Italtherm CITY PLUS manual

CITY PLUS
Instruction
Handbook for:
use
adjustment
maintenance
installation
30 F
24 F

Green Heating Technology
2
Table of Content
Safety warnings
Safety warnings symbols legend ............ 4
References to Laws and Norms ............. 4
Personnel in charge of installaon .............4
Installaon, use and maintenance .............4
User warnings .......................... 5
Important . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
First starng up and Use .....................5
Installaon, rst starng up, maintenance
and servicing ...........................6
Appliance booklet or central plant booklet ......6
Combuson checking .......................6
Boiler operaon and servicing ................6
User guide
The front control panel ................... 7
Commands on the lower side .............. 8
Commands outside the boiler ............. 8
Typical use ............................. 9
Preliminary operaons ......................9
Boiler acvaon ............................9
Temperature adjustment .....................9
Incidental malfunconing ................ 10
The burner doesn’t turn on ..................10
Shortage of domesc hot water producon ....10
Boiler inacvity ........................ 11
Safety shut o ............................11
Stand-by mode with an-frost & an-locking
funcon ...............................11
“Ambient An-Frost” Funcon ...............12
Law and regulaon prescripons for the
installer ............................ 12
Dimensions and connecons ............. 13
Pump capacity diagram .................. 13
Specicaons for inlet air ................ 13
Domesc water supply characteriscs ...... 14
Protecon against freezing ............... 14
Outdoor installaon in a parally protected
place .............................. 14
Posioning and fastening ................ 15
Hydraulic system (DHW and heang) ....... 16
Advices and suggesons to avoid vibraons
and noises in the system .................16
Cleaning and preservaon of the systems ......16
Heang system ............................16
Heang system lling and pressuring ...... 16
Gas connecon ........................ 17
Electrical connecons ................... 18
Flue systems ........................... 18
General indicaons ........................18
Reducer for short systems ...................19
Flue terminals posioning ...................20
Flue system types ..........................21
Adjustment and Maintenance
First starng up ........................ 22
Access to the inside of the boiler .......... 22
Inlet gas check ......................... 23
Max and Min pressure adjustment ........ 23
Max heang power adjustment ........... 24
Burner pressure tables .................. 26
So ignion ........................... 27
Electronic sengs ...................... 27
Accessing the main board ...................27
Main board sengs ........................27
Gas conversion ......................... 28
Combuson check ...................... 29
Hydraulic sengs (pump speed) .......... 29
Draining the heang system .............. 30
Alarms - boiler block .................... 30
Warnings for servicing ................... 33
Technical data .......................... 34
Boiler internal components .............. 36
Electrical diagram ...................... 37
Hydraulic diagram ...................... 38
Remote Control Kit ..................... 39

Green Heating Technology
3
Safety warnings
This instrucons manual is an essenal and complementary part of the product and it is supplied to-
gether with the boiler.
Carefully read the manual, achieving all important informaon for a safe installaon, use and
servicing.
fCarefully keep the manual, together with the documentaon of all the accessories of the boiler and
of the system, for any further consultaon you may need.
f must be carried out by a qualied technician, in accordance with manufacturer in-
strucons and with the relevant requirements of the current issue.
fCarbon monoxide (CO) danger: the CO is a no-smelling and no-colour gas. When a forced draught
boiler with air inlet from the room (appliance type B2) is installed, permanent venlaon of the
installaon room is mandatory and extremely important. Venlaon must be made and sized in
compliance with Laws and Rules in force. Whatever manumission, closing or neutralizaon of the
permanent venlaon could lead to very serious consequences to people in the rooms, as intoxica-
on by CO, permanent damage and death. Besides, the CO and O2mix can be explosive.
fA is a person with a specic technical competence in the eld of the heang
appliances for domesc use and domesc hot water producon, in compliance with Laws and Rules
in force.
fThe are only and exclusively the ones contained in the "USER GUIDE"
secon.
fThe manufacturer has no contractual and extra-contractual responsibility for any damage arising
from wrong installaon, wrong use and non-observance of current laws and instrucons given by
the manufacturer himself.
fImportant: this gas boiler is used to heat the water at a temperature lower than the boiling one, at
atmospheric pressure; it must be connected to an heang system and/or to a domesc hot water
system, in accordance with its features and power.
fPacking items (cartons, nails, plasc bags and so on) , as
they are potenally dangerous.
f, disconnect the boiler from the mains electrical supply by
means of the main electrical switch and stop the gas supply by means of the suitable cock.
fIn case of fault and/or bad operaon of the appliance, disconnect it immediately and do not try to
repair it by yourselves.
fBoiler servicing and repair must be carried out exclusively by qualied technicians, which will use
original spare parts. Strictly observe the above requirement, avoiding any risk of compromising the
appliance safety.
f, remove or cut o any potenal dangerous item.
fWhen transferring the appliance (e.g. leaving it installed aer a removal or a sale of the building),
make always sure that the instrucons manual is close to the boiler for the future use of new owners
and/or installers.
fThis appliance . Any other ulizaon must
be considered dangerous and incorrect.
fIt is strictly forbidden to use the appliance than the specied ones.
fThis appliance must be installed exclusively to wall.

Green Heating Technology
4
Safety warnings symbols legend
Generic safety
warning
Electrical danger
(fulguraon)
Physical danger
(personal damage)
Thermal danger
(burns)
General warning or advice to avoid material damage
or to achieve improvements
References to Laws and Norms
All the menoned in this handbook are indicave as
laws and norms are subject to issues and integraons by the authories in charge. Also comply
to eventual local norms and laws (not menoned in this handbook) in force in the territory
where the installaon takes place.
Personnel in charge of installaon
Place here all necessary advices according to naonal rules about WORK SAFETY of Personnel in charge
of installaon. An example follows:
Law number 192 of 19-August-2005 and further revisions “Title of the law or brief descripon”.
Always proceed with cauon when handling the boiler and carrying out installaon/mainte-
nance work as metal parts may cause injuries such as cuts and abrasions. Wear personal protec-
(especially gloves) while doing the above menoned operaons
Installaon, use and maintenance
Place here all necessary advices according to naonal rules about BOILER INSTALLATION, An example
follows.
Law number 412 of 26-July-1993 n°412 and further revisions “Title of the law or brief descripon”.

Green Heating Technology
5
User warnings
Important
In case of gas smell:
1 - do not press electrical switches, use the telephone or other objects that can provoke
sparks;
2 - open immediately the windows and the doors in order to cleanse the room air;
3 - close the gas supply taps;
4 -
of the gas boiler room, in order to avoid possible
dangerous situaons as the creaon of poisonous or explosive mixtures.
First starng up and Use
The rst starng up and the maintenance of the boiler must be performed by a professionally
qualied sta (for example the installer or the Service Centres authorized by ITALTHERM)
Gas conversion from a gas of a specic family to a gas of another family (from natural gas to LPG or vice
versa) to another gas, can be made also when the gas boiler is already installed, but only by a qualied
technician. The technician will check that:
fthe label technical data of the gas boiler correspond to those of the gas available;
fthe main burner regulaon is compable with the gas boiler output;
fthe chimney works correctly, expelling the combuson products;
fthe air supply and the combuson products evacuaon work correctly, in accordance with the re-
quirements in force;
fthe condions for a correct venlaon are guaranteed, also when the gas boiler is located inside a
closed space (with suitable caracteriscs).
The User must not touch sealed items nor break the seals. Only specialized technicians and the
ocial technical service can break the seals of sealed items.
The boiler is ed with a safety ue ow detecon device that should never be bypassed or put
out of order. If the pressure switch must be replaced, use the original spare part only. In case
of repeated intervenons of the device (and consequent boiler locks), check that the Air Flue
Products Inlet/Outlet System is ecient and made according to the laws in force (see examples
in paragraph "Flue systems" on page 18).
When the boiler is o for a long period see the Paragraph "Boiler inacvity" on page 11 for the
necessary precauons about the electrical supply, the gas supply and the protecon against
freezing.
Do not touch the heated surfaces of the boiler, as the doors, the ue, the chimney pipe, etc.,
also aer the boiler operaon because, for a certain me, these surfaces are overheated. Any
It is then forbidden to let children or inexperi-
enced people be close to the boiler, during its operaon.
fDo not expose the wall hung gas boiler to water or other liquids sprinklings, or to vapours directly
coming from gas cookers/hobs.
fDo not obstruct the air inlet or ue outlet terminals, even momentarily or parally.

Green Heating Technology
6
fDo not put any object on the gas boiler and don't leave any ammable liquid or solid materials, (e.g.
paper, clothes, plasc, polysrene) in its proximity.
fThis appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilies, or lack of experience and knowledge, unless they have been given supervi-
sion or instrucon concerning use of the appliance by a person responsible for their safety. Children
should be supervised to ensure that they do not play with the appliance. (CEI EN 60335-1:2008-07 § 7.12)
fIf the gas boiler is going to be denively unused, call a qualied technician to carry out all required
operaons, checking in parcular disconnecon of gas, water and electrical supplies.
f (type B appliances installed in-
door): the installaon of aspirators, replaces or similar appliances in the room where the type B ap-
pliance is installed (and in adjacent rooms in case of indirect venlaon) is prohibited except in cases
foreseen by rules in force and anyway the installaon must be made in compliance with all specic
safety measures menoned in the rules and laws in force, even in case of modicaons or addions.
Installaon, rst starng up, maintenance and servicing
All operaons for installaon, rst starng up, maintenance, servicing and gas conversion must be car-
, in accordance with the Norms and Laws in force.
Maintenance operaons must be carried out in compliance with the manufacturer prescripons, and in
compliance with the laws and rules presently in force for what is not menoned in this handbook; we
advice to perform them at least once a year to maintain the boiler’s performance.
Appliance booklet or central plant booklet
All appliances must have an appliance booklet (for outputs less or equal 35 kW) or a central plant book-
let (for outputs more than 35 kW). All maintenance and servicing operaons and combuson checks
must be wrien on the booklet, together with the name of the person responsible for servicing.
Combuson checking
Combuson checking consists of a control of the boiler eciency. Boilers that, aer the checking, will
have eciency rates lower than the ones required and not changeable with suitable adjustments (that
must be performed by qualied technicians), must be replaced.
Boiler operaon and servicing
The user (owner or tenant of the at where the boiler is installed) or the administrator of the block of
ats (in case of a central heang system) are responsible for the appliance operaon and servicing; they
can both transfer the responsibility of the servicing and eventually of the operaon to another person,
which must be a qualied technician as indicated by the Laws. Even if the user or the administrator de-
cide to assume personally this responsibility, ordinary servicing of the warm air heater and combuson
checks must be anyway carried out by a qualied technician

Green Heating Technology
7
User guide
The front control panel
1
green
Electrical Supply Indicator Light
- boiler not electrically supplied.
Blinking - boiler electrically supplied, but not acve because the knob 12 is on.
On - boler acve. Knob 12 or along the .
Flashing with short pulses - actuated for mistake, by the user, a funcon reserved to
the technician. Rotate immediately the knob 13 back on the scale.
2
yellow
Burner Indicator Light
- the ame in the burner is o.
On - the ame in the burner is on.
3
red
Alarm Indicator Light
- no problems detected.
Blinking or Flashing - see "Alarms - boiler block" on page 30.
4service Indicaon, on the display, for the Technician, usually not displayed.
52-digit
number
on the
display
Normally it indicates, in °C, the temperature of the water going out of the boiler (heat-
ing or domesc).
During the adjustment of the heang system temperature (rotang the knob 12 along
the scale) or domesc hot water (rotang the knob 13 along the scale) it
shows the set value, in °C.
6
-
on the
display
Usually, they are shown and they indicate that the boiler is ready to
supply heat to the relevant heang or DHW When the boiler is in Summer
mode , the symbol
They blink during the actual heat delivery, by the boiler, to the relevant system.
7
s
e
r
v
i
c
e
service
8
9
10
12 13
14
15
16
11
3
4
67
5
1
2
00037 00

Green Heating Technology
8
8Posion on which the knob 12 should be posioned to turn the boiler o or to reset
a boiler block.
9Posion on which the knob 12 should be posioned to acvate the boiler in Winter
mode (both Heang and Domesc Hot Water funcons available).
10 Scale on which the knob 12 should be posioned to adjust the Heang system tem-
perature (aenon: only if the Remote Control Kit is not installed).
11 Posion on which the knob 12 should be posioned to acvate the boiler in Summer
mode (only Domesc Hot Water funcon available and exclusion of Heang) (only if the
Remote Control Kit is not installed).
12 boiler
mode Knob that allows to switch the boiler in OFF mode Summer 11 or Win-
ter 9 and to adjust the Heang system temperature 10.
If the Remote Control Kit is installed, see "Remote Control Kit" on page 39.
13 DHW Knob that allows to adjust the Domesc Hot Water temperature (along the scale 14 ).
The use of the posions
14 Scale on which the knob 13 should be posioned to adjust the Domesc Hot Water
temperature.
15 service Posions of the knob 13 which use is reserved to the technician.
Do not turn the knob 13 on these posions.
16
Commands on the lower side
17 System pressure gauge
18 System lling and pressure restoring cock
19 GAS cock
Commands outside the boiler
Externally the boiler, suitably posioned in the building
(generally by the installer or by the electrician), two devices
that the user should access to, are present. The presence
and the characteriscs of these devices are prescribed by
the regulaon in force.
Two-pole switch: it is located usually close to the boiler and
it's for electrically insulang the boiler itself from the
domesc mains power supply network.
Room thermostat: it commands electrically the boiler to acvate or deacvate the heang system, in
order to keep the room temperature (detected by a sensor) within a value set by the user, Regulaon
in force prescribe its posioning, the temperature limits within the user can adjust it and the periods
of heang. On trade are available programmable room thermostats: most of them allow to make a
weekly programming of various temperature levels, besides special programs for various purposes.
We suggest to choose original ITALTHERM accessories
00001_00
17
18
19

Green Heating Technology
9
Typical use
Preliminary operaons
fFirstly, the knob 12 should be on
the posion
fMake sure, by the gauge 17 that
the cold-system temperature is al-
-
. When the pressure
, the boiler
stops working. In this case, open
the system lling cock 18 up to ob-
tain, on the gauge, a value between
.
The system pressure raises with the temperature: a too high inial cold-system pressure could
lead to water drain from the 3 Bar safety valve aer the system heang-up.
fMake sure that the gas cock 19 is open.
fMake sure that the boiler is electrically supplied: green light 1blinks.
Boiler acvaon
fRotate the knob 12 on Summer 11 if you want to have only hot water producon, or on Win-
ter 9 if you need both room heang and hot water producon.
fOpening a hot water cock, the burner ignites and, aer a short me (that also depends on the char-
acteriscs of the plant externally the boiler) hot water ows from the cock.
fIn Winter mode, consequently a request by the Room thermostat, the burner ignites and the
produced heat is sent, by means of the system vector liquid, to the heang elements of the building.
If, in the mean me, a Domesc Hot Water request takes place, this laer has the priority for the
whole request me. Since the DHW requests are usually limited in me, they generally don't have
any eect on the room heang.
Temperature adjustment
Note: correct adjustment leads to creang the condions for energy saving.
fby rotang the knob 12 along the scale 10, the seng of the heang
system temperature is made (the value, during the adjustment, is shown on the display 5). Generally,
in the deep cold season and/or with poor building thermal insulaon (or if you noce that the burner
stays on for a long me, but the room temperature rises too slowly) prefer higher sengs. On the
contrary, if you noce that the room temperature exceeds too much, for thermal inera, the value
set on the room temperature, it's appropriate to decrease the system temperature.
Note: if the Remote Control Kit is installed, see also "Remote Control Kit" on page 39 and the relevant
instrucon booklet.
Note: don't make confusion between the heang system temperature here described, with the
temperature of the room set on the Room Thermostat.
s
e
r
v
i
c
e
service
8
9
10
12 13
14
15
16
11
3
4
67
5
1
2
00037 00

Green Heating Technology
10
f
by rotang the knob 13 along the
scale 14, the seng of the hot
water produced by the boiler, is
made (the value, during the adjust-
ment, is shown on the display 5).
On this type of boiler, we suggest to
set the knob in such a way to have
a comfortable hot water tempera-
ture by drawing only hot water or
eventually by mixing it with a lile
cold water. Avoid maximum values
if not strictly needed, that will force
to mix the hot water with bigger
quanes of cold water. Consider that, because of the dispersions along the pipings, a certain me
is needed to have a stable water temperature on the cock outlet, therefore the best temperature
evaluaon is achieved during a bath or a shower.
ones on the electrical circuits, on hydraulic system or on the gas system, and whatever other
ITALTHERM Srl is not responsible for damages caused by the incorrect, wrong or unreasonable
The burner doesn’t turn on
fif the room thermostat (or programmable room thermostat, or similar) is installed, check that it is
really requiring the room heang;
fcheck that the electrical power supply is present and that the Summer/Winter knob isn't posi-
oned on (stand-by) but on Summer or Winter . The light should be steadily ON
(see details in the paragraph "The front control panel" on page 7);
fif the RED locking light was on or blinking, or if you noce an anomalous behaviour of the light indi-
cators, see the paragraph "Alarms - boiler block" on page 30;
fcheck on the gauge that the boiler pressure is correct (1÷1.5 Bar in a cold state) or at least not below
;
flet the technician to look up the notes in the paragraph "Electrical diagram" on page 37.
Shortage of domesc hot water producon
fcheck that knob is not set on a too low value or to the “service”posion
fcall a qualied technician to check gas valve regulaon;
fcall a qualied technician to check, and eventually clean, the DHW exchanger.
Remark: where the water hardness value is too high, it is suggested the installaon of a soen-
ing device, in order to prevent the limestone precipitaon; this operaon avoids a frequent
cleaning of the coil.
s
e
r
v
i
c
e
service
8
9
10
12 13
14
15
16
11
3
4
67
5
1
2
00037 00

Green Heating Technology
11
The eects of the periods of inacvity can be relevant in parcular situaons such as in ats used only
for some months per year, most of all in cold places.
The user will have to decide to put the boiler in the SAFETY SHUT OFF state disconnecng all the sup-
plies, or to . When there is the possibility of freezing
it is convenient to chose between the advantages and the disadvantages of the SAFETY SHUT OFF and
of the Stand By/An Freezing Way.
Safety shut o
fTurn o the general switch on the Electrical Supply Line of the Boiler;
fClose the Gas Tap;
When it is expected that the temperature is going to decrease under 0°C, call a technician to do
the following:
• Fill the system with an an-freezing soluon (unless the system was already lled with said solu-
on) otherwise it must be completely emped. Noce that if it had been necessary to restore
the pressure (because of possible loss) in an heang system already lled with an An freezing
soluon, the concentraon of the soluon could have decreased and it could not guarantee the
An freezing Protecon.
• completely empty the hot and cold sanitary water system, including the sanitary circuit and the
boiler’s sanitary exchanger.
Remark: the boiler is equipped with a system which protects the main components from the excep-
onal cases of mechanical lock, due to the inacvity in presence of water and scale. The an-
locking funcon can’t work in Safety shut o mode, because of the lack of electrical supply.
Before re-igning the boiler, have a technician check that the pump is not blocked due to inac-
vity (for the technician: unscrew the plug in the centre of the cap to access the rotor sha and
turn it with a screwdriver or other suitable tool).
Stand-by mode with an-frost & an-locking funcon
When the boiler is le in stand-by during a period of inacvity, it will be protected against freezing by
several funcons provided in the electronic controller, which heat the parts involved when the tempera-
ture falls below factory set values.
The an-frost heang is accomplished by turning on the burner and pump.
In addion, when the boiler is in stand-by, it periodically acvates the main internal components to
avoid rare cases of blockage due to inacvity in the presence of water and lime. This can also occur
when the boiler is locked (red lamp on) provided that the system pressure is correct.
In order for these systems to be acve:
• the boiler must be receiving gas and electricity;
• boiler must be le in stand-by mode (Summer/Winter knob on, green lamp ashing);
• system pressure must be correct (1÷1.5 bar in a cold state, minimum 0.5 bar)
In case of lack of gas, the burner won’t turn on and the boiler will go in LOCK OUT state (red lamp on or
ashing). Nevertheless the pump will work, making the water circulate in the system and reducing in
this way the possibility of freezing. It is available, on demand, an An Frost Electrical resistance kit which
must be installed on the secondary exchanger to protect the boiler also in case of lack of gas.

Green Heating Technology
12
ATTENTION: the an-frost protecons cannot intervene in the absence of electricity. If you an-
cipate this possibility, we recommend you add a good brand of an-freeze to the heang sys-
tem, following the producer’s instrucons.
When the power comes back on, the boiler will check the temperature measured by the two
probes and, if it suspects freezing veried by a parcular automac control cycle, alarm 39 will
be triggered. For more details, see the relave descripon in the paragraph "Alarms - boiler
block" on page 30.
We recommend that you completely empty the hot and cold sanitary water system, including
the sanitary circuit and the boiler’s sanitary exchanger. The an-frost funcon does not protect
the sanitary circuit outside the boiler.
“Ambient An-Frost” Funcon
Note: if you want to use the “Ambient An-Frost” funcon that is oen available in common room
thermostats or chronothermostats, it is necessary to leave the boiler in Winter mode and NOT
in stand-by.
The “Ambient An-Frost” funcon does not protect the sanitary circuit outside the boiler and,
especially, in areas where the heang system doesn’t reach. For this reason, we recommend
that you empty the cold and hot sanitary water from the parts of the system that are at risk of
freezing.
Note for the translator/writer: Place in this paragraph all the recommendaons relevant to the compli-
ance with laws in the desnaon naon/country (if any). As an example (from Italian regulaon):
as this boiler has an heat output lower than 35 kW (about 30000 Kcal/h),
it is not required to install the appliance in a dedicated room, provided that the room complies with
the regulaon in force and that all installaon rules assuring a safe and regular gas boiler operaon,
are strictly respected.
when
a boiler with air draught from the installaon room (B… appliance type) is installed. Venlaon
must be made and sized in compliance with Laws and Rules in force.
at the end of the installaon, the installer must:
• explain the operaon of the boiler and its safety devices to the user;
• give this user this booklet and the documentaon within his/her competence, duly lled in where
required.

Green Heating Technology
13
16
23÷43
68
23÷43
68
3
52 52 88 39
3545
116116
52 52 88 39
G
G
TA / L
L
TA
F
F
C
C
M
M
R
R
400
700
680
120
R
M C
300
207 193
233
147
75 1
2
3
00002_03
712
10
159
136
GF
Legend:
1 Flue outlet
2 Air inlet for coaxial system
3 Air inlet for split-pipe system
Gas: connecon on the boiler ¾”;
on the wall, using the oponal
original ng kit ½”
R System return (¾”)
M System ow (¾”)
C DHW outlet (½”)
F Fresh water inlet (½”)
TA/L Indicave posion for
electrical power supply and
room thermostat wirings
TA Room thermostat wiring
L Electrical power supply wiring
front view -
hydraulic connecons
on the wall
(with oponal ng kit)
upper view
front view -
hydraulic connecons
on the boiler
le side view -
hydraulic connec-
ons on the boiler
Pump capacity diagram
0
1
2
3
4
5
6
0 200 400 1000 1200600 800 1400
00003
00
pressure (m H2O)
water ow (l/h)
mod. 24F
mod. 30F
speed 3 - 2 of the pump
The graph is referred
to the capacity available
to the system.
Air must be withdrawn from places free of pollutant (like uorine, chlorine, sulfur, ammonia, alkaline or
similar agents). In the event of installaon of the boiler in atmospheres with not negligible presence of
aggressive chemical substances (e.g. hairdressing salons, laundries) we recommend to foresee the air
inlet from outdoor, choosing the type C installaon.

Green Heating Technology
14
Besides, for an opmal boiler funconing, wa-
ter pressure should be more than 1 Bar. A lower pressure could make dicult to restore correctly the
pressure the heang system, and reduce the ow of hot water available from the boiler.
In case of higher pressure it is indispensable to install a PRESSURE REDUCER upstream the
boiler.
If the wa-
ter hardness is more than 25° fr it’s required to install a soener to bring the hardness below that value.
Besides, the presence of solid residuals or impuries in the water (for example in case of new systems)
could compromise the correct funconing of the boiler. For DHW producon systems, the regulaon in
force prescribes a safety lter to protect the systems.
Thanks to its anfreeze system, inner components could never reach a temperature lower than 5°C. This
system is acvated when the boiler is supplied by the electrical and gas lines, provided that the pressure
in the heang system is correct. On request, it is possible to install an anfreeze electrical resistance device
on the domesc exchanger, so as to protect boiler even in case of gas lack.
In case of boiler installaon in rooms where temperature can drop down to 0°, it is advisable
to ll the heang circuit with an anfreeze liquid specic for heang systems, propylenic glycol
based, following the instrucons of its manufacturer. Pay aenon to the correct product con-
centraon: adding those substances to the heang water in incorrect dose could lead to the
deformaon of the seals and cause unusual noises during operaon.
ITALTHERM S.r.l. will not be held responsible for consequent damages.
“F” forced draught models can be installed outdoor, but only in parally protected places.
The boiler minimum and maximum working temperatures are menoned in the paragraph "Technical
data" on page 34 and on the boiler data plate.
The materials used for the boiler installaon, in-
cluding the devices and/or the materials used for
thermal insulaon, should be so to maintain their
within the temperature range indi-
cated on the data plate.
If the place where the boiler is located is
converted from outdoor to indoor (e.g.
veranda) it will be necessary to verify the
compliance of the new conguraon with
the laws and rules in force, and to make
the modicaons required.
00004 00

Green Heating Technology
15
32.5
36
18
328
52 52 88
16
39 45 35 36 53
18
36
335
400
32.5
35 11 14
35
712
A A
B B
C
D
A
B
C
00005 04
If necessary, the open hooks can be
posioned at any point along the edge B
of the boiler's frame bracket, provided
that they are 2 and that they support the
device in a correct and safe way.
Remark: A re-usable metal jig ( D in the gure) can be ordered separately, so as to facilitate connec-
ons and xing points posioning (when the original connecon kit is used). If the metal jig and/
or the original connecon kit are not used, refer to the paragraph "Dimensions and connec-
ons" on page 13 for the posion of the connecons directly on the boiler.
fLocate the exact posion of the boiler considering the sucient clearances for maintenance and
servicing: at least 50mm laterally and 300 mm on the lower side
fTo x the boiler with wallplugs (“stud” type with nut), centre the rele-
vant wall holes as regards to A points. To hang it with open hooks, place
hooks in correspondence with Bpoints.
fIf the metal jig is used, hang it on the wall using the same wallplugs or
hooks and the holes or slots indicated in the gure ( A for the plugs and
B for the open hooks).
fFix up the connecons and all ducts for heang ow and return, cold
water, hot water, gas and electrical cables, predisposing them in the
holes of the metal jig or respecng the measures in the paragraph "Di-
mensions and connecons" on page 13. The upper edge of boiler’s body,
used as a reference in the paragraph "Flue system types" on page 21, is
represented by the doed line C in the gure.
fRemove the jig (if used) and hang the boiler to the wallplugs or hooks,
using the holes or slots indicated in the gure ( A for the plugs and Bfor
the open hooks).
fplaced to close the hydraulic connecons on
the boiler.
fProceed with the hydraulic, gas, electrical and ue connecons following the instrucons and warn-
ings reported in the following paragraphs.
The connecons of the boiler are engineered to t plain couplings with screw ring, interposing
a plain gasket of suitable size and material, that ensure a reliable seal even without excessive
ghtening force. They are NOT suitable for hemp, teon tape or similar materials
Remark: the lower grid is spare inside packing, not assembled. We suggest to x the grid only at the
end of the boiler installaon operaons.
Gas (1/2”)
Hot Water
Outlet (1/2”)
Cold Water
Inlet (1/2”)
Heang
Flow (3/4”)
Heang
Return (3/4”)
Electrical
Power Supply
Room
Thermostat

Green Heating Technology
16
Make sure that the hydraulic and heang systems ducts
the electrical system. They are absolutely NOT SUITABLE for such a use. Besides: they don't
guarantee the earth dispersion; in case of electrical fault they could generate a fulguraon risk;
there could take place galvanic currents in the pipings and consequent corrosion and hydraulic
leaks.
Advices and suggesons to avoid vibraons and noises in the system
fDo not use pipes with reduced diameters;
fDo not use bends with small radius and reducons of important secons.
Cleaning and preservaon of the systems
The eciency, the reliability and the safety of the boilers, as all generic thermal systems and compo-
nents, depend strictly on the features of the water that supply them and on their treatment.
A proper treatment of the water improves the protecon of the systems against corrosions (and there-
fore perforaons, noise, leaks, etc.) and limestone incrustaons that drascally reduce the eciency
of the thermal exchange (consider that 1 mm of limestone incrustaons reduces of 18% the thermal
exchange of the heang element on which it has been formed).
ITALTHERM guarantees its products only if the characteriscs of the water comply with UNI 8065, re-
ported also in laws on energy saving.
Thoroughly wash the heang system with water, before connecng the boiler. This will elimi-
nate residual like welding drops, slag, hemp, masc, mud, rust and other dirt from pipes and
radiators. Otherwise, these substances could enter the boiler and damage the internal compo-
nents (pump etc.).
f, in the
suitable quanty and following the instrucons of its manufacturer.
fIf the water on boiler inlet is harder than 25° fr, it’s required to install a soener to bring the hardness
below that value, as required by the reference regulaon.
fFor oor system and generally all low temperature systems, the water treatment product must have
lming acon (protecon against corrosion and incrustaon) and acon against bacteria and algae.
Heang system
fConnect the safety evacuaon ducts of the boiler to an evacuaon funnel. If safety valves are not
connected to an evacuaon device, their intervenon could ood the room. The manufacturer can-
not be held responsible for any damage arising from that situaon.
Once all system connecons have been carried out, proceed with system lling. This operaon should
be made with care, respecng the following steps:
fOpen the radiators venng devices;
fCheck that the plug of the automac air vent, incorporated in the boiler circulator, is unscrewed: if
not, unscrew it and leave it unscrewed, even aerwards, for normal operaon;
fIf it's required to ll the system with an-freeze soluon, do this operaon, then hermecally close
the connecon or the valve used to put the soluon in, to allow the pressurizaon.
fGradually open the lling cock 1 ;

Green Heating Technology
17
fCheck the correct funconing of automac venng de-
vices, eventually installed;
fClose the radiators venng devices as soon as water ows
out of them;
fMake sure, by reading the pressure gauge 2, that the pres-
sure reaches the opmal value of ;
fClose the water supply valve 1 and bleed each radiator
again;
fRepeat the venng and pressurizaon operaons unl
the air is completely purged from the system.
Due to various installaon possibilies, the gas cock 3 supplied with the original Connecons Kit has a
simple male Ø ½” connecon, facing the rear of the boiler. The gas pipe 4, upstream the gas cock 3, should
be supplied by the installer.
-
-
The gas connecon, as generally the boiler installaon, must be done by qualied personnel as
prescribed by the regulaon in force, because a faulty gas connecon could lead to re, explosion
and other very serious damages to persons, animals and objects. The manufacturer cannot be
held responsible for any damage arising from that situaon.
fVerify what follows:
• cleaning of all system gas pipes in order to avoid the presence of work residuals that could com-
promise the correct boiler funconing;
• gas line and ramp conformity with laws and rules currently in force;
• internal and external ghtness of the gas system and connecons;
• supply pipe must have a secon greater than or equal to the boiler one;
• supply gas must correspond to the one for which the boiler has been set: otherwise, it's manda-
tory to ask to qualied personnel to set the boiler for the correct gas type;
• an intercepon valve must be installed upstream the appliance.
fOpen the meter valve and purge the air that is inside the system pipes (including all the appliances).
00006 00
2
4
1
3

Green Heating Technology
18
The link of the room thermostat works with a safety extra low voltage (SELV); connect it to
the voltage free contacts of the room thermostat/chronothermostat. On NO account must any
electrical voltage be applied to these terminals.
All low-voltage wirings (e.g. Room Thermostat or Chronothermostat for trade) must be kept
separate from power supply cables, as to avoid boiler malfunconing due to electrical noise. It
is advisable to use separate tubes for them.
The boiler must be connected to a 220÷240V - 50Hz electrical power supply. In any case, the power
supply voltage must be within the range –15% ... +10% from the nominal value (230V); otherwise it
may cause malfuncons or failures. It is necessary to respect the polaries L-N (Live L=brown; - Neu-
tral N=blue) - otherwise the boiler may not work - and the earth connecon (yellow-green cable).
Place upstream the boiler a bipolar switch in compliance with the regulaon currently in force.
The installaon must be made complying the regulaon currently in force and generally with the
standard cra rules.
For the general electrical supply of the appliance the bipolar switch should be used. The use of adaptors,
mulple taps and extensions is not allowed.
If the supply cable must be replaced, use one of the following cable types: H05VVF or H05-VVH2-F. It is
To replace the cable,
open the control panel cover, unlock its fastening device and disconnect it from the terminals. Install
the new cable proceeding in the reverse way. When connecng the cable to the boiler, it’s mandatory:
• to leave the Earth wire about 2 cm longer than the other (Live and Neutral) wires;
• to lock the cable upstream the terminals by means of the suitable fastening device.
Electrical safety of the appliance is only achieved when it is well connected to an ecient earth-
ing system, executed as indicated by the safety rules actually in force.
A qualied technician must check that the electrical system is in line with the maximum power allowed
by the boiler, indicated on the data plate, with parcular aenon to the cables secon.
ITALTHERM S.r.l. declines any responsibility for damages to persons, animals or things caused by
the faulty or missing connecon of the boiler earthing and by failure to comply with the rules.
Flue systems
General indicaons
To ensure the funconality and the eciency of the appliance it is necessary to foresee, for the hori-
of air inlet and ue outlet, a slope of 2÷5% downwards from the boiler to the outside (see
diagram).
In the case of outlet duct, to avoid condensaon reux in the sealed chamber, it is neces-
.
Air inlet and ue outlet terminals should be protected by suitable approved ue accessories, to avoid
environmental elements penetraon.
Don't lean the ue pipe into the chimney, but stop it before the inner surface of the chimney. The axis
of the ue pipe must intersect the axis of the chimney or of the ue duct.

Green Heating Technology
19
00008 ENG 00
Eventual
coaxial
inlet
Horizontal flue outlet Vercal flue outlet
2% ÷ 5%
Condensate
collecon
device
Flue duct
or chimney
NO
NO
YES
Carefully follow the prescripons by the Naonal and Local Regulaon in force.
Respect the minimum and maximum ue system length (refer to "Flue system types" on page 21).
In case of ue outlet on wall, the posions and the distances prescribed by the regulaon mist be re-
spected (see "Flue terminals posioning" on page 20).
Reducer for short systems
In case of short air inlet and ue outlet systems, to achieve the correct combuson, the installaon of
a suitable ue diameter reducer could be necessary. The reducer that ts most cases is supplied with
the boiler. In a few parcular cases, it could be necessary a dierent reducer, oponal, to be ordered by
menoning its inner diameter or the relevant spare part number (see technical literature). Indicaons
about the use of the reducer (and the relevant diameter, for the oponal reducer), on the basis of the
ue system type and length, are contained in the paragraph "Flue system types" on page 21
Referring to the tables, calculate the
equivalent linear length considering
every addional bend installed (ex-
clude the ones shown in the diagrams)
and, if required, install the reduc-
er D as shown in the gure.
Comply with the regulaon in force
when installing the ue systems.

Green Heating Technology
20
Flue terminals posioning
Posizionamento dei terminali di scarico (nella parete stessa di cui si sta valutando la zona di rispeo)
per apparecchi muni di venlatore in funzione della loro portata termica
(per informazioni deagliate, vedere la norma UNI 7129-3:2008 e successive modiche o integrazioni)
Posizionamento del terminale
Quota
Distanze minime (mm)
Apparecchi
da 4 kW
no a 7 kW
Apparecchi
oltre 7 kW
no a 16 kW
Apparecchi
oltre 16 kW
no a 35 kW
Soo nestra A1 300 500 600
Adiacenza ad una nestra A2 400 400 400
Soo ad una apertura di aerazione/venlazione B1 300 500 600
Adiacenza ad una apertura di aeraz./venlaz. B2 600 600 600
Distanza in vercale tra due terminali di scarico C1 500 1000 1500
Adiacenza in orizzontale ad un termin. di scarico C2 500 800 1000
Soo balcone *) D1 300 300 300
Fianco balcone D2 1000 1000 1000
Dal suolo o da altro piano di calpeso E 400 ***) 1500 ***) 2200
Da tubazioni o scarichi vercali od orizzontali **) F 300 300 300
Soo gronda G 300 300 300
Da un angolo/rientranza/parete dell’edicio H 300 300 300
*) I terminali soo un balcone pracabile, devono essere colloca in posizione tale che il percorso dei
fumi, dal punto di uscita del terminale al loro sbocco dal perimetro esterno del balcone, compresa
l'altezza dell’eventuale parapeo di protezione (se chiusa), non sia minore di 2000 mm. Per una
correa computazione del percorso dei fumi vedere la norma UNI 7129-3:2008.
**) Nella collocazione dei terminali devono essere adoate distanze non minori di 500 mm da mate-
riali sensibili all'azione dei prodo della combusone (per esempio, gronde e pluviali di materia
plasca, elemen sporgen di legno, ecc.); per distanze minori adoare adeguate schermature nei
riguardi di de materiali.
***) In ques casi i terminali devono essere opportunamente prote per evitare eventuali conta
dire con persone.
Nota: Non è consento scaricare a parete con terminale collocato
all’interno di un balcone chiuso su 5 la (vedere la norma UNI
7129-3:2008). Il terminale dovrebbe sporgere oltre il
balcone con però la computazione delle distanze
di cui sopra.
This is valid only in Europe.
Replace with informaon
from local regulaon about
terminals posioning
This manual suits for next models
2
Table of contents
Popular Water Heater manuals by other brands

A.O. Smith
A.O. Smith THR-160 Installation Instructions and Use & Care Guide

proTough
proTough NR111-DV installation manual

Solahart
Solahart Streamline Electric owner's manual

A.O. Smith
A.O. Smith GPVH 40 Service parts list

A.O. Smith
A.O. Smith Innovo 12-160 Installation, service & maintenance manual

SioGreen
SioGreen SIO 14 Operation & installation manual