5
Installation
The 914 Bar can be placed between 25mm and 100 mm from the surface to be
neutralised. It is important to ensure that the target surface has free air on both sides
and that earthed metal objects are, where possible, at least 20 mm away from the bar.
These precautions will maximise the unit’s ionisation capability.
Good results can be achieved at distances up to 100mm but as the distance from the
object increases, the speed of charge neutralisation will decrease.
A typical installation distance is 40mm from the target surface. This gives
excellent performance at high web or product speeds, whilst avoiding possible
damage from web breaks or product mis-feeds. Very fast webs may require the bar to
be as close as 25mm to the web.
Correct positioning of the bar(s) is vital to ecient operation. The following diagrams
show the correct installation procedures:
1. The optimal distance from material to be neutralised.
Mounting of the bar is by 20mm M4 studs mounted at the rear of the bar.
The chassis of the bar is electrically connected to ground on the power unit via