconds).
ST-01RLZ (shutter controller)
The controller allows for precise setting (changing angle) of blind slats remotely with the use of the following remote controllers:
PIL-01/04NS, PIL-05/09/19DL, PIL-19/99DLT, PIL-05/09/19PM, PIL-19/99PMT, PIL-19/99MMT. Setting slat angle is possible after the
controller stops (after 100 seconds elapse) or by sending the STOP command.
When controlled remotely, the device receives commands from remote controllers operating in normal or shutter mode. Commands sent in
normal mode start the full opening or closing cycle. In shutter mode every command causes the controller to start the slat angle setting motor
for a short time.
Connecting ST-01RL and ST-01RLZ controllers
Linstallation L1 wire brown
Ninstallation N wire blue
PE installation PE wire yellow-green
MOTOR motor connection
PE motor protective wire yellow-green
▲motor up wire brown
Nmotor neutral wire blue.
▼motor down wire black
ST-01RL/ST-01RLZ controller connection
▲controller up white
Ncontroller neutral wire blue
▼controller down black
Lcontroller phase wire brown

3
REGISTERING REMOTE CONTROLS
Controlling the ST-01RL with any channel from any remote control is possible after registering that channel for the given controller.
Our controllers allow for two methods of entering the programming mode:
1.
Each time after connecting to mains, the controller will enter the programming mode for 10 seconds.
2.
The other option is to enter the programming mode with a previously registered remote control.
After the controller is received from the manufacturer or if the previous remote control is lost, a new remote can be registered as follows:
Turn on the remote control and select the channel you wish to register.
Connect the controller to the mains: 230 VAC. Within 10 seconds from connecting the mains:
-
press the ▲ and ▼ buttons at the same time for remotes: PIL-01/04NS, PIL-01/05/09/19DL, PIL-01/05/09/19PM, PIL-19/99PMT,
PIL-19/99DLT, PIL-19/99MMT or
-
press the "1" and "2" buttons at the same time for PIL-02XB or
-
press the "C” and "D" buttons at the same time for PIL-04XB or
-
press the Programming button for PIL-01PT
The drive connected to the controller will make an up and down motion. Within the next 10 seconds register the channel:
-
for remotes PIL-01/04NS, PIL-01/05/09/19DL, PIL-01/05/09/19PM, PIL-19/99PMT, PIL-19/99DLT, PIL-19/99MMT press the ▲
button for the channel you wish to register,
-
for remotes PIL-02XB, PIL-04XB press the button of the channel you wish to register,
-
for remote PIL-01PT press the connected blind switch
The registration will be confirmed by a short up-down movement.
WARNING: The procedure will erase all previously registered channels from the memory of the controller.
This will allow to register a remote control with a controller without another registered remote control (new controller or lost/stolen remote).
WARNING: In order to be able to easily change channel numbers for any controller in the future, each of them should have been assigned an
individual channel number. This way you will be able to program it without disconnecting power from other controllers.
If a remote control has already been registered, subsequent channels of the same or another remote must be registered without disconnecting
from the mains. Switch the ST-01RL controller into programming mode with a previously registered remote control.
To do this, for remotes PIL-01/04NS, PIL-01/05/09/19DL, PIL-01/05/09/19PM, PIL-19/99PMT, PIL-19/99DLT, PIL-19/99MMT
press the ▲ and ▼ buttons at the same time. The roller blind will move up and down. Then it will perform a series of up and down motions,
the number of which will match the number of channels that have been programmed. The drive will remain in programming mode for the next
10 seconds. During that time, in order to register a new channel of the same or another remote, select the desired channel on the remote and
press the ▲ button (for remotes PIL-01/04NS, PIL-01/05/09/19DL, PIL-01/05/09/19PM, PIL-19/99PMT, PIL-19/99DLT, PIL-
19/99MMT).
For remote PIL-02XB press the "1" and "2" buttons at the same time, and for remote PIL-04XB press the "C" and "D" buttons at the same
time. The roller blind will move up and down. Then press an already registered button on that remote. The roller will move up and down again
and then make a series of short up and down motions (in the number equal to the number of programmed channels). The drive will remain in
programming mode for the next 10 seconds. During that time, in order to register a new channel of the same or another remote, press the
desired channel (button) on the remote (for remote PIL-02XB/PIL-04XB).
This way you can register any channel to any controller, but only if you have a previously registered remote control.
WARNING: After power supply interruption, the controller will be ready for operation after ca. 10 seconds.
DELETING STORED CHANNELS: (for PIL-01/04NS, PIL-01/05/09/19DL, PIL-01/05/09/19PM, PIL-19/99PMT, PIL-19/99DLT,
PIL-19/99MMT)
Press ▲ and ▼ at the same time for the selected channel of the registered remote control to delete the stored channels.
The roller shutter connected to the controller will move up and down several times. Press ▲ and ▼ at the same time. The roller shutter will
move up and down once. All channels, except for the channel of the remote used in the procedure, will be deleted.
CHANGING ROLLER BLIND MOVEMENT DIRECTION: (for remotes: PIL-01/04NS, PIL-01/05/09/19DL, PIL-01/05/09/19PM,
PIL-19/99PMT, PIL-19/99DLT, PIL-19/99MMT)
If you need to invert the movement of the roller blind (roller blind movement direction does not match the directions on the remote control), you
must enter programming mode by pressing the ▲ and ▼ button (with a previously registered remote) and then press the STOP button on the
same remote control.
Warning - for safety reasons and due to the possibility of damaging the device with static electricity, controller
programming and registered code deletion should be performed on a workbench with appropriate safety and protective
measures in place against electric shock and static electricity.

4
CONTROL UNITS ARE COMPATIBLE WITH REMOTE CONTROLLS UNITS
- HAND-HELD:
PIL-01/05/09/19PM, PIL-19/99PMT, PIL-01/05/09/19DL, PIL-19/99DLT, PIL-19/99MMT
- WALL-MOUNTED:
PIL-01NS, PIL-04NS
- KEYCHAIN:
PIL-02XB, PIL-04XB
- FLUSH-MOUNTED:
PIL-01PT
P. I. E. INEL Sp. z o. o. www.inel.gda.pl
80-778 Gdańsk 01.2021
Table of contents