ITW Simco-Ion IQ Easy Speed-T User manual

5201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
IQ Easy Speed-T
& IQ Easy Hybrid-T
Static Neutralizing Bars
INSTALLATION AND OPERATING INSTRUCTIONS

i5201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
TABLE OF CONTENTS
1. SAFETY WARNINGS ......................................................................................................................1
2. DESCRIPTION...............................................................................................................................3
3. SPECIFICATIONS...........................................................................................................................4
4. INSTALLATION .............................................................................................................................5
Unpacking ............................................................................................................................5
Mechanical Installation .........................................................................................................6
Electrical Connections ..........................................................................................................8
For Connection to IQ Power Control Station........................................................................8
Standalone ...........................................................................................................................10
Set Up..................................................................................................................................11
5. OPERATION ...............................................................................................................................14
Indicator Lights ...................................................................................................................14
With IQ Power Control Station...........................................................................................14
Standalone Operation ..........................................................................................................14
6. MAINTENANCE...........................................................................................................................15
Regular Cleaning .................................................................................................................15
Removing Heavy Soil...........................................................................................................15
Calibrate Bar........................................................................................................................15
7. TROUBLESHOOTING....................................................................................................................16
8. PARTS AND ACCESSORIES ............................................................................................................17
9. WARRANTY AND SERVICE............................................................................................................18

15201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
1. SAFETY WARNINGS
PLEASE READ INSTRUCTIONS COMPLETELY BEFORE STARTING
INSTALLATION
ALL INSTALLATION AND TROUBLESHOOTING OPERATIONS MUST
BE PERFORMED BY QUALIFIED TECHNICAL PERSONNEL
The following safety guidelines must be observed in order to prevent physical injury
and damage to objects or to the static neutralizing bar itself:
This instruction manual uses symbols to identify dangerous situations as follows:
WARNING –
Electrical installation and repairs must be performed by a
skilled electrical engineer according to the applicable national and local
regulations.
AVERTISSEMENT –
L'installation et le service électrique doivent être
effectuées par un électricien qualifié conformément aux réglementations
locales et nationales.
WARNING –
The device must only be powered by a Limited Power Source
(LPS) or NEC Class 2 power supply.
AVERTISSEMENT –
L'appareil ne doit être alimenté par une source
d'alimentation limitée (LPS) ou NEC Class 2.
WARNING –
The equipment must be properly grounded. Grounding is
required to ensure safe and proper operation and to prevent electrical shocks
upon contact.
AVERTISSEMENT –
Le matériel doit être correctement mis à la terre. Mise à
la terre est nécessaire pour assurer un fonctionnement sûr et correct et pour
éviter les chocs électriques en cas de contact.
WARNING –
Disconnect power before performing any work on the unit.
AVERTISSEMENT –
Débranchez l'alimentation électrique avant toute
intervention sur l'appareil.
WARNING –
Keep the unit dry. Do not operate the unit in flammable or
explosive environments.
AVERTISSEMENT –
Gardez l'appareil au sec. Ne pas utiliser l'appareil dans
des environnements inflammables ou explosifs.

25201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
CAUTION –
The emitters are sharp and can cause physical injury.
ATTENTION –
Les émetteurs sont pointues et peuvent causer des blessures.
NOTE –
The high-voltage emitters (9 kV) are limited to a current of 50 uA,
which means that they are electrically safe to touch and shockproof.
NOTE –
IQ Easy bars are designed to neutralize electrostatically charged
surfaces only.
NOTE –
During the ionization process a small amount of ozone is produced.
The ozone concentration around the electrodes depends on a large number
of factors, such as the amount of space around the static neutralizing bar and
the air circulation. This means that no general value can be specified for the
ozone concentration. For installations with poor ventilation it may be
necessary to take precautions to ensure safe values of ozone concentration.
NOTE –
If changes, adjustments etc. are made without prior written consent
or if repairs are performed using non-original parts, the equipment's
warranty will no longer be valid.

35201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
2. DESCRIPTION
The IQ Easy Speed-T and the IQ Easy Hybrid-T are static bars designed to
neutralize electrostatically charged surfaces. Both static bars are equipped with an
integrated high-voltage power unit, ion emitters and status LEDs. They require a 24
VDC supply voltage to be provided via a 5-pin M12 connector.
The IQ Easy Speed-T has been optimized for high web speeds exceeding 1600 feet-
per-minute and/or distances from 2” to 9”, and is available in lengths from 10.8” to
156.9”, in increments of 2.4”.
The IQ Easy Hybrid-T performs at its optimum between a distance of 6” and 18”,
at material speeds below 1600 feet-per-minute, and is available in lengths from 15.1”
to 149.8”, in increments of 7.1”.
Figure 1: IQ Easy Static Bar
Connector End
The 24 VDC supply voltage is converted inside the static neutralizing bar into
positive and negative high voltage. The high voltage generates an electrical field at
the emitters of the static bar, which causes the air molecules around the emitters
to be converted into positive and negative ions. When an electrostatically charged
material comes within operating distance of the static bar, ions from the static bar
are exchanged with the charged material until the material is neutralized.
The (green) power LED indicates when the static neutralizing bar is in operation,
is in standby or when the bar receives commands. The (red) alarm LED indicates if
the static bar is overloaded or communications is interrupted.

45201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
3. SPECIFICATIONS
Electrical
Input Voltage 24 VDC
Input Current 0.75A (max)
Input Connection 5-pin M12 (A-coded) male receptacle
Output Voltage 7.5 kV Speed-T, 9 kV Hybrid-T
Output Current (to Ground) 50 μA per emitter (max)
Indicators (2)
Green (steady) = Operation
Green (flashing) = Standby
Green (flickering) = Communication
Red (steady) = Fault
Red (blinking) = Communication Failure
Environment
Intended Use Industrial, indoor use only
Compliance RoHS
Ingress Protection Class IP66
Operating Temperature 131°F [55°C] (max)
Operating Humidity 70% RH, no dewing permissible (max)
Target Material Speed >1600 fpm [488 m/min] Speed-T
<1600 fpm [488 m/min] Hybrid-T
Operating Distance 50-225 mm [2-9”] Speed-T
150-450 mm [6-18”] Hybrid-T
Mechanical
Length 264-3984 mm [10.8-156.9”] Speed-T
384-3804 mm [15.1-149.8"] Hybrid-T
Width 25 mm [1”]
Height 49 mm [1.93”]
Weight 1.2 lb/ft [1.8 kg/m]
Enclosure Glass fiber reinforced polyester
Compliance RoHS Compliant

55201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
4. INSTALLATION
WARNING –
Electrical installation and repairs must be performed by a
skilled electrical engineer according to the applicable national and local
regulations.
AVERTISSEMENT –
L'installation et le service électrique doivent être
effectuées par un électricien qualifié conformément aux réglementations
locales et nationales.
WARNING –
The equipment must be properly grounded. Grounding is
required to ensure safe and proper operation and to prevent electrical shocks
upon contact.
AVERTISSEMENT –
Le matériel doit être correctement mis à la terre. Mise à
la terre est nécessaire pour assurer un fonctionnement sûr et correct et pour
éviter les chocs électriques en cas de contact.
WARNING –
Disconnect power before performing work on the unit.
AVERTISSEMENT –
Débranchez l'alimentation électrique avant toute
intervention sur l'appareil.
WARNING –
The device must only be powered by a Limited Power Source
(LPS) or NEC Class 2 power supply. An LPS certified power supply has a
limited output power, which means that it always generates a safe output
voltage.
AVERTISSEMENT –
L'appareil ne doit être alimenté par une source
d'alimentation limitée (LPS) ou NEC Class 2.
Unpacking
Carefully remove all equipment from its carton and inspect the contents:
• Check that the details on the packing slip correspond to the details of the
product received.
• Check that the equipment is free from damage.
• If any damage has occurred during shipment, notify the local carrier
at once. A report should also be forwarded to Simco-Ion, 2257 North
Penn Road, Hatfield, PA 19440. See Section 9 of this manual for Return
Shipment information.

65201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
Mechanical Installation
NOTE –
Conductive machine parts in the vicinity of the static neutralizing
bar have a detrimental influence on its operation. For optimum results, the
static bar must be installed as per Figure 4.
1. Directly in front of where static electricity causes problems.
2. At an optimum distance from the material to be neutralized:
• 2” [50 mm] - 7” [175 mm] (IQ Easy Speed-T)
• 6” [150 mm] - 12” [300 mm] (IQ Easy Hybrid-T)
3. Emitters must face the material to be neutralized.
4. DO NOT mount the bar over a roller or where the material to be neutralized is
in contact with any other surface.
Figure 2: IQ Easy Static Bar Dimensions

75201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
Figure 3: IQ Easy Static Bar Mounting
Figure 4: IQ Easy Static Bar Positioning
4. Attach the static neutralizing bar using the fasteners supplied. See Figures 3 and
4.
5. Lock the static bar in the brackets by manually tightening the screws in the
brackets.
6. Connect the M12 connector of the power cable to the static bar and route the
power cable to the power supply safely.

85201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
Electrical Connections
WARNING –
Electrical installation must be performed by a skilled electrical
engineer according to applicable national and local regulations.
AVERTISSEMENT –
L'installation et le service électrique doivent être
effectuées par un électricien qualifié conformément aux réglementations
locales et nationales.
WARNING –
IQ Easy Bars must be properly grounded.
AVERTISSEMENT –
Le matériel doit être correctement mis à la terre.
WARNING –
Remove power before working on IQ Easy Bars.
AVERTISSEMENT –
Débranchez l'alimentation électrique avant toute
intervention sur l'appareil.
WARNING –
IQ Easy Bars must only be powered by a Limited Power
Source (LPS) or NEC Class 2 power supply.
AVERTISSEMENT –
L'appareil ne doit être alimenté par une source
d'alimentation limitée (LPS) ou NEC Class alimentation 2.
NOTE –
IQ Easy Bars will not function properly if emitters are covered.
For safe and reliable connection to 24 VDC power, IQ Easy Bars are provided with
an appliance inlet for connection of a detachable power supply cord. There are
several methods of making this electrical connection:
For Connection to IQ Power Control Station
1. Remove protective cap from static bar inlet connector.
2. Place the appropriate M12 connector on the cable against the static bar
connector and rotate the connector until the keyed connectors align. Press
the connectors together and turn the coupling nut clockwise to thread it on.
Finger-tighten the coupling nut until the connector is fully seated.
3. Connect cable to control station.
a.
M12 to M12 Cable (recommended)
– Place the other M12 connector on the
cable against DEV1 thru DEV6 connector and rotate the connector until
the keyed connectors align. Press the connectors together and turn the
knurled coupling nut clockwise to thread it on. Finger-tighten the coupling
nut until the connector is fully seated.
b.
M12 to RJ-45 Cable
– Connect RJ-45 plug on other end of cable to
connector 1 thru 10, labeled POWER & COMM, on the control station.
4. Route the cable away from any moving machine parts and secure the cable to
prevent damage.

95201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
Figure 5:Typical IQ Easy Cables

10 5201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
Standalone
The IQ Easy Static Neutralizing Bar may be operated without a control station.
In this case, the IQ Easy Static Bar will enter Standalone operating mode. In
Standalone Mode, the IQ Easy Static Bar operates in Fixed mode ionization with
the standard 50/50 balance. Wiring normally used for communication is internally
switched to provide fault output.
Fault Output
If the bar is operating normally (no red indicator light), the output pin 4 (black) and
pin 2 (white) connected together, will be energized with +24 VDC (50 mA max). If
the bar is in a fault mode (red indicator light lit steady) the output (pin 4 and pin
2 connected together) will not be energized; 0 VDC. Voltages are referenced to pin
3 (blue 0V/ground).
Note: Pin 4 (black) and pin 2 (white) MUST be connected together in standalone
mode.
NOTE –
Fault Output only functions in standalone mode.
Figure 6: IQ Easy Static Bar Wiring Color Code
The wiring color code shown in Figure 6 is typical for 5-pin M12 A-coded
connection cables.
Figure 7: IQ Easy Static Bar Standalone Wiring
NOTE –
Electrical connections shall be made by qualified personnel in
accordance with national and local electric codes using only Recognized
connectors appropriate for 22 AWG wires and rated for no less than 24
VDC 4A.

11 5201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
WARNING –
For personal protection, and to ensure proper function, the
GRAY* and BLUE wires must both be connected to ground.
AVERTISSEMENT –
Pour votre sécurité, et pour assurer un bon
fonctionement, les cables GRIS* et BLEU doivent tous deux être connectés
à la terre.
* The GRAY wire may appear GREEN or GREEN/YELLOW on some models.
Le GRIS du cable peut apparaître VERT ou VERT/JAUNE sur certains
modèles.
Figure 8: IQ Easy Static Bar Connector Pin-Out
The pin-out connections are:
1 (brown) +24V
2 (white) COMM A
3 (blue) ground
4 (black) COMM B / internal fault output (Standalone mode only)
5 (gray / green / green-yellow) ground
Set Up
A variety of information can be checked, and operating parameters set, for the IQ
Easy Static Neutralizing Bar through the IQ Power Control Station via the static bar
page / tab. Tap on the device icon for the static bar to access these pages.
To edit or select an operating parameter, tap on the pencil icon to the right of the
parameter description.
Device Name: A user editable name to identify the specific static bar (14 character).
Bar Type: A fixed description for the device type (Speed static bar, Hybrid static
bar, etc.)
Bar HV: Turns the bar HV power supply on/off. Turning the bar HV power off
places the bar in standby, the green indicator on end of bar will begin to flash.

12 5201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
Ion Output: Displays the ionization level, in percent, where Bar Calibration =
100% and the ionization level in terms of microamps for both positive and negative
ionization.
Balance: A ratio of input power supplied to the high voltage power supplies that
related to ion balance. In Fixed, Auto-Tune and CLFB modes this is a display only
and non-editable. The Balance may only be user adjusted in the Manual mode.
Operation Mode: A user selectable operating mode for the static bar (Manual,
Fixed, Auto-Tune, CLFB).
• Fixed - 50/50 balance standard operation (default factory setting). Fixed
provides standard operation, with output voltage regulation.
• Auto-Tune - Enhanced operation. This mode includes the current
monitoring found in Fixed mode, plus automatic compensation that takes
into account web speed, bar type, bar mounting distance and measured
ion current to optimize static neutralization performance. In order to
successfully invoke Auto-Tune, certain operating parameters must be
defined:
– Web Speed will have to be entered by the user.
– Mounting Distance will have to be entered by the user. It is the distance
between the face of the static neutralizing bar and the web, or material to
be neutralized.
• CLFB - Closed Loop Feed Back, best control of ion balance, requires
pairing with a downstream IQ Easy Sensor Bar. The sensor bar detects any
voltage imbalance on the web, or material to be neutralized, then transmits
this information to the static neutralizing bar. The static bar makes
incremental changes to the balance setting until downstream charges are
minimized.
• Manual - Allows manual control of the ion balance. Manual mode includes
voltage regulation and current monitoring found in the standard mode, plus
manual control of the ion balance ratio. This mode of operation would
only be selected where the web, or material to be neutralized, exhibited
extreme and consistent charging of one polarity.
Mounting Distance: A user entered dimension, the spacing between the face of
the static neutralizing bar and web (surface being neutralized). The factory default
mounting distance is 4” (100 mm) for a Speed-T type bar, and 6” (150 mm) for a
Hybrid-T type bar.
NOTE –
This information (Mounting Distance) MUST be correct. It is
used by the static neutralizing bar when in Auto-Tune mode. If this
information is not correct, the static bar may not operate properly when in
the Auto-Tune mode.

13 5201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
Web Speed
: A user entered value used in the Auto-Tune Mode only.
Sensor Quantity – The number of sensors found on the sensor bar.
Overall Sensor Avg – The average voltage reported by all sensor modules on a static
sensor bar.
Feedback Sensor Avg – The feedback voltage for use in CLFB control. This is
determined by using the Sensors for Feedback, a user adjustable operating parameter.
Warning Setpoint – The web voltage level at which the sensor bar will set a
“Warning” and illuminate the yellow indicator light on the end of the bar. The
factory default Value is 5kV, however this value may be user adjusted.
Alarm Setpoint – The web voltage level at which the sensor bar will set an “Alarm”
and illuminate the red indicator light on the end of the bar. The factory default value
is 20kV, however this value maybe user adjusted.
Web Voltage Sensor 1,2,3… – The voltage level reported by a given sensor module.
Device Version – The firmware revision in the device.
Device Locater Utility – Causes the indicator lights on the deceive to flicker for a
brief time to aid in verifying location of a given device.
Alarm Test Utility – Causes an alarm output to aid in checking/troubleshooting
alarm sensing connections.
IQ Easy Bar Calibration – Displays the time and date of last calibration and allows
for calibration of the bar.
Paired Sensor: The specific sensor bar used with a static neutralizing bar in closed
loop feedback (CLFB) mode. The static neutralizing bar MUST be upstream
(before) the sensor bar.
Pairing is controlled by matching the sensor bar address to the IQ Easy static
neutralizing bar address. In either case, the sensor will appear as a tab on the
neutralizer device page on the Control Station Display.

14 5201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
5. OPERATION
The IQ Easy Static Neutralizing Bar performs a self-test which includes illumination
of the two (green and red) indication lights on the static bar. The self-test and power
up of the high voltage supplies occurs before ionization is produced at the emitters.
This takes approximately five seconds after the application of power.
Indicator Lights
Two indicator lights are located on the connector end of the static bar: green and red.
Green
• A steady green light indicates the static bar is powered and active
• A flashing green light indicates the HV power supplies are off and the bar is
in standby
• A brief rapid flickering of the green indicator light indicates the static bar
has received a command from the Control Station
Red
• A steady red light indicates an internal fault in the static bar
• A blinking red indicator light indicates a communication failure
With IQ Power Control Station
The operation of the IQ Easy Static Neutralizing Bar can be controlled through the
IQ Power Control Station. In operation, a device icon appears on the Home Page.
Tapping on the device icon opens a Summary page containing information about
the IQ Easy static neutralizing bar, and static sensor bar (if paired). More detailed
information and user editable parameters are available through device tabs. For
information on these details see the Set Up section in this document.
NOTE –
If the static bar presents a premature Clean Bar alarm, this may
indicate the need to calibrate the static bar; see Maintenance for details.
NOTE –
Newly installed IQ Power Static Neutralizing Bars may require
calibration; see Maintenance section for details. Machine frames adjacent
the bar, rollers, etc. may interfere with the ionization process. If the
Ionization Output of a new bar is less than 80%, this may indicate the need
to calibrate the static bar.
Standalone Operation
If an IQ Easy Static Neutralizing Bar is energized without a control station it will
detect a lack of digital communication. In this case it enters the Standalone mode
and switches the communication wiring over to a fault output function. For details
on the fault function see Standalone in the Installation section.
In Standalone mode the IQ Easy Static Bar defaults to Fixed mode for the
ionization. Fixed provides standard operation, with output voltage regulation and a
50/50 balance setting. Normal operation is indicated by a green light on the end of
the bar. If the red indicator lights the bar has an internal fault and service is required.
Standalone mode does not offer a clean bar alarm.

15 5201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
6. MAINTENANCE
WARNING –
Remove power before working on IQ Easy Bars.
AVERTISSEMENT –
Débranchez l'alimentation électrique avant toute
intervention sur l'appareil.
Regular Cleaning
Clean the emitter points and the static neutralizing bar regularly with a stiff bristle,
non-metallic brush.
WARNING –
The emitters are sharp and can cause physical injury.
AVERTISSEMENT –
Les émetteurs sont pointues et peuvent causer des
blessures.
Removing Heavy Soil
Clean the static neutralizing bar using isopropyl alcohol. Be sure to allow the static
bar to dry completely before applying power.
Calibrate Bar
NOTE –
Calibration should be performed when the system is first installed
and may be performed after the static bar has been cleaned and the system
verified as operating correctly.
If the system is new, it may be necessary to perform an initial calibration. The initial
calibration sets the relative nominal ion output for the system. Calibration should
only be performed on IQ Easy Static Neutralizing Bars that are new or just cleaned
and known to be in proper working order.
During calibration the target to be neutralized (web, film, etc.) may remain in place,
but MUST NOT BE MOVING. If the web is moving past the static bar (e.g. the
machine is in operation) the calibration will be faulty.
The system should be “on” and in the operating mode. On the IQ Power Control
Station tap on the device icon for the IQ Easy static bar. Tap on the Neutralizer
tab. Tap on the page forward arrow to get to the last page. Find the IQ Easy Bar
Calibration line and tap on the pencil. Enter the Control Station password at the
prompt (Note: the factory default password is “PASSWORD”.) Tap on “yes” at
“Calibrate IQ Easy Bar?”.
During calibration the system output will be cycled and the indicator lights on
the static bar end will flash. Calibration takes as long as 5 seconds. The indicated
ionization output will be high (90% to 100%).
The calibration data is stored in non-volatile memory in the IQ Easy bar and used
on subsequent power ups.

16 5201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
7. TROUBLESHOOTING
WARNING –
Remove power before working on IQ Easy Static
Neutralizing Bars.
AVERTISSEMENT –
Débranchez l'alimentation électrique avant toute
intervention sur l'appareil.
Signal Problem Cause Solution
LEDs on bar do
not light
No high voltage
at emitters
No supply
voltage
Wiring problem
Apply power to Control Station &
turn on
Reconnect IQ Easy bar to different DEV
connector on Control Station
Check AC adapter (if operating
standalone) for input and output
power
Replace cable with known good cable
Red LED on
bar is lit
Internal fault
in bar
Various Cycle power to bar to see if fault clears
(if fault does not clear, return bar to
factory for repair)
Red LED on
bar is blinking
Communication
failure
Various
Wiring problem
Cycle power to bar to see if fault clears
Change connection at Control Station
Replace cable with known good cable
If multiple device have
communication failure; turn off
Control Station, disconnect all devices,
reconnect one-by-one to isolate
problem
If fault does not clear, return bar to
factory for repair
Green LED on
bar is flashing
No high voltage
at emitters
Bar is in
standby
Change bar HV setting at control
station from off to on

17 5201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
8. PARTS AND ACCESSORIES
Item Part Number
Mounting Kit 5051777
M12 to M12 Cables for connecting Static Bar to Control Station with straight
connector at bar end
1.5 meter (4.9 foot)
5 meter (16.4 foot)
10 meter (32.8 foot)
20 meter (65.6 foot)
30 meter (98.4 foot)
5051939
5051791
5051792
5051793
5051794
M12 to M12 Cables for connecting Static Bar to Control Station with right angle
connector at bar end
5 meter (16.4 foot)
10 meter (32.8 foot)
20 meter (65.6 foot)
30 meter (98.4 foot)
5051796
5051797
5051798
5051799
M12 to RJ-45 Cables for connecting Static Bar to Control Station (1 thru 10) with
straight connector at bar end
4.57 meter (15 foot)
9.14 meter (30 foot)
5051840
5051844
M12 to RJ-45 Cables for connecting Static Bar to Control Station (1 thru 10) with
right angle connector at bar end
4.57 meter (15 foot)
9.14 meter (30 foot)
5051841
5051845
M12 Cables with flying leads for Standalone Mode with straight connector at bar
end
5 meter (16.4 foot)
10 meter (32.8 foot)
5051606
5051737
M12 Cable with flying leads for Standalone Mode with right angle connector at
bar end, 5 meter (16.4 foot) 5051607
Connector for Standalone Mode - Provides 500 mm (20 inch) flying leads for user
connection (use with M12 to M12 cable) 4612473
AC Adapter for Standalone Mode, does not provide output
5 meter (16.4 foot) cable w/ straight connector for bar, 120 VAC
5 meter (16.4 foot) cable w/ straight connector for bar, 230 VAC
5 meter (16.4 foot) cable w/right angle connector for bar, 120 VAC
5 meter (16.4 foot) cable w/right angle connector for bar, 230 VAC
5051608
5051609
5051610
5051611
Mounting Kit (includes mounting bracket, perf strip and hardware) 5051455
Static Bar Cleaning Brush 4670204

5201223 Rev. J
IQ Easy Speed-T & Hybrid-T
Static Neutralizing Bars
Simco-Ion
2257 North Penn Road
Hatfield, PA 19440
(215) 822-6401
(800) 203-3419
www.simco-ion.com
© 2019 Simco-Ion. Printed in the U.S.A.
9. WARRANTY AND SERVICE
This product has been carefully tested at the factory and is warranted to be free
from any defects in materials or workmanship. Simco-Ion will, under this warranty,
repair or replace any equipment that proves, upon our examination, to have become
defective within one year from the date of purchase.
The equipment being returned under warranty should be shipped by the purchaser
to Simco-Ion, 2257 North Penn Road, Hatfield PA 19440, transportation prepaid
and insured for its replacement cost. Prior to returning any goods for any reason,
contact Simco-Ion Customer Service at (215) 822-6401 for a Return Authorization
Number. This number must accompany all returned items.
This warranty does not apply when the equipment has been tampered with, misused,
improperly installed, altered, has received damage through abuse, carelessness,
accident, connected to improper line voltage, or has been serviced anyone other than
an authorized factory representative.
The warranty does not apply when Simco-Ion parts and equipment have been
energized by other than the appropriate Simco-Ion power supply or generator,
or when a Simco-Ion power supply or generator has been used to energize other
than Simco-Ion parts and equipment. Simco-Ion makes no warranty, expressed or
implied, nor accepts any obligation, liabilities, or responsibility in connection with
the use of this product other than the repair or replacement of parts stated herein.
Information in this publication supersedes that in all previous published material.
Specifications are subject to change without notice.
This manual suits for next models
2