Meech 915EX User manual

Model 915EX
Shockless AC Bar
Operating
Manual


Contents
Introduction 3
Certication 3
Inspection 4
SpecialConditionsforSafeUse 4
Operation 5
Installation 6
TechnicalandConstruction 9
Maintenance 10
FaultFinding 11
RepairsandWarranty 14
CEApproval15
HealthandSafety15
Productsshowninthisdocumentmaybecoveredbyoneormorepatents,patentsappliedfor
and/orregistereddesignsand/ortrademarks.ForfurtherinformationpleaserefertoourHead
Oceorvisitwww.meech.com.
©MeechStaticEliminatorsLtd.,27.10.17


Introduction
TheMeechModel915EXhasbeendesignedforuseonthemostarduousstatic
eliminationproblems.Thespecialresistivecouplingofitsemitterpinsrendersthem
shockless,whilstgivingpowerfulstaticneutralisationperformance.Thisenablesthe
bartoeliminateveryhighstaticchargesonhighspeedwebsandatlongerrangesthan
haspreviouslybeenpossible.
Certication
ECtypeexaminationcerticateNo:
BASEEFA04ATEX0347X
3
Meech International Ltd
Witney, Oxon, OX290YN, UK
tel:+44 1993 706700; Fax:+44 1993 776977
915Ex
dims 77.5 x 18mm
Cool Gray 1
Gas group IIB, temp Class T6 (T85
O
C)
T amb -20 to +35
O
C. IP65
Model:
915Ex
1180
II 2 GD EEx m
Baseefa: 04ATEX0347X
Hyperion 915Ex
operating manual

Inspection
TheModel915EXBarwascarefullypackedatthefactory.Nevertheless,we
recommendcarefulexaminationofthecartonandcontentsforanydamage.Ifdamage
isevident,keepthepackingmaterialandimmediatelynotifythecarrierofapossible
damageclaim.Shippingclaimsmustbemadebytheconsigneetothedelivering
carrier.
SpecialConditionsforSafeUse
1. TheModel915EXmustbeusedinconjunctionwithaMeechType904power
supplyor904CMsystem.
2. Thepowersupplyshallbeprotectedbyafusecapableofwithstandinga
prospectiveshortcircuitcurrentof4000A
3. Theusermustdetermine,inconsultationwithMeech,thesuitabilityofthe
apparatusforusewithanysolventspresentattheapplication.
4. Whenusedindustyenvironments,theequipmentmaynotbeusedinassociation
withdustshavinganelectricalresistanceequaltoorlessthan103 Ohm
5. Whenusedindustenvironments,theequipmentmaybeusedonlywithdusts
requiringanignitionenergyofgreaterthan0.2m.J.
6. Theusermustdetermine,inconsultationwiththemanufacturer,thesuitabilityof
theapparatusforusewithparticularsolvents.
4

Operation
ThetypicalMeechModel915EXinstallationconsistsofoneormorebarsconnected
toaMeechModel904PowerUnit.
ThePowerUnitconvertstheelectricalsupplyintoahighvoltage,lowamperage
output.Thisoutputenergyistransferredtothe915EXbarbytheHTcable.
TheresistivelycoupledelectrodesareenergisedbytheACvoltagefromthePower
Unit.Theelectrodesemitthisenergy(coronadischarge)intheformofafieldof
ionisedair.Thisionisedairsuppliesionsofbothpolarities.
Electrostaticallychargedproductswhichpassthroughthiscoronaareimmediately
neutralisedandbecomestaticfree.
Undertestconditions,theMeechModel915EXhasbeenfoundtogivechargedecay
timesthatareuptoeighttimesfasterthanstandardACshocklesseliminatorbars. 5

6
Installation
The915EXBarcanbeplacedbetween25mmand150mmfromthesurfacetobe
neutralised.Itisimportanttoensurethatthesurfacetobeneutralisedhasfreeairon
bothsidesandthatearthedmetalobjectsare,wherepossible,atleast20mmaway
fromthebar.Theseprecautionswillmaximisetheunit’sionisationcapability.
Goodresultscanbeachievedatdistancesupto150mmbutasthedistancefromthe
objectincreases,thespeedofchargeneutralisationwilldecrease.
Atypicalinstallationdistanceis50mmfromthetargetsurface.Thisgivesexcellent
performanceathighweborproductspeeds,whilstavoidingpossibledamagefrom
webbreaksorproductmis-feeds.Veryfastwebsmayrequirethebartobeasclose
as25mmtotheweb.
Correctpositioningofthebar(s)isvitaltoefficientoperation.Thefollowingdiagrams
showthecorrectinstallationprocedures:
1.Theoptimaldistancefrommaterialtobeneutralised.

Mountingofthebarisby20mmM4studsmountedinatrackattherearofthebar.
Thesecanbeslidtoanypointalongthebar’slengthtomeetthemachine’savailable
fixingpoints.
Thechassisofthebariselectricallyconnectedtogroundonthepowerunitviathe
flexiblearmouredconduit.However,itisgoodpracticetoprovideasecondary
groundingthroughthefixingpointswherepractical.
TheHTcableandarmouredconduitrequireconnectiontoaMeechmodel904power
unit.Pleaseconsultthe904instructionmanualforfurtherinstruction.
NB:Meechmodel904powerunitisnotATEXratedandhencemustbemounted
outsidethehazardouszone.Forthisreasonastandard5mHTcableisprovidedbut
thiscanbeextendeduponrequest.
1. Freespaceisrequiredonoppositesidesofthetargetmaterial,notarollerorsolid
object.
7

8
2. Avoidproximitytoearthedpartsofmachineryasthiswilldistortthecoronaand
reduceitseciency.
3. Ifbarsareneededonbothsidesofthematerial,theyshouldbe
staggered.
4. Thebarsmustbeearthedforcorrectoperation.Ifinanydoubtrunanearthwire
fromthebartotheearthstudonthePowerUnit.

TechnicalandConstruction
Operatingvoltage : 7.0kV
OperationsTemperature : -20°Cto35°C
Length : Availableinlengthsfrom80mmto4000mm
Overalllengthis60mmgreaterthanthe
eectivelength.
Cable : 5metresshieldedinexibleconduit;longer
lengthscanordered.
Weight : Approx1,100gmsper1000mmlength
Crosssection : 18mmx42mm(inc.ofendcaps)
Construction : AnodisedaluminiumandreretardantPVC
extrusion.
EmitterPoints : Titanium
Mounting : M4x20mmstuds.Thesearelocatedin
achanneltoprovideuniversalmounting
points.
Operatingrange : 30-150mm
9

Maintenance
Ionisersrequireperiodiccleaning.Duringnormaloperation,dirtwillbuild-upon
theemitterpinsanduponthebodyoftheioniser.Thiswillcauseareductionin
performance.
Typically,weeklycleaningissucient.However,equipmentusedinsomeheavy
contaminationareas,suchasgravureprintingorwhereplasticfumesarepresent,may
requiredailycleaning.Equally,inaClass100area,cleaningmayonlyberequiredon
amonthlybasis.
Beforecleaning,ensurethattheequipmentisswitchedo.
Emitterpinscanbecleanedveryeectivelywithabrush.Adrytoothbrushisideal.
Ionisingbarswillneedperiodicwipingtocleangreydepositsfromthesurface
ofthebar.AclothmoistenedwithasmallamountofIPAormethylatedspiritsis
recommended.Allowamomenttodrybeforeswitchingon.
ShouldyouhaveanyadditionalquestionsregardingthemaintenanceofMeech
equipmentpleasecontactMeechInternationaldirectlyoryoulocalMeechdistributor.
10

FaultFinding
Testsmustbecompletedbyaqualiedelectricalengineer.
IfindoubtpleasecontactMeechheadoceoryourlocaldistributor.
CAUTION:
Whilstnodangertopersonnelexists,itisessentialthat,withtheexceptionofbars
withawaterresistantoption,highvoltageionisingequipment,makesnocontactwith
waterorwaterbaseduids.Shouldsuchaneventoccur,disconnectimmediatelyand
returnequipmenttothemanufacturerforwaterdamageassessment.
TheModel915EXionisingbarformspartofasystem,comprisingthebaritselfanda
Model904PowerUnit.
Toverifywhereafaultmayhaveoccurreditisimportanttotesteachitemofthesystem
individually.Shouldmorethanonebarbeconnectedtoapowerunit,thesemustbe
testedindividually.
TochecktheModel915EXbarfollowtheproceduredetailedbelow.
1. SwitchotheelectricalsupplytothesystemanddisconnecttheIECplug.
11

12
2. Disconnectallionisingbarsfromthepowerunit.
3. FollowthetestprocedurefortheModel904PowerUnit.Thiscanbefoundinthe
instructionmanualoftheModel904.

4. Havingcheckedthepowerunit,reconnectoneModel915EXionisingbar.
5. Usingahighvoltageprobeandmetermeasurethevoltageonthepinsofthe
ionisingbar.Thisvoltageshouldbeapproximately6.5kV.
CAUTION:
Thistestmustonlybecarriedoutwhentheinstallationareaisnon-hazardous.This
mayrequirethebartoberemovedfromitsnormalinstallationposition.
6. Ifthevoltageisbelow4.0kVthenthebarshouldbereturnedtoMeechforservice
and/orrepair.
7. Ifthereismorethanonebartotest,disconnecttherstitemandrepeattheabove
stepswithsubsequentbars.
13

RepairsAndWarranty
The915EXbariswarrantedbyMeechStaticEliminatorsLtdtotheoriginalpurchaser
againstdefectsinmaterialandworkmanshipforoneyearafterpurchase.Shouldany
malfunctionoccur,pleasereturnthebardirectlytoMeechStaticEliminatorsoryour
localdistributor.AllproductsreturnedtothefactoryMUSTbeaccompaniedbyareturn
authorisationnumberandmustbeshippedprepaid.Forpromptservice,shiptheunitto
thefactorywiththereturnauthorisationnumbershownclearlyonthelabel.Besureitis
wellpackedinasturdycartonwithshockabsorbingmaterial.
Includeanotestatingthenatureoftheproblemasspecicallyaspossible,andalso
includeinstructionsforreturningthebartoyou.Wewillpayone-wayreturnsurface
shippingcostsonanyrepairscoveredunderthewarranty.
Fieldrepairsshouldnotbeundertakenduringthewarrantyperiod.Repairattemptsby
unqualiedpersonnelwillinvalidatethewarranty.
14

15
CEApproval
AnECDeclarationofConformityforthisproductexistsinrespectoftheLowVoltage
Directive:72/23/EEC(“LVD”)&ElectromagneticCompatibilityDirective:89/336/EEC
(“EMCD”)
HealthandSafety
EmissionofOzone:Considerablybelowinternationalstandardof0.1ppm.

16


©Meech Static Eliminators Ltd 2017 www.meech.com
Meech International
2 Network Point
Range Road, Witney
OX29 0YN, UK
Tel: +44 (0)1993 706700
Fax: +44 (0)1993 776977
email: [email protected]
Meech Static Eliminators
(Shanghai) Co. Ltd
7G, 7F, LP Tower
#25 Xiangfeng Road
201103 Shanghai
China
Tel: +86 400 820 0102
Fax: +86 21 6405 7736
Meech Static Eliminators USA Inc
2915 Newpark Drive
Norton, OH 44203
USA
Tel: +1 330 564 2000 / 1 800 232 4210
Fax: +1 330 564 2005
email: [email protected]
Meech Shavotech
29/2, Kharadi
Off Pune-Nagar Road
On Old Kharadi Mundhwa Road
Pune : 411014 , Maharashtra
India
Tel: +91 (0)703 093 8211 / +91 (0)741 000 4817
Fax: +91 (080) 28395963
Meech Elektrostatik SA
Kaiserbaracke 166
B-4780 St.Vith
Belgium
Tel.: +49 (0)6555 3733 399
+32 (0)80 670 204
Fax: +32 (0)80 862 821
email: [email protected]
Meech International
(Singapore) Pte. Ltd.
7 Temasek Boulevard
12 - 07 Suntec Tower One
Singapore
Singapore
038987
Tel: +65 65918859
email: [email protected]
Meech CE
Gábor László utca 2
Budapest 1041
Hungary
Tel: +36 1 7977039
+36 30 2803334
email: [email protected]
Table of contents
Other Meech Ion Bar manuals

Meech
Meech Hyperion 314IPS User manual

Meech
Meech 914 User manual

Meech
Meech 914EX User manual

Meech
Meech 976 User manual

Meech
Meech 976EX User manual

Meech
Meech Hyperion 929IPS User manual

Meech
Meech Hyperion 924IPS User manual

Meech
Meech 910 User manual

Meech
Meech 971 User manual

Meech
Meech 915 User manual