(2) Use the Hand Controller (MENU => “Align” =>
“Pole Star Position”) to display the Polaris
Position on the LCD screen, as indicated in the
leftsideofthefigurebelow.Forexample,June
22,2014,20:19:42inBoston,US(altN42°30’32”
and long W71°08’50”), 300 min behind UT, the
PolarisPositionis0h45.8mand40.4m.
(3) Use the Azimuth and Latitude Adj. Knobs to
adjust the mount in both directions and put the
PolarisinthelocationonthePolarScopeDial
(sameasindicatedontheHCLCD),asshownin
therightsideoftheabovefigures.
BrightStarPolarAlignment
Whenthepolestarisnotinsight,refertoonline
InstructionManualforBrightStarPolarAlignment.
12. Manual Operation: The mount can now be used to
observeastronomicalobjectswiththeHC.Usearrow
keys(►,◄,▼,and▲)topointthetelescopetothe
desired object. Use the number keys to change the
slewingspeed.PressSTOP/0buttontostarttracking.
13. Set Up Controller: Press the MENU button; then
“Settings”=>“SetTime&Site”.
EnterthecurrentdateorwaitingfortheGPS
connected to the satellites. Enter the time zone
offsettotheUTC;forexamples:
Bostonis“UTC‐300minutes”
LosAngelesis“UTC‐480minutes”
Romeis“UTC+060minutes”
Sydneyis“UTC+600minutes”
ToggletheDaylightSavingTime(DST)betweenN(No)
andY(Yes)usingarrowkey.Movethecursortothe
endofscreentoselecttheNorthernorSouthern
Hemisphere.
[TIPS:AlltimezonesinN.Americaare“UTC‐XXX
minutes”.Latitudeandlongitudecoordinatescanbe
obtained from GPS‐equipped devices (navigator,
phone), or from internet, if you are entering them
manually. “W/E” = western/eastern hemisphere;
“N/S” = northern/southern hemisphere; and “d” =
degree;“m”=minute;and“s”=second.Usearrow
andnumberkeystoenterlocationinformation.]
14. Zero Position and One Star Alignment:Thedefault
mountpower onposition isNOTnecessarythezero
positionforCEM25/CEM25EC,especiallyitisthefirst
time to use the mount or just performed firmware
upgrade. Set the Zero Position by press MENU=>
“ZeroPosition”=>“SetZero Position”.Youshould
make sure the mount is at ZERO position by press
MENU => “Zero Position”=>“Goto Zero Position”
whenthemountispoweredon.PerformaOneStar
Align to correct the Zero Position discrepancy. To
furtherimprovetheGOTOaccuracy,refertothefull
User’sManualformoredetails.
15. GotoanObject:ThemountisnowreadyforGOTO
andtrackingtargets.PressMENU,selectandENTER
“Select and Slew”. Select a category (for example,
“SolarSystem”),thenselectanobjectofinterest(for
example, “Moon”). Press ENTERandthetelescope
will slew to the object and automatically start
tracking.
16. Sync to Target: Iftheobjectisnotinthecenterof
the eyepiece, use this function to center and
synchronize the object to improve local GOTO
accuracy. Press MENUandselectandENTER“Sync
to Target”.Usearrowkeyscentertheobjectin
eyepiece. Press ENTER again to complete this
function.
[TIP:Afterslewingtoanobject,alistofnearbybright
object(s)canbedisplayedbypressing“?”button.]
Use support@ioptron.com for technical supports.
2013-04-01 12:01:36
UTC -300 Minute(s)
W071d08m50s DST: Y
N42d30m32s Northern