INSTEON SWITCHLINC 2476S User manual

Quick-Start Guide
SWITCHLINC RELAY
SwitchLinc V2 Relay (#2476S)
Your new SwitchLinc Relay allows you to control lights and other non-dimmable
devices in your home at the touch of a button.
SET Button
PPrreeppaarraattiioonn
IInnssttaallllaattiioonnsshhoouullddbbeeppeerrffoorrmmeeddoonnllyybbyyaaqquuaalliiffiieeddeelleeccttrriicciiaann,,oorrbbyyaahhoommeeoowwnneerrwwhhooiissffaammiilliiaarraannddccoommffoorrttaabblleewwiitthheelleeccttrriiccaallcciirr--
ccuuiittrryy..IIfftthheerreeaarreeaannyyqquueessttiioonnss,,ccoonnssuullttaanneelleeccttrriicciiaann..FFoorrsseettuuppqquueessttiioonnssccoonnttaaccttTTeecchhSSuuppppoorrttaattSSmmaarrttLLaabbssffoorrgguuiiddaannccee..
TToooollssyyoouuwwiillllnneeeedd::
•A standard screwdriver.
•A Phillips screwdriver.
•A wire cutter/stripper.
NNeeeeddHHeellpp??FFoorraassssiissttaanncceeccaallllyyoouurrffrriieennddllyy
ssuuppppoorrttppeerrssoonn@@886666--224433--88001188
LED Bar
Installing Your SwitchLinc Relay
Step 1. Be sure you have properly installed at least two SignaLinc RF Signal Enhancers (sold separately).
Step 2. At the circuit breaker or fuse panel, disconnect the power for all of the circuits in the switch junction box.
Step 3. Remove the faceplate from the switch junction box, then unscrew the switch and pull it out from the junction box.
Step 4. Disconnect the wires from the switch you are replacing and ensure you have 1/2” of bare wire on the ends.
Step 5. If you are installing the SwitchLinc into a ttwwoo--wwaayycciirrccuuiitt(where one switch controls the load), follow the diagram below
to identify and connect the LINE, LOAD, NEUTRAL, and GROUND wires. If the colors of the wires do not match the
diagram, be sure you have identified the wires correctly before connecting them.
Step 6. If you are installing into a mmuullttii--wwaayycciirrccuuiitt(where more than one switch controls the load), consult the User’s Guide.
Step 7. Ensure that all wire connectors are firmly attached and that there is no exposed copper except for the GROUND wire.
Step 8. Orient the SwitchLinc with the LED bar at the left, gently place it into the junction box, then screw it into place.
Step 9. Turn the circuit breaker back on or reinstall the fuse.
Step 10. Test that the SwitchLinc is working properly by turning the light on and off.
Step 11. Reinstall the faceplate.
NNOOTTEE
The NEUTRAL wire will not normally
be connected to the switch you are
replacing. If there is no NEUTRAL
wire in the junction box, please con-
sult an electrician or call
SSmmaarrttLLaabbssTTeecchhSSuuppppoorrtt
886666--224433--88001188..
TTMM
•Optional: A #1 Phillips screwdriver to change the paddle color (sold separately).
•A voltage tester to identify wires inside the junction box.
SSmmaarrttLLaabbssLLiimmiitteeddWWaarrrraannttyy
SmartLabs warrants to the original consumer of this product that, for a period of two years from the date of purchase, this product will be free from defects in material and workmanship and will per-
form in substantial conformity to the description of the product in the owner's manual. This warranty shall not apply to defects or errors caused by misuse or neglect.
©©CCooppyyrriigghhtt22000066SSmmaarrttLLaabbss,,1166554422MMiilllliikkaannAAvvee..,,IIrrvviinnee,,CCAA9922660066--55002277
886666--224433--88001188wwwwww..ssmmaarrttllaabbssiinncc..ccoomm
SwitchLinc V2 Relay (#2476S)
Quick-Start Guide
SWITCHLINC RELAY
NNeeeeddHHeellpp??FFoorraassssiissttaanncceeccaallllyyoouurrffrriieennddllyy
ssuuppppoorrttppeerrssoonn@@886666--224433--88001188
In a virtual multi-way circuit, only one SwitchLinc Relay, called the SwitchLinc Primary, actually controls the LOAD in the multi-way cir-
cuit. Any additional SwitchLinc Relays, called SwitchLinc Secondaries, are not connected to the LOAD, but only to the powerline (by
being wired to the LINE and NEUTRAL). All of the SwitchLinc Relays can communicate with one another using INSTEON networking on
the powerline. After wiring in the SwitchLinc Relays, you create the virtual multi-way circuit by setting up all of the SwitchLinc Relays
to control one another.
The diagram below shows how you convert a wired-in three-way circuit into a virtual three-way circuit using two SwitchLinc Relays.
Notice that one of the TRAVELER wires (number 1, the red one) is not used, so you will cap it off at both ends with a wire nut.
The other TRAVELER (number 2, the black one) you will convert to a LINE wire. In the junction box where the SwitchLinc Secondary is,
connect TRAVELER 2 to the existing LINE and also to the SwitchLinc Secondary's LINE wire. In the other junction box at the other end,
you will connect TRAVELER 2 to the SwitchLinc Primary's LINE wire.
The SwitchLinc Primary's LOAD wire gets connected to the actual lights that are being controlled.
The LOAD wire for any SwitchLinc Secondaries that you will be installing will not be connected to anything, so cap those LOAD wires
off with a wire nut.
All SwitchLinc Relays, whether they are Primaries or Secondaries, must be connected to NEUTRAL and to GROUND. Note that the
switches you are replacing will not normally have a connection to NEUTRAL. If there is no NEUTRAL wire in the junction box, please
consult an electrician or call SmartLabs Tech Support, 866-243-8018.
UUssiinnggtthheeSSwwiittcchhLLiinnccRReellaayyiinnVViirrttuuaallMMuullttii--WWaayyCCiirrccuuiittss
rev. 071006
SwitchLinc V2 Relay (#2476S)
Quick-Start Guide
SWITCHLINC RELAY
NNeeeeddHHeellpp??FFoorraassssiissttaanncceeccaallllyyoouurrffrriieennddllyy
ssuuppppoorrttppeerrssoonn@@886666--224433--88001188
Quick-Start Guide
SWITCHLINC
Setting Up Your SwitchLinc Relay to Control an INSTEON Device Remotely
SStteepp33..Test that SwitchLinc Relay is working properly by turning the load on and off.
DDeevviicceeSSeettuuppIInnssttrruuccttiioonnss
SwitchLinc Dimmer ••PPrreessssaannddhhoollddthe SwitchLinc Dimmer’s Paddle Top for 10 seconds until the light it
controls flashes —then release.
The SwitchLinc Relay will exit Linking Mode, and its LED will stop blinking.
Lamp Dimmer ••PPrreessssaannddhhoollddthe Lamp Dimmer’s SET button for 3 seconds until the lamp it con-
trols flashes —then release.
The SwitchLinc Relay will exit Linking Mode, and its LED will stop blinking.
Appliance Module ••PPrreessssaannddhhoollddthe Appliance Module’s SET button for 3 seconds until its Status LED
blinks —then release.
The SwitchLinc Relay will exit Linking Mode, and its LED will stop blinking.
Other INSTEON-
Enabled Devices
See device’s Quick-Start Guide or User’s Guide
SStteepp11..PPrreessssaannddhhoollddthe SwitchLinc Relay’s Paddle Top for 10 seconds until its LED starts blinking -- then release.
Your SwitchLinc Relay is now in Linking Mode. You have 4 minutes to complete Step 2.
SStteepp22..Select the device you would like to control and follow the setup instructions from the table below:
•TTaappthe Paddle Top to turn your load on.
•TTaappthe Paddle Bottom to turn your load off.
Using Your SwitchLinc Relay
SStteepp11..On your INSTEON controller pprreessssaannddhhoollddthe ON button of your choice for 10 seconds until the LED begins
blinking slowly -- then release.
Your INSTEON Controller is now in Linking Mode. You have 4 minutes to complete step 2.
SStteepp22..PPrreessssaannddhhoollddthe SwitchLinc’s Paddle Top for 10 seconds until the LED flashes -- then release.
Your INSTEON Controller’s LED will stop blinking to indicate successful linking.
SStteepp33..On your INSTEON Controller press the ON and OFF buttons several times to make sure everything is working properly.
Setting Up an INSTEON Controller to Control a SwitchLinc Remotely
SwitchLinc V2 Relay (#2476S)
Quick-Start Guide
SWITCHLINC RELAY
NNeeeeddHHeellpp??FFoorraassssiissttaanncceeccaallllyyoouurrffrriieennddllyy
ssuuppppoorrttppeerrssoonn@@886666--224433--88001188
TToouunnlliinnkkaaddeevviicceeffrroommyyoouurrSSwwiittcchhLLiinnccRReellaayy
1. Press and hold the PPaaddddlleeTTooppfor 10 seconds -- then release.
2. Press and hold the PPaaddddlleeTTooppaaggaaiinnfor 10 seconds -- then release.
3. On the INSTEON device you wish to unlink, press and hold the OONNBBuuttttoonnfor 10 seconds or the SSEETTBBuutttto
onnfor 3 seconds.
TTooffaaccttoorryyrreesseettyyoouurrSSwwiittcchhLLiinnccRReellaayy
1. Press and hold the PPaaddddlleeTTooppfor 10 seconds -- then release.
2. Tap the SSEETTBBuuttttoonnaalllltthheewwaayyiinn-- then release.
3. Push the SSEETTBBuuttttoonnaallll
tthheewwaayyiinnand hold for 10 seconds -- then release.
NNootteess
• Pressing the SET Button after going into Linking Mode will change Linking Mode to Scene Setup (Multi-Link) Mode
• Any paddle press will exit Linking Mode early.
For detailed instructions on how to operate all the features of your SwitchLinc Relay,
please refer to the User's Guide at http://www.smarthome.com/2476s.html
Using Your SwitchLinc Relay’s Advanced Features
Optional for X10 Users
To give your SwitchLinc Relay an X10 Primary Address
1. Press and hold the PPaaddddlleeTTooppfor 10 seconds -- then release.
2. SSeennddtthheeddeessiirreeddXX1100PPrriimmaarryyAAddddrreessssTTHHRREEEEttiimmeess..
To remove an X10 Primary Address from Your SwitchLinc Relay
1. Press and hold the PPaaddddlleeTTooppfor 10 seconds -- then release.
2. Press and hold the PPaaddddlleeTTooppaaggaaiinnfor 10 seconds -- then release.
3. SSeennddaannyyXX1100aaddddrreessssTTHHRREEEEttiimmeess..

This manual suits for next models

1

Other INSTEON Relay manuals

INSTEON In-LineLinc 2475S User manual

INSTEON

INSTEON In-LineLinc 2475S User manual

INSTEON In-LineLinc User manual

INSTEON

INSTEON In-LineLinc User manual

Popular Relay manuals by other brands

Eaton PKZM0-XDM32ME Instruction leaflet

Eaton

Eaton PKZM0-XDM32ME Instruction leaflet

Basler BE1-50-219 instruction manual

Basler

Basler BE1-50-219 instruction manual

Sel 411L instruction manual

Sel

Sel 411L instruction manual

TIS VLC-6CH-5A installation manual

TIS

TIS VLC-6CH-5A installation manual

Schweitzer Engineering Laboratories SEL-321-3 instruction manual

Schweitzer Engineering Laboratories

Schweitzer Engineering Laboratories SEL-321-3 instruction manual

Emirel W 21 quick start guide

Emirel

Emirel W 21 quick start guide

ABB C6701 operating instructions

ABB

ABB C6701 operating instructions

jablotron AC-160-DIN quick start guide

jablotron

jablotron AC-160-DIN quick start guide

Immergas 3.031943 quick start guide

Immergas

Immergas 3.031943 quick start guide

Eaton EMT62-DB Instruction leaflet

Eaton

Eaton EMT62-DB Instruction leaflet

Pilz PNOZ po3.1p operating manual

Pilz

Pilz PNOZ po3.1p operating manual

Viessmann 5551 Operation manual

Viessmann

Viessmann 5551 Operation manual

Emco EE301-T manual

Emco

Emco EE301-T manual

Measurement Computing USB-ERB24 user guide

Measurement Computing

Measurement Computing USB-ERB24 user guide

Basler BE1-951 manual

Basler

Basler BE1-951 manual

ABB CM-TCN manual

ABB

ABB CM-TCN manual

Aube Technologies RC840 installation guide

Aube Technologies

Aube Technologies RC840 installation guide

Basler BE1-50/51B-217 instruction manual

Basler

Basler BE1-50/51B-217 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.