inohom IM19XDX User manual

Input Module
(IM19XDX)
V1.0
Smart Life Solutions
USER MANUAL
EN

Content
1: Important Safety Information
2: Description and Properties
3: Technical Properties
3.1: Technical Details
3.2: Technical Drawing
4: Installation
4.1: Before Installation
4.2: Mechanical and Electrical Assembly
4.2.1: Return to Factory Settings
4.2.2: Electrical Assembly
4.2.3: Mechanical Assembly
5: Communication Properties
6: Commissioning
7: Regulations
3
4
4
4
5
5
5
6
6
6
7
8
9
10

3
1: Important Safety Informaton
ELECTRIC SHOCK DANGER!
Do not open the product!
Please read ths manual before usng the devce!
Not followng the recommendatons n ths manual mght lead to danger.
The manufacturer GST ELEKTRONİK LTD ŞTİ cannot be hold responsble
for any loss or damagesarsng from not followng the nstructons n ths user manual.
Devce s no longer under warrant after faults arsng n these cases.
The devce s desgned to control other electronc devces and operates n houses.
Incorrect connecton or usage mght cause fire or electrc shocks.
There mght be voltage on the connecton tps even f the devce s turned off.
The fuse or power source must always be dsabled f the connectons wll be changed.
Do not operate the devce wth wet or most hands to avod electrc shock rsk.
Do not make any changes on ths devce that are not specfied n the user manual.
Do not leave the devce drectly exposed to sunlght or other heat sources. Do
not place the devce near open fire or ntense heat sources such as electrc
Other devces
The manufacturer GST ELEKTRONİK LTD. ŞTİ. cannot be held responsble for
any damages or out-of-warranty f any unsutable connectons other than the
connectons expressed n the connecton manual are made wth other devces.
Ths product s desgned only for ndoors use n a dry envronment.
Do not use the product n wet or damp envronment such as bathtub, snk,
bath and pool.
Devce Cleanng
Heat Sources and Fre
Do not clean the product wth solvent (thnner, gasolne, acd etc.) or
abrasve cleanng products. Avod cleanng wth vapour cleanng tools.
heater.

2: Descrpton and Propertes
3: Techncal Propertes
3.1: Techncal Detals
İnohom 4/8 channel Input Module (IM19XDX) ntegrates conventonal swtches
or cabled sensors to your nohom wreless smart home system. There are
programmable 4/8 dry contactor nput.
The supply voltage s manufactured n dfferent models whch can be used as 12VDC or
240VAC. Brand ndependent permanent swtch can be connected to IM19XDX nput that
can fit n standard plug and swtch box.
4
Desgn
Power Consumpton 0.5W (Max)
Supply Voltage 12VDC or 100-240VAC
ABS
4 or 8 Dry Contactor Input
RF 433 Mhz
nohom OS
2.5mm² screwed electrc termnal
IP 20
0 - 50°C
Max 50°C %65 Ambent Humdty
Max 2000m
49mm x 43mm x 29mm
Swtch In-Case Mountng
EN55032:2015, EN55024:2011, EN62368-1
Inputs
Communcaton
Operatng System
Connectons
Protecton Class
Operatng Temperature
Heght
Relatve Humdty
Dmensons
Installaton
EMC Standards
IM19XDX
A:Supply 240 VAC
B:Supply 12 VDC
4:4 Channel Input
8:8 Channel Input

mm
0 5 10 15 20 25
Scale: 3/2
3.2: Techncal Drawng
49mm 25mm
43mm
5
inohom
29mm
4: Installaton
4.1: Before Installaton
Unsutable connectons aganst the manual mght cause health, lfe or materal
damage rsk.
- Do not power on the devce before all the connectons are completed.
- Check the devce user manual to create a secure connecton.
- Do not make any connectons other than the connectons specfied n the scheme.
- Do not connect wth devces that do not comply wth securty standards.
Mount the devce away from metal surfaces or objects to avod any negatve
mpact on the wreless communcaton performance.

4.2: Mechancal and Electrcal Assembly
4.2.1: Return to Factory Settngs
4.2.2: Electrcal Assembly
The supply voltage mght vary dependng on product order code. 4 channel
model nputs are IN0, IN1, IN2 and In3.
L : Phase
N : Neutral
GND : Negatve
Connecton
IN : Input
Connecton
COM (12V) :
Common Drect
Current Contact
Pont
VIN : Sensor
Supply Connecton
OUT : Sensor
Output Connecton
The devce wll return the
factory settngs when the
Reset button s pressed
and held for 10 seconds.
6
Max 18VDC can be nputted to nputs from sensor returns. Input module
nput settng must be changed for sensor return NO/NC state.
The devce mght be damaged f GND and COM(+12V) ends contact.
Any damages due to these problems are outsde the scope of warranty.
inohom
Reset Button
State LED
inohom
N
L
COM (+12V)
GND
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
inohom
N
L
COM (+12V)
GND
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
N
L
N
L
VIN
GND
OUT

The product s desgned wth European standard flush mounted box dmensons.
Permanent swtch or snap swtch can be connected to the nput ndependent of
4.2.3: Mechancal Assembly
7
brand and model.
inohom
inohom
N
L
COM (+12V)
GND
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
inohom
GND
12V
COM (+12V)
GND
IN0
IN1
IN2
IN3
IM198DA IM194DD

5: Communcaton Propertes
inohom inohom
inohom
SMART TOUCH
SWITCH 1
SMART TOUCH
SWITCH 2
WEB
RF 433 Mhz
inohom
CCM176X
16A
COM1
COM2
COM3
COM4
COM5
COM7
COM6
Q1
Q0
Q6
Q7
I 0
I 1
I 2
I 3
I 4
I 5
I 6
I 7
I 15
I 14
I 13
I 12
I 11
I 10
I 9
I 8
Q15
Q14
Q13
Q12
Q11
Q10
Q9
Q8
12V
+ -
Q5
Q4
Q3
Q2
COM0
10A
inohom
IM19XDX
NOVA PANEL
MOBILE
CCM 176X
SWITCH
Other devces
ntegrated va IP
Camera, Intercom, EIO
8
The devces use nohom communcaton protocol. Input Module can wrelessly
communcate wth other nohom products and can learn and swtch output state
values of other products.
İnohom IP Gateway devces (Nova Panel/Home Manager) enable managng other
devces ntegrated to the automaton va the nternet by enablng the system to
communcate on IP layer.

6: Commssonng
9
The commssonng of the nohom products after assembly s completed by the
authorzed nohom dealers and techncal staff. Detaled management panel
nterface ensured communcaton and other settngs between the devces.
At commssonng stage, the “FIND” button on the automaton control panel nterface s
used to dentfy the related devce.
The LEDs on the devce wll blnk wth 1 second nterval when pressed “FIND” button
and press “STOP” button when the devce s found.
Then, settng parameters are sent to the related devce wth “MATCH” button and the
devce becomes operatonal.
“IO TEST” buttons on the control panel nterface can be used for testng the correct
cable connecton of the devce. The state of the desred output can be changed as
on/off and energy flow towards the termnal s dentfied.

7: Regulatons
Legal Warnng
Declaraton of Conformty
GST Elektronk Elektrk Yazlm Makna Dan. San. Ve Tc. Ltd. St.
Kemaloz Mah. Degrmendere Cad. No:8/A 64100 Usak/Turkey
www.nohom.com
0090 850 811 82 83
nfo@nohom.com
The propertes, functonaltes and other product propertes can be changed wthout pror
notce. nohom reserves the rght to revew or update the products, software or documents
wthout any lablty to notfy any ndvduals or organzatons. İnohom s a trademark of
GST Elektronk Elektrk Yazılım Makna Dan. San. ve Tc. Ltd. Şt. All other brand and
product names heren are the trademarks of ther respectve owners.
The domestc producton logo on all the products show
that themanufacturng and software are 100% completed
n Turkey.
The company has ISO 9001 Qualty Management, 14001
Envronment Management, 45001 Occupatonal Health
and Safety Standards.
The devces tagged wth WEEE symbol shall not be dscarded wth other
domestc waste. The product should be delvered to the related collecton pont
for waste electrc and electronc equpment recycle.
CE mark s a free trademark only for authorzed officals and ths mark
does not contan any property assurance.
The product box s manufactured from a recyclable materal. Do not dscard the
package waste wth domestc or other waste and recycle package wastes.
9001:2015 14001:2015 45001:2018
Smart Life Solutions
10
Table of contents
Popular I/O System manuals by other brands

Channel Vision
Channel Vision AB-303 instruction manual

Acromag
Acromag BusWorks 900MB Series user manual

National Instruments
National Instruments 9211 CALIBRATION PROCEDURE

Pilz
Pilz PSS u2 ES 4DOD 0.5A operating manual

National Instruments
National Instruments NI PXIe-4463 CALIBRATION PROCEDURE

olympia electronics
olympia electronics BSR-8020/WP manual

QTS
QTS AN-X2-MOD-MON user manual

Mitsubishi
Mitsubishi AJ65BT-68TD user manual

Pilz
Pilz PSSu E S 4DO 0.5-D operating manual

Rockwell
Rockwell 1732DS-IB8XOBV4 installation instructions

Measurement Computing
Measurement Computing PCI-DAS1000 user guide

National Instruments
National Instruments USB-6001 user guide