4
iOptron Corp. | 6E Gill Street | Woburn, MA 01801 USA | (781) 569-0200 | www.iOptron.com
balanced in both DEC and RA axes to ensure
minimum stresses on the mount driving mechanism.
CAUTION: The telescope may swing freely when the
R.A. or DEC Gear Switch is disengaged. Always hold
on to the mount and/or telescope assembly before
releasing the Gear Switches to prevent it from
swinging, which can cause personal injuries and/or
equipment damages.
Set the mount at Zero Position. Disengage both RA
and DEC gear switches and move the mount to
horizontal position to check balance. Return to Zero
Position for balance adjustment. Balance the DEC axis
by moving the scope with accessories back and forth
in the mount saddle or within the scope mounting
rings. Balance the assembly in R.A. axis by moving
CW along its shaft. Repeat the process until both DEC
and RA axes are balanced.
CAUTION: The balancing process MUST be done with
Gear Switch at the total ddisengaged position!
Otherwise it might damage the worm system.
Return the mount to Zero Position after balancing
and engage gear switches.
7. Connecting Cables: Plug in included 12V/5A DC
power supply to the DC12V 5A socket, which is
located at the end of the RA axis.
Connect the Go2Nova®8407 Hand Controller to the
HBX port on the mount main board.
Plug GPS module into the iPORT with a coiled cable.
8. When powering on, GPS ON sign should be displayed
at the upper right corner of the hand controller. You
may disconnect the GPS module after it picks up
satellites signals and displays GPS OK. (It takes about
1 to 2 minutes in normal conditions).
9. Polar Alignment: CEM40 equipped with an iPolarTM
electronic polar scope. To perform polar alignment,
please refer to CEM40 User’s Manual, or iPolar
Operation Manual from iOptron’s website, or steps
briefly outlined below:
Download and install iPolar Software (first
time use)
Connect a USB cable between the USB2.0
port on the rear end of the mount RA axle
and a computer USB port
Click Connect and start polar alignment by
following on screen instructions
For the mount without polar scope, please refer to
full manual for Bright Star Alignment, or use
software to assist alignment.
10. Manual Operation: The mount can now be used to
observe astronomical objects with the HC. Use arrow
keys (►, ◄, ▼,and ▲) to point the telescope to
desired objects. Use the number keys to change the
slewing speed. Press the STOP/0 button to start or
stop tracking.
11. Set Controller: Press the MENU button; then Settings
=> Set Time and Site.
Before GPS picks up signals (before displaying GPS
OK), check for Daylight Saving Time using arrow key
to toggle between Yand N. Enter the time zone
offset to the UTC; for examples: