WHEN USING ELECTRICAL APPLIANCES, BASIC SAFETY PRECAUTIONS
SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, AND INJURY TO PERSONS, INCLUDING THE
FOLLOWING:
1. Check the household voltage to ensure it matches the unit’s rated specification
before operating.
2. Children should be supervised to ensure that they do not play with the
appliance.
3. DO NOT add water from moisture outlet directly, or it will damage the unit.
4. Do not allow children to play with any product packaging, such as plastic bags.
5. To avoid fire hazard, NEVER put the cord under rugs, near heat registers,
radiator, stoves, or heaters.
6. DO NOT place humidifier near heat sources such as stoves, radiators, and
heaters. Do locate your humidifier on an inside wall near an electrical outlet.
The humidifier should be at least 10cm away from the wall for best results.
7. Do not attempt to refill humidifier without unplugging the unit from its electrical
outlet first.
8. DO NOT operate any appliance with a damaged cord or plug, after the
appliance malfunctions, or if it has been dropped or damaged in any manner.
Return appliance to manufacturer for examination, electrical or mechanical
adjustment, or repair.
9. DO NOT allow the moisture outlet to directly face the wall.
10. NEVER tilt, move, or attempt to empty unit while it is operating.
11. Shut off and unplug before removing the water tank and moving the unit.
12. DO NOT attempt to repair or adjust any electrical or mechanical functions on
this unit. Doing so will void your warranty. The inside of the unit contains no
user serviceable parts. All servicing should be performed by qualified
personnel only.
13. Do not plug in the cord with wet hands: electric shock could result.
14. NEVER use detergents, gasoline, glass cleaner, furniture polish, and paint
thinner, or other household solvents to clean any part of the humidifier.
15. Do not pour water in any openings other than the water tank.
16. Excessive humidity in a room can cause water condensation on windows and
some furniture. If this happens, turn the humidifier OFF.
17. Never place housing under water flow or immerse in liquids.
18. DO NOT use essential oils, hot water, and other additives. For beat result, use
filtered or distilled water only.
19. DO NOT operate withour tank or of leaking occurs.
20. Clean and fry unit after use. Always plug and unplug the unit with dry hands to
avoid electric shock.
READ AND SAVE THESE IMPORTANT INSTRUCTIONS
Invisipure Sky Cool Mist Ultrasonic Humidifier
Model No: 2516
Model IP-4030
E-1
CONSUMER SAFETY INFORMATION
This is an electrical appliance and requires attention when in use. If moisture forms
on the walls or windows of the room, turn off the humidifier. The room already has
plenty of humidity and additional moisture may cause damage. Do not block air inlet
or outlet.
CORD AND PLUG INSTALLATION SAFETY INSTRUCTIONS
The length of cord used on this appliance was selected to reduce the hazards of
becoming tangled in or tripping over a longer cord. If a longer cord is necessary an
approved extension cord may be used. The electrical rating of the extension cord
must be equal to or greater than the rating of the humidifier. Care must be taken to
arrange the extension cord so that it will not drape over the countertop or table top
where it can be pulled on by children or accidentally tripped over.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is OFF and disconnected from the electrical outlet.
2. Place one a level surface or floor.
3. Filling the water tank
-Remove the water tank by holding the handle and lifting straight upward.
(See figure 1)
-Twist off the tank cap located on the bottom of the tank by turning counter
clockwise and fill the water tank with cool, fresh water. DO NOT FILL WITH
WARM WATER AS THIS MAY CAUSE LEAKING.
-After filling the tank, replace the tank cap by firmly turning clockwise and then
replace the water tank on the base. The tank will immediately begin to empty into
the base.
4. Plug the power cord into an electrical outlet.
MAIN FEATURES
-Handle for easy carrying.
-Compact portable design with transparent tank for easy water level viewing.
-360 degree moisture output to direct mist in any direction
-Easy to use moisture control knob for precise mist output
-Controllable night light with dim/bright for easy using
-Auto Shutoff when water level is low or out
-Higher mist output with improved Japanese motor
-Quiet operation is great for children and light sleepers
-1 gallon tank for up to 40+ hours of continual mist output on the lowest setting
-Waterless shows with red indicator light next to knob for the low water level
OPERATING INSTRUCTIONS
A) Power and moisture control knob
-Press the knob Aclockwise to turn the humidifier on and increase the
mist emission.
-Press the Knob A anticlockwise to reduce the mist emission and turn
the humidifier off.
B) Indicator light for power or waterless
-Indicator light for power on: Green
-Indicator light for waterless: Red.
If the indicator light becomes Red, please kindly refill the water as per
filling water tank instructions promptly.
C) Night light
The night light C can be controlled only when power on
-1st press: Night light is dim.
-2nd press: Night light is bright.
-3rd press: Night light OFF
D) Mist outlet
-By rotating 360 degree mist outlet, the mist shape is much more compact &
vertical.
-Aim the mist outlet away from walls and furniture.
ATTENTION!
If condensation forms on your windows or walls, please turn the humidifier off.
2
3
A
B
D
C
E-2
E-3
DESCRIPTION OF THE HUMIDIFIER
TECHNICAL DATA
·Product name: Invisipure Cool Mist Ultrasonic Humidifier
·Input voltage: AC 120V-240V, 50-60Hz
·Moisture capacity: 12 oz/h / 350ml/h
·Water tank volume: 1 gallon / 3.8 L
·Rated power: 30W
·Dimension: 6.7”x 6.7”x 11.2”/ 170 x170 x285 mm
·Weight: 2.2 lbs / 1.00kgs
·Coverage Area: 325 sq ft / 30 m2
CLEANING AND MAINTENANCE INSTRUCTIONS
Lack of humidity can dry out your skin and can cause irritated nasal passages,
frequent colds, sore throats, and other problems. Humidifiers provide relative
humidity to protect your health. To get the most of the benefit from the humidifier
and avoid product failure, follow all maintenance instructions carefully. If the
recommended care and maintenance guidelines are not followed, micro-organisms
may be able to grow in the water within the humidifier.
DAILY MAINTENANCE
·Before cleaning, turn the power to OFF and unplug the unit.
·Lift the tank off the humidifier.
·Carry the water tank to a sink; drain and rinse the water tank thoroughly to
remove any sediment and dirt. Wipe clean and dry with a clean soft cloth or
paper towel.
·Refill the water tank with cool water.
WEEKLY MAINTENANCE
·Add one cup of white vinegar to the basin for approximately 15 minutes, then
scrub off any scale in the basin, especially in the transducer, with a soft
brush.
·Remove the scale and white vinegar solution with a clean soft cloth.
·Refill the water tank with cool water.
CAUTION OF MAINTENANCE
·Make sure main body is never submerged into water
·Do not use any solvents or aggressive cleaning agents to clean the humidifier.
·Clean the inner parts with a soft cloth.
·Only use soft-bristle or equipped brush to clean the transducer. This should be
done once a week.
·Change the water in the water tank at least once a week.
STORING THE HUMIDIFIER
·Clean the humidifier as described earlier and dry thoroughly.
·Preferably store the humidifier in its original box.
·Avoid high temperatures.
Moisture
outlet
Water tank
Water Tank cap
(Figure 1)
Water level sensor
Air outlet
O-ring seal
Water channel
Transducer
Knob
Night light
Main body
E-4
E-5
If your humidifier is not working correctly please check the following causes:
TROUBLE PROBABLE CAUSE SOLUTION
Humidifier does not
operate.
Power cable not plugged
in
Plug in power cable.
The power light is on, but
there is no mist
No water in water tank
Fill tank with water
The water mist produces
an unpleasant smell.
Dirty water or the water
is left in the water tank
for too long.
Open the water tank and
leave it for 12 hours at shady
and cool place.
Clean the water tank and
change the water.
The power light is on, but
the humidifier doesn’t
work
Too much water in the
basin.
Turn off the unit and remove
water from basin. Check if
O-ring seal in the water cap is
seated properly. Check for
leaks before use.
The output volume of the
mist is low
The transducer is dirty.
Clean transducer by a soft
brush
Water is too dirty or
water kept too long in the
tank
Clean water tank and change
the water
Abnormal noise
Resonance caused
when water level is too
low.
Fill water into water tank
Unit is on an unstable
surface
Move the unit to a stable flat
surface
Very tight tank cap
Cap over tightened
Add liquid soap to O-ring on
the water cap to ease
opening for future use.
Water leaking
Water tank gasket not
seated properly or water
tank/basin has been
compromised.
Check if O-ring seal on the
water cap is seated properly
in the water cap to prevent
leaking. Check for leaks
before use. If leak continues,
do not use. Unplug and
contact manufacturer.
WARRANTY & SERVICE
We guarantee the unit TO BE free from defects in material or workmanship for
a period of one (1) year from the date of purchase.
Operating this unit with an adapter other than the one supplied or any attempts
made to service or modify the unit, will VOID THE WARRANTY.
For your convenience, please record the complete model number and the date
of purchase below, and attach your receipt as proof of purchase.
Serial No.:____________________________________________
Date of Purchase: ______________________________________
Name and address of Purchaser: __________________________
____________________________________________________
____________________________________________________
Telephone: ___________________________________________
This product has been manufactured to comply with EEC Directives
73/23/EEC and 89/336/EEC
Attach your purchase receipt here
E-6

Other Invisipure Humidifier manuals

Invisipure IP-2524 User manual

Invisipure

Invisipure IP-2524 User manual

Invisipure Luna IP-5025 User manual

Invisipure

Invisipure Luna IP-5025 User manual

Popular Humidifier manuals by other brands

Aprilaire 56 operating instructions

Aprilaire

Aprilaire 56 operating instructions

Guardian H910 user manual

Guardian

Guardian H910 user manual

Honeywell HE220 Installation guide & owner's manual

Honeywell

Honeywell HE220 Installation guide & owner's manual

Honeywell HWM-340 Series instructions

Honeywell

Honeywell HWM-340 Series instructions

Eldom NU4 instruction manual

Eldom

Eldom NU4 instruction manual

Medisana 60050 manual

Medisana

Medisana 60050 manual

Thermolec Acu-Steam PRO Series Installation Instructions and Maintenance Manual

Thermolec

Thermolec Acu-Steam PRO Series Installation Instructions and Maintenance Manual

SOLAC HU1050 Instructions for use

SOLAC

SOLAC HU1050 Instructions for use

Bionaire BCM7203 Instruction leaflet

Bionaire

Bionaire BCM7203 Instruction leaflet

DriSteem GTS-100 Installation and operation manual

DriSteem

DriSteem GTS-100 Installation and operation manual

Crane EE-3184-4138, 865, 5058 manual

Crane

Crane EE-3184-4138, 865, 5058 manual

Condair EL installation manual

Condair

Condair EL installation manual

GeneralAire GF-3200PFT installation manual

GeneralAire

GeneralAire GF-3200PFT installation manual

Wood’s WHU600 operating instructions

Wood’s

Wood’s WHU600 operating instructions

Holmes HM2408V owner's guide

Holmes

Holmes HM2408V owner's guide

Prolix music VERTIGO quick start guide

Prolix music

Prolix music VERTIGO quick start guide

Crane EE-8064 SH8201 instruction manual

Crane

Crane EE-8064 SH8201 instruction manual

Essick 726 Care and use manual

Essick

Essick 726 Care and use manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.