ITC T-6203 User manual

OPERATION MANUAL
T-6203
ALARMING SIGNAL GENERATOR
Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
PUBLIC ADDRESS SYSTEM
VOL
PLAY
MSG
MIC
in
PLAY
SIREN
REC in
ON
OFF
STANDBY
PLAYALARM MODE RECORD
STOPSTART
ALARMING SIGNAL GENERATOR
T-6203

2
1. SAFETY PRECAUTIONS .......................................................................................3
2. GENERAL DESCRIPTION ....................................................................................5
3. FEATURES ...............................................................................................................5
4. NOMENCLATURE AND FUNCTIONS
4.1 Front Panel ..............................................................................................................6
4.2 Rear Panel..............................................................................................................6
5. .........................................................................................7
6. APPLICATIONS .......................................................................................................8
7.SPECIFICATIONS .................................................................................................. 9
8.DIMENSIONAL DIAGRAM ...................................................................................10
MACHINE OPERATION
TABLE OF CONTENTS

1. SAFETY PRECAUTIONS
3
Be sure to read the instructions in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest dealer.
ITC
ITC
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.

SAFETY PRECAUTIONS
4
An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your ITC dealer as to the cleaning. If dust
is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result.
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
Due to product upgrades, while some of the features and specification in the user manual does not
match the actual functions, sorry for any inconvenience and thanks for your kind understanding!

3. FEATURES
The T-6203 is a public address emergency panel with can provide an ideal public address solution from small
to big places such us mosques, schools, hotels and factories to train stadium and air stations.
2. GENERAL DESCRIPTION
1.
2.
3.
4.
With alarm trigger and siren output.
One minute's recording/IC for playing music.
Output volume control.
2 optional alarm modes.
5

4. NOMENCLATURE AND FUNCTIONS
4.1 FRONT PANEL
1. VOL
Recording volume control
2. ALARM MODE
The alarm for a certain choice
3. START
Start / suspended, or put the sound recording
4. STOP
Stop recording, setting the tone or options
Optiona
5. SELECTION SWITCH
Siren: Siren alarm signal output
Fang recording: Audio alarm output Curing
Recording: MIC -Microphone recording
LINE-Line recording
6. POWER
Power indicator
7. STANDBY SWITCH
1: Always power indicator light, keyboard operable
0: Power indicator light flashes, the keyboard can
not operate
VOL
PLAY
MSG
MIC
in
PLAY
SIREN
REC in
ON
OFF
STANDBY
PLAYALARM MODE RECORD
STOPSTART
1 5 6 7
234
USE ONLY WITHA250V FUSEUSE ONLY WITHA250V FUSE
+ ALARM IN - ALARM OUT MIC IN REC IN
810 11
912
8. AC POWER INPUT
9. ALARM IN
Alarm signal input
10.ALARM OUT
Alarm signal output
11.MIC IN
Microphone input
12.REC IN
Audio line input
6
4.2 REAR PANEL

MANUALLY OPERATION
5. MACHINE OPERATION
(2)Play recording to alarm: when you set the optional
switch at MSG, press play knob, it has a recording
sound output; press alarm mode and select longalarm
mode , press play knob again, then the recording will
be outputted repeatedly.
2 When the machine stands standby, you can't play
siren or recording manually.
.
AUTOMAITC MODE
(1)Play recording alarm : set the optional switch at
MSG , if there is a trigger signal being inputted in
the siren spigot at the real panel , then the output
spigot OUTPUT will output recorded signals , you
can press STOP to cancel alarm according to the
alarm mode by your command.)
(2)Play recording to alarm: when you set the optional
switch at MSG, press play knob, it has a recording
sound output ; press alarm mode and select long-
alarm mode , press play knob again , then the re-
cording will be outputted repeatedly.
Recording operation:
Before recording , you need erase the whole
recording, and then record,the detailed steps
are as follows:
1. When the machine stands in the state of working.
(1)Siren alarms : when you set the optional switch
at siren , press play knob , then it has a short siren
output;press alarm mode and select longalarming
mode,press play knob again,and it has a longsiren
output.
1 Siren alarms : when you set the optional switch at
SIREN,if you input a trigger signal in the siren spigot
at the real panel, and the output spigot won't output
siren signals till the trigger signal is relieved
.
(3)When you haven't cancelled the input trigger signals
in the alarm spigot at the real panel,and place the
optional switch at SIREN or MSG, you can get corresp-
onding input
2 When the machine stands standby, the STOP knob
can't work, others are as above.
.
1 Place the optional switch at LINE or MIC.
2 Press START and STOP simultaneously and
keep it for more than 3 seconds till the PLAY/
RECORD indicator light is ON simultaneously.
3 PLAY indicator light is ON and RECORD light
is OFF,it express finished the erasure and the
CMOS chip is empty.
4 According to the record audio,place the option
switch at the LINE AND MIC (make the switch
and channel relatively), and press the START
to startup record.At this moment, PLAY light is
OFF, RECORD light is ON.
.
.
.
.
5 CMOS chip is recorded fully or press the STOP
key,the RECORD light is off.The chip can record
one minute at the most.
6 After finish the record, make the option switch
turn to PLAY MSG to play.
.
.
7

6. APPLICATIONS
REAR PANEL CONNECTIONS
USE ONLYWITHA 250V FUSEUSE ONLYWITHA 250V FUSE
+ ALARM IN - ALARM OUT MIC IN REC IN
EMERGENCY ALARM INPUT
MIC 4 MIC 3 MIC 2 MIC 1 EMC 1 EMC 2
OUTPUT
AUX 3 AUX 2 AUX 1
INPUT
INPUT
MIC 4MIC 5 MIC 3 MIC 2 MIC 1 EMC 1 EMC2
LINE INPUT
MIXER PRE-AMPLIFIER
MIC
AUDIO
OUT
R
L
AUDIO SOURCES
COM
ADRESS TAG
8

7.SPECIFICATIONS
MODEL
EMERGENCY PANELEMERGENCY PANEL
T-6203
DIMENSION(mm)
NET WEIGHT
GROSS WEIGHT
484X209X44
POWER CONSUMPTION
POWER REQUIREMENTS
5.2Kg
4Kg
30W
Power LED/Alarm work of the police state of indicator
INDICATORS
9
~220-240V 50/60Hz

VOL
PLAY
MSG
MIC
in
PLAY
SIREN
REC in
ON
OFF
STANDBY
PLAYALARM MODE RECORD
STOPSTART
8. DIMENSIONAL DIAGRAM
UNIT:mm
6
41
41
296
290
44
50
440
484
10cmMore 10cmMore
10cmMore
10
USEONLY WITHA 250V FUSEUSEONLY WITHA 250V FUSE
+ ALARM IN - ALARM OUT MIC IN REC IN
VOL
PLAY
MSG
MIC
in
PLAY
SIREN
REC in
ON
OFF
STANDBY
PLAYALARM MODE RECORD
STOPSTART

PUBLIC ADDRESS SYSTEM
PUBLIC ADDRESS SYSTEM
VersionV0.3
Table of contents