Ivation IVADIGHUM606W User manual

Digital Humidifier
User Guide
IVADIGHUM606W
Thank you for purchasing the Ivation Digital Humidifier. This User
Guide is intended to provide you with guidelines to ensure that
operation of this product is safe and does not pose risk to the user.
Any use that does not conform to the guidelines described in this
User Guide may void the limited warranty.
Please read all directions before using the product and retain this guide
for reference. This product is intended for household use only.
A comfortable indoor atmosphere is achieved at a relative humidity of between 40% and 60%. Your appliance automatically
controls the humidity level according to your chosen setting. If the air is too dry, the unit will automatically switch on. As
soon as the desired humidity level is reached, it will automatically switch off.
READ AND SAVE THESE INSTRUCTIONS
SAFETY PRECAUTIONS
When using electrical appliances, basic precautions should always be followed to reduced the risk of fire, electric
shock, and injury to persons, including the following:
• Read all instructions before using the appliance.
• To avoid fire or shock hazard, plug the appliance directly in to a 120V AC electrical outlet.
• Connect the unit only to an AC supply with a voltage according to the rating label.
• Only use the appliance indoors and within the parameters stated in the technical specifications.
• Using the appliance for a purpose for which it is not intended could pose a serious hazard to health and life.
• Do not let children operate, play with, or clean the appliance.
• Do not let persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge
operate the appliance.
• Do not let persons whose mental or physical abilities may be impaired by medication operate the appliance
unless supervised.
• Do not let persons under the influence of alcohol or drugs operate the appliance.
• Never use the appliance if there is any damage to it or the electrical cord, or if the unit malfunctions, or if the
appliance has been dropped or damaged in any way.
• Operate the appliance only when it is completely assembled.
• Do not attempt to alter or repair the appliance or access the interior.
• Disconnect the appliance from the power source before filing/emptying the water tank, before cleaning, before
assembling/dismantling of individual parts, and before moving the appliance.
• Do not reach inside the nebulizer area during operation. The high frequency oscillation causes the membrane
to become hot.
• Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs or near heat registers.
• Do NOT place humidifier near heat sources such as stoves, radiators, and heaters. DO locate your humidifier on
an inside wall near an electrical outlet. The humidifier should be at least 4 inches (10cm) away from the wall
for best results.
• Never place humidifier in an area where it is accessible to children. Never use humidifier in a closed room,
particularly where a child may be sleeping, resting, or playing (a closed room may result in excessive humidity).
• WARNING: Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet. Failure
to heed this warning may cause personal injury. Be sure to unplug the unit by pulling on the plug and not the cord.
• Never place anything over the moisture outlet when the unit is running.
• Never drop or insert any object into any openings.
• DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or
damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair.
1

• Use appliance only for intended household use as described in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold by
the manufacturer may cause hazards.
• DO NOT use outdoors.
• Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for use under the
humidifier. Never place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture.
• DO NOT allow the moisture outlet to directly face the wall. Moisture could cause damage, particularly to wall paper.
• The humidifier should be unplugged when not in use.
• NEVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water
tank and moving the unit.
• This humidifier requires daily and weekly maintenance to operate appropriately. Refer to daily and weekly
cleaning procedures. Use only cleaners and additives recommended by the manufacturer.
• NEVER use detergents, gasoline, glass cleaner, furniture polish, paint thinner, or other household solvents to
clean any part of the humidifier.
• Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens,
turn the humidifier OFF.
• Do not use humidifier in an area where humidity level is in excess of 50%. Use a hygrometer, available at your local
retailer or through the manufacturer, to measure the humidity.
• DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty.
The inside of the unit contains no user-serviceable parts. All servicing should be performed by qualified personnel only.
• Never place housing under water flow or immerse in liquids.
• Do not plug in the cord with wet hands. Electric shock could result.
• Do not pour water in any openings other than the water tank.
• To prevent damage to surfaces, do not place humidifier under overhanging surfaces.
• NEVER operate unit without water in the tank.
• Do not move unit after it has been used until unit cools completely.
• Use both hands when carrying full tank of water.
Parts Mist nozzle
Water tank cover
Water tank
Demineralization cartridge
Housing
Aroma compartment
2

Aroma Compartment
For scented mist, add fragrant essential oil (not included) to the sponge in the compartment.
Demineralization Cartridge
• Soak the demineralization cartridge in a water bath 1 hour before the first use;
the granules have to absorb water in order for the unit to perform correctly.
• Your humidifier is not designed for water which has passed through a water
softener which uses a salt. The humidifier’s demineralization cartridge cannot
absorb the salt, resulting in a white precipitate forming inside the appliance.
If a white precipitate should form anyway, the capacity of the demineralization
cartridge has been exhausted. This can occur sooner or later depending on the
hardness of the water. In this case, please replace the demineralization cartridge.
• We recommend that you do not use the appliance if your water hardness is over
25 fH.
Filling the Water Tank
• Always switch off the appliance before removing the water tank. Do not reach inside the nebulizer space while the
appliance is running!
• To protect health, safety, and proper humidifier function, use only clean, contamination-free, cold, fresh tap water in
your humidifier. If your water source is contaminated or if you are uncertain of its safety, please use distilled water.
• Do not operate the appliance when the water tank is empty!
• When the water reaches the minimum level, the unit will switch off automatically.
3
1. Take off
mist nozzle
2. Loosen the cover 3. Take off the tank 4. Loosen tank cover
5. Fill the tank 6. Tighten tank cover 7. Push down the tank 8. Push down the
cover & nozzle
Warning! When attaching the water tank to the main body of the unit, make sure the slot is in the right direction.

Operation
• Connect the appliance to a power supply. The humidifier
starts in standby status and will sound a tone.
• Press the On/off button. These default settings will be
in effect:
- Low mist 200 ml/h ±20%
- Timer is off
- DC fan is on
- Warm mist is selected
- Relative humidity setting is 70%
• Press the mode selector button to cycle through the
sleep mode, turbo mode, auto mode, and normal mode.
Under each mode, the default is warm mist.
- Sleep mode: Warm mist with the timer automatically
set at 8 hours. Mist rate is 300 ml/h ± 20% and display
panel light will dim and then go out. Only the On/off and
mode selector functions will be available. The unit will
not be controlled by environmental humidity. In 5 seconds, normal indication returns. Humidity and timer indicators
light in 10-second intervals.
- Turbo mode: Timer is off. Mist rate is 500 ml/h ± 20%. The default humidity is 70%. You can set the timer (1 – 8 hours),
select the humidity level, and choose warm or cool mist.
- Auto mode: Timer is off. Default humidity level is 70%. If the humidity falls below 70%, the unit will automatically
activate with a mist rate of 400ml/h ± 20%. You can set the timer and choose warm or cool mist.
- Normal mode: Timer is off. The default humidity is 70%. You can set the timer. You can select the desired humidity level,
mist capacity mode (by pressing the up and down buttons), and warm/cool mist (by pressing the warm/cool mist
selector button).
- Note about the timer function: If you change the setting to the sleep mode, the timer automatically sets to 8 hours. If
you activate the turbo mode, auto mode or normal mode, timer will stop automatically.
• Press the warm/cool mist selector button to choose cool mist or to activate the heater for warm mist. (The warm mist
indicator will light.)
• Press the settings selector button to switch between the humidity setting and timer setting. Make your selections by
pressing the up and down buttons.
NOTE: Always empty residual water from the tank after using the appliance. Clean the water tank after every 3 days of use.
Mist Volume Indicators
The red light bars on the display panel indicate the volume and rate of mist generated in milliliters per hour.
Humidity Selection
• Press the settings selector button once. The default humidity setting is 70%. (Number will flash.) Use the up and down
buttons to adjust the humidity level from 30% to 70%. After setting, the unit will display the current room humidity for
5 seconds.
• Note: "C0" will display when the unit continues to humidify regardless of the ambient humidity.
• When the humidity of the environment matches the set humidity level, the unit will stop. It will restart when the room
humidity decreases by 5%.
Timer Function
• Timer can be set from 1 to 8 hours.
• Press the settings selector button twice. "0H" will flash. Use the up and down buttons to set the timer. The timer will
commence counting down. When the timer reaches 0, the unit will go into standby mode.
• To cancel the set time, reset the timer to “0” and then use the up or down keys.
4
High: 400 ml/h Medium: 300 ml/h Low: 200 ml/h

water tank cleaning
transducer cleaning
Low Water Level Indicator
• The unit will automatically detect the water level in the tank when turned on. If, within 6 seconds, it detects a shortage,
the unit will sound a tone 10 times and then shut off. This is to protect the device.
• The low water level indicator will flash. Press the on/off button to turn the unit off. Disconnect it from the power supply.
• Fill the tank with water. Connect to the power supply. Press the on/off button. The unit will automatically detect the
water level in 6 seconds.
Memory Function
The unit will go into standby mode when turned off if the power supply remains connected. All the last settings will be
retained except for the timer setting. If the power is disconnected, the settings will be cleared.
Cleaning Indicator
When the unit has operated for 100 hours, the cleaning indicator function light will flash. Clean the transducer and water
tank. See below.
Cleaning
5
• After cleaning the transducer and water tank, press the down (minus) button for 5 seconds until you hear a tone.
• If the user does not clean the transducer and water tank and does not reset with the down button, the cleaning indicator
will continue flash when the unit is turned on.
• Always empty residual water from the tank after using the appliance.
• Clean the water tank after every 3 days of use.

Storing
Make sure the appliance is clean and dry. Store in a cool, dry location.
Specifications
Power rating: 120V, 60Hz
Power consumption: 85W
Noise level: ≤ 30 dB
Max. water capacity: 1.26 gal (4.8L)
Max. mist volume: 500ml/h ± 20%
Dimensions: 11.7" x 7.6" x 14" (298 x 193 x 358mm)
Weight: 4.9 lbs. (2.2kg)
Customer Service:
info@myivation.com
866-849-3049
6
Distributed by
C&A Marketing, Inc.
114 Tived Lane East
Edison, NJ 08837 USA
C&A Marketing UK LTD
167 Hermitage Road
Crusader Industrial Estate
London N4 1LZ
United Kingdom
Made in China
Ivation is a trademark of
C&A IP Holdings, LLC
©2016 All rights reserved
Table of contents