14
Indoor Unit Installation
[ Left Left-rearpiping ]
Fitting of the Mounting Plate and Positioning of the wall HoleIn case of left sidepiping, cut away, with a nipper, the lid for left
piping.
In case of left-rearpiping, bend the pipes according to the piping
direction to the mark of hole for left-rearpiping which is marked on
heatinsulation materials.
When the mounting plate is first fixed
1. Carry out, based on the neighboringpillars or lintels, a proper leveling
for the plate to be fixed against the wall, then temporarily fasten the plate
withonesteelnail.
Indoor/outdoorelectric cable
Heat insulation
materialPiping
Lid for right Pipesupporting
piping Drainhose plate
Lid for left piping
Lid for underpiping pipe
Fix with adhesive tape
Indoor/outdoorelectric cableanddrain hose must be bound with
efrigerant piping by protecting tape.
[ Other direction piping ]
Cut away, with a nipper, the lid for piping according to the piping
direction andthen bend the pipe according to theposition of wall
hole. Whenbending, be careful not to crash pipes.
Connect beforehand the indoor/outdoor electric cable, and then
pull out the connected to the heatinsulation of connectingpart
specially.
Fixing the indoor unit body
Hang surely the unit body onto the upper
notches of the mountingplate. Move the body
fromside to side to verify its secure fixing.
In order to fix the body onto the mounting
plate,hold up the body aslant from the
undersideandthen put it down perpendicularly. mountingplate
When the mountingplate is fixed side barandlintel
Unloading of indoor unit body
Fix to side bar and lintel a mounting bar, Which is separately sold, and
then fasten the plate to the fixed mounting bar.
Refer to the previous article, “ When the mounting plate is fi rst fixed “,
for the position of wallhole.
When you unload the indoor unit,please use your hand to arise
the body to leave agraffe,then lift the bottom of the body outward
slightly and lift the unit aslant until it leaves the mounting plate.
Making a Holeon the Wall and Fitting the Piping Hole Cover
Make a hole of 60 mm in diameter, slightly descending to outside the wall
Install piping hole cover and seal it off with putty after installation
Wall hole
agraffe mounting plate
Ø60mm
Connecting the indoor/outdoor Electric Cable
Indoor sideOutdoor side
Thickness of wall
(Section of wall hole) GPipingholepipeRemoving the wiring cover
Installation of the Indoor Unit Remove terminal cover at right bottom corner of
indoor unit, then take off wiring cover by removing
its screws.
Drawing of pipe
[ Rearpiping ]
Draw pipes and the drainhose, then fasten themwith the adhesive tape
1. Insert the drain hose into the dent of heatinsulation materials of
indoor unit.
2. Insert the indoor/outdoor electric cable frombackside of indoor
unit,andpull it out on the front side, then connect them.
3. Coat the flaringseal face with refrigerant oiland connect pipes.
Cover the connectionpart with heat insulation materials closely,
andmake sure fixingwith adhesive tape
2. Make sure once more the proper level of the plate, by hanging a thread
ahtiw weight from the central top of the plate, then fasten securely the
plate with the attachment steel nail.
3. Find the wall hole location A/C using a measuring tape
BB== 60 BB== 60
50mm
A=135mm C=50mm
DR2VI-09WFI DR2VI32-09WFI
DR2VI-12WFI DR2VI32-12WFI
10mm
10mm
A=195mm C=165mm
B= 60mm B= 60mm
DR2VI32-18WFI
41.5mm
41.5mm
06=B=B =B=B 06
A=100mm C=110mm
DR2VI32-24WFI
40mm
40mm
Pay attention to the following points before installation of machine:
1. Take out cushion blocks on the left
and right angle beads as shown in
the following Figure.
trednusteksag2evomeR..2
cross-flow fan.
utcarffoecafrusehtnorrubehtnaelC..3
to avoid the power wire from being scratched after removing the
virtual opening of the outgoing
line slot on the case by
hands in indoor
power-on process.