iPollo V1 mini Classic Series User guide

V1 mini Classic Series
Server Setup Manual
iPollo

V1 mini series server instruction manual
- 2 -
V1 mini Classic Series have 4 models:
(1)iPollo V1 mini Classic;
(2)iPollo V1 mini Classic WiFi;
(3)iPollo V1 mini Classic Plus;
(4)iPollo V1 mini Classic Plus WiFi。
During use, only the network settings are different, and the versions are
divided into WiFi version and wired connection version.

V1 mini series server instruction manual
- 3 -
I. V1 mini Classic WiFi: Check Before Use
1. Sign For Inspection
(1) When signing for the new server, please check whether the appearance of the package is damaged.
If there is any damage, please take a picture and contact our after-sales service.
(2) After opening the package, please check whether the server case is deformed, whether the fan and
connecting cable are damaged, and whether the cable is damaged. If there is any damage, please
take a picture and contact our after-sales service.
(3) Please check whether there is any abnormal sound on the server. If there is any abnormal sound,
please contact our after-sales service.
2. After-sales contact information
(1) Official Website: www.ipollo.com
(2) Official Wechat Account:iPollo
(3) Facebook:@iPolloGlobal
(4) Twitter:@iPolloGlobal
(5) E-mail:su[email protected]
3. Notes
(1) Recommended ambient temperature range: 10℃-25℃.
(2) The hashrate is subject to the 24-hour hashrate of the Mining Pool.

V1 mini series server instruction manual
- 4 -
(3) Pay attention to dust and foreign matter, so as not to corrode the computing board or affect the heat
dissipation of the server.
(4) It is recommended to use Google browser or Firefox browser to browse the server background.
(5) It is strictly forbidden to plug and unplug the power cable and signal cable under power. The AC
side of the power supply of the server must be reliably grounded.
II. V1 mini Classic WiFi: Product Introduction
1. Main Components
(1) “1”: WiFi signal receiver
(2) “2”: power cable
(3) “3”: V1 mini Classic WiFi
(4) “4”: power adapter(the pictures are for reference only, please refer to actual products.)
2. Interface Introduction

V1 mini series server instruction manual
- 5 -
Fault
The fault warning light. In most cases, when this light flash, it indicates that a
fault has occurred
Normal
Running indicator light. In most cases, when this light is on, it indicates that the
machine is working normally
Reset
Server factory reset button
IP Report
Use the show IP software to feed back the IP of this server to the computer
TF card
SD card slot
Power
Power interface
ANT
WIFI antenna

V1 mini series server instruction manual
- 6 -
ETH
Network interface
3. Notes
(1) In the process of running the server, please place it as shown in the picture below, that is, keep it flat
to avoid any damage to the server.
(2) The socket shall be installed near the server and shall be easily accessible.
(3) The two 6PIN power ports must be connected at the same time before the supplying power.
(4) This product requires a power input of 100~240VAC to make the product work normally. When the
server is powered off, the power switch must be turned off first.
(5) For your safety, it is forbidden to remove any screws on the server.
(6) Do not press the metal buttons on the casing.
III.V1 mini Classic WiFi: Use and Configuration
1. Server Connection
(1) Power Connection
The V1 mini Classic WiFi dedicated power supply has two 6PIN DC outputs, and the input of the power
supply is 100~240VAC. The server can work normally after confirming that the connection is good.

V1 mini series server instruction manual
- 7 -
(2) Internet Connection
(2-1) Wired Connection
The interface marked “ETH” on the server interface panel is the network cable interface. Pay
attention to the direction when inserting the cable. Please insert the crystal head in place. After
inserting it in place, you will usually hear a light “click” sound.
(2-2) WiFi Connection
The red box in the picture is the WiFi antenna ,WiFi signal can be connected, For details, please visit
“ipollo.com/support”.

V1 mini series server instruction manual
- 8 -
2. Log in to the Server
2.1 Find the server IP
After the server is powered on and connected to the Internet, it starts to start. After the server’s normal
starts to light up, you can find the IP of the server. You can use the “show IP” software to find the server
IP as follows:
(1) Download software: http://www.nano.cn/download/ShowIP.exe
(2) Double-click “show IP” to open the software.
(3) Short press the “IP Report” button on the server for 1 second and release it.
(4) The server IP information is fed back on the PC, as shown below:
Note: The server and PC must be in the same network segment, otherwise the IP information
returned by the server cannot be received.

V1 mini series server instruction manual
- 9 -
2.2 Enter the Server Backstage Management System
(1) After finding the IP of the server, enter the obtained IP address in the browser (Google is
recommended), press Enter to enter the server login interface, and enter the default administrator
account and password: root
(2) press “Login” to enter the Server Backstage Management System as follows:
3. Server Settings
Click the "Miner Configuration" interface of "Configuration" to set the "Mining Pool" and
"Network"

V1 mini series server instruction manual
- 10 -
3.1Fill in the Mining Pool Information
Note: This manual takes the “antpool” as an example.
ETC mining address: stratum+tcp:// 47.108.153.82:8008
(1)Select "Pool Configuration" and fill in the Mining Pool Information
(1-1) The "Url" in "Mining Pool 1" is filled with the ETC AntPool mining link address: stratum+tcp://
47.108.153.82:8008
(1-2) "Worker" in "Pool 1" fill in "ipollomini.001"; "ipollomini" is a custom "sub-account" in the
corresponding Mining Pool account; the number suffixed with ".001" is the number used to distinguish
the server;).
Note: For customization such as numbers or letter combinations, use English periods to separate them,
only modify the corresponding characters, and do not increase or decrease spaces and punctuation)

V1 mini series server instruction manual
- 11 -
Note: In order to prevent “Pool 1” from being disconnected, causing the server to not work, it is
recommended to set “Pool 2” and “Pool 3” at the same time, so as to ensure that the system will
automatically switch to “Pool 2” or "Pool 3” for normal operation when “Pool 1” goes offline.
3.2 Network Settings
Regarding network connection, V1 mini Classic Series products are divided into two models: "wired
connection" and "WiFi connection". You can set the server according to the corresponding model
obtained by following the instructions below:
3.2.1 Wired connection
(1) Select “Network Configuration” and fill in the network information:
(2) In the protocol column, select one of “DHCP (dynamic)” or “Static” (optional).
(2-1) Select “DHCP (Dynamic)” State:The server automatically obtains an IP address

V1 mini series server instruction manual
- 12 -
After setting, click “SAVE&APPLY”, the system will save and automatically restart to take effect,
and the server will start to run normally.
End here, the configuration of the server has been completed, congratulations on your
becoming a miner.
(2-2) Select “Static” State
(a) Enter the IP address, netmask, gateway, and DNS-Server in turn in the four boxes below, then
click “SAVE&APPLY”.
(b) After the page buffering is completed, the configuration of the server has been completed,
congratulations on your becoming a miner.
Image (Static)

V1 mini series server instruction manual
- 13 -
Note: The protocol information filled in "Network Configuration" in the figure (staic) is for
reference only, please refer to the on-site network protocol information for details.
3.2.2 WiFi connection
(1) After the V1 mini Classic WiFi server is powered on, it will send out the WiFi signal
"iPollo_XXXXX"; turn on the laptop and connect to the wireless signal "ipollo_XXXXX"
(2) Browse the server's default IP address "192.168.2.1" on the website to enter the server login
interface:
(3) Enter Password "root" to enter the server background control interface, click "Wireless" to enter
the wireless setting interface

V1 mini series server instruction manual
- 14 -
(4) Modify the SSID and corresponding password (please make sure there can be no errors, otherwise
the server cannot connect to the correct network)
(5) Click "Save and Apply" after editing

V1 mini series server instruction manual
- 15 -
(6) After the application, the server needs to be powered off and restarted;
(7) The laptop is connected to the wireless signal "Nano (the network of the environment where the
computer belongs)"
(8)Open the showIP tool, and press the "IP report" button of the server to obtain the new IP address of
the server, which is the IP of the WiFi setting.

V1 mini series server instruction manual
- 16 -
(9) Use Google Chrome, log in to the IP displayed by the above tool showIP, you can enter the server
management background, and fill in the mining pool information to complete the server settings.
3.3 Login Password Modification
If you need to change the server login password, the operation method is as follows:
(1) The server is powered on and connected to the network;
(2) Through the browser (Google), enter the server IP account password and login information in turn
to enter the server web page background;
(3) Click "System" and select " Password Change ";
(4) Enter the modified new password in “New Password”, and enter the modified new password again
in “Confirmation”, and then click “SAVE” below to take effect:

V1 mini series server instruction manual
- 17 -
Note: The “Antpool” mining pool is used as an example above. If you use other mining pools, please
modify it to the address of the mining pool you want to use and refer to the corresponding mining pool
operation instructions.
IV. WARNING
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
NOTE:This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
--Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm
etween the radiator & your body.

V1 mini series server instruction manual
- 18 -
6. If you need to disassemble the case to check the problem, please contact customer service
support first. If you open the case without permission, the warranty will be voided.
V. Important Notice
1. After the machine is running normally, please use the "24-hour hashrate of the Mining
Pool" as the criterion for stability.
2. It is recommended to use the original standard power supply to avoid damage to the
machine or safety accidents.
3. Try to use the original standard power supply to suppress the voltage shock at the moment
of power-on.
4. Please be careful not to spill water or other liquids on the machine, especially the non-case
parts.
5. Please pay attention to ventilation and heat dissipation, do not block the vents, and do not
place on flammable materials and fabrics.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux
CNR d’Innovation, Scienceset Développement économique Canada applicables aux appareils
radio exempts de licence. L’exploitation est autoriséeaux deux conditions suivantes :
(1) L’appareil ne doit pas produire de brouillage;
(2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettrele fonctionnement.
RF Exposure Statement:
This equipment complies with Canada radiation exposure limits set forth for uncontrolled
environments. This equipment should be installed and operated with a minimum distance of
20cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
Cet équipement est conforme aux limites d’exposition aux radiations définies par le Canada
pour des environnements non contr?lés. Cet équipement doit être installé et utilisé à une
distance minimum de 20 cm entre l’antenne et votre corps.
Cet émetteur ne doit pas être installé au même endroit ni utilisé avec une autre antenne ou
un autre émetteur.
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation,
Science and Economic
Development Canada’s license-exempt RSS(s). Operation is subject to the following two
conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
This manual suits for next models
4
Table of contents
Popular Server manuals by other brands

Supermicro
Supermicro SUPERSERVER 5039MC-H12TRF user manual

Compaq
Compaq 108164-003 - ProLiant - 800 Integration notes

Lantronix
Lantronix Console Server 3200 user manual

HP
HP Integrity BL860c Quickspecs

Johnson Controls
Johnson Controls DVN 5000 Series manual

Digital Watchdog
Digital Watchdog DW-BJP1U-LX quick start guide