Invixium TFACE User manual

TFACE
INGUIDE
Quick Start Guide

Invixium Customer Portal
Stay up to date with:
▪Latest Updates
▪Best Practices
▪Datasheets
▪Installation Guides
▪Feature Description Documents
▪Videos
▪FAQs
▪Tutorials
▪And more...
Visit https://www.invixium.com/support/

In the Box
IXM INSTALL KIT
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
INVIXium
Metal Mounting
Plate
Earth Ground Wire
Metal Mounting
Plate Screw
(qty 1)
Wall Mounting Screws
(qty 4)
Micro USB Extension
Cable (4 ft/1.2m)
Wired Back Cover
Hex Key
Dolphin Crimps
(qty 12)
USB Cover Screw
(qty 1) Gangue Box
Mounting Screws
(qty 2)
Snubber Diode
Ferrite Core
(Selected variants only)

Getting Started
1Remove the Mounting Plate, Wired Back
Cover and Screws from the IXM INSTALL KIT.
2Install the Mounting Plate at the desired
location (Invixium recommends 120 to 125 cms
from the floor to the bottom of the device).
3Make the necessary connections to the Wired
Back Cover (refer to Get Wired Pages).
4Unscrew and remove the Temporary Back
Cover from the device and connect the
Wired Back Cover using the same screws.
5Hang your device on the Mounting Plate
and secure it on the bottom with the screw
provided.

Get Wired Glossary
ACP
COM
DAC
DSP
EGND
LED
NC
NO
RLY
RX
SGND
SPI
SPO
TX
USB
VIN+
VIN-
Access Control Panel
Common
Door Access Control
DGND Digital Ground
Door Strike Power
Earth Ground
Light Emitting Diode
Normally Closed
Normally Open
Relay
PoE+ Power over Ethernet
Receiver
Signal Ground
Specific Purpose Input
Specific Purpose Output
Transmitter
Universal Serial Bus
WDATA Wiegand Data
Power (12VDC)
Power Ground
Top Connector
Bottom Connector
1 3 5 7 9 11 13 15 17 19
2 4 6 8 10 12 14 16 18 20
1 3 5 7 9 11 13 15 17 19
2 4 6 8 10 12 14 16 18 20

Black/Red SGND
Purple/White RS232_TX
Orange/White RS232_RX
Blue/Red RS485_T
Blue/Black RS485_D-
Get Wired Top Connector
Wire Color
Blue
Red/White
White/Grey
Green/Grey
Black/White
Yellow/Cyan
Orange/Yellow
Label
RS485_D+
USB0_VBUS
USB0_D-
USB0_D+
USB0_GND
SPI_1
SPO_1
Wire Pin(s) Wire Color LabelWire Pin(s)
1
3
5
7
9
11
2
4
6
8
10
12
13-20
RJ 45
Receptacle TCP/IP

White/Black WDATA_IN1
Green/White WDATA_IN0
White WDATA_OUT1
Green WDATA_OUT0
Black/Green DGND
Purple DAC_DSP
White/Red RLY_NC
Grey RLY_COM
Grey/Red RLY_NO
Green/Yellow EGND
Get Wired Bottom Connector
Wire Color
Red
Black
Black/Green
White/Purple
Purple/Yellow
Blue/White
Label
VIN+
VIN-
DGND
DAC_IN1
DAC_IN2
DAC_IN3
Wire Pin(s) Wire Color LabelWire Pin(s)
1
3
5
7
9
11
2
4
6
8
10
Brown
Yellow
Black/Green
Orange
ACP_LED1
ACP_LED2
DGND
DAC_OUT
13
15
17
19
14
16
18
20
12

Earth Ground
For protection against Electrostatic Discharge, Invixium recommends the
use of a ground connection between each IXM device to a high quality
Earth Ground available at the install site.
Connect to Earth Ground in the following way:
1
Connect the green and yellow earthing wire from the wired back cover
(bottom connector PIN 2) to the building earthing.
2
Connect the open end of earth ground wire provided in the Install Kit
Box to the building earthing as well.
3
Screw the lug end of the earth ground wire to the metal mounting plate.
Ensure all Earth Ground connections are made to each device prior to
turning on the power.
Earthing Wire from
Bottom Connector (PIN 2) Building Earthing
Earth Ground
Wire Lug
Earth Ground Connections

Power, Ethernet and Wi-Fi
Ensure that a regulated, filtered and dedicated power source
provides a minimum of 12VDC @ 2A per device, when using
an external power supply.
PoE+ connectivity is also available on all TFACE models.
When using PoE+, an IEEE 802.3at compliant Active Midspan
Injector or switch is required (sold separately). Refer to table
for Invixium recommended PoE+ Injector specs. Full PoE+
deployments should include a centralized PoE+ PSE.
For Ethernet communication, a specific range of allowable IP
addresses can be set for improved security.
For Wi-Fi communication, standard 802.11a/b/g/n/ac
protocol is supported. DHCP is enabled as a factory default.
WEP, WPA and WPA2 encryption options are available.
Input Voltage
Recommended PoE+ Injector Specs
100-240 VAC, 50-60 Hz
Input Current 0.75 A
Output Voltage 40-56 VDC
Output Current 0.625 A
Power 24 Watts
INVIXIUM recommends the use of battery back
up or a UPS with built-in surge protection.
WARNING: Product Warranty is void if improper
power (under or over) is supplied to the device.

R = 120 ohms for Standard RS-485 Cabling
R = 100 ohms for CAT5/6 Cabling
Note: Connect RS485_T Wire with RS485_D+, to introduce 120 ohms termination between
RS485_D- and RS485_D+ lines when needed.
RS-485 Configuration
For RS-485 networks, ensure that
IXM
devices are wired in a daisy chain configuration,
up to a maximum
of 31 devices. At a baud rate of 9600 bps, make certain that the
maximum cable length is not longer
than 1200 m (4000 ft).
IXM WEB
Top Connecter RS-485
SGND (12)
RS485_D+ (2)
RS485_D- (4)
RS485_T (6)
RS-485 to USB
Converter

Micro USB OTG Cable
(sold separately)
Bottom USB PortMicro USB Cable
Serial Communication and USB
For Serial Communication, IXM devices are equipped with RS-232 and USB capabilities.
Refer to Get Wired Top Connector page for RS-232 connections.
The USB port can be used to connect a Flash Drive via Micro USB OTG cable and perform
functions like upgrading firmware, downloading transaction logs and configuration files.
The USB port can also be
used to connect to a
PC running IXM WEB via
Micro USB cable.

Standard 26-Bit Wiegand Format
Custom 35-Bit Wiegand Format
Trailing Parity
Bit (Odd)
Leading Parity
Bit (Even)
Leading Parity
Bit (Odd)
Even Parity
Flex Fields (12 Bits) ID (20 Bits)
Facility Code (8 Bits)
ID (16 Bits)
Trailing Parity
Bit (Odd)
Flex Fields* OtherOdd ParityEven ParityID Bits
*Flex Fields can be Facility Code, Job Code or Company ID Code.
0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 341BIT
P F F F F F F F N N N N N N N N N N N N N N N N PF
P F F F F F F F F F F F F N N N N N N N N N N N N N N N N N N N N PP
Wiegand
IXM devices have the
option to use the
Standard 26-bit
Wiegand format or a
Custom Wiegand
format (up to 512 bits)
to suit any Access
Control System.
All IXM devices are set
to Standard 26-bit
format as a factory
default.
N P P F O

ACP_LED2 (15)
ACP Connections
WDATA_OUT0
WDATA_OUT1
DGND
(14)
(16)
(17)
Bottom Connector
ACP_LED1 (13)
2
WDATA_OUT0
WDATA_OUT1
DGND
ACP_LED1
ACP_LED2
TFACE
ACP_LED signals can be used if available on the Access Control Panel. IXM
devices support up to 2 wires for LED status.

RLY_NO
(4)
Max Relay rating = 24VDC @ 2A
NOTE: A separate power supply is required for the door strike
DAC Connections (Electric Door Strike)
Snubber Diode
Request
to exit
DAC_IN2
DAC_OUT
DAC_OUT
DAC_IN1
RLY_NO
Door Strike Power Supply
RLY_COM
Electric
Door Strike
Door
Contact
Bottom Connector
DAC_IN1
DAC_IN2
DAC_OUT
RLY_COM
(6)
(7)
(9)
(19)
TFACE

RLY_NC
(8)
Max Relay rating = 24VDC @ 2A
NOTE: A separate power supply is required for the door strike
TFACE
DAC Connections (Magnetic Lock)
Snubber Diode
Request
to exit
DAC_IN2
DAC_OUT
DAC_OUT
DAC_IN1
RLY_NC
Door Strike Power Supply
RLY_COM
Magnetic
Door Lock
Door
Contact
Bottom Connector
DAC_IN1
DAC_IN2
DAC_OUT
RLY_COM
(6)
(7)
(9)
(19)

(10)
DAC_DSP
RLY_COM
(6)
Max Relay rating = 24VDC @ 2A
Device can supply 12VDC @ 500mA
DAC Connections (Device Powers Door Strike)
Bottom Connector
RLY_NO
DAC_IN1
DAC_DSP
DGND
RLY_COM
DAC_OUT
DAC_OUT
DAC_IN2
Snubber Diode Electric
Door Strike
Door Contact
Request
to exit
TFACE
(5)
DGND
+-
Note: If the device is powering a magnetic
lock, please use RLY_NC wire as shown
on the previous page.
RLY_NO
(4)
DAC_IN1
DAC_IN2
DAC_OUT
(7)
(9)
(19)

Face Enrollment Best Practices
Correct
Incorrect
Invixium recommends standing at a distance of 1.5 to 3 feet from the device when enrolling a face.
Make sure your entire face is in the centre of the screen.
The user should look straight at the camera when enrolling their face. Avoid looking in other directions
or turning your head during enrollment.
120-125 cms /
47-49 inches
< 1.5 feet 1.5-3 feet
120-125 cms /
47-49 inches
120-125 cms /
47-49 inches
> 3 feet

Fingerprint Enrollment Best Practices
Incorrect
Pressure
Position
Rotation
Condition
Dry Wet
Too Low Too High
Good
Good
Correct
Preferred Fingers

1. Proper finger placement is crucial for good enrollment score and faster authentication.
2. Place your finger straight on the sensor as shown below, while covering the sensor with the top
third of your finger as shown on the previous page.
Finger Placement Best Practices
Correct
Incorrect

1. For IXM TFACE, the card reader is placed below the fingerprint sensor.
2. See below for the correct card placement while using the IXM TFACE.
Card Placement
Table of contents