Meech 924EX User manual

1
Model 924EX
Pulsed DC Ionising Bar
Operating
Manual


Products shown in this document may be covered by one or more patents, patents applied for and/or reg-
istered designs and/or trade marks. For further informaon please refer to our Head Oce or visit www.
meech.com.
© Meech Stac Eliminators Ltd., Date 30.08.2018
Contents
Introducon..........................................................................................3
Cercaon..........................................................................................4
Unpacking and Inspecon ....................................................................4
Package Contents ................................................................................4
Features and Benets of 924EX............................................................6
Installaon............................................................................................9
Specic Condions of Use .................................................................15
Operaon ...........................................................................................16
Maintenance ......................................................................................17
Fault Finding .......................................................................................19
Technical and Construcon ................................................................22
Repairs And Warranty ........................................................................23
CE Approval ........................................................................................23
Health and Safety ...............................................................................23
Technical Drawing...............................................................................24

4

3
Introducon
The 924 is now available for use in Ex applicaons. The 924EX oers the same
outstanding levels of performance, reliability, easy maintenance and features
associated with Meech Pulsed DC technology. It is ATEX approved and can be
used in zone 1 applicaons. It is designed to control stac charges in short
range applicaons and is parcularly suited for use in hazardous areas and
applicaons such as gravure prinng, lm extrusion and coang.
The 924EX is a compact pulsed DC ionising bar designed to be used on the
most arduous stac eliminaon problems. The special resisve coupling
of its emier pins renders them shockless, whilst giving powerful stac
neutralisaon performance.
The 924EX is powered by the Hyperion 233v4 HL Pulsed DC Controller. They
are designed to work together as a system meaning that customer’s can now
benet from the features associated with the Hyperion range in hazardous
environments. The output voltage, frequency and balance can all be adjusted
to suit parcularly dicult applicaons and very sensive materials found in
EX zones.

4
Cercaon
EC type examinaon cercate No:
BASEEFA 18ATEX0082X
Unpacking and Inspecon
The Model 924EX Bar was carefully packed at the factory. Nevertheless, we
recommend careful examinaon of the carton and contents for any damage.
If damage is evident, keep the packing material and immediately nofy the
carrier of a possible damage claim. Shipping claims must be made by the
consignee to the delivering carrier.
Package Contents
Standard
924EX Bar Mounng Kit

5
Opons
BarMaster remote programmer.
Allows opmisaon of the output of
the 924EX
Hyperion 233v4 HL Pulsed DC
Controller
Power Cable - 4 Pin M8 (straight or
90º elbow) Available in 2,3,5 and
10M lengths.
24V DC Supply & C5 cable

6
Features and Benets of 924EX
Overall look
The prole of the 924 EX Bar provides ionisaon through alternang posive
and negave emier pins mounted in a PC ABS extrusion. The emier pins
are resisvely coupled to the high voltage pulsed DC source, rendering the
emiers shockless to touch and will give many years of service.
Compact Size and Full Length Ionisaon
The small cross-seconal size of the 924EX means that it will t into ght
installaon posions. The bar has been designed to give full performance
over its enre length, ensuring full coverage of webs that run close to
machine frames.
Sealed Contrucon
Sealed IP67 construcon allows the bar to be used in harsh environments,
subject to wash-down or where there is the likelihood of spillages. Please
note. should the bar become wet, it must be thoroughly dried before being
powered-up.

7
Shockless Titanium Emiers
As with our Hyperion range bars, the 924EX uses Titanium emier pins.
Almost indestrucble, these pins will give many years service. For the comfort
and safety of the operator, the pins are resisvely coupled and shockless to
touch.
Divider
The 924EX is designed to operate in dirty, factory environments. To minimise
the impact of contaminaon and maximise the interval between cleaning, the
bar features a divider between the posive and negave emiers. This divider
is an essenal feature of the bar.

8
T-Slot
Mounng of the bar is made easy using the T-Slot at the rear of the bar. The
M4 T-Bolts used are the same as used on other Meech Pulsed DC bars.

9
Installaon
The Model 924EX Bar should be located in the most convenient posion so
that the pins of the Bar are directed towards the target area. The bar should
be posioned to give an unrestricted path for the ions to travel to the target
area.
The Meech Model 924EX must be connected to a Pulsed DC Controller, which
must be located outside of any EX zoned area.
POWER, INPUT AND OUTPUT (I/O) WIRING MUST BE IN ACCORDANCE WITH
CLASS 1, DIVISION 1 WIRING METHODS ARTICLE 501.10(b) OF THE NATIONAL
ELECTRICAL CODE , NFPA 70.
A) THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS 1, DIVISION 1, II 2G IIC T4
GB, OR NON HAZARDOUS LOCATIONS ONLY
B) WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY
IMPAIR SUITABILITY FOR CLASS 1, DIVISION 1
C) WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT
UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO
BE NON-HAZARDOUS.
The 924EX connects to the Pulsed DC Controller by plugging the male plugs,
found at the end of the bar cabling, directly into the high voltage sockets of
the controller. The plugs and sockets are marked with “+” posive and “-”
negave indicators for correct connecon to the power supply.

10
Connect ionising equipment using grey HT connecons. Next, connect the
mains supply to the Pulsed DC Controller and switch ON. The 924EX Bar will
now produce Pulsed DC ionisaon from the emiers of the Bar.
A grounding post on the controller is provided for this purpose. Meech
recommend that, for certainty, the controller is grounded using this post, in
addion to using a grounded 24V DC supply

11
WARNING
Meech Pulsed DC Controllers require a grounded 24V DC supply. The 0V line
must be connected to ground. Failure to do so, will result in damage to the
ioniser or the 24V supply and will void the warranty.
The shockless emier pins produce ions of posive and negave polarity.
These, because of the product’s unique design, propel themselves away from
the emier points towards the target area.
The maximum output voltageis 5.5kV to respect the ATEX cercaon of the
924EX bar.
Opmum stac eliminaon can be achieved by adjustment of the “Rate”
(frequency of pulsing) and the “Balance” (proporon of posive to negave
ions generated) on the Controller.
If the bar is posioned a long distance from the target area the “Rate” should
be set to the lowest seng. If the bar is posioned close to the target area
the “Rate” should be set towards its maximum.
WARNING
Meech Pulsed DC Controllers require a grounded 24V DC supply. The 0V line
must be connected to ground. Failure to do so, will result in damage to the
ioniser or the 24V supply and will void the warranty.

12
Operating Distance (mm)
Requires optional BarMaster Remote Programmer. and Pulsed DC Controller
Frequency Rate (Hz)
Optimum Frequency Vs Operating Distance for 924EX
If the polarity of the stac charge to be removed is known, the balance can be
adjusted to give a faster decay speed.
I.E. a) If the stac charge is known to be posive the balance should
be adjusted towards negave on the controller.
b) If the stac charge is known to be negave the balance should be
adjusted towards posive on the controller.
High
Low

13
Mechanical Installaon
The 924EX is a short to mid-range bar. Dependent on the applicaon, the bar
will be mounted between 20mm and 200mm from the target surface.
The bar should be mounted securely, using all the M4 T-bolts provided with
the bar.
Correct posioning of the bar is vital for eecve stac control. There must
be no metallic objects or obstrucon between the bar and the material. The
diagram shows the area that should be kept clear.
Where “x” lengths are equal.

14
When installed at short range over a web or sheet, the bars must be
posioned away from surfaces and rollers, as shown in the following
diagrams.
Your Meech distributor will be able to assist with quesons regarding
posioning of your equipment.

15
Specic Condions of Use
If there is any damage to the web or material that is being neutralised
by the stac eliminator bar, then the bar must be checked for damage
and relevant maintenance or replacement of the bar carried out.
The equipment may not be used in associaon with dusts having an
electrical resistance equal to or less than 10³Ω.m.
The Meech 924EX stac eliminator bar shall be supplied only by the
Meech Hyperion 233v4HL Pulsed DC Controller that is set to produce
5.5kV peak maximum.
The equipment must be installed so that it is shielded from UV light.
The user must determine, in consultaon with the manufacturer, the
suitability of the apparatus for use with parcular solvents.
The plasc case presents a potenal stac discharge risk and while in
a hazardous area must be cleaned only with a damp cloth.

16
Operaon
Having connected the male grey HT plugs to the power supply, power up the
power supply and check the Pulsed DC Controller. The controller will indicate
that the bar is running correctly with a good ion output.
CAUTION:
Always turn o the power supply before connecng or disconnecng the
male grey HT plugs. Failure to do so could result in stored charges giving a
small electric shock.

17
Maintenance
Ionising bars become contaminated with usage. Dirt build-up on the body of
the ioniser and, parcularly on the pins, will cause a drop in performance. To
get the best from your bar, it should be cleaned as part of regular machine
maintenance.
If regular cleaning is not carried out, the controller will detect the drop in
performance and trigger the Clean Pin alert. See operang manual for the DC
Controller.
Before cleaning, ensure that the equipment is switched o.
Emier pins can be cleaned very eecvely with a brush. A dry toothbrush is
ideal.
Make sure the central divider is also cleaned and the pin surface of the bar.

18
Ionising bars will need periodic wiping to clean grey deposits from the surface
of the bar. A cloth moistened with a small amount of IPA or methylated spirits
is recommended.
Let dry for a minute and turn back on.
Table of contents
Other Meech Ion Bar manuals

Meech
Meech 914EX User manual

Meech
Meech 910 User manual

Meech
Meech Hyperion 314IPS User manual

Meech
Meech 914 User manual

Meech
Meech 971 User manual

Meech
Meech Hyperion 960IPS User manual

Meech
Meech 915EX User manual

Meech
Meech 976EX User manual

Meech
Meech Hyperion 929IPS User manual

Meech
Meech Hyperion 924IPS User manual