
5
iOptron Corp. | 6E Gill Street | Woburn, MA 01801 USA | (781) 569-0200 | Toll Free (866) 399-4587 | www.iOptron.com
(3) UsetheAzimuthandLatitudeAdj.Knobsto
adjustthemountinbothdirectionsandputthe
PolarisinthelocationonthePolarScopeDial
(sameasindicatedontheHCLCD),asshownin
therightsideoftheabovefigures.
BrightStarPolarAlignment
Whenthepolestarisnotinsight,refertoonline
InstructionManualforBrightStarPolarAlignment.
12. ManualOperation:Themountcannowbeusedto
observeastronomicalobjectswiththeHC.Usearrow
keys(►,◄,▼,and▲)topointthetelescopetothe
desiredobject.Usethenumberkeystochangethe
slewingspeed.PressSTOP/0buttontostarttracking.
13. SetUpController:PresstheMENUbutton;then
“Settings”=>“SetTime&Site”.
EnterthecurrentdateorwaitingfortheGPS
connectedtothesatellites.Enterthetimezone
offsettotheUTC;forexamples:
Bostonis“UTC‐300minutes”
LosAngelesis“UTC‐480minutes”
Romeis“UTC+060minutes”
Sydneyis“UTC+600minutes”
ToggletheDaylightSavingTime(DST)betweenN(No)
andY(Yes)usingarrowkey.Movethecursortothe
endofscreentoselecttheNorthernorSouthern
Hemisphere.
[TIPS:AlltimezonesinN.Americaare“UTC‐XXX
minutes”.Latitudeandlongitudecoordinatescanbe
obtainedfromGPS‐equippeddevices(navigator,
phone),orfrominternet,ifyouareenteringthem
manually.“W/E”=western/easternhemisphere;
“N/S”=northern/southernhemisphere;and“d”=
degree;“m”=minute;and“s”=second.Usearrow
andnumberkeystoenterlocationinformation.]
14. ZeroPositionandOneStarAlignment:Thedefault
mountpoweronpositionisnotnecessarythezero
positionforCEM25/CEM25EC,especiallyitisthefirst
timetousethemountorjustperformedfirmware
upgrade.SettheZeroPositionbypressMENU=>
“ZeroPosition”=>“SetZeroPosition”.Youshould
makesurethemountisatZEROpositionbypress
MENU=>“ZeroPosition”=>“GotoZeroPosition”
whenthemountispoweredon.PerformaOneStar
AligntocorrecttheZeroPositiondiscrepancy.To
furtherimprovetheGOTOaccuracy,refertothefull
User’sManualformoredetails.
15. GotoanObject:ThemountisnowreadyforGOTO
andtrackingtargets.PressMENU,selectandENTER
“SelectandSlew”.Selectacategory(forexample,
“SolarSystem”),thenselectanobjectofinterest(for
example,“Moon”).PressENTERandthetelescope
willslewtotheobjectandautomaticallystart
tracking.
16. SynctoTarget:Iftheobjectisnotinthecenterof
theeyepiece,usethisfunctiontocenterand
synchronizetheobjecttoimprovelocalGOTO
accuracy.PressMENUandselectandENTER“Sync
toTarget”.Usearrowkeyscentertheobjectin
eyepiece.PressENTERagaintocompletethis
function.
[TIP:“SynctoTarget”canonlyfunctionaftera
“SelectandSlew”operation.Thisismostuseful
whenlookingforfaintobjectsnearabrightstar.]
[TIP:Afterslewingtoanobject,alistofnearbybright
object(s)canbedisplayedbypressing“?”button.]
Use support@ioptron.com for technical supports.
2013-04-01 12:01:36
UTC -300 Minute(s)
W071d08m50s DST: Y
N42d30m32s Northern