Meech 910 User manual

Model 910
Operating
Manual
Shockless AC Eliminator


Products shown in this document may be covered by one or more patents, patents applied for
and/or registered designs and/or trade marks. For further information please refer to our Head
Oce or visit www.meech.com.
© Meech Static Eliminators Ltd., 26.10.2017
Contents
Introduction 3
Installation 4
Technical Characteristics 7
Maintenance 8
Fault Finding 9
Repairs and Warranty 10
CE Approval 11
Health and Safety 11


3
Introduction
The Meech 910 Bar is a powerful static eliminator which is completely shockless
in operation and which will give many years of excellent service, provided that the
following instructions are observed closely.
General Notes On Operation
The typical Meech 910 installation consists of one or more bars connected to a Meech
Power Unit.
The Power Unit converts the primary electricity supply into a high voltage, low
amperage output. This output energy is transferred to the Meech bar by the HT cable.
A capacitive coupling inside the bar reduces the energy at the ionising pin to a level
which is completely shockproof to a human being.
The stainless steel pins on the bar emit the energy to form an ionised air corona.
When a statically charged object passes through this corona the free moving ions
are attracted to the opposite charge on the object. In this way the static electricity is
neutralised. Unused ions in the corona recombine or are discharged to earth.

4
Installation of RML Bars
Correct positioning of the bar(s) is vital to ecient operation. The general rule is that
they should be positioned immediately before the problem area, remembering that
subsequent passage of the material over rollers, or friction, can regenerate the static
charge.
The following rules should be observed closely:
1. The optimal distance from material to be neutralised.

5
2. Free space is needed on opposite side of material, not a roller or solid object.
3. Avoid proximity to earthed parts of machine as this will distort the corona and
reduce its eciency.

6
4. If bars are needed on each side of the material, they should be staggered.
5. If more than one bar is needed on the same side, they should be spaced apart.
6. Two steel xing strips are supplied with each bar for ease of installation.
The bars must be earthed for correct operation. If in any doubt run an earth
wire from the bar to the earth stud on Power Unit.
Maximum operating temperature 85 degrees C.

7
Technical Characteristics
Operating voltage : 7 kV
Pin energy : 0.15 millijoules
Max Temp : 85 deg. C
Length : 80 to 4000mm in 20 mm steps. Eective length
is 40 to 60 mm less than the eective length.
Cable : 2m of screened HT cable as standard, longer
lengths can be specied when ordering.
Weight : 750g per meter approx.
Construction : Anodised aluminium extrusion with stainless
steel emitter pins moulded in polypropylene.
Mounting : M4 x 20mm studs as standard, others available.
Operating range : 15 - 30mm

8
Maintenance
Ionisers require periodic cleaning. During normal operation, dirt will build-up on
the emitter pins and upon the body of the ioniser. This will cause a reduction in
performance.
Typically, weekly cleaning is sucient. However, equipment used in some heavy
contamination areas, such as gravure printing or where plastic fumes are present, may
require daily cleaning. Equally, in a Class 100 area, cleaning may only be required on
a monthly basis.
Before cleaning, ensure that the equipment is switched o.
Emitter pins can be cleaned very eectively with a brush. A dry toothbrush is ideal.
Ionising bars will need periodic wiping to clean grey deposits from the surface
of the bar. A cloth moistened with a small amount of IPA or methylated spirits is
recommended.
Should you have any additional questions regarding the maintenance of Meech
equipment please contact Meech International directly or your local Meech distributor.

9
Fault Finding
Tests must be completed by a qualied electrical engineer.
If in doubt contact Meech head oce or your local distributor.
CAUTION: Whilst no danger to personnel exists, it is essential than any high
voltage ionising equipment, (exception Meech Model 910 Water Resistant
Ionising Bars), make no contact with water or water based uids. Should
such an event occur, disconnect immediately and return equipment to the
manufacturer for water damage assessment. High voltage electrical equipment
should not make contact with water.
The model 910 ionising bar forms part of a system, comprising of itself and a Model
904 power supply. (See g 1)
To verify where a fault may have occurred it is important to test each item of the
system individually. Should more than one ionising appliance be connected to one
power supply, these must be tested individually.
To check the model 910 ionising bar follow the procedure detailed below.
1. Switch o the electrical supply to the system.
2. Disconnect all ionising appliances from the power supply.
3. Follow the test procedure for the model 904 power supply. This can be found
in the instruction manual of the model 904.
4. Having checked the power supply reconnect one ionising model 910 ionising
bar.
5. Using a high voltage probe (RS 610 281) and meter (RS 610 590) measure
the voltage on the pins of the ionising bar. This voltage should be
approximately 2.7 kV.
6. If the voltage is below 2.0 kV then the item should be returned to Meech for
service and or repair.
7. If no meter and probe is available, then a fast and simple test is to simply
short the pin of the ionising bar to earth using a screwdriver as follows.
Place the shaft of the screwdriver against the aluminium extrusion of the ionising
bar.

Approach the pin of the bar with the point of the screwdriver. As the screwdriver
approaches the pin, a small faint spark should jump from the pin to the
screwdriver. If The bar is under direct sunlight or bright lights it may be dicult to
see this spark.
As the spark is drawn a slight buzzing sound will also be heard. This would
indicate the bar is functioning correctly.
8. If there is more than one appliance to test, disconnect the rst item and
repeat the above steps.
Repairs and Warranty
The Meech 910 Bar is warranted by Meech Static Eliminators Ltd to the original
purchaser against defects in material and workmanship for one year after purchase.
Should any malfunction occur, please return the Ioniser directly to us. All products
returned to the factory MUST be accompanied by a return authorisation number and
must be shipped prepaid. For prompt service, ship the unit to the factory with the return
authorisation number shown clearly on the label. Be sure it is well packed in a sturdy
carton with shock absorbing material.
Include a note stating the nature of the problem as specically as possible, and also
include instructions for returning the Ioniser to you. We will pay one-way return surface
shipping costs on any repairs covered under the warranty.
Field repairs should not be undertaken during the warranty period. Repair attempts by
unqualied personnel will invalidate the warranty.
10

CE Approval
An EC Declaration of Conformity for this product exists in respect of the Low Voltage
Directive:72/23/EEC (“LVD”) & Electromagnetic Compatibility Directive: 89/336/EEC
(“EMCD”)
Health and Safety
Emission of Ozone: Considerably below international standard of 0.1ppm.
11



©Meech Stac Eliminators Ltd 2017 www.meech.com
Meech Internaonal
2 Network Point
Range Road, Witney
OX29 0YN, UK
Tel: +44 (0)1993 706700
Fax: +44 (0)1993 776977
email: [email protected]
Meech Stac Eliminators
(Shanghai) Co. Ltd
7G, 7F, LP Tower
#25 Xiangfeng Road
201103 Shanghai
China
Tel: +86 400 820 0102
Fax: +86 21 6405 7736
email: [email protected]
Meech Stac Eliminators USA Inc
2915 Newpark Drive
Norton, OH 44203
USA
Tel: +1 330 564 2000 / 1 800 232 4210
Fax: +1 330 564 2005
email: [email protected]
Meech Shavotech
29/2, Kharadi
O Pune-Nagar Road
On Old Kharadi Mundhwa Road
Pune : 411014 , Maharashtra
India
Tel: +91 (0)703 093 8211 / +91 (0)741 000 4817
Fax: +91 (080) 28395963
email: [email protected]
Meech Elektrostak SA
Kaiserbaracke 166
B-4780 St.Vith
Belgium
Tel.: +49 (0)6555 3733 399
+32 (0)80 670 204
Fax: +32 (0)80 862 821
email: [email protected]
Meech Internaonal
(Singapore) Pte. Ltd.
7 Temasek Boulevard
12 - 07 Suntec Tower One
Singapore
Singapore
038987
Tel: +65 65918859
email: [email protected]
Meech CE
Gábor László utca 2
Budapest 1041
Hungary
Tel: +36 1 7977039
+36 30 2803334
email: [email protected]
Table of contents
Other Meech Ion Bar manuals

Meech
Meech Hyperion 960IPS User manual

Meech
Meech 971 User manual

Meech
Meech 915EX User manual

Meech
Meech 976 User manual

Meech
Meech Hyperion 314IPS User manual

Meech
Meech 914 User manual

Meech
Meech 924EX User manual

Meech
Meech Hyperion 929IPS User manual

Meech
Meech Hyperion 924IPS User manual

Meech
Meech 915 User manual